Product Certificate. DORMA-Glas GmbH herewith confirms that the product

Similar documents
Product Management - Glass ALEXA PRODUCT PRESENTATION. Region SAARC Nitin Lloyd, Product Management. Chennai, FY 2013 / 2014

K17.12 Door closers K17. Doors

Security steel door dw 52-1 Teckentrup DF WK 2 optionally with glazing/ventilation grille

Sliding and Folding Door Fittings Sliding Door Accessories

Lift-off hinge. Rising hinge. Standard hinge. Heavy duty hinge. Parliament hinge. Spring hinge. Double action spring hinge. Concealed mortise hinge...

Universal systems for frameless doors

How To Fit A Portman Door Leaf

CLEAR-DIVISIONS CENTERFOLD

SECTION 6. Glass Storefront Doors:

Ref: GA13UK Glass Awning Support System

ARCHITECTURAL. FritsJurgens Pivot Door System Product Range Brochure

CLEAR-DIVISIONS VARIOFOLD

BLADE S-MAX Cabinet for Blade Server

The complete range. Shower Hardware Doors & Partitions Balustrades Post Railings Glass Windscreens Glass Canopies

DIGITUS Network & Server Cabinets. UNIQUE Series

Technical manual for ordering and installation DORMA MANET. Single-point fixings for interior applications

AMS 120. EFT Guest Card Terminal & Refund unit

Linkeo 19" freestanding cabinets

Reduced depth High Density Cabinet HDC with 19 swing frame 36, 40 and 45 U

Integral Kit Instructions

EXTeRUS. EXTeRUS - With patented design, able to join technology. and quality of materials with a charming shape. Unique

Evidence of Performance Resistance to wind load Watertightness Air permeability

INSTALLATION INSTRUCTIONS

bts 80 f/emb/flb/bsr Floor spring system

Heavy Duty Lift Doors for Trade and Industry

Approved Document Q: Security

DE Frame with C Series Sidelight

STAR Linear Bushings and Shafts Supplement RE / Linear Motion and Assembly Technologies

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

glass & Glazing Products

900 series. Flat panel Floor stands. The 900 series Flat panel Floor stands.

2.02. Specifications. General. Products. Execution. Offset Pivots P-694 Top and Bottom Pivots

CLEAR-DIVISIONS APERTO

Cable Trays Technical Instructions & Specifications

Narrow stile lock 1314

PHA 2000 PHB 3000 EXIT PAD

Code of Practice for fire resisting metal doorsets

AMF Line; wall absorbers Wall mounted acoustic designs PERFORMANCE CEILINGS. M ore s c op e f or i n n ovat i on MADE IN GERMANY

CATALOGO PRODOTTI PORTONI INDUSTRIALI COIBENTATI

Windows, French doors, folding windows, terrace doors SFB 1074 with low U-values

House Design Tutorial

Aluminium systems profile selection

Relevant British, European and International standards

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

Preface nivtec.com 3

CERTIFICATE OF APPROVAL No CF 291 SCHOTT UK LIMITED

19 DYNAmax Free Standing Server C A B I N E T s

CHARISMA SHOWER/TUB DOOR INSTALLATION INSTRUCTIONS

19 DYNAmax Free Standing Server C A B I N E T s

HMMA 810 HOLLOW METAL DOORS HOLLOW METAL MANUAL -87 NAAMM STANDARD FOURTH EDITION METAL DOORS & FRAMES NAAMM 2 NAAMM 2 METAL DOORS & FRAMES

ISSUE 2. Installation Guide

Up-And-Over Garage Doors

Residential Garage Door Terminology

REFRIGERATION. Standard Features & Accessories. Model Options. Built-In 30 W. Full-Height Wine Cellar. All models include. VCWB300 Professional

Networking Cabinets > Part No Capacity Available Colors Height(mm) Width(mm) Depth(mm)

Vacuum drying oven for non-flammable solvents

Glass and Building Regulations Impact Safety

Can you design a frameless shower enclosure that doesn't leak?

n Three 4 x 4 butt hinges per door - prevents wracking and assures smooth positive operation n Heavy duty 16 gauge steel frame

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

Now available with full IP65 rating: Protection from dust and water jets NEW: K470 Plus covered containers

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

Horizontal Mini Blinds Installation Guide

Knürr Miracel. Knürr Miracel. 19 Network and Server Rack Platform 1.12 to

Confort 160. Sliding Systems. Sapa Building System

mechanics PP-Profiles Panel Profiles PT-Profiles T-Groove Plates RE-Profiles Rectangular Profiles PU-Profiles Universal Profiles

BAKA Protect Series 2000 / Protect. The adjustable hinge system for timber entrance doors

Architectural Hardware Design Guide High-performance hardware for the most demanding architectural applications

Technical data sheet PVC Bi-fold doors

Technical catalogue convectors POLAND 2012

ARCHITECTURAL. CEAM INVISIBLE HINGES new adjustable 3D concealed hinge products for swing doors 100% made in Italy

DIRECTIONS FOR ASSEMBLING BASE & WALL CABINETS

All-round interior organiser systems for office furniture Systema Top 1000 and OrgFrame

TOPLIGHTS. NOTE: 2.4m high sliding doors are only available in certain configurations and sizes.

contents classic 3 switch 4 mini swing 5 sign wedge 6 chalkboards 7 all purpose A frames 8 H2O swingmaster 9 café banner 10 vision 11

majestic install ation guide barcelona three sided enclosure 24mm surface mounted wall channels and underframe to base

Guide to Safety Edge Systems

Planning Information. Passenger and Freight Elevators.

Attachment of supporting fitting components for turn-only and tilt&turn fittings

Garage Sectional Doors

Speed-Mat Rectangle Cutter

Automatic Door Selection Guide

EXIT HARDWARE. Uniclass L CI/SfB (31.59) Xt7 VERSION: AUGUST-11. An ASSA ABLOY Group brand

NoteLocker 8 NoteLocker 8 as a Floor-standing Solution

INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the FTP

39HQ Airovision Air Handling Units

CI/SfB. (31.59) X NOVEMBER 2003 Coburn Interior Sliding Systems

Squash Court Design general points

CONCEALED BEARING HINGES. StANLEy ARCHItECtuRAL HARDwARE

HINGES FOR OUTWARD OPENING APPLICATIONS. Friction Hinges. Parts Brochure

HMMA 830 HARDWARE SELECTION FOR HOLLOW METAL DOORS AND FRAMES HOLLOW METAL MANUAL -02 NAAMM STANDARD METAL DOORS & FRAMES NAAMM 01 NAAMM 01

Novoferm Interior Doors and Frames Just what you re looking for

Installation Instructions

Technical Information

Ceiling Mounted Folding Attic Ladders Installation Instructions

[ means: Save time, money and space! MAXXMILL 500. Vertical milling center for 5-side machining

Wren Kitchens Installation Tips Carefully check your kitchen delivery Measuring out and marking up Fitting the base cabinets...

Installation Detailed installation instructions are provided which should be strictly followed.

Installation Instructions K900 series Door Closer

RADAR

Transcription:

herewith confirms VISUR double-action door system has successfully completed a durability test aligned to EN 1154. This was conducted on the basis of a representative test series in which the fittings were applied to an all-glass door weighing 85 kg. Dimensions of the door leaf (width x height) 1100 mm x 2500 mm, toughened safety glass The door satisfied the requirement specified in EN 1154 of successfully completing 500,000 operating cycles. Further, pendulum impact tests were also carried out using a 40 kg pendulum. Test 1: Point of impact in the area of the rotating axis, 900mm above the floor surface. Pendulum drop height 305 mm. Test 2: Point of impact in the area of the primary closing edge, 900mm above the floor surface, during door closure in the opposite direction. Pendulum drop height 305 mm. The door satisfied the requirement: Functionally intact after pendulum impact test. Bad Salzuflen, 21 June, 2007 Head of Mechanical Design Germany

BEYOND Pivoting have been tested in an endurance test according to European EN 1154 standard. This took place in a series of exemplary tests; the fittings were mounted to a glass-door with 80 kg weight. Door width: 1000mm, door height: 2200mm. The corner patch fitting fulfils the demand given by the German DIN standard: 500.000 operations (cycles) Bad Salzuflen, 28.04.2006

Swing Door System MANET has been tested in an durability test according to DIN EN 1154. The fittings were mounted to an exemplarily glass door of 80, 100, 120kg (plus safety multiplier) weight. Please use a door closer type EN4 (with or without back check) or a higher type (e.g. EN5) WITHOUT back check. This certificate applies to the following conditions/limits: Variant Without continuous pivot bar With continuous pivot bar and 4 single point fixings With continuous pivot bar and 5 single point fixings Panel Weight Glass Thickness Door Width Door High 80kg >/=10mm </=2500mm 100kg >/=10mm </=1200mm </=2600mm 120kg >/=12mm </=3000mm Using in Variant V2A Variant V4A environments without influences of chloride and sulphur dioxide environments with moderate influences of chloride and sulphur dioxide able not able able able swimming and/or saline baths not able on enquiry For additional technical information s please check the actual technical prospect for DORMA-Glas. Bad Salzuflen, 18/12/2008 Division Glas Head of Mechanical Design and Development

Junior Office Band Hinges for/with frame pivots has been tested according to the EN1527. The product meets the following standards: Maximum door weight: Count of operations: 60kg (24mm rebate depth with sleeve and steel ball bearing) 55kg (24mm rebate depth with sleeve) 45kg (rebate depth >24mm up to 40mm) class 7 (200.000 cycles) Corrosion resistance: class 3 Glass type: TSG Glass thickness [mm]: 8, 10 Glass surface: clear, calendered, no using of self-cleaning surfaces (Lotus, Clear-Shield etc.) Classification key EN1935: 2 7 3 0 1 3 0 10 Bad Salzuflen, 21/04/2008 Division Glas Head of Mechanical Design and Development

Junior Office hinge with steel ball bearing Art.-Nr. 11.234 was tested according to the EN1935:2002 regarding durability and according to the EN1670:2007 regarding corrosion resistance with the following results: Maximum door weight: Durability: Corrosion resistance: 60kg Level 7, EN1935:2002 200.000 operations Level 3, EN1670:2007 Bad Salzuflen, 14.01.08 Division Glas Head of Mechanical Design and Development

Junior lock have been tested according to german DIN 18251 standard. This took place in an endurance test. The locking bolt fullfills the demand 50.000 operations The ledge fullfills the demand 200.000 operations Bad Salzuflen, 28.04.2006

Studio lock have been tested according to german DIN 18251 standard. This took place in an endurance test. The locking bolt fullfills the demand 50.000 operations The ledge fullfills the demand 200.000 operations Bad Salzuflen, 28.04.2006

Door rail with BTS-insert Art.-No. 04.101 Top patch Art.-No. 03.110 has been tested in an endurance test acording to EN 1154. This took place in a series of exemplary tests; the fittings were mounted to a glassdoor with 100 kg weight. Door width: 1100mm, Door height: 2000mm. The complete door fulfils the demand 500.000 operations (cycles) Bad Salzuflen, 28.04.2006

ARCOS Top Patch Fitting Art.-No. 26.110 ARCOS Bottom Patch Fitting Art.-No. 26.100 have been tested in an endurance test according to European EN 1154 standard. This took place in a series of exemplary tests; the fittings were mounted to a glass-door with 100 kg weight. Door width: 1000mm, door height: 2200mm the corner patch fitting fulfils the demand given by the German DIN standard: 500.000 operations Bad Salzuflen, 21.06.2007

Top Patch Fitting Art.-No. 03.110 Bottom Patch Fitting Art.-No. 03.100 has been tested in an durability test according to DIN EN 1154. The fittings were mounted to an exemplarily glass door of 130 kg (plus safety multiplier) weight. This certificate applies to the following conditions/limits: count of operations: </= 500.000 door width </= 1.300mm door height </= 2.500mm For doors with more than 100kg weight please use a door closer type EN4 (with or without back check) or a higher type (e.g. EN5) WITHOUT back check. For doors with a height of more than 2.500mm additional the following conditions/limits has to be observed: glass thickness >/= 10mm Usage of a handle bar with 3 connection points in minimum and a minimum height of 2/3 door height. Bad Salzuflen, 1/25/2008

Overpanel Patch Fitting Art.-No. 03.120 has been tested in an endurance test according to EN 1154 a glassdoor of 101 kg weight was fitted with PT10/PT 20, attached to 2 x PT 30 with wall bracket Art.-No. 01.127 on wall. Overpanel fixed to ceiling with wall connecting profile Art.-No. 07.042. The fittings fulfilled the demand 500.000 operations Bad Salzuflen, 28.04.2006

Overpanel and Sidepanel Patch Fitting Art.-No. 03.140 has been tested in an endurance test according to EN 1154. a glassdoor of 101 kg weight was fitted with PT10/PT 20, attached to a PT 40 on pirot side and a PT 30 on lock side. PT 30 fixed to wall with bracket Art.-No. 01.127. Overpanel fixed to ceiling with wall connection profile Art.-No. 07.042. The fittings fulfilled the demand 500.000 operations Bad Salzuflen, 28.04.2006

DORMA-SM Type 1010 1046 Latest drawing revision 2005 has been tested in an durability test according to EN1154. The fittings were mounted to an exemplarily glass door of 80kg (safety multiplier not included) weight. This certificate applies to the following conditions/limits: count of operations: </= 200.000 door width </= 1.100mm door height </= 2.300mm door weight </= 80kg After 200.000 operations all installed parts have to be checked according the following items: mechanical fractures screw torques precise position of the fittings Please use a door closer type EN4 only. Further technical information are given in technical documentation. Bad Salzuflen, 16/01/2009 Head of Mechanical Design and Development