1. Furnishing and installing new fencing and initial mock-up section of fence.

Similar documents
PTS HELICAL PIERS INSTALLATION SPECIFICATIONS NOTICE

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 11/5/13)

RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS

COMMONLY USED RESIDENTIAL BUILDING CODES

Chapter 3 Pre-Installation, Foundations and Piers

SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)

SECTION STORM DRAINAGE SYSTEM

The minimum reinforcement for the stem wall is the placement of:

CONCRETE FLOOR SLAB & CASTING BED CONSTRUCTION

DENVER MODEL 30 X 30 SPECIFICATIONS

SECTION 1 GENERAL REQUIREMENTS

SECTION PRECAST CONCRETE STRUCTURES

STANDARD SPECIFICATIONS SECTION PRECAST REINFORCED CONCRETE MANHOLES AND MANHOLE BASES. 1. Structure Earthwork: 02200

CCU Engineering Specifications. Section PRECAST CONCRETE PRODUCTS

NAPCA BULLETIN APPLICATION PROCEDURES FOR CONCRETE WEIGHT COATING APPLIED BY THE COMPRESSION METHOD TO STEEL PIPE

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

Wastewater Capital Projects Management Standard Construction Specification

TORO STEEL BUILDINGS. BOLTS: o " diam. x " diam. x " diam. C.J. - Control Joints to minimize cracking.(0.

SECTION UNDERGROUND ELECTRIC SERVICE

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

SECTION EARTH MOVING

SPECIFICATION Section Insulated Precast Concrete Wall Panels

Specification Guidelines: Allan Block Modular Retaining Wall Systems

CHAIN-LINK FENCES BID SPECIFICATIONS DESCRIPTION

SECTION PRECAST CONCRETE UTILITY STRUCTURES

SPECIFICATIONS. INTERLOCKING CONCRETE POROUS PAVING UNITS or Permeable Interlocking Concrete Pavers (PICP)

SECTION STORM DRAINAGE STRUCTURES. 1. Trench excavation, backfill, and compaction; Section

Residential Deck Safety, Construction, and Repair

SECTION PUBLIC STORM UTILITY DRAINAGE PIPING

Report on. Wind Resistance of Signs supported by. Glass Fiber Reinforced Concrete (GFRC) Pillars

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

SECTION STORM DRAIN SYSTEM

ATLANTA MODEL SPECIFICATIONS

COLORADO MODEL. 35 x 65 SPECIFICATIONS

C. Section TESTING LABORATORY SERVICE.

LAYING BLOCK AND BRICK

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

Diameter. Swift Lift Round Recess Plug. Note: The diameter of the narrow recess plug is the same as the diameter of the round recess plug.

Chapter. Restoration of Damaged Structures

Free-Form Concrete Pool

Laying the First Course. 1. Excavate the site and construct the footing.

PROJECT TITLE : 2-STOREY RESIDENCE LOCATION : ALONG DAANG HARI,MOLINO.BACOOR,CAVITE OWNER : CUEVASVILLE REALTY

Safe & Sound Bridge Terminology

SECTION REMOVAL OR ABANDONMENT OF EXISTING UTILITIES AND UNDERGROUND STRUCTURES. 1. Trench excavation, backfill, and compaction; Section

TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE

Installation PowerPoint for Grasscrete Formers

SECTION PRECAST CONCRETE STRUCTURES

SECTION 36 - CAST-IN-PLACE CONCRETE PIPE (CIPCP) TABLE OF CONTENTS

ASPHALT & CONCRETE SPECIFICATIONS

AIRPORT SECURITY FENCING. A. American Society for Testing and Materials (ASTM):

SECTION STORM DRAINAGE TABLE OF CONTENTS

MeltonStone Cast Stone Product Specifications

SIENA STONE GRAVITY RETAINING WALL INSTALLATION SPECIFICATIONS. Prepared by Risi Stone Systems Used by permission.

Foundations 65 5 FOUNDATIONS. by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. Seismic Retrofit Training

Section 2100-Trenching and Tunneling

Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin

SECTION LS 2530 SANITARY SEWERS. A. General: Submit the following in accordance with The General Conditions.

High Strain Dynamic Load Testing of Drilled Shafts

LOWELL REGIONAL WASTEWATER UTILITY SPECIFICATIONS FOR THE LOWELL MA CONCRETE FLOODWALL REPAIRS

SECTION CHAIN LINK FENCES AND GATES

NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS

ARDEX GUIDE SPECIFICATION ARDEX Exterior Concrete Repair & Resurfacing Polymer-Modified, Cement-Based, Patch & Horizontal Overlay Materials

FORM DESIGN. easy to work with, and generally available.

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

6 RETROFITTING POST & PIER HOUSES

DIVISION 2 - SEWERAGE AND DRAINAGE SECTION STORM DRAIN SYSTEMS PART 1 - GENERAL

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

Dubai Municipality Standard DMS 1: Part 5: 2004

The work of this Section includes furnishing and installing Reinforced Concrete Pressure Pipe as shown on the Drawings and as specified.

FY08 SEWER POINT REPAIRS BID TABULATION

STRUCTURES Excavation and backfill for structures should conform to the topic EXCAVATION AND BACKFILL.

PC-Concrete Injectable Concrete Anchoring and Repair System

Detailing of Reinforcment in Concrete Structures

INSTRUCTIONS FOR COORDINATION SECTION SOLID SURFACE FABRICATIONS

Tremie Concrete CM 420 CM 420 CM 420 CM 420. Temporary Structures. Tremie Concrete

Guide Specification Precast Concrete Products

Window Installation Instructions

Lighthouse Engineering, L.L.C.

Built to Last. Built for Beauty. Good. Solid. Logix. TM

SECTION CAST-IN-PLACE CONCRETE

How To Retaining Wall Guide

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

Storm Drain Inlet Protection - IP

TECHNICAL SPECIFICATIONS CEMENT-BENTONITE SLURRY TRENCH CUTOFF WALL

EXCAVATION AND PILING NEAR SEWERS, STORMWATER DRAINS AND WATER MAINS

Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing

Hunter College school of Social Work Thesis Proposal

STANDARD SPECIFICATIONS FOR PRIVATE BUILDING SEWER LINES IN PUBLIC RIGHT-OF-WAY

SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS

EAST LYME HIGH SCHOOL

Micropiles Reduce Costs and Schedule for Merchant RR Bridge Rehabilitation

DIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council. *Corrected March 2014

Residential Foundations and Basements

Mobile Home Pre-Inspection Checklist

SWIMMING POOL, SPA, & HOT TUB GUIDELINES

Division 4 Section Concrete Masonry Specifications

PART 1 GENERAL 1.1 SECTION INCLUDES

Transcription:

VERTI-CRETE SPECIFICATIONS FOR PRECAST WALL SYSTEM SECTION 03 45 13 PRECAST ARCHITECTURAL CONCRETE PART I: GENERAL 1.01 SUMMARY A. This Section specifies requirements for precast concrete screening walls, perimeter fencings and noise walls and installation instructions as required for complete, high quality and long lasting walls and including the following. 1.02 QUALITY ASSURANCE 1. Furnishing and installing new fencing and initial mock-up section of fence. A. INSTALLER QUALIFICATIONS: Engage an experienced Installer who has experience with architectural precast concrete screening wall or noise barrier projects with similar material and of similar scope to that indicated for this Project with a successful construction record of in-service performance. Installer must submit names, location, and phone number of three references as well as description of the project successfully completed for each reference. 1. Installer shall be registered and/or licensed and approved by authorities having jurisdiction. B. SINGLE SOURCE RESPONSIBILITY: 1. Obtain concrete fence materials manufactured in the United States from a single source duly licensed or authorized to manufacture or distribution Verti- Crete TM precast wall panels, columns and caps. C. MANUFACTURER QUALIFICATION: Engage a firm experienced in producing precast concrete screening wall or noise barrier units in accordance with those indicated for the Project and with a record of successful in-service performance, as well as sufficient production capacity to produce required units without delaying the Work. 1.03 SUBMITTALS 1. Manufacturer must be licensed by Verti-Crete, LLC as a Producer of Verti- Crete TM precast wall panels, columns and caps. 2. Manufacturer shall be registered and approved by authorities having jurisdiction. GENERAL: Submit the following according to the Conditions of the Project and Division Specification Sections. 03 45 13-1

1. Product Data: Furnish manufacturer s literature for each architectural precast concrete screening wall or noise barrier. 2. Color Chart: Show full range of available base and accent colors 3. Shop Drawings: Provide working drawings indicating all information necessary for precasting screening wall or noise barrier elements. Drawings shall illustrate the shape and dimension of precast components; the size, quantity and details of the reinforcing steel; the quantity, type, size and details of connection and lifting hardware. Drawings shall bear the seal of a New York State registered professional engineer. PART II: PRODUCTS 2.01 MANUFACTURERS [Insert Closest Producers] [See list on http://www.verti-crete.com/find-a-producer.jsp] 2.02 MATERIALS A. WALL SYSTEM (PANELS AND COLUMNS) 1. 6 high 2. Panels shall have a molded stone or masonry pattern on both sides. 3. Columns shall have a molded stone pattern on all four sides except where the notch appears to receive the connecting panel. 4. Panels shall be monolithic. 5. Columns shall be monolithic. 6. Columns shall have a concrete cap 7. Panels, columns and caps shall be constructed from normal weight concrete having sand and gravel or crushed stone aggregates mixed with ASTM-C150, Type 1 or Type III Portland Cement and shall have a minimum compression strength of 4,000 psi @ 28 days. 8. Color: Concrete shall be colored after installation with a 100% acrylic/polysiloxane structural concrete stain. 9. Column footings: 13 2 on-center (maximum); depth and width and steel reinforcing as per approved engineer s drawings in accordance with local building code requirements. Footings may be closer and panels cut to accommodate changes in direction to fit property lines and/or project requirements. 10. Panel Reinforcing: Minimum perimeter rectangle of #4 steel rebar 6 from all four edges of each panel. Additional reinforcing (if required) as per approved engineer s drawings in accordance with local building code requirements. 11. Column Reinforcing: Minimum of 4, #4 verticals with #3 horizontal rings at 12 centers as per approved engineer s drawings. Additional reinforcing (if required) as per approved engineer s drawings in accordance with local building code requirements. 03 45 13-2

12. Footing/Column Connection: two 6 long #4 (minimum) imbedded in the center of each footings. 3 should be imbedded into footing leaving 3 exposed to then protrude through the center of each column (each column shall be cast with a hollow center) 13. Loading: Wind loading and surcharge loads, will be applied to the panels, columns and foundations components per local building code requirements. B. Component Dimensions 1. Columns shall have a typical width of 20 x 20 square with 3 minimum depth notch to receive the tapered ends of each panel. Each column shall have a tapered hollow center, 8 x 8 at the top down to 6 x 6 at the bottom. 2. Panels shall have a typical dimension of 12 long by 8 tall by 4 thick (4 minimum thickness, 7 maximum thickness at the false cap) 3. Caps shall have a typical dimension of 22 x 22 4. Columns shall be installed on top of pier footings previously poured in place as per engineer s drawings. Column shall be secured by a rebar anchor embedded into the footing that protrudes through the through the hollow center of the column. After a section of fence is installed each column shall be filled with concrete to a minimum level 6 above the height of the rebar anchor. 5. Panel/Column connection shall be tongue and groove construction. 6. Panel Reinforcing: Minimum perimeter rectangle of #4 steel rebar 6 from all four edges of each panel. Additional reinforcing (if required) as per approved engineer s drawings in accordance with local building code requirements. 7. Column Reinforcing: Minimum of 4, #4 verticals with #3 horizontal rings at 12 centers as per approved engineer s drawings. Additional reinforcing (if required) as per approved engineer s drawings in accordance with local building code requirements. C. Color 1. Fence shall be colored after installation where possible with a 100% acrylic/polysiloxane concrete stain. (i.e. Kwal Paint Stone-FX Acrylic/Polysiloxane Stain #727) 2. When coloring the fence after installation is not possible (i.e. because of weather, interference with traffic, accessibility or concern from overspray onto adjacent structures or property), the concrete elements may be pre-stained by coloring them in the manufacturer s facility. The fence should then be touched up after installation to ensure a consistent, natural looking and complete finish. 3. Base color should be applied with an airless sprayer; accent colors should be applied with sponges 4. Colors selected from manufacturer s color chart. D. Column Footings 1. 13 2 on center (maximum) 2. Diameter: 24 typical 3. Depth: 3 minimum or as per approved engineer s drawings in accordance with local building code requirements. 4. Reinforcing: 4-#4 vertical bars with #3 ties on 12 centers or as per approved engineer s drawings in accordance with local building code requirements. 03 45 13-3

5. Concrete shall be normal weight concrete having sand and gravel or crushed stone aggregates mixed with ASTM-C150, Type 1 or Type III Portland Cement and shall have a minimum compression strength of 3,000 psi @ 28 days. E. Mow Strip (not required structurally) 1. Continues with fence line 2. Width: 20 (typical) to match the width of the columns 3. Depth: 4 (typical) 4. Concrete shall be normal weight concrete having sand and gravel or crushed stone aggregates mixed with ASTM-C150, Type 1 or Type III Portland Cement and shall have a minimum compression strength of 3,000 psi @ 28 days. 2.03 General A. Load Criteria: Based on the following Minimum Soil Properties and Local Codes 2.04 Concrete 1. Soil Type: Sandy Silty Clay 2. Soil Compaction: 95% Standard Proctor 3. Minimum soil lateral bearing allowable: 150 PSF/FT of depth below grade 4. Minimum soil bearing pressure allowable : 2000 PSF 5. Design wind speed 90-120 MPH (depending on local building requirements) A. Concrete Material 1. Concrete shall be normal weight concrete having sand and gravel or crushed stone aggregates mixed with ASTM-C150, Type 1 or Type III Portland Cement and shall have a minimum compression strength as follows: a. Panels/Columns/Caps: 4,000 psi @ 28 days b. Footings: 3,000 psi @ 28 days c. Column Centers 3,000 psi @ 28 days 2. Water used for concrete shall be clean water and free from injurious amounts of oils, alkalis, organic or other deleterious substances. 3. All concrete for panels, columns or footings shall contain an air-entraining admixture resulting in 5% (+/ - 1%) entrained air or as per local building code requirements. B. Reinforcing Materials: 1. All reinforcing steel shall be deformed type bars or welded wire mesh. All deformed type bars shall conform to ASTM A615, Grade 60, placed as show on approved drawings. All welded wire mesh shall conform to ASTM A185, Grade 60, placed as shown on approved drawings (if required). 03 45 13-4

2. All ties and stirrups shall conform to the requirements of ASTM A615, Grade 60. PART III: EXECUTION Installation A. General: Installation shall be as per manufacturer s recommendations. 1. Utility Lines. Contact local Utility Locator to have all underground power lines marked BEFORE installation begins. 2. Grade. The ground should be prepared to a grade 4 below the final grade. This allows for a 3 tall footing form to square off top of footing and then 1 of backfill to cover bottom of wall for final grade or mow strip. 3. Soil. Excavation for footings to undisturbed soil should be minimum 2 in diameter by a depth of 3 for 6 high wall and 4 for 8 high wall or as per local building code requirements. Leave bottom-bearing surface clean and smooth. If footing excavations are made deeper than intended, only concrete shall be used for fill. 4. Reinforcing. Reinforcing steel for footings should be installed as per engineer s drawings with the minimum clearance of 3 from all sides 5. Form Footings. The top of each footing should be formed to a square and level surface 2 x 2 with the square pad having a minimum thickness of 3. 6. Footing Elevations. Wall panels will span from footing to footing and should rest on two level points. When the relative heights of the top of two adjacent footings differ, the downhill side of the uphill footing should be notched out to allow the panel to rest on two level surfaces. This notch may be formed as part of the footing form or may be created by removing a portion of the concrete footing with a square nose shovel while the concrete is still green. Alternately, the bottom corner of the panel may be cut to allow the panel to rest level. Notch should be no more than 8 long by 8 wide by 12 deep. 7. Rebar Anchors. Footings should have rebar anchors cast into each center as per engineer s drawings. 8. Level. Panels and Columns should be plumb and level. Plastic or other nonorganic shims may be used where necessary to ensure that each panel and post is square and level. 9. Fill Posts. Columns should be filled with concrete to a minimum height 6 above the top of the rebar anchor. If a gate or any other structure will be mounted to a column, the column should be filled to the top. Columns should not be left unattended or without bracing until filled with concrete (with or without panels installed). 10. Set Caps. Caps should be set on top of each column after column is filled with concrete. Cap may be set with masonry adhesive or a standard masonry grout. 03 45 13-5

If masonry adhesive is used the seam should be calked between the column and the cap to ensure a solid cosmetic seal. 11. Stain. Wall should be colored with a 100% acrylic/polysiloxane concrete stain. (i.e. Kwal Paint Stone-FX TM Acrylic/Polysiloxane Stain #727) Base color should be applied in two coats using an airless spray gun. Accent colors may be applied after base color dries using a sponge, brush or roller. Before staining, concrete surface should be clean and free from any dirt or debris. END OF SECTION 03 45 13-6