ISO rd Edition

Similar documents
ISO 13485:201x What is in the new standard?

Reporting Changes to your Notified Body

ISO 9001:2015 Overview of the Revised International Standard

Want to know more about the Notified Body?

Clinical evaluation Latest development in expectations EU and USA

Medical Devices. Notified Bodies and the CE certification Process for Medical Devices. European Surgical Robotics Demonstration Day

Risk Management and the Impact of EN ISO 14971:2012 Annex Z

ISO-9001:2000 Quality Management Systems

ISO 9001: 2008 Boosting quality to differentiate yourself from the competition. xxxx November 2008

BSI Unannounced Audits

Revision Date Author Description of change Jun13 Mark Benton Removed Admin. Manager from approval

ISO 9001:2000 Gap Analysis Checklist

PROPOSED DOCUMENT. Quality management system Medical devices Nonconformity Grading System for Regulatory Purposes and Information Ex-change

ISO 9001:2008 Quality Management System Requirements (Third Revision)

AS9100:2016 Transition Guide

Quality Management System Certification. Understanding Quality Management System (QMS) certification

QW Enterprises, LLP. Quality Manual

ISO 9001:2000 AUDIT CHECKLIST

Row Manufacturing Inc. Quality Manual ISO 9001:2008

Internal Quality Management System Audit Checklist (ISO9001:2015) Q# ISO 9001:2015 Clause Audit Question Audit Evidence 4 Context of the Organization

I S O G AP A N A L Y I S T O O L

ISO 9001 : 2000 Quality Management Systems Requirements

ISO 9001 : 2008 QUALITY MANAGEMENT SYSTEM AUDIT CHECK LIST INTRODUCTION

DNV GL Assessment Checklist ISO 9001:2015

White paper. Corrective action: The closed-loop system

Quality Manual TABLE OF CONTENTS APPROVAL SIGNATURE PAGE AMENDMENT RECORD SCOPE EXCLUSIONS 2.1 3

GENERIC STANDARDS CUSTOMER RELATIONSHIPS FURTHER EXCELLENCE CUSTOMISED SOLUTIONS INDUSTRY STANDARDS TRAINING SERVICES THE ROUTE TO

Quality Manual ISO 9001:2015 Quality Management System

Vigilance Reporting. Vicky Medley - Head of QMS, Medical Devices. September Copyright 2015 BSI. All rights reserved.

QUALITY MANAGEMENT SYSTEM REQUIREMENTS General Requirements. Documentation Requirements. General. Quality Manual. Control of Documents

Correlation matrices between 9100:2009 and 9100:2016

Preparing yourself for ISO/IEC

Moving from ISO 9001:2008 to ISO 9001:2015

Konformitätsbewertung 3.9 B 17. Guidance for Notified Bodies auditing suppliers to medical device manufacturers

ISO 9001 (2000) QUALITY MANAGEMENT SYSTEM ASSESSMENT REPORT SUPPLIER/ SUBCONTRACTOR

Comparison between FDA QSR and ISO 13485

ISO 9001: 2015 EXPECTATIONS OVERVIEW & Presenter Name Paul J. Kunder. Former US Representative to ISO 20 Yrs. Voting Member USTAG - TC 176

ISO 14001:2004 vs. ISO 14001:2015

Quality Management System Manual

The Prophotonix (UK) Ltd Quality manual

Preparation for ISO OH&S Management Systems

ISO 9001:2015 Revision overview

UL Qualified Firestop Contractor Program Management System Elements. March 13, 2013

How to manage the transition successfully ISO 9001:2015 TOP MANAGEMENT - QUALITY MANAGERS TECHNICAL GUIDE. Move Forward with Confidence

INTRODUCTION TO ISO 9001 REVISION - COMMITTEE DRAFT

RECALLS in EUROPE. Past, present, near & further future. Gert Bos BSI Medcon May 2012

AEROSPACE STANDARD. Quality Management Systems - Requirements for Aviation, Space and Defense Organizations RATIONALE

LinkTech LLC 3000 Bunsen Ave. #A Ventura, CA 93003

QUALITY MANUAL ISO Quality Management System

QUALITY MANUAL ISO 9001:2015

Quality Management Systems Manual

ISO 9001 & ISO Revisions what will change, and why?

Medical Device Software Do You Understand How Software is Regulated?

Quality Management System MANUAL. SDIX, LLC Headquarters: 111 Pencader Drive Newark, Delaware 19702

QUALITY MANAGEMENT SYSTEM Corporate

Update: Proposed Medical Device Regulation (MDR) & IVD Regulation (IVDR)

Quality Management System MANUAL. SDIX, LLC Headquarters: 111 Pencader Drive Newark, Delaware 19702

FINE LOGISTICS. Quality Manual. Document No.: Revision: A

ISO 9001:2008 Audit Checklist

Medical Device Software Standards for Safety and Regulatory Compliance

Medical Device Training Program 2015

Guidance for manufacturers and Notified Bodies on reporting of Design Changes and Changes of the Quality System

AS9100 Quality Manual

QUALITY MANUAL REVISION RECORD

Karas Engineering AS9100 QUALITY MANAGEMENT SYSTEM MANUAL

Free Download ISO/TS 16949:2009. Requirements Checklist. 29 of 57 pages (PDF) For additional information see

UNDERSTANDING THE EC DIRECTIVE 98/79/EC ON IN VITRO DIAGNOSTIC MEDICAL DEVICES

ISO 9001:2015 Internal Audit Checklist

Revision of ISO 9001 Quality Management Systems Requirements

Introduction to AS 9100

The new ISO standard Standard Template

NOTICE. Re: GD210: ISO 13485:2003 Quality Management System Audits Performed by Health Canada Recognized Registrars

SUPPLIER QUALITY MANAGEMENT SYSTEM QUESTIONNAIRE

Document: ISO/TC 176/SC 2/N 1147

Quality Management System Manual

Supplier Quality Management System Audit Checklist (ISO 9000:2000, TS 16949:2002)

Changes to Medical Device Regulations

The President of Inductors Inc. is the senior executive responsible for operations.

Summary of GE Healthcare's Quality Management System (QMS) Covering BioProcess chromatography media, equipment, software, and spare parts

Quality Management System Manual

ISO/IEC 27001:2013 webinar

Chapter 2 ISO 9001:2008 QMS

ISO/TMB/JTCG N 359. N0359 JTCG FAQ to support Annex SL. Document type: Other committee document. Date of document:

PUBLICATIONS. Introduction

ISO 9001:2008 QUALITY MANUAL. Revision B

ISO 9001:2008 Quality Systems Manual

Vigilant Security Services UK Ltd Quality Manual

Updates on CD/ISO 9001:2015

GOOD DISTRIBUTION PRACTICE FOR MEDICAL DEVICES (GDPMD)

Eagle Machining, Inc. Quality Management System

ISO 9001 and the Supply Chain

9100:2016 Series of Standards Frequently Asked Questions (FAQs)

Presentation by BSI on the main changes to the IATF ISO/TS certification scheme

Control No: QQM-02 Title: Quality Management Systems Manual Revision 10 07/08/2010 ISO 9001:2008 Page: 1 of 22

Gap Analysis of ISO 15189:2012 and ISO 15189:2007 in the field of Medical Testing

ISO 9001:2008 Requirements Explained - An Adobe PDF File for Use on a Network System

Quality Systems Manual

Transcription:

ISO 13485 3 rd Edition Stewart Brain QMS Certification Lead, Medical Devices Copyright 2015 BSI. All rights reserved. 1

1 - Current ISO 13485:2003 & EN ISO 13485:2012 2 - ISO 9001:2015 3 - ISO 13485:2016 4 - Key Changes in ISO 13485:2016 5 - Potential Timings Copyright 2015 BSI. All rights reserved. 2

ISO 13485:2003 & EN ISO 13485:2012 Copyright 2015 BSI. All rights reserved. 3

What is the difference? ISO 13485:2003 The current International Standard EN ISO 13485:2003 The previous version of the European Harmonised Standard Obsolete as of 30 August 2012 EN ISO 13485:2012 Changes within Foreword & Annex Zs only No change to requirements (Normative Text) Annex Z s to provide greater clarity on applicability & alignment with AIMDD, MDD & IVDD Copyright 2015 BSI. All rights reserved. 4

Example EN ISO 13485:2012 Annex ZB Relationship between Annex II of 93/42/EEC and clauses of ISO 13485 Copyright 2015 BSI. All rights reserved. 5

ISO 9001:2015 Copyright 2015 BSI. All rights reserved. 6

New ISO Management Systems High Level Structure New and revised ISO MS Standards now using ISO Annex SL: A standard for standard writers Provides a 10 clause high-level structure and common text Standardises terminology for fundamental Management System requirements Follows the Plan Do Check Act (PDCA) principle Copyright 2015 BSI. All rights reserved. 7

New ISO 9001:2015 10 Clause Structure Copyright 2015 BSI. All rights reserved. 8

The Future Copyright 2015 BSI. All rights reserved. 9

ISO 13485:2016 Based on the Final Draft International Standard (FDIS) of 29 October 2015 Copyright 2015 BSI. All rights reserved. 10

ISO 13485:2016 What s New? What s been put in? What s come out? What s the same? Copyright 2015 BSI. All rights reserved. 11

ISO 13485:2016 What s New? Many additions Some new requirements Some expansion & clarification Increased clarity of interrelationship between clauses and requirements Copyright 2015 BSI. All rights reserved. 12

Regulatory Requirements ISO 13485:2003 FDIS ISO 13485:2016 Regulatory requirements Appears 9 times Appears 37 times Copyright 2015 BSI. All rights reserved. 13

Objectives and Scope ISO 13485:2003 ISO 13485:2016 Objectives Scope & Role Facilitate harmonization Organizations provide Medical devices and related services Facilitate global alignment Organizations can be involved in one or more stages of the life-cycle including the design and development, production, storage and distribution, installation, or servicing of a medical device and the design and development or provision of associated activities (e.g. technical support). This International Standard can also be used by suppliers or external parties that provide product including quality management system-related services to such organizations. Copyright 2015 BSI. All rights reserved. 14

Definitions ISO 13485:2003 ISO 13485:2015 Clause 3 Active implantable medical device Active medical device Advisory notice Customer complaint Implantable medical device Labelling Medical Device Sterile medical device Advisory notice Authorized representative Clinical evaluation Complaint Distributor Implantable medical device Importer Labelling Life cycle Manufacturer Medical device Medical device family Performance evaluation Post market surveillance Purchased product Risk Risk management Sterile barrier system Sterile medical device Copyright 2015 BSI. All rights reserved. 15

Changes to Clause Numbering Due to the inclusion of several new clauses, several sub-clauses have been re-numbered. This presentation covers changes to content, not every sub-clause re-number. In order to work with the MDSAP program of determining levels of non-conformance grading, the clauses and sub-clauses required formatting * See GHTF Document SG3 N19 Copyright 2015 BSI. All rights reserved. 16

4 Quality Management System 4.1-2 4.1.3-5 4.1.6 4.2 General Requirements General requirements General Requirements Documentation Requirements + Document role(s) undertaken by organization under regulatory requirements + Risk based approach to control QMS processes Records to meet regulatory requirements. Change control For outsourced processes control based on risk and ability + Requirement to validate the computer software used for QMS prior to initial use & after changes Medical Device File + Detailed list of items (a-f) that shall be included to meet regulatory requirements Copyright 2015 BSI. All rights reserved. 17

5 Management Responsibility 5 General requirements 5.5.1 Responsibility & Authority 5.5.2 Management representative 5.6 Management review + Regulatory requirements (throughout) Top mgmt shall DOCUMENT the interrelation of all personnel who... Focus on documentation of the quality management system and the removal of customer requirements from bullet c) Procedures required, document planned intervals + More bullet points for inputs, new bullet for outputs Copyright 2015 BSI. All rights reserved. 18

6 Resource Management 6.2 Human resources 6.2 Human resources 6.3 Infrastructure Shall document the processes for establishing competence, providing training, and ensuring awareness + Maintain competency + NOTE effectiveness methodology link to risk of work for which training provided + Prevent product mix up, ensure orderly handling; Maintenance of equipment applies to production, control of work env, monitor and measurement. Copyright 2015 BSI. All rights reserved. 19

6.4 Work environment and contamination control 6.4.1 Work environment 6.4.2 Contamination control Additional reference - + NOTE For information see for example ISO 14644 and ISO 14698 series. For sterile medical devices, the organization shall document requirements for control of contamination with microorganisms or particulate matter and maintain the required cleanliness during assembly or packaging processes. Copyright 2015 BSI. All rights reserved. 20

7 Product Realization 7.1 Planning of product realization 7.2.1 Determination of product requirements 7.2.2 Review of product requirements 7.2.3 Communication + Documented processes for risk management + Required planning for verification, validation, monitoring, measurement, inspection, test activities, handling, storage, distribution, & traceability + Any user training needed to ensure specified performance and safe use of the product + applicable regulatory requirements are met + any user training identified in accordance with 7.2.1 is available or planned to be available The organization shall communicate with regulatory authorities in accordance with applicable regulatory requirements Copyright 2015 BSI. All rights reserved. 21

7 Product Realization (continued) 7.3.2 Design & development planning 7.3.3-5 D & D Inputs, outputs, review 7.3.6 & 7 Design & development V/V 7.3.6 & 7 Design & development V/V List of items to document: + Traceability of outputs to inputs + Competence Inputs + Usability and the ability to verify/validate Outputs + Shall be in a form suitable for verification against inputs Review + Record requirements Requirement to document: the V/V plan, the methods of V/V, criteria for acceptance, rationale for sample sizes. Connections and interfaces V/V of device interfaces. All validation activity must be conducted on representative product or documented equivalent devices Copyright 2015 BSI. All rights reserved. 22

7 Product Realization (continued) 7.3.8 Design & development transfer 7.3.9 Design and development changes 7.3.10 Design and development files New Clause Procedures required Was 7.3.7 Includes greater detail regarding the control of changes, risk management New Clause + Shall maintain a D&D file for each medical device type or family. This file shall include or reference records generated to demonstrate conformity to the requirements for D&D and records for D&D changes Copyright 2015 BSI. All rights reserved. 23

7 Product Realization (continued) 7.4.1 Purchasing 7.4.2 Purchasing information 7.4.3 Verification of purchased product Criteria for evaluation and selection of suppliers includes performance and risk. Supplier performance monitoring as part of re-evaluation process + Purchasing information to include, as applicable product specifications. Suppliers to agree to prior notification of changes + Extent of verification based on risk/supplier evaluation and link to change control Copyright 2015 BSI. All rights reserved. 24

7 Product Realization (continued) 7.5.1 Control of production & service provision 7.5.2 Cleanliness & contamination control 7.5.3 Installation activities 7.5.4 Servicing activities Production and service provisions must be monitored and controlled as well as planned and carried out to ensure product conforms to specifications Similar to 2003 requirements Similar to 2003 requirements Servicing activity records must be analyzed to determine of the issue is a complaint or must be utilized as an improvement input Copyright 2015 BSI. All rights reserved. 25

7 Product Realization (continued) 7.5.6 Validation of processes for production and service provision 7.5.8 Identification 7.5.7 Validation of sterilization and sterile barriers + Validate processes for production & service provision where output cannot be or is not verified + Use appropriate statistical techniques and rationale for sample sizes, approval of changes, and validation of software after any changes, risk based + UDI where required by national or regional regulations + Requirement for procedures for separation of returned products from conforming product + Documented procedures required for validation of sterilization and sterile barriers + Validation required prior to implementation + Document results and conclusion Copyright 2015 BSI. All rights reserved. 26

7 Product Realization (continued) 7.5.9 Traceability 7.5.10 Customer property 7.5.11 Preservation of product 7.6 Control of monitoring and measuring equipment Similar to 2003 version Consistent with 7.5.4 of current document Specific reference to packaging and shipping containers + Distribution is specified Requirements for the validation of the application of computer software used for monitoring and measurement requirements are now within this clause. Risk based approach required. Copyright 2015 BSI. All rights reserved. 27

8 Measurement, Analysis and Improvement 8.2 Monitoring and measurement 8.2.2 and 8.2.3 Complaint handling & Reporting to regulatory authorities New Clauses + Feedback procedures, input to risk management and improvement process. Clause strengthened. Requires procedures for timely complaint handling, investigation, regulatory notification and more Procedures for reporting to regulatory authorities regarding complaints are required Copyright 2015 BSI. All rights reserved. 28

8 Measurement, Analysis and Improvement 8.2.6 Monitoring and measurement of product + Test equipment shall be identified as appropriate 8.3 Control of non conforming product + NC product shall be considered for corrective action following investigation (or documented justification for lack of investigation) + 8.3.1-4 New clauses for nonconforming product before delivery, after delivery and rework 8.5.2 & 8.5.3 Corrective & Preventive action Verifying that the corrective or preventive action does not adversely affect the ability to meet applicable regulatory requirements or the safety and performance of product Copyright 2015 BSI. All rights reserved. 29

Areas of Increased Emphasis Validation, Verification & Design Risk Transfer Management Outsourced Processes & Supplier Control Feedback ISO 13485 3 rd Edition Regulatory Requirements Improved linkage of clauses Copyright 2015 BSI. All rights reserved. 30

ISO 13485:2016 Annexes Annex A Comparison of content between ISO 13485:2003 and ISO 13485:2016 Annex B Comparison of content between ISO 13485:2016 and ISO 9001 9001:2015 European Annexes ZA (AIMD), ZB (MDD) and ZC (IVD) Identifies relationship between the European Standard (EN ISO 13485:2016?) and Conformity Assessment Requirements of the respective EU Medical Device Directives via each conformity assessment route for each directive Copyright 2015 BSI. All rights reserved. 31

Potential Timings Copyright 2015 BSI. All rights reserved. 32

EN ISO 13485:2016 Possible Timings 29 October 2015 FDIS Published for 2 month vote under the Vienna Agreement Straight Yes / No Vote with no technical comments permitted 29 December 2015 End of 2 month vote period If positive vote outcome proceeds to publication March 2016 ISO 13485:2016 published with 3 year transition period No new ISO 13485:2003 certificates in final year of transition March June 2016 European Harmonization? EN ISO 13485:2016?? March June 2019 End of 3 year transition Copyright 2015 BSI. All rights reserved. Compiled Paul Sim - Issue 1 - January 2015 33

Global Picture ISO 9001 and ISO 13485 Revisions MDSAP Pilot - US, Canada, Brazil, Australia (& in 2016 Japan with Europe watching carefully) Japanese Requirement (JPMD Act) New MDR / IVDR Copyright 2015 BSI. All rights reserved. 34

Thank you Name: Title: Address: Stewart Brain QMS Certification Lead Medical Devices BSI, Kitemark Court, Davy Avenue, Knowlhill, Milton Keynes MK5 8PP, UK Mobile: +44 (0)7768 387325 Email: Links: stewart.brain@bsigroup.com http://medicaldevices.bsigroup.com/ Copyright 2015 BSI. All rights reserved. 35