DIGITECH PRO 1000/1600/2200 VA

Similar documents
How To Use A Power Supply Unit (Upu)

User s Manual AURORA 1.2K/2.2K

Line Interactive UPS

Line Interactive UPS. PowerWalker VI 500T/HID PowerWalker VI 750T/HID PowerWalker VI 1000T/HID PowerWalker VI 1500T/HID.

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

Online UPS. PowerWalker VFI 1000R/1U

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual

Line Interactive UPS. Cheerups. Cheerups. Installation and Operation Manual. An ISO 9001:2008 Company. C he erup s

Powerware 5110 UPS User s manual

User Manual 1K/2K/3K Online UPS

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

Installation and Operation Back-UPS 1250, 1300, 1500

User s Manual Before using the inverter, you need to read and save the safety instructions.

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

USER MANUAL Online UPS 1K/2K/3K

User s Manual. Professional Rack Mount LCD Series PR1000ELCDRT2U/PR1500ELCDRT2U/ PR2200ELCDRT2U K

HP UPS R1500 Generation 3

USER MANUAL Online UPS 1K/2K/3K Rack

350, 500, 650 and 1000 MODELS

3000W Power Inverter

Owner s Manual. Not suitable for mobile applications. Important Safety Instructions 2. Quick Installation 3. Basic Operation 4. Storage & Service 7

How To Use A Power Supply Unit (Upland)

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Back-UPS Pro 1300/1500 Installation and Operation

Uninterruptible Power Supply

User Manual. English. APC Smart-UPS 500 VA 100 VAC 750 VA 100/120/230 VAC. Tower Uninterruptible Power Supply

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

Model #: SMART2200CRMXL

User Manual. English. APC Smart-UPS 1000/1500 VA 100/120/230 VAC 750/1000XL VA 120/230 VAC. Tower Uninterruptible Power Supply

User Manual. English. APC Smart-UPS SC. 1000/1500 VA 110/120/230 Vac. 2U Tower/Rack-Mount Uninterruptible Power Supply

EKOS Cart. Instructions for Use

Operation Manual. Smart-UPS C. Uninterruptible Power Supply. Tower 1000/1500 VA. 120/230 Vac. su0813a

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

SPL 2-00/-01 OPERATION INSTRUCTIONS

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

ekil 3 KGK tecrübesi olmayan herhangi bir ki i tarafından çalı tırılabilir.

Home Solar Kit Owner s Manual. Model: HS

Battery Power Inverters

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

User Manual HomeGrid 3000 Solar Generator

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

esata External Storage

10000HXL31/15000HXL31/20000HXL31

CAUTION. CAUTION indicates a potentially hazardous situation which, if not avoided, can result in equipment damage and minor or moderate injury.

Digital Photo Picture Frame. Operation Manual

UPS VA User s Manual

Preface. Manual Revisions

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

NeTYS PR VA

AutoRanging Digital MultiMeter

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

Point of view HDMI Smart TV dongle Mini RF Keyboard

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Dehumidifier Users manual. For Models: DH45S DH65S

User Manual. English. APC Smart-UPS VA 120/230 Vac VA 100/120/208/230 Vac. 2U Rack Mount Uninterruptible Power Supply

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

Table Of Contents

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

=============================== WARNING

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

TIG INVERTER INSTRUCTION MANUAL

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

MULTI XS Battery charger. For lead-acid batteries 1,2-120Ah

PAR Tablet 10 Quick Start Guide

Use and Care Manual. Model CPA12KH AIR CONDITIONER

RUNNING A BUSINESS IS FUN, BUT IT S ALSO HARD WORK

UPS OPERATING INSTRUCTIONS PROTECT A. PROTECT A. 500 PROTECT A. 700

Manual Ranging MultiMeter

1. User Safety Instructions

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

How To Use A Sata Dsa Hard Disk Storage System

Internet Office 750VA Ultra-compact Standby 120V UPS with USB port

BUB-110B. Portable Power Pack. Compact USB Battery Charger for up to 5 Smartphones and Mobile Devices. User Manual

CHARGING SYSTEMS INTERNATIONAL

Indoor Remote Controlled Power Points

BITMAIN. APW PSU Series User Guide

Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

750VA/1000VA/1500VA 100/120/230VAC 2U

TABLE OF CONTENTS QUICK START... 1 DIAGRAM OF THE DIGITAL PHOTO FRAME... 2 KEYPAD BUTTON FUNCTIONS... 3 REMOTE CONTROL FUNCTIONS..

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

ST Series POWER SUPPLIES USER INSTRUCTIONS

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Microwave Oven. Warning: a) This oven is not for commercial use. b) Don't open the cover of the machine except professional person.

Lithium Jump Starter and DC Power Source

AC Power For Business-Critical Continuity. Liebert PSI. User Manual 750/1000/1500/2200/3000, 230VAC

Transcription:

DIGITECH PRO 1000/1600/2200 VA UNINTERRUPTIBLE POWER SUPPLY UPS USER MANUAL ENGLISH

Product Overview 1000 VA / 1600 VA / 2200 VA Front View Back View 1 Power Switch 1 USB Communication Port 2 LCD Display 2 3 RJ 11/45 Protection Port AC Input 4 5 Output Receptacles Fan 1000 VA 1600 VA / 2200 VA

LCD Display Input Voltage Line Mode Battery Mode Output Voltage Load Level Battery Level Over Load Low Battery Fault Product Features Modern, stylish concept Today the IT users not only want functional products, but also nice looking products which they will enjoy to see every day. Digitech Pro is a unique design and has a display which looks up, if you think 90% of the UPS work under your table on the floor; this makes the user to see the display without bending down. Multi funtion LCD display with voltage meter Digitech Pro has his own way of communicating to it s user; you can see many information from the LCD display like the input/output voltage, load level, battery level, overload etc. CPU control for reliability Digitech Pro is a digital UPS which has a high speed CPU ensuring that it does all of it s functions right and on time. This very critical especially for protection of the UPS; as all the overload, overvoltage, undervoltage protections and controlled digitally by the CPU, it provided exceptional reliability to the UPS. Simulated sine wave Digitech Pro provides simulated sinewave form which is suitable PC and IT equipment.

Buck and boost AVR function Digitech Pro acts as a voltage stabilizer as well, if the line voltage is too high it will reduce it to the normal limits or if there is a brownout, Digitech Pro UPS will increase the voltage level to protect it s connected equipment. USB communication port and software Digitech Pro comes with a CD and USB cable, you can connect your Digitech Pro UPS to your PC via the USB port. When you load the software to your computer (Windows, Linux or Mac compatible), you can monitor your UPS from your monitor or you can program your UPS on how to function in case of a power failure. Digitech Pro is a smart UPS and can be controlled through your computer or it can make a orderly shutdown by saving all your application data, closing your software and shutting down your operating system and finally shutting down your computer. Charging when UPS is off Your UPS can charge it s batteries even when it is not working, you don t have to leave your UPS on order to charge your batteries at night. Your Digitech Pro will safely charge it s batteries even if it s not switched on. RJ 11/45 (modem/internet) protection port Digitech Pro is equipped with a special protection port to protect your, telephone line or modem against power surges. Overload, low and high voltage protection Digitech Pro provides full reliability by providing several electronic protections to ensure a problem-free long life product. As an example, you can not damage your Digitech Pro by an accidential overloading, it will sense the load and protect itself without any hardware damage. Low-and high-voltage protection High capacity battery Most UPS systems will charge their battery to full in 8 to 10 hours, but Digitech Pro can fill it s batteries in 4 hours to ensure a safe operation in regions where electric failures are very often.

DON T CONNECT A LAZER PRINTER TO THE UPS UNIT Installation and initial startup Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. Install the UPS in a protected area that is free of excessive dust and has adequate air flow. Do NOT operate the UPS where the temperature and humidity is outside the specific limits. (Please chech the technical specs for the limitations) Please place the UPS away from other units at least 20cm to avoid interference. Connect to utility and charging Plug in the AC input cord to the wall outlet. The unit charges its battery while connecting to the utility. For the best results, suggest to charge the battery at least 6 hours before initial use. THIS MAY CAUSE THE DAMAGE OF THE UNIT Connect the loads Plug in the loads to output receptacles on the rear panel of the UPS. Simply turn on the power switch of UPS unit, then devices connected to the UPS will be protected by UPS unit. Turn On/Off the unit Turn on the UPS unit by pressing the power switch. Turn off the UPS unit by pressing again the power switch. Power Switch

SAFETY - WARNING This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user serviceable parts. Only factory service personnel may perform repairs. Internal battery voltage is 12Vdc. Sealed, lead-acid, 6 cells battery. Connection to any other type of receptacle other than a two-pole, three-wire grounded receptacle may result in shock hazard as well as violate local electrical codes. In the event of an emergency, press the Smart On/Off Button for 4 seconds and disconnect the power cord from the AC power supply to properly disable the UPS. Do not allow liquids or any foreign object to enter the UPS. Do not place beverages or any other liquid-containing vessels on or near the unit. This unit intended for installationina controlled environment (temperature controlled, indoor area free of conductive contaminants). Avoid installing the UPS in locations where there is standing or running water, or excessive humidity. Do not plug the UPS input into its own output. Do not attach a power strip or surge suppressor to the UPS. Do not attach to non-computer-related items, such as medical equipment, life-support equipment, microwave ovens, vacuum cleaners, lazer printers or washing machine. To reduce the risk of overheating the UPS, do not cover the UPS cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space heaters or furnaces. Unplug the UPS prior to cleaning and do not use liquid or spray detergent. Do not dispose of batteries in a fire as they may explode. Do not open or mutilate the battery or batteries. Released electrolyte is harmful to the skin and eyes. lt may be toxic. Attention, hazardous through electric shock. Also with disconnection of this unit from the mains, hazardous voltage still may be accessible through supply from battery. The battery supply should be therefore disconnected in the plus and minus pole of the battery when maintenance or service work inside the UPS is necessary. Servicing of batteries should be performed by authorized personnel. Keep unauthorized personnel away from batteries. A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed when working on batteries: 1) Remove watches, rings, or other metal objects from the hands. 2) Use tools with insulated handles. 3) Wear rubber gloves and boots. 4) Do not lay tools or metal parts on top of batteries. 5) Disconnect charging source prior to connecting or disconnecting batteries terminals. When replacing batteries, replace with the same number and type of sealed lead-acid battery. The maximum ambient temperature raling is 40 C. This pluggable type A equipment with battery already installed by the supplier is operatar installable and may be operated by laymen. During the installation of this equipment it should be assured that the sum of the leakage currents of the UPS and the connected loads does not exceed 3.5 ma. The mains socket outlet that supplies the UPS shall be installed near the UPS and shall be easily accessible.

TROUBLE SHOOTING Use the table below to solve minor problems. Problem No LED display on the front panel Possible Cause Low battery Battery fault Solutions Charge the UPS at least 6 hours Replace the battery with the same type of battery (Please see Safety-Warning page) The UPS is not turned on Press the On/Off button at least 1 second to turn on the UPS Alarm continuously sounds when the mains is normal The UPS is overload Remove some loads first. Before reconnecting equipment, please verify that the load matches the UPS capability specified in the specs. (Please see Technical Specification table) When power fails, back-up time is shorten The UPS is overload Battery voltage is too low Remove some critical load Charge the UPS at least 6 hours Battery defect. It might be due to high temperature operation environment, or improper operation to battery. Replace the battery with the same type of battery (Please see Safety-Warning page) The mains is normal but LED color in red is flashing Power cord is loose Reconnect the power cord properly, if the problem can t be solved please consult nearest technical service

TECHNICAL SPECIFICATIONS CAPACITY INPUT Voltage Voltage range OUTPUT Voltage range Transfer time Waveform BATTERY Type & Number Charging time DIMENSIONS AND WEIGHT Dimensions D x W x H (mm) Net weight (kg) ENVIRONMENT Humidity Noise level 1000 VA 600 W 1600 VA 960 W 220/230/240 VAC 162-265 VAC ± %10 2-6 ms, 10 ms max. Simulated sine wave 12V 7Ah x 2 12V 9Ah x 2 4-6 hours recover to 90% capacity 392 x 177 x 211 8.4 10,7 11,45 0-40 C 0-90% (non-condensing) < 40 dba 2200 VA 1320 W