GRUNDFOS INSTRUCTIONS. Maintenance-free circulators with line cord and optional timer control

Similar documents
INSTANT HOT WATER RECIRCULATING SYSTEM

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

MODEL INSTALLATION INSTRUCTIONS

Oil and Coolant Circulating Heating System. Model - OCSM

Float and Thermostatic Traps Series H, C and X

! WARNING. Before using product, read and understand instructions.

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Installation and Operation Guide for PD5100 Automatic Transfer Switch

CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page Phase Simplex Page 8-13

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

100 Series Maxi Internal Filters. Instruction Manual

Redi-Flo4. Stainless Steel Submersible Pumps for Environmental Applications GRUNDFOS INSTRUCTIONS. US Installation and operating instructions

Hydro MPC Integrated Pump Systems and HVAC Applications GRUNDFOS HYDRO MPC

LiteAide OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

STC 3S A Series Solenoid Valves

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

Mini-led spotlight with magnetic base

1/3 HP Submersible Sump Pump with Vertical Float Switch

Automatic Phone-Out Home Monitoring Systems

TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

Instructions and precautions. Fork Height. Visit our website at:

el-720 Carbon Dioxide Gas Leak Detector User s Guide

Dear Customer, User Memo: Please visit us on facebook or twitter! Thank you for purchasing this product.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

Bottom Loading Water Dispenser

4 in 1 Air Compressor

POOL SUNSHINE IONIZER MODELS SPD, SPD2 AND SPS INSTALLATION INSTRUCTIONS

SINGLE STAGE INLINE FIRE PUMP

Single Station Remote Alarm

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

Utility Distribution Systems

MODEL G300 BRAKE BLEEDER

Installation Manual DIAPHRAGM WELL TANK

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

SunMaxx Solar Filling Station Operating Instructions

APM HDC-4000 O PTICAL FIBER P OLISHING M ACHINE

Geocontrol PRO INSTALLATION AND OPERATION MANUAL. Rev. 1 03/18/04 Part #

ClearView 100. Instruction Manual

81000 Series Aluminum Gate Valve Installation and Repair Manual

Customer Support

Operator s Manual. Pressure Injection Cell Model PC8500. Congratulations! Contents

Wilo SP Series Submersible Sump Pumps ECS. ECS ECS ECS Installation and operating instructions

What you can expect from your Solar Hot Water System

Ultrasonic Jewelry/DVD Cleaner. make jewelry, dvds and more sparkle like new

LCD5500Z / PKP-LCD v3.x Installation Instructions

16/32 Channel 1U Rack Mount CCTV Power Supply

, User s Manual

Triple Threat 3-in-1 Game Table 3 IN 1 GAME TABLE

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS

Wafer Check Valve ASAHI AV VALVES. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Wireless Indoor/ Outdoor Thermometer

12V Portable Diaphragm Compressor Operating and Maintenance Instructions

JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS.

FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL

ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

OWNER S MANUAL BIG BEAR VORTEX FAN MODEL #BB-1 INTRODUCTION OPERATION SAFETY SERVICE WARRANTY CONTACT SPECIFICATIONS TROUBLESHOOTING

ELECTRIC KNIFE SHARPENER

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

Installation & Operation

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05


Installation, Operation, Repair and Parts Manual

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075

B-AIR BLOWER CUB POWER MODEL # CP-1

12-Volt 10-Amp Regulated Power Supply

PC1130 Electric Air Compressor

Mini Tank water heater Electric undersink Water heaters GL GL 4 - GL 6+

AM/FM PLL Clock/Table Radio

Home Owners Guide HR SERIES HEAT RECOVERY VENTILATOR (HRV) Models HR100V, HR160H & HR220H RESIDENTIAL USE ONLY HR160H & HR220H

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

MASTER. Water Conditioning Corp. MBA-10/13 FILTERS with the 253/742 Logix Control Valve. Installation and Operation Manual.

PC1131 Electric Air Compressor

Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use. OWNER S MANUAL Read and save these instructions before use.

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Ceiling Mount Air Handler Manual

USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model #

Advantium 2 Plus Alarm

Rules for Safe Operation

Owner s Manual. Pelican Custom Premium WHWF 1865/2162

Electric Water Heater

Alarm Clock USER GUIDE

INSTALLER S & OWNER S MANUAL

CTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual

ATS Overhead Table Shelf System INSTRUCTION MANUAL

DUST COLLECTOR 70 GALLON, 2 HP

HPU14M-DS 2013 Daniels Manufacturing Corp., All Rights Reserved Page 1 of 17 REV. C 7/2013

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

Transcription:

GRUNDFOS INSTRUCTIONS Maintenance-free circulators with line cord and optional timer control Installation & operating instructions Shipment inspection...page 2 Pre-installation checklist...page 2 Pump installation...page 3 Electrical...page 5 Timer control technical data and application...page 5 Timer operation...page 6 Failure to operate...page 7 Warranty...page 8

1. Shipment inspection Examine the components carefully to make sure no damage has occurred to the pump during shipment. Care should be taken to ensure the pump is NOT dropped or mishandled; dropping will damage the pump. 2. Pre-installation checklist Before beginning installation procedures, the following checks should be made. They are all important for proper installation of the circulator pump. 1. Uses: Model UP(S) 15 series pumps are designed to circulate water from 36 F to 230 F (UPS 15-35 from 36 F to 165 F) up to a maximum pressure of 145 PSI. If required, a 50% by volume solution of ethylene or propylene glycol and water can be used, however, a PSI decrease in pump performance may result due to an increase in the viscosity of the solution. Check with manufacturer for information regarding suitability of pumping other fluids. System applications: UP(S)15 series pumps with stainless steel or bronze volutes can be used in both open and closed systems. 2. Maximum water temperature: UP(S)15 pump with line cord only. The maximum allowable water temperature is determined by the ambient or surrounding air temperature as shown in Table 2A. Table 2A Maximum water temperature Ambient ( F) 95 130 140 160 175 Water ( F) 230 220 210 190 175 Although the pump is designed to operate at maximum water temperature of 230 F, it is recommended to keep the operating temperature as low as possible (i.e. below 140 F to avoid precipitation of calcium). Note: UP15(S) pump with timer control maximum water temperature: 150 F 3. Inlet pressure requirements The amount of pressure required at the inlet of the pump is a function of the temperature of the water as shown in Table 2B.

Table 2B Inlet Pressure Requirements Water ( F) 190 165 140 Required Inlet Pressure (ft.) 5 4.5 3 (PSI) 2.2 1.9 1.3 In a pressurized system, the required inlet pressure is the minimum allowable system pressure. In an open system, the required inlet pressure is the minimum distance the pump must be located below the lowest possible water level of the water source (tank, pool, etc.). 3. Pump installation Position of terminal box: Proper installation of the pump will have the terminal box located to one side of the pump or the other, with the conduit entry down. See Figure 3A. Figure 3A Recommended Terminal Box Orientation If the terminal box position needs to be changed, it is best to do so before installation. However, if the pump is already installed, ensure that the line cord is unplugged and close the isolation valves before removing the Allen screws. To change terminal box position: 1. Remove the four (4) Allen screws from the pump housing and stator (4 or 5mm wrench) while supporting the stator (motor). 2. Carefully separate the stator from the pump housing and rotate it to the correct terminal box orientation and reseat it. 3. Replace the Allen screws and tighten diagonally and evenly (7 ft.-lb. torque). 4. Check that the motor shaft turns freely. Remove the large screw in the middle of the nameplate, insert a small flat blade screwdriver into the end of the shaft, and turn gently (see fig. 7a). If the shaft does not turn easily, repeat the disassembly/reassembly process.

NOTE: UPS15-42 does not require manual turning of shaft. Pump mounting: For indoor use Arrows on the side or bottom of the pump housing indicate direction of flow through the pump. GRUNDFOS circulators can be installed in both vertical and horizontal lines. The pump must be installed with the motor shaft positioned horizontally. Under no circumstances should the pump be installed with the shaft vertical or where the shaft falls below the horizontal plane. See Figure 3B. Figure 3B Acceptable Unacceptable It is recommend that isolation valves be installed on each side of the pump. If possible, do not install elbows, branch tees, and similar fittings just before or after the pump. Provide support to the pump or adjacent plumbing to reduce thermal and mechanical stress on the pump. Installation requirements 1. Thoroughly clean and flush the system prior to pump installation. 2. Do not install the pump at the lowest point of the system where dirt and sediment naturally collect. 3. Install an air vent at the high point(s) of the system to remove accumulated air. 4. Ensure that water does not enter the terminal box during the installation process. 5. (Open System) Install the pump in the supply line; the suction side of the pump should be flooded with water. Ensure that the static head requirementfrom Table 2B is achieved. 6. (Closed System) Install a safety relief valve to protect against temperature and pressure build-up. 7. If there are excessive suspended particles in the water, it is recommended that a strainer and/or filter be installed and cleaned regularly. 8. DO NOT START THE PUMP UNTIL THE SYSTEM HAS BEEN FILLED AND CHECKED FOR LEAKS OR OTHER POSSIBLE COMPONENT FAILURES.

4. Electrical CAUTION: Do not energize pump until properly installed Warning - Risk of electrical shock - This pump is supplied with a grounding conductor. To reduce the risk of electric shock, be certain that it is connected only to a properly grounded grounding type receptacle. The safe operation of this pump requires that it be grounded in accordance with the National Electrical Code and local governing codes and regulations. Electrical requirements The operating voltage and other electrical data are marked on the motor label. Make sure that the motor is suitable for the electrical supply on which it will be used. Electrical connection Insert the 115V plug on the line cord from the pump into a properly grounded 115V outlet as shown in Figure 4a. 5. Timer technical data TIMER CONTROL Supply Voltage: 115-120 VAC, 60 hertz Contact Rating: 16 amps Ambient Temperature: -4 F to 175 F Max Fluid Temperature: 150 F Shortest Switching Interval: 15 minute increment Switch Modes: Timer, ON Override, OFF Override Protection: Clear plastic cover for dust and moisture protection of the clock face. 6. Timer technical application The Grundfos timer control is designed only for use with specified Grundfos Series UP circulators installed in indoor hot water service systems. The timer control is designed to turn the circulator on and off at preset times, allowing the user to select operation of the circulator during high use periods of the day.

7. Timer operation Setting and operating the timer control and starting the pump Figure 6a PROGRAMMING RING TIMING ARROW MANUAL SWITCH PROGRAMMING TABS NOTE: Before the circulator is started, the system must be filled with liquid and vented. 1. Set the timer switch to the actual time by turning the programming ring in the direction of the arrow until the timing arrow points to the actual time on the ring. 2. Switch on the power supply to the circulator and set the manual switch to the ON position. The circulator will now start. 3. Set the required ON / OFF times on the programming ring by pushing the programming tabs either away from or toward the center of the ring. Tabs pushed away from the center indicate the circulator is switched ON while tabs pushed toward the center indicate the circulator is switched OFF. Figure 6b 4. Set the manual switch to the TIMER posi tion. The circulator will now start/stop accord ing to the settings of the programming tabs.

5. For continuous operation, set the manual switch to the ON position. To switch the circulator off, set the manual switch to the OFF position. The ON / OFF modes may be used without affecting the function of either the programming ring or the timer switch. 6. In case of power outage the timer will not keep time. After power has been restored, the correct time of day must be reset by rotating the programming ring in the direction of the arrow until the timing arrow points to the actual time on the ring. 8. Changing speeds with timer option Disconnect line cord from system power. Remove (2) timer cover screws. Gently rotate speed selection stim to desired speed (see Figure 7a). Re-install (2) timer cover screws. 9. Troubleshooting Figure 7a When the pump is first started, the shaft may rotate slowly until water has fully penetrated the bearings. If the pump does not run, the shaft can be rotated manually. To accomplish this, switch off the electrical supply, and close the isolation valves on each side of the pump. Remove the large screw in the middle of the nameplate. Insert a small flat blade screwdriver into the end of the shaft, and gently turn until the shaft moves freely (see Figure 8a). Replace and tighten the plug. Open the isolation valves and wait 2 to 3 minutes for the system pressure to equalize before starting the pump. Figure 8a

10. Limited warranty Products manufactured by GRUNDFOS PUMPS CORPORATION (GRUNDFOS) are warranted to the original user only to be free of defects in material and workmanship for a period of 24 months from date of installation, but not more than 30 months from date of manufacture. GRUNDFOS liability under this warranty shall be limited to repairing or replacing at GRUNDFOS option, without charge, F.O.B. GRUNDFOS factory or authorized service station, any product of GRUNDFOS manufacture. GRUNDFOS will not be liable for any costs of removal, installation, transportation, or any other charges which may arise in connection with a warranty claim. Products which are sold but not manufactured by GRUNDFOS are subject to the warranty provided by the manufacturer of said products and not by GRUNDFOS warranty. GRUNDFOS will not be liable for damage or wear to products caused by abnormal operating conditions, accident, abuse, misuse, unauthorized alteration or repair, or if the product was not installed in accordance with GRUNDFOS printed installation and operation instructions. To obtain service under this warranty, the defective product must be returned to the distributor or dealer of GRUNDFOS products from which it was purchased together with proof of purchase and installation date, failure date, and supporting installation data. Unless otherwise provided, the distributor or dealer will contact the GRUNDFOS factory or authorized service station for instructions. Any defective product to be returned to the factory or service station must be sent freight prepaid; documentation supporting the warranty claim and/or a Return Authorization must be included if so instructed. GRUNDFOS WILL NOT BE LIABLE FOR ANY INCIDENTAL OR CON- SEQUENTIAL DAMAGES, LOSSES, OR EXPENSES ARISING FROM INSTALLATION, USE, OR ANY OTHER CAUSES. THERE ARE NO EXPRESS OR IMPLIED WARRANTIES, INCLUDING MERCHANT- ABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WHICH EX- TEND BEYOND THOSE WARRANTIES DESCRIBED OR REFERRED TO ABOVE. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages and some jurisdictions do not allow limitations on how long implied warranties may last. Therefore, the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from jurisdiction to jurisdiction. Grundfos Pumps Corporation 17100 W.118th Terrace Olathe, Kansas 66061 Telephone: (913) 227-3400 Fax: (913) 227-3500 Grundfos Canada, Inc. 2941 Brighton Rd. Oakville, Ontario L6H 6C9 Telephone: (905) 829-9533 Fax: (905) 829-9512 www.grundfos.com L-UP-TL-018 Rev. 08.11 PRINTED IN USA Bombas Grundfos de Mexico, S.A. de C.V. Boulevard TLC #15, Parque Industrial Stiva Aeropuerto C.P. 66600 Apodaca, N.L. Mexico Telephone: 52-81-8144-4000 Fax: 52-81-8144-4010