HSL-3 Heavy duty anchor

Similar documents
HSL-3 Heavy duty anchor carbon steel. Anchor Fastening Technology Manual HSL-3. Heavy duty anchor. Version /

HVU with HAS/HAS-E rod adhesive anchor

HUS-V Screw anchor. HUS-V Screw anchor. Basic loading data (for a single anchor) Mean ultimate resistance

HUS-A 6 / HUS-H 6 / HUS-I 6 / HUS-P 6 Screw anchor in precast prestressed hollow core slabs

HUS-HR, CR Screw anchor, stainless steel

Hilti HIT-HY 150 MAX with rebar

HUS-HR Stainless steel Concrete Screw A CE conformity. Corrosion resistance. European Technical Approval

HUS-HR, CR Screw anchor, stainless steel

Hilti HIT-HY 200 with rebar

(English language translation, the original version is in French language) Hilti HSL-3

HUS-H Screw Anchor. Technical data. Seismic design data. HUS-H Carbon steel screw anchor. HUS-H diameter 8, 10, 14. Seismic design data

Europeiskt Tekniskt Godkännande European Technical Approval

EUROPEAN ORGANISATION FOR TECHNICAL APPROVALS

Hilti, Inc South 122 nd East Avenue Tulsa, OK

Eurooppalainen tekninen hyväksyntä ETA 08/0173 European Technical Approval. Sormat S KA kiila ankkurit Sormat through bolt S KA

Eurooppalainen tekninen hyväksyntä ETA 01/0003. Sormat Oy Harjutie 5 FIN Rusko. Sormat Oy Harjutie 5

(English language translation, the original version is in French language) Powers Throughbolt PTB-XL-ETA7-PRO 01/02/ /01/2018.

ICC-ES Evaluation Report

Hilti KWIK HUS-EZ I (KH-EZ I) Internally Threaded Carbon Steel Screw Anchor

Bonded Anchors & Mechanical Anchors

(English language translation, the original version is in Czech language) DEWALT PTB-PRO. DeWalt Black-&-Decker Str Idstein Germany

English translation prepared by DIBt Original version in German language

TZ WEDGE ANCHOR FOR CRACKED AND UNCRACKED CONCRETE

European Technical Approval ETA-98/0001

Rakennustuotedirektiivin (89/106/EEC) artiklan 10, neuvoston direktiivi 21. joulukuuta 1988, mukaisesti notifioitu tuotehyväksyntälaitos EOTAN JÄSEN

European Technical Approval ETA- 13/0056

Eurooppalainen tekninen hyväksyntä ETA-10/0280 European Technical Approval

7Čå.e.279(1Ì HEAVY DUTY ANCHOR

European Technical Assessment. ETA-02/0020 of 22 September English translation prepared by DIBt - Original version in German language

(English language translation, the original version is in French language) Hilti HDA and HDA-R

(English language translation, the original version is in French language) Chemical anchoring system WIT-200

Rakennustuotedirektiivin (89/106/EEC) artiklan 10, neuvoston direktiivi 21. joulukuuta 1988, mukaisesti notifioitu tuotehyväksyntälaitos EOTAN JÄSEN

LOAD-CARRYING CAPACITY OF AXIALLY LOADED RODS GLUED-IN PERPENDICULAR TO THE GRAIN

Submittal Information

Injection System VMU. Injection System for non-cracked concrete and brickwork. Threaded Stud VMU-A for concrete and brickwork

The following excerpt are pages from the North American Product Technical Guide, Volume 2: Anchor Fastening, Edition 16.

(English language translation, the original version is in French language) Injection system Hilti HIT-HY 150 MAX

European Technical Approval ETA-13/0235

Machine devices, jig devices

European Technical Approval ETA-10/0005

Hilti, Inc South 122 nd East Avenue Tulsa, OK

HPM Rebar Anchor Bolt. For bolted connections. Technical Manual. European Technical Approval ETA-02/0006. Version: Peikko Group 01/2015

European Technical Approval ETA-12/0500

Operations and Instruction Manual Might Swivel - Part # Concrete and Steel Anchorage Connector ANSI Z ,000 lbs / 44kn

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued November 1, Legacy report on the 1997 Uniform Building Code

(English language translation, the original version is in French language) SPIT HIT M. Société SPIT Route de Lyon F BOURG-LES-VALENCE France

Ermächtigt u n d n o t i f i z i e r t gemäß Artikel 10 der Richtlinie des Rates vom 21. Dezember 1988 zur Angleichung

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

European Technical Approval ETA-11/0374

PPM High-Strength Anchor Bolt

Page 1 of Sven Alexander Last revised SB-Produksjon STATICAL CALCULATIONS FOR BCC 250

Connection Solutions

Technical Application Document. Hilti HIT-RE 500-SD

INSTRUCTIONS FOR USE

European Technical Assessment ETA-10/0153 of 10/06/2015

Integrated Manhole Ladder System

ASSEMBLY INSTRUCTIONS ACCORDING TO SAE J1453 FOR FLARED TUBES. 5. Clean properly with appropriate products the part of the tube to be flared.

Screw Thread Design. Rev

SERIES NG 1800 STRUCTURAL STEELWORK

Highly flexible couplings

Conceptual Design of Buildings (Course unit code 1C2)

EJOT Spiralform. The thread formers for metal. EJOT The Quality Connection

European Technical Approval ETA-98/0001

fischer Test Report Fixing Tests for Wienerberger Porotherm blocks

ANCHOR BOLTS FOR NUCLEAR POWER PLANT APPLICATIONS

High-performance, 2-part epoxy anchoring adhesive

ENGINEERING SCIENCE H1 OUTCOME 1 - TUTORIAL 3 BENDING MOMENTS EDEXCEL HNC/D ENGINEERING SCIENCE LEVEL 4 H1 FORMERLY UNIT 21718P

PC-Concrete Injectable Concrete Anchoring and Repair System

European Technical Approval ETA-10/0153

System. Stability. Security. Integrity. 150 Helical Anchor

European Technical Approval ETA-11/0024

Guidelines for Earthquake Bracing of Residential Water Heaters

Policy on Water Heater Installations Policy No. UPC Effective: September 1, 1995 Revised: February 10, 1996

LK Wallbox UNI Push. Assembly. Only intended for LK PE-X Universal Pipe X.

Fasteners and screw threads

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

CITY OF LOS ANGELES CALIFORNIA

Ermächtigt u n d n o t i f i z i e r t gemäß Artikel 10 der Richtlinie des Rates vom 21. Dezember 1988 zur Angleichung

Universal Installation and Maintenance Instructions Double Wall Spill Containment Bucket (5 and 15 gal)

DESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab,

The Effects of Hole Cleaning on Post-Installed Anchor Systems in Concrete

C E L CONSULTING A D I V I S I O N O F C O N S O L I D A T E D E N G I N E E R I N G FOR THE

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

AA Solar and Sun Power Plus

European Technical Approval ETA-06/0259

S OUNTING INSTRUCTION M M o u n t i n g k i t 2 &

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

Concrete Design Manual

DELTA PT. Calculable Extra Performance

MultiPost-AP anchorage device

English Version. Eurocode 2: Design of concrete structures - Part 4: Design of fastenings for use in concrete

Schöck Isokorb type KST User Selection Guide. Schöck Isokorb type KST Blindtext

European Technical Approval ETA-01/0013

DIVISION: EARTHWORK SECTION: BORED PILES REPORT HOLDER: HUBBELL POWER SYSTEMS, INC.

KIRÁLY TRADING KFT H-1151 Budapest Mogyoród útja tel: Clamps Clamping devices

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

Transcription:

Bolt version -G Threaded rod version -B Safety cap version Benefits - suitable for non-cracked and cracked concrete C 20/25 to C 50/60 - high loading capacity - force-controlled expansion - reliable pull-down of the part fastened - no rotation in hole when tightening bolt -SH Hexagonal socked head screws -SK Countersunk version Concrete Tensile zone Fire resistance Shock European Technical Approval CE conformity Hilti anchor design software Approvals / certificates Description Authority / Laboratory No. / date of issue European technical approval a) CSTB, Paris ETA-02/0042 / 2008-01-10 ICC-ES report ICC evaluation service ESR 1545 / 2005-08-01 Shockproof fastenings in civil Bundesamt für defence installations Bevölkerungsschutz, Bern BZS D 08-601 / 2008-06-30 Fire test report IBMB, Braunschweig UB 3041/1663-CM / 2004-03-22 Assessment report (fire) warringtonfire WF 166402 / 2007-10-26 a) All data given in this section according ETA-02/0042, issue 2008-01-10. Basic loading data (for a single anchor) All data in this section applies to - Correct setting (See setting instruction) - No edge distance and spacing influence - Concrete as specified in the table - Steel failure - Minimum base material thickness - Concrete C 20/25, f ck,cube = 25 N/mm² For details see Simplified design method 96 6 / 2010

Mean ultimate resistance Tensile N Ru,m [kn] 31,1 39,2 47,9 66,9 93,5 122,9 15,9 21,2 34,2 47,8 66,8 87,8 Shear V Ru,m, -B, -SK a), -SH a) [kn] 43,0 68,0 95,8 133,8 187,0 245,3 40,0 56,0 68,4 95,6 133,6 175,6 -G b) [kn] 36,1 48,1 75,1 118,5 187,0-36,1 48,1 68,4 95,6 133,6 - Characteristic resistance Tensile N Rk [kn] 23,4 29,5 36,1 50,4 70,4 92,6 12,0 16,0 25,8 36,0 50,3 66,1 Shear V Rk, -B, -SK a), -SH a) [kn] 31,1 49,2 71,7 100,8 140,9 177,4 30,1 42,2 51,5 72,0 100,6 132,3 -G b) [kn] 26,1 34,8 54,3 85,7 140,9-26,1 34,8 51,5 72,0 100,6 - Design resistance Tensile N Rd [kn] 15,6 19,7 24,0 33,6 47,0 61,7 6,7 10,7 17,2 24,0 33,5 44,1 Shear V Rd, -B, -SK a), -SH a) [kn] 24,9 39,4 48,1 67,2 93,9 123,5 20,1 28,1 34,3 48,0 67,1 88,2 -G b) [kn] 20,9 27,8 43,4 67,2 93,9-20,1 27,8 34,3 48,0 67,1 - Recommended loads Tensile N rec c) Shear V rec c) [kn] 11,2 14,1 17,2 24,0 33,5 44,1 4,8 7,6 12,3 17,1 24,0 31,5, -B, -SK a) a) [kn] 17,8 28,1 34,3 48,0 67,1 88,2 14,3 20,1 24,5 34,3 47,9 63,0, -SH -G b) [kn] 14,9 19,9 31,0 48,0 67,1-14,3 19,9 24,5 34,3 47,9 - a) -SK and -SH is only available up to M12 b) -G is only available up to M20 c) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001, annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions. 6 / 2010 97

Materials Mechanical properties of, -G, -B, -SH, -SK Anchor size M8 M10 M12 M16 M20 M24 Nominal tensile strength f uk [N/mm²] 800 800 800 800 830 830 Yield strength f yk [N/mm²] 640 640 640 640 640 640 Stressed cross-section A s [mm²] 36,6 58,0 84,3 157 245 353 Moment of resistance W [mm³] 31,3 62,5 109,4 277,1 540,6 935,4 Design bending resistance without sleeve M Rd,s [Nm] 24,0 48,0 84,0 212,8 415,2 718,4 Material quality Part Material Bolt, threaded rod steel grade 8.8 according ISO 898-1, galvanised to min. 5 µm Anchor dimensions Dimensions of, -G, -B, -SH, -SK Anchor Thread t fix [mm] d s l 1 l 2 l 3 l 4 [mm] version size [mm] [mm] [mm] [mm] min max min max M8 5 200 11,9 12 32 15,2 19 214 2 -G M10 5 200 14,8 14 36 17,2 23 218 3 p [mm] -G -B -B -SH -SK M12 5 200 17,6 17 40 20 28 223 3 M16 10 200 23,6 20 54,4 24,4 34,5 224,5 4 M20 10 200 27,6 20 57 31,5 51 241 4 M24 10 200 31,6 22 65 39 57 247 4 M8 5 11,9 12 32 15,2 19 2 M10 20 14,8 14 36 17,2 38 3 M12 25 17,6 17 40 20 48 3 M8 10 20 11,9 12 32 15,2 18,2 28,2 2 M10 20 14,8 14 36 17,2 32,2 3 M12 25 17,6 17 40 20 40 3 98 6 / 2010

Setting installation equipment Anchor size M8 M10 M12 M16 M20 M24 Rotary hammer TE2 TE16 TE40 TE70 Other tools hammer, torque wrench, blow out pump Setting instruction For detailed information on installation see instruction for use given with the package of the product. For technical data for anchors in diamond drilled holes please contact the Hilti Technical advisory service. Setting details: depth of drill hole h 1 and effective anchorage depth h ef Setting details M8 M10 M12 M16 M20 M24 Nominal diameter of drill bit d o [mm] 12 15 18 24 28 32 Cutting diameter of drill bit d cut [mm] 12,5 15,5 18,5 24,55 28,55 32,7 Depth of drill hole h 1 [mm] 80 90 105 125 155 180 d f [mm] 14 17 20 26 31 35 Effective anchorage depth h ef [Nm] 60 70 80 100 125 150 Torque moment T inst [mm] 25 50 80 120 200 250 Width across SW [mm] 13 17 19 24 30 36 6 / 2010 99

Setting details -G -G M8 M10 M12 M16 M20 Nominal diameter of drill bit d o [mm] 12 15 18 24 28 Cutting diameter of drill bit d cut [mm] 12,5 15,5 18,5 24,55 28,55 Depth of drill hole h 1 [mm] 80 90 105 125 155 d f [mm] 14 17 20 26 31 Effective anchorage depth h ef [mm] 60 70 80 100 125 Torque moment T inst [Nm] 20 35 60 80 160 Width across SW [mm] 13 17 19 24 30 Setting details -B -B M12 M16 M20 M24 Nominal diameter of drill bit d o [mm] 18 24 28 32 Cutting diameter of drill bit d cut [mm] 18,5 24,55 28,55 32,7 Depth of drill hole h 1 [mm] 105 125 155 180 d f [mm] 20 26 31 35 Effective anchorage depth h ef [mm] 80 100 125 150 Width across SW [mm] 24 30 36 41 The torque moment is controlled by the safety cap Setting details -SH -SH M8 M10 M12 Nominal diameter of drill bit d o [mm] 12 15 18 Cutting diameter of drill bit d cut [mm] 12,5 15,5 18,5 Depth of drill hole h 1 [mm] 85 95 110 d f [mm] 14 17 20 Effective anchorage Depth h ef [mm] 60 70 80 Torque moment T inst [Nm] 25 35 60 Width across SW [mm] 6 8 10 100 6 / 2010

Setting details -SK -SK M8 M10 M12 Nominal diameter of drill bit d o [mm] 12 15 18 Cutting diameter of drill bit d cut [mm] 12,5 15,5 18,5 Depth of drill hole h 1 [mm] 80 90 105 Diameter of countersunk hole in the d f [mm] 14 17 20 d h = [mm] 22,5 25,5 32,9 Effective anchorage Depth h ef [mm] 60 70 80 Torque moment T inst [Nm] 25 50 80 Size of hexagon socket screw key SW [mm] 5 6 8 Setting parameters Anchor size M8 M10 M12 M16 M20 M24 Minimum base material thickness h min [mm] 120 140 160 200 250 300 Minimum spacing s min [mm] 60 70 80 100 125 150 for c [mm] 100 100 160 240 300 300 Minimum edge c min [mm] 60 70 80 100 150 150 distance for s [mm] 100 160 240 240 300 300 Critical spacing for splitting failure Critical edge distance for splitting failure Critical spacing for concrete cone failure Critical edge distance for concrete cone failure s cr,sp [mm] 230 270 300 380 480 570 c cr,sp [mm] 115 135 150 190 240 285 s cr,n [mm] 180 210 240 300 375 450 c cr,n [mm] 90 105 120 150 187,5 225 For spacing (edge distance) smaller than critical spacing (critical edge distance) the design loads have to be reduced. Critical spacing and critical edge distance for splitting failure apply only for non-cracked concrete. For cracked concrete only the critical spacing and critical edge distance for concrete cone failure are decisive. 6 / 2010 101