Bone Growth Stimulation Metatarsal Case Series. 30 minute solution

Similar documents
PROVEN NON-INVASIVE TREATMENT FOR RHEUMATOID ARTHRITIS

Pain Management. Practical Applications in Electrotherapy

NeuroStar TMS Therapy Patient Guide for Treating Depression

.org. Lisfranc (Midfoot) Injury. Anatomy. Description

Fracture Care Coding September 28, 2011

The Total Ankle Replacement

Hip and Knee Outcomes Questionnaire

Bone Growth Stimulators

Sports Related Fractures of the Foot and Ankle

Corporate Medical Policy Electrical Bone Growth Stimulation

Foot and Ankle Technique Guide Proximal Inter-Phalangeal (PIP) Fusion

Calcaneus (Heel Bone) Fractures

chronos BOne VOid Filler Beta-Tricalcium Phosphate (b-tcp) bone graft substitute

Adult Forearm Fractures

Treatment of Recalcitrant Intermetatarsal Neuroma With 4% Sclerosing Alcohol Injection: A Pilot Study

.org. Ankle Fractures (Broken Ankle) Anatomy

frequently asked questions Knee and Hip Joint Replacement Technology

.org. Posterior Tibial Tendon Dysfunction. Anatomy. Cause. Symptoms

Lentur Cable System. Surgical Technique

FACTS about. MENTOR MemoryGel. Silicone Gel Filled Breast Implants

Toe fractures are one of the most

AAOS Guideline of The Diagnosis and Treatment of Osteochondritis Dissecans

MEDICAL CENTRES AND SCANS

.org. Knee Arthroscopy. Description. Preparing for Surgery. Surgery

ICD 10 CM IMPLEMENTATION DATE OCT 1, 2015

INFUSE Bone Graft. Patient Information Brochure

Ruby O Brochta-Woodward BSN, CPC, CCS-P, COSC, ACS-OR April 17, 2013 AAPC National Conference Orlando, FL


Degenerative Spine Solutions

.org. Plantar Fasciitis and Bone Spurs. Anatomy. Cause

Spine University s Guide to Transient Osteoporosis

Achilles Tendon Repair, Operative Technique

Dental Bone Grafting Options. A review of bone grafting options for patients needing more bone to place dental implants

Joseph Johnson MD Bldg. 2 Suite Old West Broad Street Athens, GA Office: Fax: Jtjohnson63@gmail.

Scaphoid Fracture of the Wrist

We compared the long-term outcome in 61

Standard of Care: Tibial Plateau Fracture

Commonly Missed Fractures in the Emergency Department

FUSEFORCE. Hand Fixation System SURGIC A L T ECHNIQUE

X-ray (Radiography) - Bone

Biomet SpinalPak Non-Invasive Spine Fusion Stimulator System

Chpter 2 Nonoperative Management of Non-displaced Acute Scaphoid Fracture

Legg-Calve'-Perthes Disease The National Osteonecrosis Foundation

Competency Based Goals and Objectives:

Position Statement: The Use of Total Ankle Replacement for the Treatment of Arthritic Conditions of the Ankle

Corporate Medical Policy

Magnetic Resonance Imaging

4052 Slimplicity Tech final_layout 1 6/29/15 3:29 PM Page 2 Surgical Technique

UNILATERAL VS. BILATERAL FIRST RAY SURGERY: A PROSPECTIVE STUDY OF 186 CONSECUTIVE CASES COMPLICATIONS, PATIENT SATISFACTION, AND COST TO SOCIETY

.org. Osteochondroma. Solitary Osteochondroma

Osteoporosis/Bone Health in Adults as a National Public Health Priority

Orthopaedic Issues in Adults with CP: If I Knew Then, What I Know Now

Ankle Fractures - OrthoInfo - AAOS. Copyright 2007 American Academy of Orthopaedic Surgeons. Ankle Fractures

Curriculum Vitae Curtis R. Noel, MD

Osteoarthritis progresses slowly and the pain and stiffness it causes worsens over time.

.org. Arthritis of the Hand. Description

DIAGNOSING SCAPHOID FRACTURES. Anthony Hewitt

RENOWN REGIONAL MEDICAL CENTER DEPARTMENT OF ORTHOPAEDICS DELINEATION OF PRIVILEGES

Metal-on-Metal Hip Systems

ANTERIOR LUMBAR INTERBODY FUSION (ALIF) Basic Anatomical Landmarks: Anterior Lumbar Spine

Transmittal 55 Date: MAY 5, SUBJECT: Changes Conforming to CR3648 for Therapy Services

George E. Quill, Jr., M.D. Louisville Orthopaedic Clinic Louisville, KY

FEMORAL NECK FRACTURE FOLLOWING TOTAL KNEE REPLACEMENT

Sientra Silicone Gel Breast Implants Quick Facts About Breast Augmentation And Reconstruction

.org. Shoulder Pain and Common Shoulder Problems. Anatomy. Cause

.org. Metastatic Bone Disease. Description

PRESENTATIONS/PAPERS INTERNATIONAL. RAISING STANDARDS IN JOINT ARTHROPLASTY Course Co-Chairman, The Great Debate - London, June 2013

Orthopedic Foot Instruments. Dedicated instruments for reconstructive foot surgery.

Integra. Subtalar MBA Implant

Mary LaBarre, PT, DPT,ATRIC

Mitchell S. Fourman M.Phil Eugene Borst BS Eric Bogner, MD S. Robert Rozbruch MD Austin T. Fragomen, MD

.org. Herniated Disk in the Lower Back. Anatomy. Description

Wrist and Hand. Patient Information Guide to Bone Fracture, Bone Reconstruction and Bone Fusion: Fractures of the Wrist and Hand: Carpal bones

Technology Breakthrough in Spinal Implants (Technical Insights)

Y O U R S U R G E O N S. choice of. implants F O R Y O U R S U R G E R Y

The Ankle Sprain That Won t Get Better. By: George E. Quill, Jr., M.D. With springtime in Louisville upon us, the primary care physician and the

world-class orthopedic care right in your own backyard.

No two knees are alike. That s why we personalize your surgery just for you. Zimmer Patient Specific Instruments. For Knee Replacement Surgery

DOCKET NO M5 MDR Tracking No. M TEXAS IMAGING AND DIAGNOSTIC BEFORE THE STATE OFFICE CENTER PETITIONER

User Manual Table of Contents. Instructions for Using the LaserTouchOne Charging the Unit... 5 Holding the Device... 5 Treatment Steps...

CMS Referral for Own Motion Review by DAB/MAC and 2 others Beneficiary (if not the Appellant) List attached ALJ Decision Date

High-Flex Solutions for the MIS Era. Zimmer Unicompartmental High Flex Knee System

Information for Our Patients Regarding Metal-on-Metal (MoM) Hip Replacements

National Medical Policy

Spinal Cord Stimulation (SCS) Therapy: Fact Sheet

TRANSITIONING FROM ICD-9 TO ICD-10 CODES PRESENTED OCTOBER 8, 2015 NATALIE RIVERA, RN, MS, BSN, CCM, CNLCP

WE ARE YOUR FOOT AND ANKLE CARE EXPERTS. EXPERIENCE. INNOVATION. COMPASSION. REFERRING PHYSICIAN INFORMATION

EMPLOYMENT: PEACHTREE ORTHOPAEDIC CLINIC ATLANTA- GA PRESENT Orthopaedic Surgeon Northside Hospital, Atlanta, GA

TABLE OF CONTENTS. Surgical Technique 2. Indications 4. Product Information Patient Positioning and Approach 2

Back & Neck Pain Survival Guide

ASSOCIATE PROFESSOR BO POVLSEN Emeritus Consultant Orthopaedic Surgeon Guy s & St Thomas Hospitals NHS Trust GMC no

Update to the Treatment of Degenerative Cervical Disc Disease

Posterior Referencing. Surgical Technique

Proximal Hip Fracture Open Reduction/Internal Fixation and Rehabilitation

Rebuilding your INDEPENDENCE. The Joint Center. This is your hospital.

Spinal Cord Injury. North American Spine Society Public Education Series

Total Hip Joint Replacement. A Patient s Guide

International Postprofessional Doctoral of Physical Therapy (DPT) in Musculoskeletal Management Program (non US/Canada) Curriculum

August 21, TCM Associates Ltd Mr. Iain Alligan Technical Director 3 Hillgrove Business Park Nazeing Road Essex EN9 2HB United Kingdom

(Intro to Arthritis with a. Arthritis) Manager of Education & Services for the Vancouver Island Region of The Arthritis Society

Transcription:

Bone Growth Stimulation Metatarsal Case Series 30 minute solution

ECONOMIC IMPACT POTENTIAL The Advantages are Clear 76,500 is: PATIENTS F CM clinically supported (in level 1 PMA trial)7 76,500 scientifically shown to promote growth factors6 metatarsal nonunion fractures* financially cost effective in treating nonunion fractures10 metatarsal nonunion fractures* 765,000 15.3 million metatarsal fractures EBGS when electronic bone growth stimulation is applied 9 fractures 1,2 Cost to the health care system in treating nonunion fractures: NO STIM no bone growth stimulation utilized LIPUS when ultrasound bone growth stimulation applied $20k $21k financial breakdown *indicates estimated annually U.S. data only. $22k $23k $24k $25k Recent published health economic data confirms electrical bone growth stimulation is the most cost effective treatment (21,632) vs. no stim (23,843) vs. LIPUS (23,964) to the health care system in treating nonunion fractures.10

FOOT & ANKLE HIGHLIGHTS The only post-market registry data FDA reviewed with a high heal rate of 86% for nonunion metatarsal fractures in 81 days 8. 30min need 0need Effective in just one 30 minute treatment to best mimic cell replication Zero need to cut a hole in cast for treatment - + Promotes bone formation by short exposure and continuous operation within low frequencies optimal to heal bone 3,4 Potent signal targets the production of IGF-II, one of the most abundant growth factors in bone 5,6 Built in monitor promotes improved patient compliance Targeted treatment field, signal strength does not diminish as it passes through tissue Simple one button operation, no gels or electrode placement required

CLINICAL PRESENTATION Initial x-ray 3 months later 26 year old female 7-day history right lateral foot pain Non-displaced base of the 5th metatarsal fracture identified Treated conservatively with short CAM walker No clinical progression toward healing, nonunion diagnosis Persistent fracture gap of 2mm Initiated CMF bone growth stimulator treatment for 30 min once daily

CLINICAL OUTCOME 6 months - post diagnosis CMF offers multiple sizes to accommodate your foot and ankle fracture sites. Clinical Outcome Healed Fracture 6 months post diagnosis Well-united fracture site noted 92 days utilizing the CMF bone growth stimulator Patient asymptomatic Case Study Provided by Dr. Carroll Kratzer Raleigh Orthopedic Clinic

CMF OL1000 BONE GROWTH STIMULATION BRIEF PRESCRIBING INFORMATION INDICATION: Noninvasive treatment of an established nonunion acquired secondary to trauma, excluding vertebrae and all flat bones. A nonunion is considered to be established when the fracture site shows no visibly progressive signs of healing. CONTRAINDICATIONS: Use of this device is co traindicated in individuals having a synovial pseudarthrosis. Demand-type pacemaker or implantable cardiovertor defibrillator (ICD) operation may be adversely affected by exposure to magnetic fields. Physicians should not prescribe CMF OL1000 for applications that may place the treatment transducers in close proximity to the pacemaker. Further screening by the attending cardiologist is recommended (such as with an electrocardiogram). CMF OL1000 should not be used in the presence of external or internal fixation devices that are constructed from magnetic materials. (NOTE: Almost all fracture fixation devices implanted today are made from non-magnetic materials.) WARNINGS: The safety and effectiveness of the use of this device on individuals lacking skeletal maturity have not been established. Animal studies conducted to date do not suggest any long-term significant adverse effects from use of this device. However, longterm effects in humans are unknown. Teratological studies have not been performed with this device. The safety of use of this device during pregnancy or nursing in humans has not been established. PRECAUTIONS: Weight bearing is not advised in the presence of extreme motion at the nonunion site. In the presence of a malaligned nonunion, careful consideration of the use of this device must be undertaken on an individual basis, as treatment with this device is not intended to alter or affect the degree of malalignment. The safety and effectiveness of the use of this device on individuals with nonunion secondary to, or in conjunction with, a pathological condition have not been established. This device should not be used if there are mental or physical conditions that preclude patient compliance with the physician and device instructions. When conditions of atrophy are present or when fractures have remained unhealed for long periods of time, there may be less successful results. ADVERSE EFFECTS: No known significant adverse effects have resulted from the use of this device. Clinical studies, animal studies, and tissue culture experiments conducted with the OL1000, which has the same treatment signal as the OL1000 SC1, have not indicated any evidence of significant adverse effects. CAUTION: Federal law (U.S.A. and Canada) restricts this device to sale, distribution or use by or on the order of a physician. CMF OL1000 POSTMARKET PATIENT REGISTRY DATA CMF OL1000 Bone Growth stimulator Post market Patient Registry Data: As of June 30, 1998, the CMF OL1000 had been applied to 5300 patients with physician diagnosed nonunion with varying times from injury, two months or greater. Patient registry data was collected from December 1994 to December 1998. At the time of database closure, we expected follow-up on 4100 patients and received follow-up on 2370 patients (57.8%). Physician diagnosed healing determined patient outcome in the patient registry. All patients were treated for 30 minutes per day, and devices were programmed to provide a maximum of 270 days of treatment. The results of these 2370 patients are presented above. ** The success rate of 51/84 patients in pre-marketing clinical data was 60.7% and was maintained at 2 years post treatment with 90% follow-up of all healed fractures. In the pre-marketing clinical data was 60.7% and was maintained at 2 years post treatment with 90% follow-up of all healed fractures. In the pre-market study nonunion was considered to be established when a minimum of nine months had elapsed since injury and the fracture site showed no visibly progressive signs of healing for a minimum of 3 months. Patient success was defined as three out of four corticies bridged on radiographic and no pain or motion at the fracture site. For additional detailed information on pre-market prospective study, contact DJO. 1. Burge RT, Dawson-Hughes B, Solomon D, et al. Incidence and economic burden of osteoporotic fractures in the United States, 2005 25. J Bone Miner Res. 2007;22:465 75. 2. American Academy of Orthopedic Surgeons. Half of all musculoskeletal injuries occur in the home. Available at: http://www. aaos.org/news/aaosnow/ apr09/clinical9.asp. Accessed Apr 26, 2012. 3. McLeod, K.J., Rubin, C.T., the Effect of Low-Frequency Electical Fields on Osteogenesis. J. Bone Joint Surg., 74A:920-929, 1992. 4. Buckwalter, J.A., et al., Orthopaedic Basic Science: Bone Injury, Regeneration, and Repair, 3rd Edition. AAOS, 2007 5. Mohan, S. Baylink, D.J., Clin. Orthop. Rel.Res. 263:30-48, 1991 6. Ryaby, J.T. et al,. Trans. Orthop. Res. Soc., 19:158, 1994. Ryaby, J.T. et al., The role of insulin-like growth factor in magnetic field regulation of bone formation, bioelectochemisty and bioenergeticws, 35: 87-91, 1994 7. Multicenter Nonunion Clinical Investigation of the DonJoy OL1000 Bone Growth Stimulator, Company Brochure #00-0624, DJO, Vista, CA. DJO, LLC I A DJO Global Company T 800.336.6569 D 760.727.1280 F 800.936.6569 1430 Decision Street I Vista, CA 92081-8553 I U.S.A. DJOglobal.com/cmf 8. Windram, WW and Jacob, JM, Combined Magnetic Field Heals Long Bones of the Foot, DJO Whitepaper #11-2451, DJO, Vista, CA. 9. Hatch R, Alsobrook J, Clugston J. Diagnosis and management of metatarsal fractures. Am Fam Physician. 2007;76:817 26 10. Wu N, Lee Y, Segina D, Murray H, Wilcox T, Boulanger L. Economic Burden of Illness Among US Patients Experiencing Fracture Nonunion. Orthopedic Research and Reviews. 2013;5:21-33. 2013 DJO, LLC 00-1367 Rev A