DIESEL GENERATOR SET DP02500D5S

Similar documents
4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Diesel Generating Set

DIESEL FEATURES GENERATOR SET. FUEL/EMISSIONS STRATEGY Low fuel consumption

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

Diesel Engine Driven Generators Page 1 of 6

STANDBY 800 ekw 1000kVA 60 Hz 1800rpm 480Volts

STANDBY 150 ekw 188 kva PRIME 135 ekw 169 kva

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 480 Volts

DIESEL GENERATOR SETS

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva

Power kva Power kw Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 1

STANDBY 2500 ekw 3125 kva 60 Hz 1800 rpm 480 Volts

GEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

STANDBY 3200 ekw 4000 kva 50 Hz 1500 rpm Volts

DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET

How To Use A Cat Diesel Engine

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

C18 ACERT Fire Pump Tier bkw/ rpm

Technical Specification. Generating Set with Waukesha engine burning natural gas

STANDBY 1500 ekw 1875 kva 60 Hz 1800 rpm 480 Volts

Spark-ignited generator set

1100 Series 1104C-44TAG2 Diesel Engine ElectropaK rpm

Power kva 17,4 18,9 Power kw 13,9 15,1 Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 0,8

GEP150 (3-Phase) 50 HZ 60 HZ. 150 kva / 120 kw FEATURES. Exclusively from your Caterpillar dealer

RENTAL XQ230 SOUND ATTENUATED. DUAL VOLTAGE 50/60 Hz FEATURES

C18 Diesel Oilfield Generator Set

3516 Industrial Engine

NATURAL GAS CONTINUOUS 1000 ekw 1250 kva 50 HZ 1500 RPM 400 Volts

AGP15 Perkins Series Gen Set Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ

Diesel Generator Set Model DFHC 60 Hz

Diesel Generator Set Model DFMB 60 Hz

DIESEL GENERATOR SET FEATURES. FUEL/EMISSIONS STRATEGY Low Fuel consumption

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

HFW-100 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

Marine Generating Sets 3.7 to 50 kva

Annex-A TECHNICAL SPECIFICATION

Atlas Copco Generators

NATURAL GAS CONTINUOUS 725 ekw 906 kva 745 ekw 931 kva 770 ekw 963 kva 50 HZ 1500 RPM 400 VOLTS

3304B. Marine Auxiliary Engine SPECIFICATIONS STANDARD EQUIPMENT ACCESSORY EQUIPMENT PERFORMANCE DATA. 56 bkw (75 bhp) rpm

Power kva Power kw Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 1

Magnum Mobile Generator MMG55 Specifications

IGSA POWER GENERATION SYSTEMS

Diesel Generator Set Model DGDK 60 Hz

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

Specifications for Volkswagen Industrial Engine

How To Control A Power Command Powerplant

XQ20 RENTAL. 60 Hz. Voltage kw (kva) kw (kva) 208/120V 3 PH 20 (25) 18 (22.5) 480/277V 3 PH 20 (25) 18 (22.5) 240/120V 1 PH 17 (17) 16 (16)

A Single Source for all Power System Solutions

Standby Generators FEATURES. Standby Generators Liquid-Cooled Gas Engine. Standby Generators INCLUDES:

Rental. C18-20 XQ600 MULTI-VOLTAGE SOUND ATTENUATED POWER MODULE 60 Hz FEATURES

CAT NEXT GENERATION DIESEL GENERATOR SETS. C15 ACERT and C18 ACERT kva / ekw

1013 E. The engine for agricultural equipment.

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1

APS100 Rental Generator Set Specification

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

Engine Power Plant 5,2 MW Stationary Dual Fuel (Diesel / Gas ) Engine (12 VDS 48/42 )

WÄRTSILÄ 50DF PRODUCT GUIDE

912. The engine for construction equipment.

Signature and ISX CM870 Electronics

RH 12.5 RH Crawler Excavator Specifications

CUKUROVA GENERATOR SYSTEMS

The kva RAnge

Hydraulic Control Solutions

The Yachtmans Choice...

SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 10 kw 12.

Current state of plant Functioning as a peak and emergency centre. Statistics Accumulated operating hours:

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 80 kw 100 kva 60 Hz

Bergen Engines Products and Applications

New 27 hp 2 Cylinder Liquid-Cooled Engine

1 Air-to-Air AfterCooling. 2 Engine Only. Capacity will vary with radiator size and use. of cab heater.

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

WÄRTSILÄ 34DF PRODUCT GUIDE

STANDBY PERMANENT MOUNT SERIES GENERATOR

BHKW. Power. Power. Gas engines for CHP units and gensets. MAN Engines. A Division of MAN Truck & Bus

Fire Pump Plan Review March 2010

PM734F - Technical Data Sheet Winding 28

TECHNICAL SPECIFICATIONS FOR DIESEL GENERATORS 15KVA (CANOPY TYPE)

POWER GENERATION.

CUKUROVA GENERATOR SYSTEMS

3516B Offshore Generator Set

EMERGENCY AND STANDBY POWER SYSTEMS

Note: This information obtained from internet sources and not verified- use at your own risk!!!!

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

CREATING POWER SOLUTIONS. 2L41C 3L41C 3L43C 4L41C 4L42C 4L43C. Hatz Diesel.

Energy-efficient data center achieves 2N reliability; MTU Onsite Energy generator sets provide critical backup

(ui. C) Listed by Underwriters' Laboratories of Canada. 6BTA5.9 F1 LISTED AGENCY RATINGS

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

CUKUROVA GENERATOR SYSTEMS

Citius-sarjan merimoottorit

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Rotary screw compressors kw 5,5 7, , bar MODULO

Diagnostic Fault Codes For Cummins Engines

3516B Offshore Emergency Generator Set

Transcription:

DIESEL GENERATOR SET DP02500D5S 380V 11 kv/50 Hz/Prime/TA-Luft Optimized MTU 20V4000G23/Water Charge Air Cooling Optional equipment and finishing shown. Standard may vary. PRODUCT HIGHLIGHTS // Benefits - Low fuel consumtion - Optimized system integration ability - High reliability - High availability of power - Long maintenance intervals // MTU Onsite Energy is a single-source supplier // Support - Global product support offered // Standards - Engine-generator set is designed and manufactured in facilities certifi ed to standards ISO 2008:9001 and ISO 2004:14001 - Generator set complies to ISO 8528 - Generator meets NEMA MG1, BS5000, ISO, DIN EN and IEC standards - NFPA 110 // Power Rating - System ratings: 2500 kva - 2600 kva - Accepts rated load in one step per NFPA 110 - Generator set complies to G3 according to ISO 8528-5 - Generator set exceeds load steps according to ISO 8528-5 // Performance Assurance Certification (PAC) - Engine-generator set tested to ISO 8528-5 for transient response - 75% load factor - Verifi ed product design, quality and performance integrity - All engine systems are prototype and factory tested // Complete range of accessories available - Control panel - Circuit breaker/power distribution - Fuel system - Fuel connections with shut-off valve mounted to base frame - Starting/charging system - Exhaust system - Mechanical and electrical driven radiators - Medium voltage alternators // Emissions - TA-Luft optimized // Certifications - CE certifi cation option

2 / / / DP02500D5S / 50 Hz / 380V - 11kV APPLICATION DATA ➀ // Engine Manufacturer MTU Model 20V4000G23 Type 4-cycle Arrangement 20V Displacement: l 95.4 Bore: mm 170 Stroke: mm 210 Compression ratio 16.4 Rated speed: rpm 1500 Engine governor ADEC (ECU 7) Max power: kwm 2200 Air cleaner Dry // Fuel System Maximum fuel lift: m 5 Total fuel flow: l/min 27 l/hr g/kwh At 100% of power rating: 585.8 221 At 75% of power rating: 423.4 213 At 50% of power rating: 284.9 215 // Liquid Capacity (Lubrication) Total oil system capacity: l 390 Engine jacket water capacity: l 205 System coolant capacity: l 50 // Combustion Air Requirements Combustion air volume: m 3 /s 3.2 Max. air intake restriction: mbar 50 // Cooling/Radiator System Coolant flow rate (HT circuit): m 3 /h 80 Coolant flow rate (LT circuit): m 3 /h 32.5 Heat rejection to coolant: kw 970 Heat radiated to charge air cooling: kw 470 Heat radiated to ambient: kw 105 Fan power for mech. radiator (40 C): kwm 70 // Exhaust System Exhaust gas temp. (after turbocharger): C 530 Exhaust gas volume: m 3 /s 8.7 Maximum allowable back pressure: mbar 85 Minimum allowable back pressure: mbar 30 ➀ All data refers only to the engine and is based on ISO standard conditions (25 C and 100m above sea level). ➁ Values referenced are in accordance with ISO 3046-1. Conversion calculated with fuel density of 0.83 g/ml. All fuel consumption values refer to rated engine power.

3 / / / DP02500D5S / 50 Hz / 380V - 11kV STANDARD AND OPTIONAL FEATURES // System Ratings (kw/kva) Generator model Voltage TA-Luft optimized 40 C/400m without radiator with mechanical radiator with electr. driven radiator kwel kva* AMPS kwel kva* AMPS kwel kva* AMPS Marathon 1020FDL7093 380 V 2080 2600 3950 2040 2550 3874 2040 2550 3874 (Low voltage 400 V 2080 2600 3753 2000 2500 3608 2000 2500 3608 marathon standard) 415 V 2080 2600 3617 2000 2500 3478 2000 2500 3478 Marathon 1030FDL7094 380 V 2080 2600 3950 2040 2550 3874 2040 2550 3874 (Low voltage 400 V 2080 2600 3753 2000 2500 3608 2000 2500 3608 marathon oversized) 415 V 2080 2600 3617 2000 2500 3478 2000 2500 3478 Leroy Somer LSA 53.2 M80 380 V 2080 2600 3950 2040 2550 3874 2040 2550 3874 (Low voltage 400 V 2080 2600 3753 2040 2550 3681 2040 2550 3681 Leroy Somer) 415 V 2080 2600 3617 2040 2550 3548 2040 2550 3548 Marathon 1030FDH7101 11 kv 2080 2600 136 2000 2500 131 2040 2550 134 (Medium volt. marathon) Leroy Somer LSA 54 XL75 11 kv 2080 2600 136 2040 2550 134 2040 2550 134 (Medium volt. Leroy Somer) * cos phi = 0,8 // Engine 4-Cycle Standard single stage air filter Oil drain extension & shut-off valve Closed crankcase ventilation Governor-electronic isochronous Common rail fuel injection TA-Luft optimized engine // Generator NEMA MG1, BS5000, ISO, DIN EN and IEC standards Self-ventilated Superior voltage waveform Solid state, volts-per-hertz regulator No load to full load regulation ±0,25% voltage regulation no load to full load Brushless alternator with brushless pilot exciter 4 pole, rotating fi eld Sustained short circuit current of up to 250% of the rated current for up to 10 seconds (marathon generator) Sustained short circuit current of up to 300% of the rated current for up to 10 seconds (Leroy Somer generator) Marathon low voltage generator Leroy Somer generator (please contact your local MTU Onsite Energy distribution partner for system ratings) Oversized generator Medium voltage generator Represents standard features Represents optional features

4 / / / DP02500D5S / 50 Hz / 380V - 11kV STANDARD AND OPTIONAL FEATURES, CONTINUATION // Cooling System Jacket water pump Thermostat(s) Water charge air cooling Mechanical radiator Electrical driven front-end cooler Jacket water heater // Control Panel Pre-wired control cabinet for easy application of customized controller (V1+) Island operation (V2) Automatic mains failure operation with ATS (V3a) Automatic mains failure operation incl. control of generator and mains breaker (V3b) Island parallel operation of multiple gensets (V4) Automatic mains failure operation with short (< 10s) mains parallel overlap synchronization (V5) Mains parallel operation of a single genset (V6) Mains parallel operation of multiple gensets (V7) Basler controller Deif controller Complete system metering Digital metering Engine parameters Generator Protection Functions Engine protection SAE J1939 engine ECU communications Parametrization software Multilingual capability Multiple programmable contact inputs Multiple contact outputs Event recording IP 54 front panel rating with integrated gasket Different expansion modules Remote annunciator Daytank control Generator winding temperature monitoring Generator bearing temperature monitoring Differential protection with multi-finction protection relay Modbus RTU-TCP gateway // Circuit Breaker/Power Distribution 3-pole circuit breaker 4-pole circuit breaker Manual-actuated circuit breaker Electrical-actuated circuit breaker Stand-alone solution in seperate switch box // Fuel System Flexible fuel connectors mounted to base frame Fuel filter with water separator Switchable fuel filter with water separator Seperate fuel cooler Fuel cooler integrated into cooling equipment // Starting/Charging System 24V starter Starter batteries Battery rack & cables Battery charger Represents standard features Represents optional features

5 / / / DP02500D5S / 50 Hz / 380V - 11kV STANDARD AND OPTIONAL FEATURES, CONTINUATION // Mounting System Welded base frame Resilient engine and generator mounting Modular base frame design // Exhaust System Exhaust bellows with connection flange Exhaust silencer with 10 db(a) sound attenuation Exhaust silencer with 30 db(a) sound attenuation Exhaust silencer with 40 db(a) sound attenuation Y-connection-pipe Represents standard features Represents optional features

6 / / / DP02500D5S / 50 Hz / 380V - 11kV WEIGHTS AND DIMENSIONS Drawing above for illustration purposes only, based an standard open power 400 Volt engine-generator set. Lengths may vary with other voltages. Do not use for installation design. See website for unit specific template drawings. System Dimensions (L x W x H) Weight (dry/less tank) Open Power Unit (OPU) 6176 x 1810 x 2332 mm 18339 kg Weights and dimensions are based on open power units and are estimates only. Consult the factory for accurate weights and dimensions for your specific engine-generator set. SOUND DATA // Consult your local MTU Onsite Energy distributor for sound data. EMISSIONS DATA NO x + NMHC CO PM 1700 300 50 All units are in mg/nm 3 Emission levels of the engine may vary as a function of ambient temperature, barometric pressure, humidity, fuel type and quality, installation parameters, measuring instrumentation, etc. The data provided refers to ISO standard ambient conditions (25 C and 100m above sea level). The data provided are laboratory results from one engine representing this rating. The data was obtained under controlled environmental conditions with calibrated instrumentation. RATING DEFINITIONS AND CONDITIONS // Prime power ratings apply to installations where utility power is unavailable or unreliable. At varying load, the number of generator set operating hours is unlimited. A 10% overload capacity is available for one hour in twelve. Ratings are in accordance with ISO 8528-1, ISO 3046-1, BS 5514, AS 2789 and DIN 6271. Average load factor: < 75%. // Deration factor: Altitude: Consult your local MTU Onsite Energy Power Generation distributor for altitude derations. Temperature: Consult your local MTU Onsite Energy Power Generation distributor for temperature derations. Rated power is available up to 40 C and 400m above sea level. Subject to change. 3237691 Edition 02/14 ENC 2014-04. Materials and specifications subject to change without notice. MTU Onsite Energy A Rolls-Royce Power Systems Brand www.mtuonsiteenergy.com