Powering HP BladeSystem c7000 Enclosures, 2 nd edition

Similar documents
QuickSpecs. HP Modular Power Distribution Units (Zero-U/1U Modular PDUs) Overview

QuickSpecs. HP 480/277 Volt Solutions. Overview

QuickSpecs. HP Managed Power Distribution Units (mapdu) Overview

QuickSpecs. Overview. HP Power Distribution Rack. HP Power Distribution Rack. DA North America Version 5 August 22, 2008 Page 1

How To Upgrade An Hp Power Distribution Rack To A Power Distribution Unit

QuickSpecs. HP R/T3000 G2 Uninterruptible Power System (UPS) Overview

HP R/T3000 G2 Uninterruptible Power System (UPS) Overview

QuickSpecs. HP Fixed Cord PDUs & Extension Bars (Zero-U/1U Modular PDUs) Overview

QuickSpecs. HP Remote Monitored Power Distribution Units (mpdu) Overview

QuickSpecs. Models HP T1500 UPS JPN/TWN. HP UPS T1000 G2, T1500 G2 Models Overview

HP UPS R1500 Generation 3

HP UPS Management Module Overview

R5000 Uninterruptible Power System (UPS) Overview

R5000 Uninterruptible Power System (UPS) Overview

HP Power Advisor utility: a tool for estimating power requirements for HP ProLiant server systems

QuickSpecs. Models HP Server Console Switches

Calculating power requirements for HP ProLiant rack-mounted systems

QuickSpecs. Models. HP UPS Management Module. HP UPS Management Module. Overview

HP PDU Management Module Overview

Power distribution in data centres

HP Server Console Switch with Virtual Media Overview

HP Designjet L65500 printer series Site preparation checklist (second edition)

Using HP ProLiant Network Teaming Software with Microsoft Windows Server 2008 Hyper-V or with Microsoft Windows Server 2008 R2 Hyper-V

QuickSpecs. HP IP Console Switch with Virtual Media Overview

HP ProLiant power supply technology

HP rack and power infrastructure products are designed and developed to be used specifically with HP servers and storage.

Wireless Networks and Power Quality

Distributing Power to Blade Servers

Increase the efficiency of power distribution in your high-density data center

QuickSpecs. Models HP Server Console G2 Switch. HP Server Console Switch G2 with Virtual Media & CAC. Overview

Server Technology Intl.

Efficiency and Other Benefits of 208 Volt Over 120 Volt Input for IT Equipment

Rack Power Distribution

Scitex FB550 and FB750 Printers. Site Preparation Checklist

Power Distribution Systems for the Dell PowerEdge M1000e Modular Server Enclosure - Selection and Installation

Rack Power Distribution. Worldwide

QuickSpecs. HP Smart Array 5312 Controller. Overview

How To Power A Power Supply Shelf With A Power Unit (Hp 2920)

Memory Modules User Guide

HP ProLiant Essentials Performance Management Pack 3.0 Support Matrix

QuickSpecs. What's New. Models. ProLiant Essentials Server Migration Pack - Physical to ProLiant Edition. Overview

HP Support Plus Service

Packet Power. Data Center Solutions. Packet Power for Data Centers. Benefits. Features. The Packet Power Solution. Data Center Monitoring Made Easy

QuickSpecs. What's New HP 750GB 1.5G SATA 7.2K 3.5" Hard Disk Drive. HP Serial-ATA (SATA) Hard Drive Option Kits. Overview

Three-Phase Electric Power Distribution for Computer Data Centers

HP OneView Administration H4C04S

QuickSpecs. HP IP Console Switches. Overview

HP Software as a Service

Fundamentals of Power

Power efficiency and power management in HP ProLiant servers

How To Write An Article On An Hp Appsystem For Spera Hana

HP ProLiant DL380 G5 High Availability Storage Server

End-to-end management

QuickSpecs HP TFT7600 G2 KVM Console and Monitor (TFT7600 G2)

QuickSpecs. HP Serial-ATA (SATA) Entry (ETY) and Midline (MDL) Hard Drive Option Kits. Overview

QuickSpecs. What's New New GB Pluggable Ultra320 SCSI 15,000 rpm Universal Hard Drive (1") HP SCSI Ultra320 Hard Drive Option Kits (Servers)

QuickSpecs. HP SATA Hard Drives. Overview

HP Common Slot power supply technology

HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install

Increasing Data Center Efficiency by Using Improved High Density Power Distribution

Server Virtualization with Windows Server Hyper-V and System Center (20409) H8B93S

HP Smart Array 5i Plus Controller and Battery Backed Write Cache (BBWC) Enabler

The Different Types of AC Power Connectors in North America

ProLiant Essentials Intelligent Networking Active Path Failover in Microsoft Windows environments

HP Roar Plus Speaker. Other Features

Assessing RAID ADG vs. RAID 5 vs. RAID 1+0

HP recommended configuration for Microsoft Exchange Server 2010: ProLiant DL370 G6 supporting GB mailboxes

Sharing Pictures, Music, and Videos on Windows Media Center Extender

Memory Modules. Document Part Number: This guide explains how to replace and upgrade memory in the computer.

QuickSpecs. What's New HP 3TB 6G SAS 7.2K 3.5-inch Midline Hard Drive. HP SAS Enterprise and SAS Midline Hard Drives. Overview

HP 16/18-Port Cable Management Kit Installation Guide

HP LeftHand SAN Solutions

ZONIT POWER DISTRIBUTION SYSTEM ORDER CATALOG

High-Efficiency AC Power Distribution for Data Centers

QuickSpecs. HP StorageWorks Direct Backup Engine for Tape Libraries. Extended Tape Library Architecture (ETLA) Family. Models.

Interface Adapters PS/2 Interface Adapter 1 pack B21 PS/2 Interface Adapter 8 pack B21 USB Interface Adapter 1 pack B21

QuickSpecs. Models. HP StorageWorks Modular Smart Array 50 Enclosure. HP StorageWorks Modular Smart Array 50 Enclosure. Overview

QuickSpecs. HP SAS Enterprise and SAS Midline Hard Drives Overview

HP Hardware Support Onsite 6-Hour Call-to-Repair Service

HP recommended configuration for Microsoft Exchange Server 2010: HP LeftHand P4000 SAN

Is your data center ready for virtualization?

HP Cloud Map for TIBCO ActiveMatrix BusinessWorks: Importing the template

QuickSpecs. HP Managed and Unmanaged Notebook Charging Carts. Models HP 30-Notebook Charging Cart

HP Hardware Support Onsite 6-Hour Call-to-Repair Service - U.S.

Where do you put 1,000,000,000,000 DNA base pairs? Could you quickly find one CT scan in a million?

HP Managed and Unmanaged Notebook Charging Carts Overview. Models HP 30-Notebook Charging Cart. HP 30-Notebook Managed Charging Cart

HP Server Integrations with Microsoft System Center Products Support Matrix

HP Point of Sale (POS) Peripherals Configuration Guide ap5000 VFD Windows (non-opos)

HP ThinPro. Table of contents. Connection Configuration for RDP Farm Deployments. Technical white paper

HP 36-Port InfiniBand Switch Cable Management Kit Installation Guide

QuickSpecs Windows Small Business Server 2011

Models HP IMC MPLS VPN Software Module with 50-node E-LTU

HP Common Slot Power Supplies Overview

Model #: SMART2200CRMXL

New Advanced RAID Level for Today's Larger Storage Capacities: Advanced Data Guarding

Bluetooth Pairing. User Guide

Transcription:

Powering HP BladeSystem c7000 Enclosures, 2 nd edition HOWTO Abstract... 2 Power draw of HP BladeSystem c7000 Enclosure... 2 Power Distribution... 2 Uninterruptible Power Supplies... 6 For more information... 9 Call to action... 9

Abstract This paper is intended to provide a short overview of the steps and components necessary to meet the power needs of HP BladeSystem c7000 Enclosures in a typical environment. Power draw of HP BladeSystem c7000 Enclosure The HP BladeSystem c7000 Enclosure is an Enterprise class computing platform. It is usually installed in data centers that have redundant power feeds from the electrical power provider. Usually these data centers also have large battery back-up systems (UPS) and electrical power generators capable of providing power to the entire facility. Typically power consumption is measured in Volt-amps (VA), in Kilo Volt-amps (kva), and in wattage (W). In discussing power distribution, this document expresses power measurements in VA. When fully configured and under extreme loads, the HP c7000 BladeSystem Enclosure can draw more than 8000 VA of power. However, with typical customer configurations and loads, a c7000 enclosure would only require 4000 VA to 6000 VA. Since the power draw of the system is dependent on its configuration and loading, HP strongly recommends using the HP Power Calculator to estimate the power draw of a BladeSystem configuration prior to purchase. After purchase, the built-in power meter on the c7000 enclosure will provide accurate power consumption measurements indicating the true loading. Other essential information is whether the c7000 enclosure will use single-phase low-voltage (100V to 120V), single-phase high-voltage (200 to 240V), or three-phase power. HP strongly recommends that all large BladeSystem configurations use single-phase high-voltage power or three-phase power. The most popular configuration is single-phase high-voltage power. Power Distribution The single-phase c7000 enclosure can support up to six power supplies, each requiring its own 16 A power cord. These cords must be attached to one or more rack level power distribution units (s) as illustrated in Figures 1 and 2. A is a high-grade component, much like a power strip, that allows attaching multiple power cables to a single high-power input feed that supplies all the equipment in the rack. s improve cable management inside and outside the rack and reduce cable clutter under the raised floor of a data center. HP offers s that can be connected to either single-phase or three-phase power input feeds, but in both cases the connections to the servers (outputs) would be single-phase. c7000 enclosures do not require in-rack s and should be connected directly to facility power using a pair of the appropriate three-phase receptacles (NEMA L15-30p or IEC 309 5-Pin RED). For redundancy, HP recommends that critical components such as servers and BladeSystem enclosures use redundant power supplies that are supplied by separate power feeds and s inside the rack. 2

Figure 1. Single HP BladeSystem c7000 Enclosure using HP s Figure 2. Multiple HP BladeSystem c7000 Enclosures using HP s 3

Table 1 lists supported power distribution configurations for single-phase c7000 enclosures. All HP power protection and distribution products come standard with a 3-year warranty and are automatically covered by Care Packs on HP ProLiant servers and BladeSystem enclosures in the same rack. Table 1. Power distribution configurations for single-phase HP BladeSystem c7000 Enclosures Number of Enclosures Total VA requirements Single-phase power only available to power s power available to power s Recommended and quantity needed for redundancy Maximum capacity of each Receptacles required (supplied by customer) North America/Japan 1 Less then 5kVA Yes No 2 x 252663- D74, 24A 4.9kVA NEMA L6-30R 1 Greater than 5kVA Yes No 2 x 252663- D75, 40A 8.3kVA Non-NEMA CS8264C 1 Greater than 5kVA N/A Yes 2 x AF512A Three 8.6kVA NEMA L15-30R 4kVA each Yes No 4 x 252663- D75, 40A 8.3kVA Non-NEMA CS8264C 4kVA each N/A Yes 2 x AF512A Three 8.6kVA NEMA L15-30R 2 Less then 5kVA each Yes No 4 x 252663- D74, 24A 4.9kVA NEMA L6-30R 2 Greater than 5kVA each N/A Yes 4 x AF512A 24A Three Modular 8.6kVA NEMA L15-30R 2 Greater than 5kVA each N/A Yes 2 x AF519A 40A Three Modular 14.4kVA Hubbell CS8364C 4 8kVA each N/A Yes 2 x AF511A 48A Three Modular 17.3kVA 60A, 4 7kVA each N/A Yes 2 x AF536A 40A Three 14.4kVA Hubbell CS8364C 4 4

Table 1 Continued. Power distribution configurations for single-phase HP BladeSystem c7000 Enclosures Number of Enclosures Total VA requirements Single-phase power only available to power s power available to power s Recommended and quantity needed for redundancy Maximum capacity of each Receptacles required (supplied by customer) 8kVA each N/A Yes 2 x AF916A 48A Three 17.3kVA 60A, 4 3 Less than 5.75kVA each N/A Yes 2 x AF916A 48A Three 17.3kVA 60A, 4 4 Less than 4.3kVA each NA Yes 2 x AF916A 48A Three 17.3kVA 60A, 4 4 Less than 7kVA each N/A Yes 4 x AF536A 40A Three 14.4kVA Hubbell CS8364C 4 International 1 Less than 7kVA each 2 Up to 4.5kVA each 5.5kVA each Yes N/A 2 x 252663- B33 32A Yes N/A 2 x 252663- B34 40A N/A Yes 2 x AF513A 16A 7.3 kva 32A 9.2kVA 11kVA 63A 16A, 5 wire, 4 pole 3 Up to 7kVA each N/A Yes 2 x AF917A 32A 22kVA 32A, 5 wire, 4 pole 4 Less than 5.5kVA each N/A Yes 2 x AF917A 32A 22kVA 32A, 5 wire, 4 pole 5

Uninterruptible Power Supplies Some data center operators may desire the added protection of rack mounted Uninterruptible Power Systems (UPSs) to help protect HP BladeSystem components from power outages, brown outs, and unstable voltage situations. HP UPS systems provide protection from these and many other potential power issues that could cause data loss. The UPSs can also initiate graceful shut downs of multiple servers in the event of an extended power loss. For c7000 enclosures HP recommends the HP R8000/3 and R12000/3 three-phase UPS systems. Because the HP R8000/3 and R12000/3 UPS systems include the HP UPS Management Module, a dedicated management server is not needed. The HP UPS Management Module allows an HP three-phase UPS to be easily and securely managed from a web browser and to send alerts. The UPS Management Module also supports clustered UPS systems. The R8000/3 UPS has one three-phase input and one three-phase output designed to go to either an 8.6kVA, 24A, threephase modular to support a singlephase BladeSystem enclosure (Figure 3) or directly to one of the three-phase inputs on a three-phase BladeSystem enclosure. Figure 4 illustrates providing redundant UPS support to a c7000 enclosure. Figure 3. R8000/3 UPS with connected to a single-phase BladeSystem c7000 enclosure Figure 4. Two R8000/3 UPSs provide redundant support to a three-phase BladeSystem c7000 6

Alternately the R12000/3 has two three-phase outputs so it can be configured to support one or two enclosures (Figure 5). Figure 5. Sample configurations of R12000/3 UPSs to c7000 enclosures One R12000/3 to a three-phase BladeSystem c7000 Enclosure Two R12000/3 to 2 three-phase BladeSystem c7000 Enclosures R12000/3 with two three-phase s to 2 single-phase BladeSystem c7000 Enclosures 7

Table 2 lists supported power distribution configurations for single-phase c7000 enclosures. All HP power protection and distribution products come standard with a 3-year warranty and are automatically covered by Care Packs on HP Proliant servers and BladeSystem enclosures. Table 2. Supported UPS configurations for HP BladeSystem c7000 Enclosures Number of enclosures Single- or three-phase c7000 enclosure UPS Choice required Maximum power draw per enclosure Plug required (suppied by customer) North America/Japan 1 Single R8000/3, #AF431A 2 Single R12000/3 #AF429A 1 x AF512A 2 x AF512A 8kVA NEMA L21-30 6kVA 60A, 4 1 Three R12000/3 #AF429A 2 Three R12000/3 #AF429A N/A >8kVA 60A, 4 N/A 6kVA 60A, 4 International 1 Single R8000/3, #AF432A 2 Single R12000/3 #AF430A 1 x AF513A 2 x AF513A 8kVA 16A, 5 wire, 4 pole 6kVA 32A, 5 wire, 4 pole 1 Three R12000/3 #AF430A 2 Three R12000/3 #AF430A N/A >8kVA 32A, 5 wire, 4 pole N/A 6kVA 32A, 5 wire, 4 pole 8

For more information For additional information, refer to the resources listed below. Resource description White paper: Increasing energy efficiency with modular HP three-phase power distribution HP Power Calculators HP UPS Sizing tool Web address http://h20000.www2.hp.com/bc/docs/support/supp ortmanual/c01173322/c01173322.pdf?jumpid=reg_ R1002_USEN http://h30099.www3.hp.com/configurator/calc/powe r%20calculator%20catalog.xls http://www.upssizer.com/ Call to action For additional assistance please send a detailed email to: North and South America: Rackandpoweramericas@hp.com. Europe, Mid-east, and Africa: Rackandpowersolutions@hp.com Copyright 2008 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. TC090110HT, January 2009