BROCADE FASTIRON SX SERIES SWITCHES FREQUENTLY ASKED QUESTIONS

Similar documents
Solutions Guide. High Availability IPv6

Brocade Campus LAN Switches: Redefining the Economics of

Get the Most Out of Data Center Consolidation

Building Tomorrow s Data Center Network Today

Designing a Robust and Cost-Effective Campus Network

Higher Education Campus

FASTIRON II SWITCHES Foundry Networks award winning FastIron II family of switches provides high-density

Scalable Approaches for Multitenant Cloud Data Centers

Brocade Solution for EMC VSPEX Server Virtualization

INDIAN INSTITUTE OF TECHNOLOGY BOMBAY MATERIALS MANAGEMENT DIVISION : (+91 22) (DR)

Multi-Chassis Trunking for Resilient and High-Performance Network Architectures

Axia-Approved Ethernet Switches

Meraki MS22 / MS42 Cloud Managed Gigabit PoE Switch Family

Combining the Best of Chassis-Based and Stackable Switches

PRODUCT DETAILS 3Com Switch 4500 Family 1 de 9 03/03/2008 9:43

MS Cloud Managed Gigabit Switch Series

48 GE PoE-Plus + 2 GE SFP L2 Managed Switch, 375W

BROCADE OPTICS FAMILY

Feature Support Cisco 2960 Cisco 2960S Brocade ICX 6450 Brocade ICX GE SFP, 2 10GE SFP+, 4 1GE SFP, 2 DUAL PURPOSE PORTS, 1GE OR SFP

SummitStack in the Data Center

Lab Testing Summary Report

Brocade Solutions for iscsi Storage Area Networks

Arista 7060X and 7260X series: Q&A

How To Connect Virtual Fibre Channel To A Virtual Box On A Hyperv Virtual Machine

Datasheet. Managed PoE+ Gigabit Switches with SFP. Models: ES-8-150W, ES W, ES W, ES W, ES W, ES W

SummitStack in the Data Center

VIRTUAL CHASSIS TECHNOLOGY BEST PRACTICES

BROCADE IP - INTELLIGENT NETWORKS

Cisco Catalyst 4500-X Series Switch Family

EX SERIES ETHERNET SWITCHES

Datasheet. Managed Gigabit Switches with SFP. Models: ES-24-Lite, ES-48-Lite. Non-Blocking Throughput Switching Performance

Brocade SDN 2015 NFV

Brocade MLX Series Architecture

TechBrief Introduction

White Paper. Network Simplification with Juniper Networks Virtual Chassis Technology

BILOXI PUBLIC SCHOOL DISTRICT. Ethernet Switches

Enterprise LAN Switches. Key Features. Key Benefits. Switch 4500 Series

Datasheet. Managed Gigabit Fiber Switch. Model: ES-12F. Non-Blocking Throughput Switching. High Performance and Low Latency

Datasheet. Managed PoE+ Gigabit Switches with SFP. Models: ES W, ES W, ES W, ES W

Allied Telesis provide virtual customer networks

Server Consolidation and Remote Disaster Recovery: The Path to Lower TCO and Higher Reliability

DATA CENTER. Best Practices for High Availability Deployment for the Brocade ADX Switch

Switch Types, Blade IDs, and Product Names

Catalyst update & Local Manufactory

EX 3500 ETHERNET SWITCH

Brocade One Data Center Cloud-Optimized Networks

EX SERIES ETHERNET SWITCHES

WHITE PAPER. Copyright 2011, Juniper Networks, Inc. 1

20 GE + 4 GE Combo SFP G Slots L3 Managed Stackable Switch

Dell Force10. Data Center Networking Product Portfolio. Z-Series, E-Series, C-Series, and S-Series

ALLNET ALL-SG8926PM Layer 2 FULL Management 24 Port Giga PoE Current Sharing Switch IEEE802.3at/af

Dyrehavsbakken Amusement Park

DEDICATED NETWORKS FOR IP STORAGE

Guidelines Introduction

Brocade SDN/OpenFlow. Norival Figueira Office of the CTO. January 9, /2015 BROCADE COMMUNICATIONS SYSTEMS, INC. ALL RIGHTS RESERVED.

VCS Monitoring and Troubleshooting Using Brocade Network Advisor

New Features in Cisco IOS Software Release 12.2(33)SXI2

Cisco SLM248P 48-Port 10/ Port Gigabit Smart Switch: SFPs/PoE

BROCADE FASTIRON SX SERIES

Application Note Gigabit Ethernet Port Modes

10 Gigabit Aggregation and Next-Gen Edge 96-Port Managed Switch Starter Kits

24 Gigabit Fiber Copper PoE Switcher Series. Network Transmission Products 24 Gigabit Fiber Copper PoE Switcher Series. Overview

Gigabit to the edge. HP ProCurve Networking Solutions

Nutanix Hyperconverged Appliance with the Brocade VDX ToR Switch Deployment Guide

Key Benefits. 10 Gigabit Backplane Interface. show that the MS-7206 has. 12 outstanding performance for enterprises to perform real-time

Cisco IOS Software Release 12.2(31)SGA for Cisco Catalyst 4500 Series Supervisor Engines

Cisco SFS 7000P InfiniBand Server Switch

Fibre Channel over Ethernet: Enabling Server I/O Consolidation

Building Private Cloud Storage Infrastructure with the Brocade DCX 8510 Backbone

Deploying Brocade VDX 6720 Data Center Switches with Brocade VCS in Enterprise Data Centers

The Road to SDN: Software-Based Networking and Security from Brocade

How To Build A Cisco Uniden Computing System

Cisco Small Business Managed Switches

Installation and Basic Configuration Guide

Supermicro Standalone Switch Products

Cisco Catalyst 4500E Supervisor Engine 7-E: Leading Borderless Network Access and Aggregation Supervisor Engine

Ethernet Link SGI-2424

Gigabit Network Switches

An Oracle White Paper October How to Connect Oracle Exadata to 10 G Networks Using Oracle s Ethernet Switches

Enterprise Switches. Accelar 8000

High Performance 10Gigabit Ethernet Switch

20 GE PoE-Plus + 4 GE PoE-Plus Combo SFP + 2 GE SFP L2 Managed Switch, 370W

Multitenancy Options in Brocade VCS Fabrics

Cisco ASR 9001-S Router

AT-S95 Version AT-8000GS Layer 2 Stackable Gigabit Ethernet Switch Software Release Notes

Meraki Stacking. White Paper

Product Brief Ethernet Routing Switch 5500 Series

Dell PowerVault MD Series Storage Arrays: IP SAN Best Practices

Cisco SFS 7000D Series InfiniBand Server Switches

Cisco Catalyst 3750 Metro Series Switches

Ethernet Link SGI-4844F

System. A Product Concept Introduction ORACLE WHITE PAPER JUNE 2015

Calix E7-2 Ethernet Service Access Platform

How To Get The Most Out Of A Pon From Commscope

Cisco Catalyst 2960-X Series

Brocade and EMC Solution for Microsoft Hyper-V and SharePoint Clusters

Industry-based CLI (Cisco like) and Networking OS graphical user interface

IP SAN Best Practices

Cisco SRW2024P 24-Port Gigabit Switch: WebView/PoE Cisco Small Business Managed Switches

Transcription:

FAQ BROCADE FASTIRON SX SERIES SWITCHES FREQUENTLY ASKED QUESTIONS Introduction The Brocade FastIron SX Series of switches provides an industry-leading price/performance value for campus aggregation and core switching, delivering a scalable, secure, low-latency, and fault-tolerant infrastructure for 1 Gigabit Ethernet (GbE) and 10 GbE enterprise deployments. The FastIron SX series provides a high-performance, non-blocking architecture and a high-availability design with redundant and hot-pluggable management modules, fans, load-sharing switch fabrics, and power supplies. For product information, visit www.brocade.com/products/all/switches/product-details/fastiron-sx-series/index.page. General Questions and Answers Q What environment is the Brocade FastIron SX Series primarily designed for? A The FastIron SX Series is primarily designed for the aggregation layer and the campus core of typical enterprise Ethernet network architectures. The campus aggregation switches (FastIron SX 800 or FastIron SX 1600) provide Ethernet connectivity to uplink connections from the access switches, such as the Brocade FCX Series or the Brocade ICX 6610, deployed in wiring closets. The campus aggregation switches are uplinked to the campus core where the FastIron SX 1600 switches are deployed, creating the campus network. The FastIron SX Series switches are built for high performance and maximum system availability, and feature redundant management modules with hitless failover, redundant fans and power supplies, redundant load-sharing switch fabrics, and hot-swappable line modules. Some organizations prefer chassis-based solutions for wiring closets to support their Voice over IP (VoIP) environments. The FastIron SX switches support Power over Ethernet/Power over Ethernet Plus (PoE/PoE+) modules with redundant, load-sharing PoE power supplies, making them also an ideal choice as a wiring closet solution. In this way, the FastIron SX Series provides a single, cost-effective platform for use as access, aggregation, and core chassis, simplifying spares and support.

Q What are the key highlights of the FastIron SX Series? A The FastIron SX Series is an industry-leading price/performance value for campus aggregation and core switching, providing a scalable, secure, low-latency, and faulttolerant infrastructure for cost-effective deployment of VoIP, wireless, and high-capacity data services throughout the enterprise. Additional product highlights include: High-performance non-blocking architecture with 8- and 16-slot chassis providing up to 132 10 GbE or 384 wire-speed 1 GbE ports in a single chassis supporting IPv4/IPv6-capable Layer2/3 switching and routing High-availability design with redundant and hot-pluggable management modules (with hitless failover), switch fabrics, power supplies, fans, stateful OSPF redundancy, graceful BGP and OSFP restarts, and hitless (in-service) software upgrades Embedded sflow per port to support scalable hardware-based traffic monitoring across all switch ports without compromising performance Q What are the different modular slots on the FastIron SX 800 and FastIron SX 1600 switches? A The FastIron SX 1600 chassis has 16 interface slots, two management slots, two fabric slots, and eight power supply slots. The FastIron SX 800 chassis has eight interface slots for Ethernet interface modules, two management slots, two fabric slots, and four power supply slots. All modular components, except for fan assemblies, are common between the two chassis. Q How many 1 GbE and 10 GbE ports can be supported? A Each FastIron SX 1600 chassis can support 384 1 GbE PoE ports, 324 PoE+ ports, 384 100/1000 Mbps Small Form-Factor Pluggable (SFP) ports, or 132 10 GbE ports. Each FastIron SX 800 chassis can support up to 192 1 GbE PoE ports, 162 PoE+ ports, 192 100/1000 Mbps SFP ports, or 68 10 GbE ports. Q What are the slot bandwidth and switching capacity of the FastIron SX Series? A For the FastIron SX 800 chassis, per-slot bandwidth is 60 Gbps; backplane switching capacity is 600 Gbps; data switching capacity is 464 Gbps; and packet-forwarding capacity is 348 MPPS. For the FastIron SX 1600 chassis, per-slot bandwidth is 60 Gbps; backplane switching capacity is 1080 Gbps; data switching capacity is 848 Gbps; and packet-forwarding capacity is 636 MPPS. Q Does the FastIron SX Series have the option for a redundant system power supply? A Yes. The FastIron SX Series enables an optional redundant system power supply to be installed internally. These power supplies provide power to the management module, all non-poe interface modules, and all ports on PoE modules that do not require PoE power or to which no power-consuming devices are attached. The FastIron SX 800 requires one system power supply, and a second power supply provides (1+1) redundancy. The FastIron SX 1600 requires two system power supplies and can be installed with up to four system power supplies for (N+1) redundancy. Q What are the functions of the PoE power supplies? A The PoE power supplies provide power to the PoE circuitry on the I/O cards and ultimately to the PoE/PoE+ GbE ports. FastIron SX 800 supports up to two PoE power 2 of 7

supplies for 1+1 redundancy. FastIron SX 1600 supports up to four PoE power supplies for N+1 redundancy. The number of PoE/PoE+ power-consuming devices that one PoE power supply can support depends on the power consumption (class) of the connected devices. If there are no PoE power supplies installed, the PoE/PoE+ capable interface modules will operate as standard 10/100/100 Mbps Ethernet modules. Q Does the FastIron SX Series offer AC and DC power? A Yes. AC and DC power supply models are available for system power and PoE/PoE+. They are auto-sensing and auto-switching. The 2500 W PoE power supply is available only as an AC power supply. Q Are the power supplies hot-swappable? A Yes. The system and PoE power supplies are hot-swappable and can be removed and replaced without powering down the system. Q Is there load sharing between the system and the PoE power supplies? A No. Power consumption between PoE and system power supplies is not shared, meaning loss of a system power supply does not impact a PoE power supply, and vice versa. The system power supplies will load share between the other installed system power supplies, and the PoE power supplies will load share between the other installed PoE power supplies. Management, Fabric, and Interface Modules Q Can you share the modules between the FastIron SX 800 and FastIron SX 1600? A Yes. Interface modules, management modules, and fabric modules are common and can be shared between FastIron SX 800 and FastIron SX 1600 chassis. Q What does third-generation interface modules mean? A FastIron SX third-generation interface modules were introduced in November 2011. Unlike earlier modules, they have the unique capability to run with either IPv4 or IPv6 management modules and operate with either IPv4 or IPv6 interface modules in the same chassis. These modules also have the hardware capability to support MACsec Layer 2 security and Energy Efficient Ethernet (EEE) standards (RJ-45 module only). These modules consist of the SX FI-8XG (eight 10 GbE SFP+ ports), SX FI-2XG (two 10 GbE SFP+ ports), SX FI-24HF (24 1 GbE SFP ports), and SX FI-24GPP (24 1 GbE RJ-45 PoE+ ports). The SX-FI48GPP is also a third-generation module, but does not support MACsec or EEE. Q Can the IPv4 and IPv6-capable modules of the FastIron SX Series be mixed in a chassis? A No. IPv4-only first-generation and IPv6-capable second-generation modules or management modules cannot coexist in the same chassis. IPv4-only interface modules can be used only in a chassis with IPv4-only management modules. Likewise, IPv6- capable interface modules can be used only in a chassis with IPv6-capable management modules. The 48-port 10/100/1000 Mbps interface module introduced in mid 2010 and the third-generation interface modules introduced in November 2011 operate with either IPv4-only or IPv6-capable modules. 3 of 7

Q What are the functions of the management module? A Each FastIron SX chassis requires at least one management module to control the FastIron SX hardware components and the separate switch fabric modules, and to run Brocade IronWare software and the networking protocols. There are two types of management modules for the FastIron SX Series: With no ports With two 10 GbE XFP ports either an IPv4-only or IPv6-capable version Q Do the management modules have switching fabric designed on board? A No. There is no fabric on board the management modules for the FastIron SX Series. A separate fabric module is required in each FastIron SX chassis. Q Can you deploy a second management module for redundancy? A Yes. The FastIron SX chassis has two management module slots to accommodate up to two management modules that can be operated in active/standby redundancy mode. Both modules need to be of the same port configuration type. IPv6 and IPv4-only modules cannot be mixed in the same FastIron SX chassis. IronWare release 7.2 and later also provide hitless failover capability, which automatically switches to the standby management module in the event of a management module failure, without any interruption to packet forwarding. Q Do I need a fabric module in the FastIron SX chassis? What does this module do? A Yes, a fabric module is required in the FastIron SX chassis. It is needed to switch data packets between interface modules installed in the FastIron SX chassis. The fabric modules consist of multi-lane cross-bar switch fabrics to provide non-head-of-lineblocking switching. Q Two slots are available for fabric modules. What s the advantage of using two fabric modules? A The fabric module can be operated in a standalone or redundant fashion. Using two fabric modules provides fabric redundancy and full non-blocking switching performance in the FastIron SX 1600. If one of the fabric modules fails, there is still connectivity between the interface modules and the management modules, and between the management modules themselves. The FastIron SX 800 provides non-blocking performance with one switch fabric; the second fabric is used for resiliency. Q How does the FastIron SX Series support non-stop networking? A First, the Brocade FastIron SX features Multi-Chassis Trunking (MCT), which enables two FastIron SX chassis to appear as a single logical switch at Layer 2 in active/active mode and delivers uninterrupted traffic flow in the event of node failover. Second, the FastIron SX Series can support two separate management modules per chassis. These modules operate in a redundant fashion (both must be the same type). The hitless failover capability in IronWare 7.2 and later enables the redundant management module to take over the operation when the primary module fails, without a system reboot. Third, two separate fabric modules can operate in a redundant fashion. Furthermore, up to two system (AC/DC) and two PoE/PoE+ (AC/DC) power supplies can be used to support the power requirements of the system. Additionally, the FastIron SX supports protocol 4 of 7

resiliency with VSRP for Layer 2, VRRP, and VRRP-E for Layer 3 operating in an active/standby mode. Q What interface modules are available for the FastIron SX Series? A The following Ethernet interface modules are available for the FastIron SX chassis for connecting endpoint devices: 8-port 10 GbE SFP+ interface module 2-port 10 GbE SFP+ interface module 24-port 100/1000 Mbps fiber SFP interface module 24-port 10/100/1000 Mbps PoE+ interface module 48-port 10/100/1000 Mbps PoE+ interface module 24-port 10/100/1000 Mbps non-poe interface module 24-port 10/100/1000 Mbps PoE interface module 2-port 10 GbE XFP interface module Q Do the 10 GbE modules also support 1 GbE? A No. The 10 GbE modules are not dual speed and do not support 1 GbE optics. Q What is the switching capacity between interface modules? A The maximum switching capacity between any two interface modules is 60 Gbps (the switching capacity and design are identical for FastIron SX 800 and FastIron SX 1600 chassis). The 60 Gbps capacity between interface modules ensures non-blocking, linerate performance for a fully loaded interface module independent of traffic distribution through the switch. Q What is the maximum port density of the FastIron SX 800 and FastIron SX 1600 switches? A The table below provides the port capacity of the FastIron SX Series switches: Port Type SX 800 SX 1600 Per Switch Per Rack Per Switch Per Rack 100 Base FX (SFP) 192 1344 384 1152 1000 Base X (SFP) 192 1344 384 1152 No 10/100/1000 RJ-45 192 1344 384 1152 PoE 10 GbE BaseX (SFP+) 64 448 128 384 10 GbE BaseX (XFP) 20 140 36 108 IEEE 802.3af Class-3 10/100/1000 Mbps 192 1344 384 1152 PoE IEEE 802.3af Class-3 10/100/1000 Mbps With N+1 Power Supply Redundancy 166 1162 384 1152 IEEE 802.3at 10/100/1000 Mbps 162 1134 324 972 PoE+ IEEE 802.3at 10/100/1000 Mbps With N+1 Power Supply Redundancy 81 567 244 732 5 of 7

Q What are the key highlights of the new 48-port GbE switch module? A The FastIron SX Series 48-port GbE switch module with RJ-45 interfaces provides industry-leading price/performance for an enterprise-class chassis switch. Key functionality of this module includes a full suite of security features, PoE/PoE+ with superior power efficiency, and compatibility with the IPv4 and IPv6 FastIron SX chassis. Q Is PoE+ standards-based on the 48-port GbE module? A Yes. Power over Ethernet Plus, or PoE+, is being driven by the IEEE 802.11at standard, which is currently at draft 4. The FastIron SX module is draft 4-compliant and will be upgradable to support the final 802.11at specification. PoE+ can deliver up to 30 watts of power per port. Q Is PoE+ backward-compatible with PoE? A Yes. 801.11at PoE+ is fully backward-compatible with 802.11af PoE. Leveraging LLDP- MED, the module auto-negotiates 802.11af Class 1, Class 2, and Class 3 power. Q Are the interface, management, and fabric modules hot-swappable? A Yes. The IPv6-capable management module, switch fabric, and interface modules are hot-swappable, which means a module can be removed and replaced while the chassis is powered on and running. Q Is the fan module hot-swappable? A Yes. The fan unit can also be hot-swapped while the FastIron SX unit is running. It is recommended that the fan be replaced soon after it is removed. Q How is the FastIron SX Series managed? A The FastIron SX Series supports a wide range of network management standards, has an industry-standard Command Line Interface (CLI), and can be managed along with the rest of the Brocade Ethernet network by Brocade Network Advisor. Q What is new in the IronWare 7.3 software release for the FastIron SX Series? A IronWare 7.3 provides the following key functionalities to support non-stop networking and protocol enhancements: New third-generation interface modules New OSPFv3 IPSec Authentication 802.1X Guest VLAN per port SNTP MD5 authentication SSHv2 client support and SSHv2 broadcast support VRRP/VRRP-E IPv6 Q What are the different FastIron SX software upgrade options? A The base management modules support full Layer 2 switching and basic Layer 3 routing with static routes and RIP advertisement. The PREM software for the IPv4-only systems and 6-PREM software for IPv6-capable systems enable full IPv4 unicast and multicast routing functionality. The 6-PREM6 software for the IPv6-capable systems includes all of the IPv4 routing features of the 6-PREM software with the addition of full IPv6 routing functionality. Additionally, the 6-PREM and 6-PREM6 include GRE tunneling functionality. 6 of 7

Services and Support Q What technical support services come standard with the purchase of the product? A To further improve service levels and operational efficiency, Brocade includes one year of free technical support on the FastIron SX 800 and FastIron SX 1600, providing access to software fixes and direct access to the Brocade Technical Assistance Center and resources on a 24 7 basis. The one-year free support term begins when the chassis ships from the factory. While product registration is not required, it is recommended to ensure that customers receive timely product support, product update information, and other benefits. Q What is the product warranty coverage for the FastIron SX Series? A FastIron SX Series switches are covered by the Brocade Assurance Limited Lifetime Warranty. For details, visit www.brocade.com/warranty. Learn More Q How do I find out more about the Brocade FastIron SX Series? A Go to www.brocade.com and navigate to the Brocade FastIron SX Series product page for the latest data sheets, white papers, and solutions briefs, or contact your Brocade sales representative or Brocade OEM Partner for more details. 2012 Brocade Communications Systems, Inc. All Rights Reserved. 02/12 Brocade, Brocade Assurance, the B-wing symbol, DCX, Fabric OS, MLX, SAN Health, VCS, and VDX are registered trademarks, and AnyIO, Brocade One, CloudPlex, Effortless Networking, ICX, NET Health, OpenScript, and The Effortless Network are trademarks of Brocade Communications Systems, Inc., in the United States and/or in other countries. Other brands, products, or service names mentioned may be trademarks of their respective owners. 7 of 7