Construction. SikaQuick Application Instructions. Sika Corporation

Similar documents
ARDEX GUIDE SPECIFICATION ARDEX Exterior Concrete Repair & Resurfacing Polymer-Modified, Cement-Based, Patch & Horizontal Overlay Materials

Concrete Repair. Applications and Procedures

SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION CONCRETE BONDING COMPOUND.

MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS

Resurfacing Concrete. Page 1 of 5

Proper use of the Rebound Hammer Updated to reflect the changes to ASTM C805

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

SECTION RESURFACING CAST IN PLACE CONCRETE

Construction. Pre-Bagged Structural Waterproofing System. Product Description. Product Data. Tests. Form

LOWELL REGIONAL WASTEWATER UTILITY SPECIFICATIONS FOR THE LOWELL MA CONCRETE FLOODWALL REPAIRS

K2 STONE NATURAL VENEER

LAYING BLOCK AND BRICK

Sikaflex Sealant Installation. Sika Corporation

MINIMUM QUALITY CONTROL PLAN FOR FIELD PLACEMENT OF LATEX MODIFIED MORTAR OR CONCRETE WEARING SURFACE

MASONRY RESTORATION Lime Putty Mortar Repointing Guide

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

CORROSION ENGINEERING RESIN-BASED POLYMER CONCRETES AND GROUTS

FIVE STAR PRODUCTS, INC. (800)

Minor Cracks in Horizontal Surfaces

Mineral waterproof coating PCI Dichtschlämme

kalox-pool draft 231 repairing refurbishing and finishing KALOX-POOL Waterproof cement-based mortar for protecting and finishing concrete.

VIRGINIA DEPARTMENT OF TRANSPORTATION MATERIALS DIVISION MEMORANDUM

CA-48 TECHNICAL SPECIFICATION

The AQUAFIN Approach to Concrete Repair

Guidelines for Durable Driveways, Carports Patios, Walks, Garage Floors

SECTION POLISHED CONCRETE FINISHING

Bonding Agents: The Good, the Bad, and What Works. Bond with Your Concrete

BRIDGE REHABILITATION. Maintaining and Repairing Existing Structures

These recommendations generally follow the Construction Specifications Institute (CSI) Master Format.

PRE INSTALLATION MANUAL

Free-Form Concrete Pool

INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

International Greenhouse Company

738-B-297 POLYMERIC CONCRETE BRIDGE DECK OVERLAY. (Adopted )

September 1, 2003 CONCRETE MANUAL CONCRETE PAVEMENT REHABILITATION

TECHNICAL SPECIFICATIONS CONCRETE SIDEWALKS, DRIVEWAYS AND CURB AND GUTTER

WATERPROOFING OF WET ROOMS

The minimum reinforcement for the stem wall is the placement of:

SC2000 CEMENT BONDING PROCEDURES

The Minnesota Lath and Plaster Bureau Repairing Cracks in Stucco

Seven. Easy Steps. Your Own Walkway, Without Mortar. or Concrete. to Installing. Driveway and Patio

The existing roof angle change terminations and flashings when sound and intact can be reused.

AC Tech Project Survey

Laying the First Course. 1. Excavate the site and construct the footing.

cement Masonry Cement Engineered for quality and reliability, Lafarge cements for masonry deliver consistent performance. page 2 Lafarge Cement

Chapter. Restoration of Damaged Structures

NAPCA BULLETIN APPLICATION PROCEDURES FOR CONCRETE WEIGHT COATING APPLIED BY THE COMPRESSION METHOD TO STEEL PIPE

Technical Advice Note

NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS

Surface Engineering Solutions Rebuild, Repair and Protect Industrial Equipment

SECTION 1 GENERAL REQUIREMENTS

STANDARD SPECIFICATIONS SECTION PRECAST REINFORCED CONCRETE MANHOLES AND MANHOLE BASES. 1. Structure Earthwork: 02200

Foundations 65 5 FOUNDATIONS. by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. Seismic Retrofit Training

SECTION CAST-IN-PLACE CONCRETE

BEST PRACTICE GUIDE. Fibrelime Premixed Universal Plaster and Render

External Wrapping of Steel Riser Pipe. Case Study HJ3 CS200902

Construction. Sikadur-Combiflex. Sealing system for cracks and problem joints with large movements DESCRIPTION

Concrete Removal Using Hydrodemolition

PRECAST CONCRETE ARCHITECTURAL REPAIR GUIDE

ExTERNAL BASEMENT WATERPROOFING

Metropolitan Builders Association Masonry & Concrete Standard

Construction of Quality Hot Mix Asphalt Pavements

Concrete Resurfacing. System Guide. by Parchem Construction Supplies

ELASTOCEM. Technical features. Applications. Two-component flexible, waterproofing and protective cementitious grout.

STRUCTURES Excavation and backfill for structures should conform to the topic EXCAVATION AND BACKFILL.

Sample Specification Guideline for Installing a Polished Overlay Using Rapid Set TRU Self-Leveling SECTION POLISHED CONCRETE TOPPING

ALKALI-RESISTANT WATERPROOFING AND DECOUPLING MEMBRANE UNDER CERAMIC TILES AND NATURAL STONE

external Basement waterproofing

A. This Section includes rubberized asphalt sheet membrane waterproofing systems.

Saint Gobain Gyproc India Ltd. (Formerly India Gypsum Ltd.)

Photographs: Acceptable, Unacceptable, and Unacceptably Repaired Precast Concrete Products

PTS HELICAL PIERS INSTALLATION SPECIFICATIONS NOTICE

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 888 PORTLAND CEMENT CONCRETE PAVEMENT USING QC/QA.

How to Install GoBoard:

Guide Specification Precast Concrete Products

GigaCrete Specification PlasterMax

Secondary Containment Comparison ATI Ultra COAT vs HDPE

Installation System. Existing Resilient Sheet Floors

Chockfast Red HF Epoxy Grout

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

Installation PowerPoint for Grasscrete Formers

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

Specification for Pipe Coating Repairs Offshore

CGA Standard Practices Series. Article 600 Standard for Pozzolan Enhanced Grouts Used in Annular Seals & Well Destruction

SECTION XXXXXX TECHNICAL SPECIFICATIONS FOR INSTALLATION OF PROTECTIVE COATINGS FOR MANHOLES, WETWELLS, AND OTHER SANITARY SEWER STRUCTURES

White rust on galvanized and galvanized pre-painted steel. Technical Information

SECTION 4Aggegate Subbase

Product Systems AQUAFIN-IC CEMENTITIOUS CRYSTALLINE PENETRATING WATERPROOFING. Waterproofing Specification

STUCCOMAX Installation Specifications Exterior One-Coat Stucco over EPS Foam, PU Foams, Exterior Gypsum Board, MgO Board and Cement Block

Wastewater Capital Projects Management Standard Construction Specification

3-part cement and epoxy combination mortar for self-smoothing floor screeds of 3 to 7 mm

NEGATIVE SIDE WATERPROOFING SYSTEMS FOR MASONRY AND CONCRETE

Vinyl Composition Tile Installation System

WATERPROOFING FOR CONCRETE STRUCTURES

METHOD A10 (a) THE DETERMINATION OF THE IN-PLACE DRY DENSITY OF SOIL OR GRAVEL BY THE SAND REPLACEMENT METHOD

Wecryl Waterproofing System under surfacing supplied by others

Standard Method for Sampling and Analysis of. of Chlorine Containing Bleaches. Soap Products

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

3 Masonry and Manufactured Stone (Interior and Exterior)

Transcription:

SikaQuick 1000 Application Instructions

SikaQuick 1000 Rapid Hardening Repair Mortar with Extended Working Time. Sika Quick is a 1-component,rapid hardening, early strength gaining cementitous based material for patching concrete.

SikaQuick 1000 Where to use: Use on grade, above and below grade on concrete. Highway overlays and repairs. Structural Repair material for concrete roadways, parking structures, bridges, dams and ramps. Full depth patching. Economical patching material for horizontal repairs of concrete and mortars.

Coverage: SikaQuick 1000 SikaQuick 1000 Mortar Approximately 0.43 cu.ft SikaQuick 1000 Concrete When extended with 25 lbs. of 3/8 in gravel approximate yield = 0.6 cu.ft

Packaging: 50 lb Multi wall Bag 40 Bags/Pallet SikaQuick 1000

Surface Preparation Cementitious Substrates: 1. Should be clean and sound. 2. Remove contaminations and bond inhibiting materials from repaired area. 3. Obtain exposed/fractured aggregate surface ~1/8 to 1/4 inch profile (ICRI CSP 6 & above). 4. Substrate must be saturated surface dry (SSD) with no standing water.

Surface Preparation Cementitious Substrates: Surface should be cleaned and roughened to create a profile.

Surface Preparation Saw cut around perimeter or repair area to achieve a minimum 1/8 shoulder. This will eliminate feather edging the product and give a clean transition for the repair.

Surface Preparation Steel: Remove all corrosion and contaminants from exposed steel. Surface should be cleaned thoroughly by blast cleaning or mechanical means. Exposed steel should be cleaned to white steel. If half of the diameter is exposed, chip behind bar, ½ minimum for mortar only.

Steel Preparation Steel should be cleaned to a bright metal finish.

Tools Required ½ Drill Motor Low speed drill 400-600 rpm Mortar mixer or Jiffy mixer Margin trowel Steel/Mag Trowel Spatula

Surface Preparation Saw cut around perimeter or repair area to achieve a minimum 3/8 shoulder. This will eliminate feather edging the product and give a clean transition for the repair.

Steel: Surface Preparation 1. Remove all corrosion and contaminants from exposed steel. 2. Surface should be cleaned thoroughly by blast cleaning or mechanical means. 3. Exposed steel should be cleaned to white steel. 4. If half of the diameter is exposed, chip behind bar, ½ minimum for mortar only.

Mixing Equipments I. Mortar Mixer II. Drill and Paddle. Wet down tools and equipments before proceeding to mix. Mixing

Mixing- SikaQuick Mortar 1. Water 4.5-5 Pts/Bag 2. Latex-R- 4.5-5 Pts/Bag. 3. Start with adding liquid to the mixing container. 4. Slowly add powder. 5. Once all the powder is added mix for 3 minutes. 6. Do not add any more than 5 pts of liquid. water.

Mixing- SikaQuick Concrete 1. Water 4.5-5 Pts/Bag 2. Latex-R- 4.5-5 Pts/Bag. 3. Stone - 3/8 gravel 25#/bag. 4. Stone Weigh Before SSD. 5. Start with adding liquid to the mixing container. 6. Slowly add powder. 7. Once all the powder is added and mixed add stone. 8. Mix time 3 minutes after everything is added. 9. Do not add any more than 5 pts of liquid. water.

Aggregate Selection & SSD Consult Technical Data Sheets for detailed recommendations on aggregate selection.

Min / Max application thickness Neat Min 1/4 inch Max 1 inch Extended Min 1 inch Max 6 inches

Scrub/Slurry Coat

Placement

Placement

Finishing

SikaTop Curing Cure as per ACI recommendations. Curing is required. Moist cure with wet burlap and polyethylene, a fine mist of water. Moist curing should commence immediately after finishing. Protect newly applied material from direct sun light, wind, rain and frost.

Curing

SikaQuick 1000 Sika Technical Data Sheets can be obtained via: www.sikaconstruction.com Refer to data sheets for specific information on each Sika product.