An Examination of the OITC Metric for Building Facade Design in New York City

Similar documents
The Role of Acoustics in Curtain Wall Design:

Retrofit structural insulated panels (SIPs) increase sound transmission loss of existing single family houses impacted by highway noise

VIII. Noise A. INTRODUCTION B. BACKGROUND

Noise impact assessment of mass rapid transit systems in Delhi city

Acoustical Guide Table of Contents

SOUND TRANSMISSION CLASS TEST REPORT Series/Model: T-DR1 Teutonic Outswing Vinyl Entrance Door

SOUND TRANSMISSION CLASS TEST REPORT Series/Model: T-DR2 Teutonic Outswing Vinyl Entrance Door

Lightweight Partition Design for Residential and Commercial Buildings

E R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E90. Rendered to: TREX COMPANY, LLC. Series/Model: Trex Seclusion

Mass Loaded Vinyl A review of the performance and cost in acoustical applications

Acoustic expectations, health effects, and design techniques in the urban environment

SOUND TRANSMISSION CLASS TEST REPORT Series/Model: VL-WDW11 VistaLuxe Awning

Acoustical Doorway Solutions

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: TUBELITE, INC. SERIES/MODEL: T TYPE: Two-Lite Storefront

Acoustic Terms, Definitions and General Information

ASTM E 90: Laboratory Measurement of Airborne Sound Transmission of Building Partitions and Elements

Building Design for Advanced Technology Instruments Sensitive to Acoustical Noise

Difference in levels of groundborne noise and vibrations between the T-1300 and MX-3000 metro trains in Oslo

Build Green Schools. Click on this link for more information.

INC Flexi-Sorb. Versatile Flexible Easy To Install Durable Good Noise Reduction Economical. Typical Applications

LEED Pilot Credit Library

An Experimental Study of the Sound Insulation Performance and Sound Defect Using Sound Intensity According to the Composition of Balcony Windows

A GUIDE TO NEW YORK CITY REGIONAL TRANSPORTATION

VIPAC ENGINEERS & SCIENTISTS

Noise associated with the ground water systems serving residential geothermal heat pumps

For Sale - $11,000,000 - Negotiable Excellent User Opportunity -

Acoustic design of schools: performance standards. From 2003 to 2014: a brief guide to the changes in BB 93. by Jack Harvie-Clark, 9th January 2015

BNAM 2008 BERGEN BYBANE NOISE REDUCTION BY TRACK DESIGN. Reykjavik, august Arild Brekke, Brekke & Strand akustikk as, Norway

Fundamentals of Acoustics & Practical HVAC Design Considerations. Demir Doken Acoustic Engineer

Color logos Reverse logos Acoustics Black only logos

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: MGM INDUSTRIES SERIES/MODEL: TYPE: Single Hung Window

WINDOW SOUND PROOFING FOR CONSTRUCTION NOISE AT THE CENTRAL ARTERY/TUNNEL PROJECT

Noise Design Advice. Noise can be a major factor to consider in any new development.

Trans Bay Cable Project (400 MW) Preliminary Audible Noise Study

MEETING MINUTES INDUSTRIAL BUSINESS ZONE (IBZ) BOUNDARY COMMISSION NOVEMBER 21, 2013, 9:00 AM

City of Houston, Texas, Ordinance No

General Thoughts on Generator Set - Acoustic Solutions & Noise Control

GTA Cordon Count Program

As a minimum, the report must include the following sections in the given sequence:

Brookdale Site. CB6 Update April 1, 2015

WHEREAS, on December 20, 2012, Metro Storage NY, LLC submitted an application

Investigation of sound insulation for a Supply Air Window field measurements and occupant response

Nashville Area MPO Regional Freight Study fast action projects

PVC Sound Barrier Wall Systems Lightweight and easy-to-install Lower installed costs

BLOCK 400 PLANNED COMMUNITY DISTRICT

Schindler 3300 / Schindler 5300 Information on noise and vibration.

RANDOM VIBRATION AN OVERVIEW by Barry Controls, Hopkinton, MA

Bandwidth-dependent transformation of noise data from frequency into time domain and vice versa

Exhaust noise control case study for 2800 class locomotive

Affordable Sports Halls

A. Permitted uses. The following uses are permitted by right in the C-2 zone, subject to the limitations specified:

Noise Control Solutions For Standby Power Generators

NOISE STUDY. 9th and Palm Commercial Development Imperial Beach CA. Project Proponent:

KRUGER ENERGY CHATHAM WIND PROJECT ENVIRONMENTAL SCREENING REPORT / ENVIRONMENTAL IMPACT STATEMENT. Appendix E. Environmental Noise Impact Assessment

Traffic Information in NYC

Taxicab and Livery Crashes in New York City 2004

Acoustical Design Guidelines for HVAC Systems in Schools

Minimizing noise levels so future engineers can focus Classroom Acoustic Technical Reference Guide

EXISTING MASONRY WALL TO REMAIN (TYP.). EXISTING PARTITION TO REMAIN PROVIDE 3'-3" W. X 8'-0"H. NEW PELLA WINDOWS AS INDICATED ON PLANS. (TYP.

ACOUSTICS: The Sounds of Sustainable Design

IV. INDUSTRIAL TRACK DESIGN

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

DUBLIN CITY COUNCIL AMBIENT SOUND MONITORING NETWORK Annual Report For 2011

Zoning Guide* Contents. Section I Introduction page 2. Section II Residence Districts page 3. Section III Commercial Districts page 5

The Future of Airport Design.. Sara Beardsley, AIA, LEED AP Senior Architect

Noise: Impact on Hearing; Regulation

Urban noise and required facade acoustic insulation of buildings: the case of some agglomerations in Italy

Acoustics of indoor sports halls and gymnasia

Civil Engineering and Architecture (CEA) Detailed Outline

Enclosures DuraSystems Barriers, Inc. The Passive Fire Protection Specialists

The Preservation of Local Truck Routes: A Primary Connection between Commerce and the Regional Freight Network

INTER-NOISE DECEMBER 2006 HONOLULU, HAWAII, USA

Charlton Christian College, Fassifern Master Plan Acoustic Assessment for the Proposed Facilities Upgrade

Department of State Development, Infrastructure and Planning. State Planning Policy state interest guideline. State transport infrastructure

Evaluation and analysis of traffic noise from the main roads in the Trakya region of Turkey

Casa da Musica, a new concert hall for Porto, Portugal

Radio Frequency (RF) Survey

REQUEST FOR RESPONSE

Chapter 7 NOISE ELEMENT 7.1 INTRODUCTION 7.2 AUTHORITY FOR ELEMENT 7.3 NOISE DEFINITIONS

Airborne Sound Insulation

Characterization of acoustics in open offices - four case studies

3D City Models for Simulation & Training Requirements on Next Generation 3D City Models

Departures to the south from Runways 16L and 16R.

Bergen, Norway BNAM May Modern passenger trains in Norway - are they as quiet as we think?

ACOUSTICAL CHALLENGES IN GREEN BUILDINGS

Controlling the Transmission of Impact Sound through Floors

(3) CATEGORY III means a permanent heliport facility. (4) COMMISSION means the City of Austin Airport Advisory Commission.

Measuring Sound Insulation using Deconvolution Techniques

DEPARTMENT OF TRANSPORT CYCLING STRATEGY 29 February 2008

Saint Cloud Business Center

SOUND INSULATION FOR AIR CONDITIONERS AND OTHER EXTERNAL MECHANICAL PLANT. Installing and Maintaining Air Conditioning Units

Bergen, Norway BNAM May Open versus closed ventilation devices what is the impact on indoor sound pressure levels?

Robert D. Trimborn Airport Director Santa Monica Airport

How To Reduce Noise From A Test Screen

PLANNING POLICY 3.3.5

EAST HARLEM COMMERCIAL RFP PROPOSAL Q&A

Acoustic Design Practices for Sustainable Buildings

ARTICLE 13 B-3 BUSINESS DISTRICT

Downtown Vancouver Full Block For Sale 1.03 Acre Redevelopment Opportunity

Leading the way in Quiet Zone Solutions. Implementing Quiet Zones to Address Train Horn Noise

Transcription:

Portland, Oregon NOISE-CON 2011 2011 July 25-27 An Examination of the OITC Metric for Building Facade Design in New York City Benjamin H. Sachwald a) Christian P. H. Thompson b) AKRF, Inc. 440 Park Avenue South 7th Floor New York, NY 10016 The Department of City Planning in New York issued an updated City Environmental Quality Review (CEQR) Technical Manual in May of 2010. While most City Agencies have gradually made the transition from the STC metric to the OITC metric for building façade design evaluation, Chapter 19, Noise of the 2010 CEQR Technical Manual represents the first time this design requirement has been officially prescribed. While most acoustical consultants will typically perform 1/3 octave band transmission loss calculations based on site-specific noise survey data and the ASTM E90 laboratory test data of façade elements, having a simplified single number metric, such as OITC, provides City Agencies (ex: DOB, OER, DEP, etc.) the ability to certify compliance in an expeditious manner. While OITC is arguably the most appropriate single number metric for building façade design, this paper explores the intricacies associated with using the OITC metric in New York City. Specifically, using actual noise survey data of roadway, railway, and aircraft activity for specific development sites, interior noise levels were calculated and compared using two approaches: 1) the OITC metric, and 2) 1/3 octave band transmission loss calculations. 1 INTRODUCTION In the New York City urban environment, noise pollution comes from a wide variety of sources: vehicular traffic (autos, trucks, busses), commuter rail and above-ground subway lines, aircraft (rotorcraft and fixed-wing), and stationary sources such as manufacturing and industrial facilities. Some sources are activities essential to the health, safety, and welfare of a city s inhabitants (e.g., noise from emergency vehicle sirens, garbage collection operations, construction and maintenance equipment). Other sources, such as vehicular, rail and aircraft traffic, are essential to the viability of a city as a place to live and do business. Although these and other noise-producing activities are necessary to a city, the noise they produce is undesirable. New York City s high population density and wide variety of land uses (e.g. residential, commercial, transportation, manufacturing and industrial) exist in close proximity and it is common for a noise-sensitive building (i.e., residential, school, hospital, high-end office space, etc.) to be located in an area with ambient noise levels considered undesirable for development. Since developers have no control of environmental noise sources, such as an elevated subway a) Email: bsachwald@akrf.com b) Email: cthompson@akrf.com

adjacent to a development site, in order to avoid a finished building with interior noise levels unsuitable for tenant use, a proposed development s façade should be designed and constructed to adequately block the intrusion of exterior environmental noise. Accordingly, the City of New York prescribes minimum window/wall attenuation requirements for projects: 1) requiring discretionary approvals, 2) on a tax Block/Lot with an (E) designation or Restrictive Declaration, or 3) in a Special Mixed Use District. To demonstrate compliance with the City s minimum window/wall attenuation requirement, the single number Outdoor Indoor Transmission Class 1 (OITC) metric is used. While most acoustical consultants typically perform 1/3 octave band transmission loss calculations based on site-specific noise survey data and the ASTM E90 2 laboratory test data of façade elements, having a simplified single number metric, such as OITC, provides City Agencies (ex: Department of Buildings [DOB], Office of Environmental Remediation [OER], Department of Environmental Protection [DEP], etc.) the ability to certify compliance in an expeditious manner. While OITC is arguably the most appropriate single number metric for building façade design, this paper explores the intricacies associated with using the OITC metric in New York City. 2 2010 CEQR ATTENUATION REQUIREMENTS In May of 2010, the Mayor s Office of Environmental Coordination released an updated City Environmental Quality Review (CEQR) Technical Manual (previous CEQR Technical Manual update was October 2001). The CEQR Technical Manual defines minimum attenuation requirements for buildings based on exterior noise level (see Table 1). The minimum noise attenuation values for buildings are designed to maintain interior noise levels of 45 dba (approx. NC 40) or lower for residential, school, hospital, etc. uses and interior noise levels of 50 dba (approx. NC 45) or lower for office, retail, etc. uses and are most often determined based on exterior L 10 c noise levels. These interior noise level design goals account for the intrusion of exterior environmental noise (i.e., roadway, railway, aircraft, etc.) only (i.e., independent of building mechanical, plumbing, etc. systems). When comparing the 2010 publication to the 2001 publication of the CEQR Technical Manual, the two most significant revisions are as follows: While the CEQR interior noise level criteria [i.e., 45 or 50 db(a) L 10 or less, depending on use] have not changed, the 2010 CEQR Technical Manual s noise attenuation requirement increments are smaller [1 to 3 db(a)] compared to those in the 2001 CEQR Technical Manual [5 db(a)], and While most City Agencies have gradually made the transition from the STC metric to the OITC metric for building façade design evaluation prior to its release, the 2010 CEQR Technical Manual represents the first time this design requirement has been officially prescribed. 3 NEW YORK CITY - COMMON ENVIRONMENTAL NOISE SOURCES As previously discussed, the noise pollution in New York City is a result of a wide variety of sources: vehicular, rail and aircraft traffic; manufacturing and industrial uses; outdoor mechanical equipment; business and commercial uses, nightclubs, etc. The New York City c Depending on site-specific conditions, the daily L dn (for rail) and yearly L dn (for aircraft) must be examined in lieu of the peak hour L 10 value for noise attenuation requirements.

Zoning Resolution Performance Standards for Manufacturing Districts prescribes noise limits for areas zoned manufacturing and the New York City Noise Control Code sets stringent limits on specific noise sources such as outdoor mechanical equipment, business and commercial uses, and amplified music associated with nightclubs, etc. Consequently, this study focuses on the environmental noise sources discussed below that are not regulated by City codes. 3.1 Roadway The following common roadway categories that occur in New York City and their associated characteristics are outlined below. At-Grade, Elevated and In-Cut Highways: large volume of vehicles that can include a high volume of trucks (ex: Brooklyn Queens Expressway), traffic traveling at speeds in excess of 35 miles per hour (MPH), and little-to-no stop lights or other traffic control measures. Examples include the Bruckner Expressway, Long Island Expressway, and Franklin D. Roosevelt Drive. Major Avenues/Streets: large volume of vehicles that can include a high volume of trucks and/or busses, traffic traveling at speeds of 35 MPH or less, stop lights or other traffic control measures at each intersection. Examples include Second Avenue, East 34th Street, and Flatbush Avenue. Minor Streets: moderate to low volume of vehicles with typically little-to-no trucks or busses, traffic traveling at speeds of 35 MPH or less, stop lights or other traffic control measures at each intersection, and some locations with irregular roadway surfaces such as cobblestone (ex: Water Street in Brooklyn). Examples include East 2nd Street, Bedford Street, and Sterling Place. Bridges: large volume of vehicles that can include a high volume of trucks (ex: George Washington Bridge), traffic traveling at speeds in excess of 35 MPH, and little-to-no stop lights or other traffic control measures. Examples include the Brooklyn Bridge, Robert F. Kennedy Bridge, and Ed Koch Queensboro Bridge. 3.2 Railway The following common railway categories that occur in New York City and their associated characteristics are discussed below. Elevated Rail: while there are locations in Manhattan with elevated rail (ex: 1 and A Trains, Metro North Railroad) these are more common in outer boroughs (i.e., Brooklyn, Queens and the Bronx), elevated subway trains (i.e., electric, local [more frequent stops] and express [less frequent stops], typically slower speeds than commuter trains) and commuter trains (i.e., electric, fewer stops, wide range in speed). A significant source of non-vehicle noise is a result of structure-borne noise caused by the metal railway structures and wheel-to-rail curvesqueal at curve locations. Examples include F, B and 3 Trains. At-Grade Rail: typically electric commuter trains, fewer stops, and wide range in speed. Examples include the Long Island Rail Road. In-Cut Rail: less common, subway (i.e., electric, local [more frequent stops] and express [less frequent stops] trains) with typically slower speeds than commuter trains, and regional rail. Examples include the Q train and AMTRAK.

3.3 Aircraft The two common aircraft categories that occur in New York City and their associated characteristics are discussed below. Fixed-Wing: Aircraft take-offs, landings, and flyovers associated with John F. Kennedy, LaGuardia, and Newark Airports. Rotorcraft: Helicopter idling, hovering, take-offs, landings, and flyovers associated with hospitals, City of New York Police Department, East 34th Street Heliport, etc. 4 METHODOLOGY To examine potential caveats associated with using the OITC metric in New York City, an investigation was performed in accordance with the methodology outlined below. Actual noise survey data for specific development sites was assembled and divided into categories (i.e., roadway, railway, and aircraft) based on the dominant source of noise. The 1/3 octave band L 10 values (in db) and broadband L 10 values (in dba) for each measurement were collected. The spectral shape of the measured L 10 1/3 octave band values were compared to the spectral shape of the ASTM E1332-10a reference spectrum and any significant differences were noted. To minimize the number of variables in the investigation, the theoretical building façade was assumed to be a 1-inch insulated glass unit (IGU) of ¼ glass ½ airspace ¼ glass. From our experience, this glass assembly is very typical for windows, window/wall systems, and curtain walls of new development projects in New York City. This IGU has been tested at several NVLAP certified acoustical test facilities and has an OITC rating of 30. Interior noise levels, due to the intrusion of exterior environmental noise, were calculated and compared using two approaches: 1) measured broadband L 10 value (in dba) minus the OITC metric, and 2) measured 1/3 octave band L 10 values (in db) minus the ASTM E90 1/3 octave band transmission loss values. The results of the investigation are presented below. 5 INVESTIGATION RESULTS This section discusses and compares the results of the investigation between using the OITC metric and 1/3 octave band analysis to predict interior noise levels based on the intrusion of exterior environmental noise. The difference between the two calculation approaches was recorded and a standard deviation was found for each noise source category (i.e., roadway, railway, and aircraft). Unless the difference was within one standard deviation, when the measured broadband L 10 value (in dba) minus the OITC metric method resulted in a lower interior noise level than the measured 1/3 octave band L 10 values (in db) minus the ASTM E90 1/3 octave band transmission loss values method, the spectral shape of the measured L 10 1/3 octave band values were compared to the spectral shape of the ASTM E1332-10a reference spectrum and any significant differences were noted.

The delta between using the OITC metric versus a 1/3 octave band analysis was determined. If use of the OITC metric resulted in a higher predicted interior noise level (when compared to the predicted interior noise level using the 1/3 octave band analysis), the delta was a positive number; if use of the OITC metric resulted in a lower predicted interior noise level (when compared to the predicted interior noise level using the 1/3 octave band analysis), the delta was a negative number (and if the OITC metric and 1/3 octave band analysis resulted in the same predicted interior noise level, the delta was zero). Since the CEQR Technical Manual uses the OITC metric (and subsequently, this is what New York City Agencies such as DOB, OER, DEP, etc. enforce), a delta greater than zero indicates that use of the OITC metric would be conservative and result in adequate interior noise levels when used for building façade design acoustical specifications. If the delta was a negative number, this indicates that use of the OITC metric is likely to result in interior noise levels greater than what was predicted by subtracting the OITC rating from the measured L 10 value in dba (and consequently, use of the OITC metric for building façade design acoustical specifications should be used with caution). The results of the investigation are shown in Table 2. A summary is as follows: Use of the OITC metric was conservative for 208 of the 248 (i.e., 83.8%) cases examined for this investigation. For 37 of the 248 (i.e., 14.9%) cases examined, use of the OITC metric resulted in interior noise levels lower than what was calculated using the 1/3 octave band method. For 3 of the 248 (i.e., 1.2%) cases examined, the OITC metric and 1/3 octave band method predicted identical interior noise levels The standard deviation was determined for each noise source category: ±1.54, ±1.76, and ±1.38 for roadway, railway, and aircraft, respectively. All noise survey data was divided into their respective categories based on dominant noise source (i.e., roadway, railway, and aircraft) and plotted against their respective standard deviations (see Figures 1, 2 and 3). Several data points with a negative delta fit inside of these standard deviations. When excluding these values within one standard deviation, only 13 of the 248 (i.e., 5.2%) cases examined remained. For data points with a negative delta, the spectral shape of the OITC reference spectrum was compared to that of the site-specific noise survey data. Whether it was a mid-spectrum peak associated with wheel-to-rail curve-squeal, high levels of low frequency (i.e., below 125 Hz) noise associated with heavy truck and bus traffic, or locations not immediately adjacent to a busy roadway (or other noise source[s]), in these cases it was apparent that the measured spectrum shape notably deviated from the OITC reference spectrum (see Figure 4 for an example). 6 CONCLUSIONS While the most accurate method to predict interior noise levels due to the intrusion of exterior environmental noise is to perform 1/3 octave band transmission loss calculations based on sitespecific noise survey data and ASTM E90 laboratory test data of façade elements, building codes and city regulations are commonly based on single number metrics (such as OITC). As this investigation demonstrates, developing a building façade design acoustical specification based on the OITC metric in New York City is a conservative approach for more than 80% of the cases examined. Considering the number of variables involved and the investigation s standard deviations, use of the OITC metric in New York City was determined to be a successful approach for approximately 95% of the cases examined. Despite this rate of success, it is strongly recommended to always compare a noise survey s measured 1/3 octave band spectral

shape to that of the OITC reference spectrum to determine any notable deviations. If notable deviations between these two spectra are identified, 1/3 octave band calculations are recommended. Since the DOB, OER, and DEP use the OITC metric to certify compliance, the results of 1/3 octave band calculations can be used to make necessary adjustments to the project specifications such that both the City Agencies and the project interior noise level criteria are achieved. 7 REFERENCES 1. ASTM E1332-10a, Standard Classification for Rating Outdoor-Indoor Sound Attenuation 2. ASTM E90-09, Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements Table 1 May 2010 CEQR Attenuation Requirements Peak Hour Noise Level in db(a) Attenuation 70 < L 10 73 28 db(a) 73 < L 10 76 31 db(a) 76 < L 10 78 33 db(a) 78 < L 10 80 35 db(a) 80 < L 10 36 + (L 10 80) db(a) Noise Source Category Number of Instances where 1/3 Octave Band TL Resulted in Lower Interior Noise Level Table 2 Summary of Investigation Results Number of Instances where OITC Resulted in Lower Interior Noise Level Range of Differences Between Two Methods, in db(a) Standard Deviation Roadway 171 28 ±1.54-3.5 to 5.1 Railway 19 5 ±1.76-2.6 to 2.9 Aircraft 18 4 ±1.38-1.8 to 3.1

Fig. 1 Roadway Traffic Comparison Fig. 2 Railway Traffic Comparison

Fig. 3 Aircraft Traffic Comparison Fig. 4 Measured vs. OITC Reference Spectrum