MIG Fume Extraction Torch

Similar documents
SVENSKA DANSK NORSK

TIG INVERTER INSTRUCTION MANUAL

15GAL STEEL OIL DRAIN WITH 110V PUMP

INFRARED QUARTZ WALL HEATER

PS ARC Welder Assembly & Operating Instructions

OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER

WEEKLY SAFETY MEETING All Euramax Subsidiaries WELDING SAFETY / HOT WORK SAFETY. Safety Meeting Contents. Meeting Notice.

San josé OWNER S MANUAL

UNI FLAME AUTOLIFT MIG/MMA/TIG. 165/190/220/250 Inverter Manual. 240 Volt. Standard MIG / MAG

Installation Instructions for Alarm Module Kit A043F059

Li Battery Pack & Charger Safety & Operating Instructions

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

120Volt 60-70A ARC WELDER Rev

Pressure Vessels (Air Compressors) and LPG Tanks

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

55-Gallon Dispenser Package

12 Volt 30 Amp Digital Solar Charge Controller

BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.

Threaded Inline Air Heaters

WELDING POSITIONER 00337OG WARNINGS, SAFEGUARDS & OPERATING INSTRUCTIONS

Please read operating instructions carefully before use and keep for further reference.

Forename: Surname: School / College/ Institution. Course date: / / RDTHSC:

PROCEDURES PREVENTION OF ACCIDENTAL IGNITION

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

WSD130 SOLDERING STATION

Oxy-Fuel Gas Welding. Given a functional oxy-fuel gas unit, instruction and demonstration of use, each student will be able to:

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

AWELD160. ARC Welder w/thermal Overload Assembly & Operating Instructions

NITROUS TRANSFER PUMP INSTRUCTIONS

Amps Per Bank. Total Output. Battery System. Model Name. 6 amps 12 amps 10 amps 20 amps 30 amps 40 amps 15 amps 30 amps 45 amps

High Efficiency Vaporizing System and Highly Durable Heaters Ensure 25% Increased Output.

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

Installation and safety instructions for AC/DC built-in devices

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

PERSONAL PROTECTIVE EQUIPMENT HAZARD ASSESSMENT, EQUIPMENT SELECTION AND TRAINING DOCUMENTATION

TBi Industries. MIG / MAG Welding torches TBi Expert 0. 1

Portable Grinder. Given a properly adjusted portable grinder, instruction and demonstration of use, each student will be able to:

Extrusion Flo-Valve INSTRUCTIONS-PARTS LIST psi (210 bar) Maximum Working Pressure. Model , Series K. Rev.

LED Par 56 Ultra Bright RGB Black ORDERCODE Polished ORDERCODE 42451

SBC90. Abrasive Blast Cabinet Assembly & Operating Instructions

PAPER SHREDDER PRS-F-01 USER MANUAL

3 WATT LED SPOTLIGHT Model No. SLM

UV100A Ultraviolet Air Treatment System

12V Portable Diaphragm Compressor Operating and Maintenance Instructions

Job Hazard/Safety Analysis For the Paint & Finish Worker

Please keep these operating instructions in a safe place.

VACUUM CLEANER INSTRUCTION MANUAL

User Guide. Bagless Cylinder White. Get Cleaning... vax.co.uk. Vax Careline: (UK) (ROI) White series

8" BENCH GRINDER OWNER'S MANUAL

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)

Operating instructions in the back. PD1020L

Safety Training Topic PERSONAL PROTECTIVE EQUIPMENT

Hot Water Urns. all models. Helpline. v3.0

OWNER S MANUAL. Model AE150/AE300/AE AMP MULTI-USE SMART BATTERY CHARGER READ ENTIRE MANUAL BEFORE USING THIS PRODUCT

Dear Neuton Owner, This is a helpful hint to guide you in getting the most out of your NEUTON Battery and Charger.

PAINT SPRAY GUN WASHER

TEMPORARY EMPLOYEES SAFETY PROCEDURES

PET-10 INSTRUCTION MANUAL PRESSURE TANK

Emergency Response. Prepared for Fire Service, Law Enforcement, Emergency Medical, and Professional Towing Personnel by American Honda Motor Co., Inc.

BACKPACK SPRAYERS. MODEL NOS: KSP16 & KSP20 Part Nos: & OPERATING & MAINTENANCE INSTRUCTIONS GC04/12

CARING FOR YOUR WATER HEATER

2-SLICE COOL TOUCH TOASTER

CHARGING SYSTEMS INTERNATIONAL

19 LED Tube Controller ORDERCODE 41003

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

Thank You... On behalf of the entire team at Thane Housewares, we appreciate your recent purchase

E&P HYDRAULICS Remote control EPRC-01 Level System Camper

3053 Electrical Safety Training Program Course Outline

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2

Installation Instructions

Single- and Two- Stage Regulators

Robot Welding Torch System

School of Engineering University of Glasgow

Operating Instructions Drill rig DRU160

Installation and Operating Instructions (for chargers shown below)

Achat 115MA full-range speaker. user manual

October Safety Subject

Installation Instructions

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

OPERATING MANUAL ASSEMBLY. Remote control docks magnetically. click. until it clicks and locks. REGISTER YOUR FREE 2 YEAR GUARANTEE TODAY

Compressed Gas Cylinder Storage and Handling Guide

PBX Series Quick Fit Connector Bimetallic Steam Traps

PLASMA CUTTER - 35 AMP

National- Spencer Inc.

Chapter 5 - Aircraft Welding

Compressed Gas Cylinder Safety

tire inflator with pressure gauge

Installation and Operating Instructions (for chargers shown below)

Workshop Self Inspection Checklist WORK01

MODEL T-4 TRENCHER. Operators Manual

aseries A13B Mini Bullet Camera User Manual

SPOT WELDER OPERATING & MAINTENANCE INSTRUCTIONS. Models CSW6T & CSW13T. Part Nos &

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Power supply unit Model: PAC-SC50KUA

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

HOT WORK PERMIT PROCEDURES

LED Par 56 Short DMX ORDERCODE 42421

Instructions For SF 6 Refill Kit

Transcription:

MIG Fume Extraction Torch EXTMT3004 EXTMT5004 Operation instructions Ref 2015-04

Contents 1. The SifGun Fume Extraction Torch 3 2. Safety 4 3. Technical specification 5 4. Unpack and Assemble before use 5 5. Installation and connection 5 6. Use of the equipment 6 7. Troubleshooting 7 8. Maintenance 8 9. Replace and Repair 9 10. De-installation 14 11. Shipment, storage and disposal 15 ExtractabilityTM Peters House, The Orbital Centre Icknield Way, Letchworth Garden City Hertfordshire, SG6 1ET United Kingdom Visit ww.extractability.eu to see our range of fixed and mobile fume extractors, compatible with these torches, T. +44 (0) 845 130 7757 E. sales@weldability-sif.com W. www.sifbronze.co.uk T. +44 (0) 845 862 2620 E. sales@extractability.eu W. www.extractability.eu Copyright 2015, Weldability Sif This documentation is protected by copyright. Any use or modification outside the narrow limits of copyright law without approval of Weldability Sif is inadmissible and punishable. This applies in particular to duplication, translations, micro-filming, and the storage and processing in electronic systems. 2

1. The SifGun Fume Extraction Torch The SifGun Fume Extraction Torch is a patented MIG welding torch with integrated extraction at the nozzle of the welding torch. Therefore the extraction is close to the weld pool, so the fumes coming from the welding process are extracted immediately. As a result the welder is exposed to up to 95% less welding fumes. Because of the conic shape of the nozzle, the protective gas exits at a high speed and is not sucked away by the extraction. The quality of the welding process remains the same as with a welding torch without integrated extraction. The welding torch is delivered ready to use. It only has to be connected to a welding machine and extraction unit. The SifGun Fume Extraction Torch is available in a air- and water-cooled version The welding torches in this manual have been build in compliance with: EN 60974-7 Arc Welding Equipment Part 7: Torches 2006/95/EC Low Voltage Directive 2004/108/EC Electromagnetic Compatibility The welding torch is only to be used by experienced personnel. It is not allowed for untrained persons to install, handle or maintain our welding torches. Welding torches must be checked regularly in order to guaranty optimum life time expectancy. The user is fully responsible for possible defects arising out of misuse, inadequate maintenance, damage, poor repair, or modifications by other parties than the original manufacturer, or his authorised dealers. The welding torch is a component of a complete welding system. The torch will generate an electric arc when connected with the appropriate welding machine. Ensure that you read the welding machine s instructions thoroughly before using our welding torches. The manufacturer reserves the right, whenever necessary and without prior notice, to amend these instructions as a result of clerical or printing errors, incorrect information, or the addition of improvements. 3

2. Safety WARNING READ THESE SAFETY INSTRUCTIONS CAREFULLY. Failure to observe these safety instructions can lead to serious injury and/or damage to the product. Only operators with relevant knowledge of arc welding should use this product. The vibration of the welding torch is less than 2.5m/s². No special precautions are required related to vibrations. Arc welding can injure eyes, burn skin and cause hearing damage. Therefore: - Use welding shield with filter complying with respectively the EN 175 and EN 379 standards. - Wear proper protective clothing and ear protection. - Make sure others are protected (e.g. curtains) from arc rays and flashing. Remove all combustible materials including liquid and gaseous fuels, cloth, sawdust, wood, paints and solvents - from the work area or completely cover the materials with a protective non-flammable covering. Fire extinguishing equipment should be ready at hand for instant use. Pay attention to spatter/dross created during welding; sparks can cause fire several hours after welding has finished Work pieces must be completely cleaned so that no substances on the material, such as chlorinated solvents, can produce flammable or toxic vapours. Do not weld containers that have held combustibles. Always check cables before operating the machine. Defective cables may cause injury and/or fire. Do not make temporary repairs. Repairs should be made by qualified personnel. Do not pull cable assembly across sharp edges or expose to welding spatter or hot surface. To prevent electric shock, isolate yourself by using proper protective clothing and insulating mats. DO NOT wear wet clothing Do not exceed power rating. Overload can lead to torch damage, destruction and/or injuries. Turn off primary power before working on torch parts and/or replacing consumables. Do not breathe fumes or gases from welding. Welding fumes are harmful; lead, cadmium, copper, zinc, mercury, stainless steel, galvanised steel and beryllium in particular. Therefore, use ventilation or an extraction system to ensure that Maximum Admissible Concentration of harmful substances (MAC) level is not exceeded. Use proper gas for the welding process (argon or helium) and pressure reducing regulator. Keep cylinders in an upright position. When not in use, keep cylinder valves closed. Keep cylinders awa y from heat, sparks or flame. Follow the pressurised gas manufacturer s operating instructions for mounting the regulator to the gas cylinder. 4

3. Technical specification Power rating - Mixed gas - CO2 SifGun Extraction Torch air cooled 300A 320A SifGun Extraction Torch water cooled 500A 550A Duty cycle 100% 100% Contact tip Ø1.0-1.6mm Ø1.0-1.6mm Extraction flow rate between 55 and 65m³/h between 55 and 65m³/h Gas flow rate 14l/min 14l/min 4. Unpack and Assemble before use The delivered welding torch is ready to use with a contact tip of 1.2mm. The welding torch package should contain: Welding torch assembly. Gas flow meter Nozzle cleaning brush To use a contact tip with other diameter, see Overview of the user replaceable parts 5. Installation and connection Air cooled torch B A Water cooled torch 1 2 B A A B 1 2 3 5

50 45 40 35 30 25 20 15 10 5 CeraMIGuard www.sifbronze.co.uk www.sifbronze.co.uk 1. Plug in (A) the welding connection and fasten (B). 2. Plug in the extraction. 3. In case of a water cooled torch, plug in the cooling connections A (red) and B (blue). 6. Use of the equipment 14 l/min 65 m 3 /h 55 m 3 /h 2 4 Start-up 1. Switch on the extraction unit. 2. Extraction flow rate must be between 55 and 65m³/h at nozzle 3. Switch on the welding machine 4. Check the protective gas flow with the special gas flow meter delivered with the torch. Gas flow rate must be 14l/min at nozzle. Use The torch can be used like any other MIG welding torch. The functionality depends on the settings of the welding machine. Important Don t use Anti Spatspray or Paste, only Sif CeraMIGuard. Shutdown 1. Switch off the welding machine 2. Switch off the extraction unit, only if not used for other equipment. 6

7. Troubleshooting Symptom Possible causes No arc Power to work piece or swan neck interrupted. Defect power source or control unit. Control signal is interrupted (cable). Switch protection in the power source is not activated. Arcing to the work piece Nozzle is contaminated. Poor or no smoke extraction Extraction unit is not switched on. Extraction flow is less than 55m3/h. Filter of the extraction unit is contaminated. Torch is externally damaged. Swan neck overheats Insufficient cooling water flow. Cooling water lines are blocked. Duty cycle exceeds the value allowed for the torch. Contact tip or tip adapter not properly fastened. Torch is externally damaged. Welding wire fuses with the contact tip Welding wire transport starts to late. Welding wire is jammed inside the cable package due to contamination or bending. Welding wire speed is too low. Distance between the contact tip and the work piece is too big. Contact tip overheats. Contact tip overheats Insufficient cooling water flow. Cooling water lines are blocked. Duty cycle exceeds the value allowed for the torch. Contact tip or tip adapter not properly fastened. Torch is externally damaged. Irregular welding wire feed Pressure of the welding wire supply rolls is too low. Defect in the welding wire feed hose. Wrong liner is installed. Defect control unit. Excessive wear of the welding wire supply rolls. Wrong welding wire supply rolls installed. Porosity Nozzle opening or contact tip is contaminated. Insufficient gas shielding (gas flow). Air flow disturbs the gas shielding. Liner nut not tightened correctly. Wrong liner is installed. 7

8. Maintenance WARNING ALWAYS SWITCH OFF THE WELDING MACHINE AND EXTRACTION UNIT BEFORE YOU REMOVE PARTS OF THE TORCH. Daily Regularly check if the protective gas and extraction openings are clean. If necessary remove the nozzle and clean the opening with the brush. Weekly Clean liner 1. Disconnect the torch assembly from the welding machine. 2. Remove the nozzle (A) and contact tip (B) from the torch. A B 3. When necessary, remove welding wire from the assembly. 4. Use a compressed air cleaning gun to clean inside liner. 8

9. Replace and Repair CAUTION All parts replacements and repairs that are not mentioned in this document must be done by a contracted distributor or Weldability Sif Overview of the user replaceable parts CAUTION Never replace parts of thesifgun Fume Extraction Torch with standard MIG parts. The parts of the torch are different. Item Description Partnumber Contact tip M8-1,0 Contact tip M8-1,0 Alu Contact tip M8-1,0 CuCrZr Contact tip M8-1,2 Contact tip M8-1,2 Alu Contact tip M8-1,2 CuCrZr Contact tip M8-1,6 Contact tip M8-1,6 Alu Contact tip M8-1,6 CuCrZr EXTMT140110 EXTMT1401102 EXTM1401101 EXTMT140112 EXTMT1401122 EXTMT1401121 EXTMT140116 EXTMT1401162 EXTMT1401161 Tip adapter M8 EXTMT153458 Nozzle conical EXTMT2407145 Center ring EXTMT3407145305 Red coated liner 4mtr (for 1,0-1,2mm wire) Red coated liner 5mtr (for 1,0-1,2mm wire) Yellow coated liner 4mtr (for 1,6mm wire) Yellow coated liner 5mtr (for 1,6mm wire) EXTMT302545 EXTMT302555 EXTMT303645 EXTMT303655 9

Replace Nozzle WARNING ALWAYS SWITCH OFF THE WELDING MACHINE AND EXTRACTION UNIT BEFORE YOU REMOVE PARTS OF THE TORCH. 1 2 Replace Contact Tip WARNING ALWAYS SWITCH OFF THE WELDING MACHINE AND EXTRACTION UNIT BEFORE YOU REMOVE PARTS OF THE TORCH. 1 2 3 4 10

Replace Tip Adapter WARNING ALWAYS SWITCH OFF THE WELDING MACHINE AND EXTRACTION UNIT BEFORE YOU REMOVE PARTS OF THE TORCH. 1 2 3 4 5 6 11

Replace Center Ring WARNING ALWAYS SWITCH OFF THE WELDING MACHINE AND EXTRACTION UNIT BEFORE YOU REMOVE PARTS OF THE TORCH. 1 2 3 4 5 6 7 8 12

Replace Liner WARNING ALWAYS SWITCH OFF THE WELDING MACHINE AND EXTRACTION UNIT BEFORE YOU REMOVE PARTS OF THE TORCH. 1 2 3 4 5 6 7 8 9 10 11 12 13 13

10. De-installation WARNING ALWAYS SWITCH OFF THE WELDING MACHINE AND EXTRACTION UNIT BEFORE YOU REMOVE PARTS OF THE TORCH. Air cooled torch B A 1 3 Water cooled torch B 1 2 3 1. Disconnect the extraction. 2. Disconnect the cooling connections A (red) and B (blue). 3. Loosen the welding connection (B) and disconnect (A). A B A 14

11. Shipment, storage and disposal This welding equipment has been carefully checked and packaged before shipment. However, as damage may have occurred during shipping, please check package and components for damage through visual inspection. If package and/or equipment has been damaged contact last shipping agent immediately and keep (damaged) package for possible inspection. Use original package for returning equipment. The ambient temperature for shipment and storage is: -25 ºC to + 55 ºC Relative humidity of the air: up to 90% at a temperature of 20 ºC Torch must be disposed according to European and/or local environmental regulations. Our torches are mainly made of steel, plastics and non-ferrous metal. 15

16