BUCHHOLZ RELAYS BR 1 /0 APPLICATION

Similar documents
RY2 miniature industrial relays

OLI. Oil level indicator

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34

HERZ-Thermal Actuators

Elektromotoren und Gerätebau Barleben GmbH

60 Series - General purpose relays 6-10 A. Features

Elektromotoren und Gerätebau Barleben GmbH

Oil and Coolant Circulating Heating System. Model - OCSM

3/2-way Solenoid Valve, direct-acting, NC or NO

V94 BULK TAPE DEGAUSSER

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Residual current socket 30mA Order No.:

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

Pluggable interface relays CR-P Pcb relays

RM4TG20 three-phase network control relay RM4-T - range V

DISCONTINUED (1998) FBR46 SERIES. MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) RoHS compliant FEATURES

4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS FEATURES

Circuit Breakers. NRC Series. NRC Series

49 Series - Relay interface modules A. Features

R.C.C.B. s two-pole LEXIC

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Unified requirements for systems with voltages above 1 kv up to 15 kv

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

SELECTION, APPLICATION AND MAINTENANCE

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

Safety technique. Emergency stop module BO 5988 safemaster

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

48 SERIES Relay interface modules 10 A

Series 8146/5-V37 and Series 8150/5-V37

Unit 24: Applications of Pneumatics and Hydraulics

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

3/2- and 2/2-way cartridge valve type BVE

Assisted lift operated 2/2-way solenoid valves Type EV250B

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

How To Build A Low Voltage Capacitor Lvcp

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

understanding medium frequency induction melting furnace and its components

Thermometer in stainless steel with capillary and switch contacts

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

MOUNTING AND OPERATING INSTRUCTIONS

Generator Stator Protection, under/over voltage, under /over frequency and unbalanced loading. Ramandeep Kaur Aujla S.NO

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Electric Rotary Actuator - On/Off or programmable control actuator

40 Series - Miniature PCB/Plug-in relays A. Features

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

Linear Luminaire with LED Series EXLUX 6402/2

Solenoid valves 2/2-way direct-operated Type EV210A

IFC 070 Technical Datasheet

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

TQ SMD RELAYS TQ SMD LOW-PROFILE SURFACE-MOUNT RELAY FEATURES SPECIFICATIONS

Rotary actuators Rotary wing drives Series RAK. Brochure

Messko. Messko. MTraB - Maintenance Free Dehydrating Breather Ordering specifications XX - XX - XXX - XX

Ordering Information. Latching Relay G2AK. Model Number Legend Magnetic Latching Version of G2A Ideal for Sequence Control

LAUBE TECHNOLOGY DRY REED RELAYS

MEMBRANE VACUUM MINI PUMPS

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

Diesel Engine Driven Generators Page 1 of 6

4 Posiflow Proportional Solenoid Valves

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

SMS 4 / SMS 5 safety mat Product information

1 POLE - 5A SLIM POWER RELAY

8146/5 Series Breaker Panelboards

Operators manual Basic water heater

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

38 Series - Relay interface modules A

Digital inductive conductivity transmitter

Electro-pneumatic control valves

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Liquid Level Limit Switch liquiphant T FTL 20

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Thermistor motor protection

How To Use A Power Supply Unit (Upu)

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Instruction Bulletin. MCS025 Sync-Check Module Installation Sheet

Electronic overload relay EF19 and EF45

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

Intersection Preassembled 19-inch Rack

System 8. ü ( System 8

SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A

Please also see 10 golden rules for correct Saniflo installation on

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Transcription:

APPLICATION Buchholz Relay is a protection device for monitoring the gas and oil movements in oil immersed transformers. It is designed to detect the faults and minimize the propagation of any damage which might occur within oil circuit, induction coils etc. The examples of the faults which could cause gas accumulation or strong oil flows in the oil circuit are as follows; short-circuited core laminations broken-down core insulation overheating of windings bad contacts short-circuit between phases earth faults puncture of bushing insulators inside tank falling of oil level due to leaks ingress of air as a result of defective oil circulation system CONSTRUCTION ELMEK relays, structurally consist of two main sections, i.e., main housing and upper housing which are both made of corrosion-resistant aluminum alloy and covered with electrostatic powder paint. These sections are also resin treated to seal possible micropores. Main Housing Depending on the model, screw or flange type connections are available. On each side, there are graduated inspection glass windows which enable the volume of gas to be read off and the contact system to be examined. The inspection windows have also additional metal protection covers against external hazards. Upper Housing Upper housing holds all the inside mechanisms and also fitted with a cable terminal box, a breather cock and a test button for the mechanical release of the floats to test the alarm circuits. Cable terminal box incorporates the base mounted electrical connection parts and earth terminal, and has a cover for external hazard protection. Breather cock is generally used to exhaust the air in the relay and to take out gas samples. The inside mechanism comprises upper and lower contact systems for alarm and tripping positions. Both contact systems includes; a float made of oil resistant, closed cellular type special plastic foam a magnet and a mechanical or mercury contact Additionally, lower contact system is also fitted with a deflector plate for oil flow sensing. Single float Buchholz relay has only one contact system together with the deflector plate. OPERATION PRINCIPLE During normal operation, the relay is completely filled with oil keeping the floats in their top limit or rest position. The contact mechanisms in the relays respond to; slight faults causing a slow evolution of gas in the transformer, serious faults creating immediate oil surge, oil leakages. Slight Faults When a slight or incipient fault occurs in the transformer, the small bubbles of gas, which pass upwards towards the oil conservator tank, are trapped in relay housing, thus causing its oil level to fall. As a result, the upper float rotates on its hinge and operates the alarm switch, thus operating an external alarm device. Serious Faults When a serious fault, core insulation break-down, short circuits etc., occurs in the transformer, the gas generation is violent and causes the oil rush through the Buchholz Relay to the oil conservator tank. In the relay, this oil surge impinges on the deflector plate fitted on the lower float and causes the rotation of the float itself, thus operating the tripping contact and disconnecting the transformer. Oil Leakage An oil leak in the transformer causes the oil level in the relay to fall, thus operating first the alarm (upper) float and then the tripping (lower) float. The ingress of air into the transformer, arising from the defects in the oil circulation system operates the alarm float. BR 1 /0

TECHNICAL SPECIFICATIONS Electrical Nominal Voltage Nominal Current Insulation Voltage Oil : AC / DC 230V : AC / DC 2 A : AC 2000 V Type : Transformer oil Permissible temperature range : -25 C to 115 C Viscosity : 1mm 2 /s 1100mm 2 /s Response conditions of the contact systems Gas accumulation : 200 cm³ - 300 cm³ Oil flow velocity : 0.65 m/s, (± 15%) 1.00 m/s, (Default) 1.50 m/s. Deflector plate reaction time : max. 0.5 s. Ambient Temperature range : -40 C to +60 C Protection Class : IP 54 Shock resistance Earthquake : max. 2 g (at 5 to 15Hz seismic wave frequency) Vibration : max. 1 g (at vibrations of the sinusoidal wave form with 16 to 720 Hz frequency) Impacts : max. 10 g (at shocks of the half-sinusoidal wave form with a duration of 10 ms) FINAL TESTS The following tests are applied to the relays (100%) at the end of the production line; Leakage test The relays are filled with oil at the temperature of 90 C and at the pressure of... bars and checked for the leakage after min. 30 minutes. Electrical test Earthing insulation of the connections is checked at the voltage of 2000V, 50Hz for 1 minute. Functional test All the relays are tested on specially designed PLC controlled testing unit and all the response conditions of the contact systems are checked. ASSEMBLY INSTRUCTIONS The following conditions should be verified for the best results; On the relay, there is an arrow showing the direction of the assembly (from the transformer to the oil conservator tank) The relay should always be full of oil. Therefore, the minimum oil level in the conservator should always be above the breather cock of the relay. The relay should be assembled horizontally to ensure correct operation of the floats. A maximum inclination of 4 with respect to the horizontal axis towards the conservator tank is allowed. The pipe which connects the transformer to the relay should come out from the uppermost part of the transformer cover. BR 2 /0

ORDERING SYSTEM Purchase orders should be given in Buchholz Relay Type 01-08 accordance with the following chart. TYPE CODE NO BRC25 F16 ( - ) 221 BRC25 V16 ( - ) 231 BRC25 V50 ( DG-25) 241 BRR25 F50 ( DR-25) 251 BRR50 F100 ( DR-50) 261 BRR80 F100 ( DR-80) 271 BRR80 KF100 ( DQ-80) 281 BRR 25 UF16 211LU BRR 25 KF16 221KL BRR50 UF100 261LU BRR 50 UC-F100 261UC BRR 80 U F100 271LU BRR 80 UC-F100 271UC UPPER CONTACT SYSTEM CONTACT CODE MERCURY CONTACT * C * STANDART REED RELAY R CHANGEOVER REED RELAY W WITHOUT CONTACT 0 LOWER CONTACT SYSTEM CONTACT CODE MERCURY CONTACT * C * STANDART REED RELAY R CHANGEOVER REED RELAY W OIL FLOW OIL FLOW SPEED SPEED SETTING SETTING CODE 0,65 m / s 1 1,00 m / s 2 1,50 m / s 3 COLOR DESCRIPTION COLOR CODE RAL 7033 3 RAL 7037 7 Example : BRR25-F50 : 251-R-R-2-3 * Mercury contact for 1,2,3,4 type no only. BR 3 / A

TYPE TABLE CODE NO. Item No Type No (DIN Code) Connection Nom.-Pipesize d 1 Flange dim. Equipment dim. d 2 d 3 d 4 d 5 f b l h 1 h 2 Wei ght (kg) Transformer Power Class 221 01 BRC 25 F16 Flanged 25 100 75-11.5 10 138 160 190 80 3.2 5000 KVA 231 02 BRC 25 V16 Screwed G 1½ A 25 - - - - 25 138 185 184 80 2.8 5000 KVA 241 251 261 271 281 03 BRR 25 V50 (DG-25) 04 BRR 25 F50 (DR-25) 05 BRR 50 F100 (DR-50) 06 BRR 80 F100 (DR-80) 07 BRR 80 KF100 (DQ-80) Screwed G 1½ A 25 - - - - 25 180 185 184 68.5 3.7 5000 KVA Flanged 25 115 85 68 14 16 180 200 188 68.5 4.1 5000 KVA Flanged 50 165 125 102 18 16 180 195 213 65 5.3 5000 KVA 10000 KVA Flanged 80 200 160 138 18 18 180 195 230 65 6.3 10000 KVA Square Flanged 80 125 132-18 20 180 200 193 65 5 10000 KVA BR 4 / A

TYPE TABLE CODE NO. Item No Type No (DIN Code) Connection Nominal Pipesize Flange dim. Equipment dim. Weight (kg) d 1 d 2 d 3 d 4 d 5 f b l h 1 h 2 Transformer Power Class 211LU 08 BRC 25 UF16 Flanged 25 100 75-11,5 10 138 240 190 80 3.4 1600 KVA 221KL 09 BRR 25 KF16 Square Flanged 25 80 72 - M10-138 127 144 80 3.2 1600 KVA 261LU 10 BRR50 UF100 Flanged 50 165 125 102 18 16 180 240 213 65 6 5000 KVA 10000 KVA 271LU 11 BRR 80 U F100 Flanged 80 200 160 138 18 18 180 240 230 65 7 10000 KVA BR 5 / A

DIMENSIONS BR 6 / B

DIMENSIONS BR 7 / A

CONTACT TYPES CONTACT TYPES For all types. For 1,2,3,4 types. Construction Reaction System Mode of Operation Single Float Buchholz Relay Float Gas accumulation Oil leakage Contact Scheme (Positions of the contacts are given for normal positions, i.e. floats are at top rest position) Normally open Contact 1 2 Changeover Contact 4 1 2 Deflector plate Oil flow 21 22 24 21 22 Gas accumulation Top float Twin Float Buchholz Relay Bottom float Oil leakage Oil leakage UPPER CONTACT 11 12 UPPER CONTACT 14 11 12 Deflector plate Oil flow LOWER CONTACT LOWER CONTACT BR 8 / A