SOURCE HOLDERS FOR RADIATION-BASED MEASUREMENT SOLUTIONS

Similar documents
VEGAPULS PULSE RADAR FOR LEVEL MEASUREMENT VEGAPULS 60 SERIES

RADIATION MONITORING SYSTEMS

Emergency Power System Services Industrial UPS, Batteries, Chargers, Inverters and Static Switches

Ch. 227 ANALYTICAL X-RAY EQUIPMENT 25

MATERIALS LICENSE. 1. Honeywell International, Inc. 3. License Number: SUB-526, Amendment 6-1

MATERIALS LICENSE. Delaware City, Delaware Docket No Reference No.

Darchem Thermal Protection

Non-Destructive Testing

The Unique Accelabar Flow Meter

WEKO-SEAL Internal Joint Sealing WEKO-SEAL. internal pipe-joint sealing

GUIDE FOR THE PREPARATION OF RADIOACTIVE MATERIAL APPLICATIONS FOR WELL LOGGING OPERATIONS IN KENTUCKY

Measurement & Analytics. VIS Multiphase Flow Meter High gas content applications solved with no radioactive source - Measurement made easy

Wind Direction Smart Sensor (S-WDA-M003)

Automatic Fire Fighting Monitors

Toroidal Conductivity Sensor

Application Note. ipix A Gamma imager to support various applications

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Technical Electrical Field Service Support. Knowledge + Experience = Power. Field Service

In-Line Electronic Flow Switches

Light Duty Commercial Electric Water Heater

ENGLISH FORK GUIDE 2013

RODADEACO. Diesel Engine Air Intake Shutoff Valves. Model RDS1 Swing Gate Valve. by AMOT. Overview. Typical Applications. Key Features and Benefits

Electronic Flow Switches

RUBBER SLEEVE KNIFE GATE VALVE

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

PBM has solutions for your valve application.

GE Oil & Gas. Texsteam * Pumps: precise chemical injection pumping

The Piping System Model a New Life Cycle Document. Elements of the Piping System Model

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

Pr oduct Overview Product Overview SMC Pneumatics BV

Integrated Custom Systems

PART 1 - INTRODUCTION...

CEILING CASSETTE FAN COIL UNIT

RGC-IR Remote Gas Calibrator for IR400

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

JOINT INTEGRITY MANAGEMENT SOLUTIONS

Compact pressure switch Flameproof enclosure Ex d Model PCA

Our Know-How. Your Peace of Mind. Innovative Sealing and Gasket Solutions

Working Safely With Nuclear Gauges

MaraMeter. Indicating Snap Gages

Whitepaper Modular Integration of Process Equipment Packages for Oil and Gas Facilities

How To Make A Pressure Relief Valve

Interface Level And Point Level Analyzers & Sensors

Pipe Cutting and Beveling Clamshells

ABEL Positive Displacement Pumps

Reliability Accuracy Performance

Scepter PVC Molded Junction Boxes

D. Infrared scanning reports with pictures printed in a final report with any deficiencies and actions taken to rectify.

Assured Joint Integrity

Turbine Flow Sensor Series VTR

SECTION ( ) FIRE DETECTION AND ALARM SYSTEM

HSE information sheet Industrial radiography - managing radiation risks Ionising Radiation Protection Series No. 1(rev 1)

Waterstops play a critical role in the integrity of concrete

Radiation Strip Thickness Measurement Systems

Fig. 2 Option 1 Integrated Design using Physical Separation. Fig. 1 Standard Modular Process Skid Design Concept

Series 510 Submersible Level Transmitters

Hygro-Thermometer + InfraRed Thermometer Model RH101

Maintenance in instrumentation Maintenance with concept and technology focusing on results

Daniel Venturi Tubes and Flow Nozzles Brochure

BULLETIN OCTOBER DeZURIK ROTARY DIAPHRAGM ACTUATORS

Models SFP33 & SFP32 Pressure Transmitters

Bulk Flow Meter LB 442 P R O C E S S C O N T R O L

Installation Instructions Hustler 6-BTV Trap Vertical

FTXS. Wall Mount Heat Pump or Cooling Only

ENERGY HYDRO POWER SOLUTIONS FOR ELECTRICAL POWER TRANSFER ELECTRICAL PROTECTION SEALING

Enhanced calibration High quality services from your global instrumentation partner

Fire Pump Plan Review March 2010

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

LABORATORY SAFETY INSPECTION CHECKLIST

Questionnaire for NORM service providers

PART H RADIATION SAFETY REQUIREMENTS FOR ANALYTICAL X-RAY EQUIPMENT. Definitions. As used in this Part, the following definitions apply:

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

WILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP

DOCUMENTATION FOR QUALIFICATION SYSTEM

Salof Companies Modularized Gas Liquefaction Plants

FIRE ALARM SYSTEM. reliable fire detection and alarm signalling system

Tank Gauging & Inventory Management Solutions

Electrical Solutions for Motors & Generators

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap

valve solutions Chemical Cosmetic Cryogenic Food & Beverage Marine Mining Nuclear Oil & Gas Paint Pharmaceutical Pulp & Paper

FilterFlow Automatic Water Boilers. Pure Quality

ENAiKOON ultrasonic fuel-level sensor

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

Solar Power Systems Models: PVS220W-24 and PVS220W-48 Installation Manual

SafePoint RMS. Sustainable Committed Secure. SafePoint. Monitoring Solutions

SFI SPECIFICATION 61.1 EFFECTIVE: FEBRUARY 26, 2014

PSAC/SAIT Well Testing Training Program Learning Outcomes/Objectives Level D

BaseCal 3. BaseCal, the web-based performance calculation tool for Diaphragm Seals

8146/5 Series Breaker Panelboards

Easily installed and simple to set up, Flow Pulse uses an acoustic technique never before seen in flow measurement to deliver reliable results across

SECTION 6 SANITARY SEWER MAIN 6.01 SCOPE

Pipe and cable fastening with plastic pipe clamps

RAUFOSS EXPLOSIVE COMPRESSION FITTINGS

Guardian Telecom Systems. Telephone.

Everything you need for protection scheme testing

Aftermarket Technical Service Solutions for Pumping Technologies

Transcription:

SOURCE HOLDERS FOR RADIATION-BASED MEASUREMENT SOLUTIONS

Why use RADIATION-BASED MEASUREMENT? Radiation-based measurement is a proven technology with thousands of installed applications Unlike most other level and density technologies, nuclear gauges avoid contact with process conditions Processes with extreme temperature, pressure, or corrosive properties have no adverse effects on nuclear gauges Radiation-based technology can be installed with no process shutdown and generally requires no modification to existing vessels or piping, reducing total installation cost INDUSTRIES Radiation-based systems can be applied in virtually any industry Ohmart/VEGA excels at radiation-based measurement in industries such as: Offshore Petrochemical Water and Wastewater Pulp and Paper Plastics Power Food and Beverage Cement Asphalt Chemical Mining And many more!

4 :: SOURCE HOLDERS :: Nuclear EXPERTISE Ohmart/VEGA is a world leader in radiationbased measurement solutions, offering the most complete line of source holders in the industry Whether your application is level, density, weight, or point level, Ohmart/VEGA has a source holder to meet your needs For over fifty years, Ohmart/VEGA employees have been assisting customers with radiological concerns We work closely with each client every step of the way: from specification through startup and operation all the way to disposal No supplier provides more assistance than Ohmart/VEGA INDUSTRY APPROVALS All sources distributed by Ohmart/VEGA are designed to meet worldwide industry approvals, including ANSI and ISO standards Sources are registered with either the ODH (Ohio Department of Health) and Agreement State or the CNSC (Canadian Nuclear Safety Commission) Other registrations are available upon request Many of our source holders are available with a General License (USA only and application specific) This reduces licensing paper work and radiation safety program requirements

Models & VERSIONS Gamma source placement and alignment is critical to measurement accuracy Properly protecting and shielding the source assures the health and safety of your employees Ohmart/VEGA's large selection of source holders allows our Application Engineers to specify appropriate and cost effective solutions to your measurement needs SHGL Many applications require a small source The SHGL low level radiation source holder is the answer to those applications Roughly the size of a 12 ounce soft drink can, the SHGL offers a light weight, low profile solution without requiring a Specific License (USA only) The SHGL requires no shutter checks or factory start-ups SR The SR series is designed to provide a safe source housing at a reasonable cost This series of source holders is a perfect fit for point level and density applications where a fireproof design is not required The SR has a time tested design and is available in low carbon, 304 and 316 stainless steels

6 :: SOURCE HOLDERS :: Models & VERSIONS Continued SHLD The SHLD combines a rugged cast steel housing with proven lead shielding to provide compact and cost effective source protection The SHLD is designed to be smaller and lighter weight than typical source holders while providing certified protection This allows for easier shipping, installation, and use SHF Ohmart/VEGA's SHF series is the industry's first lead-free fireproof design Constructed from rugged cast iron and tungsten, this popular model meets the needs of explosive or flammable environments such as refineries and chemical manufacturing plants SHLG Designed to house high-activity sources, the SHLG Series of source holders can be used in both level and point level applications The rugged SHLG is available in low carbon, 304 and 316 stainless steels SHLM The SHLM is used for critical high pressure applications when vessel walls are too thick for conventional sources The SHLM utilizes a rod or cable activator to place a source inside the vessel via dry well This holder may be used for density, level, and interface applications

ACCESSORIES INTERLOCK Used to prevent vessel access while source holder shutter is open, our range of interlock accessories can be mounted to any source holder with a moveable shutter SHUTTER ACTUATOR Air or electric activation is available to remotely open/close a source holder's shutter A visible indicator is provided for verification CAPTIVE LOCK & LANYARD The captive lock can be permanently attached to the source holder ensuring the combination lock will always remain at the source holder SHUTTER MICRO LIMIT SWITCH Used to provide an electric on/off signal based on the position of a source holder's shutter, limit switches are available in general purpose and explosion proof designs REFERENCE ABSORBER Primarily used with a clamp-on density system, the reference absorber provides the ability to check detector calibration by simulating a previously established process condition DENSITY PIPE BRACKETS Available in clamp-on, large pipe, and 30 angle configurations Density pipe brackets provide proper and easy mounting for any density system Standard bolt patterns allow for use with a wide variety of source holders and accessories

8 :: SOURCE HOLDERS :: Nuclear SERVICES Ohmart/VEGA is able to meet all of your radiation service needs Our Field Service staff provides unsurpassed expertise in fulfilling mandated radiological surveys and inspections These same technicians also perform start-up, calibration, and on-site training services With 24-hour emergency service phone support, service personnel located worldwide, and a full production service facility, Ohmart/VEGA is always ready to provide the following: LOGISTICS Transporting radioactive material can be complicated Ohmart/VEGA has assisted customers from every part of the world with logistics Our own freight forwarders are well experienced with shipping nuclear gauges For customers who prefer their own forwarders, our Order Management staff assists with documentation and recommendations LICENSING Ohmart/VEGA's dedicated Licensing staff works with each client to verify requirements are met In cases where new licenses or modifications are required, we assist in this process by providing documentation and making recommendations Our decades of experience and intimate knowledge of NRC, State, and international regulations streamlines this important process

START-UP AND COMMISSIONING SERVICE Top quality start-up service ensures proper functioning of the gauge with all safety and compliance issues fully addressed Our service personnel inspect the mounting of the equipment, perform leak checks and shutter checks, and document the radiation levels around the equipment The detector is also checked for functionality and is calibrated to the customer's process RADIATION SAFETY AND PRODUCT TRAINING Ohmart/VEGA offers comprehensive training programs for radiation safety and system operations Classes include: Radiation safety awareness classes (on-site) NRC-recognized 40 hour Radiation Safety Officer certification training Radiation Safety Officer recertification training Gauge setup, calibration and operation training (on-site) LEAK TEST MANAGEMENT Periodic wipe tests are required on the source holder to ensure that no radioactive material has leaked Ohmart/VEGA provides this service plus licensed technical analysis with certificate on all leak tests RADIATION SAFETY PROGRAM AUDITING Radiation safety programs may be audited by government agencies to verify compliance Ohmart/VEGA's auditing service proactively verifies that programs match their license requirements and permissions METER CALIBRATION Maintaining survey meter calibration is an important part of any radiation safety program Ohmart/VEGA calibration service includes an annual 30-day reminder letter and calibration certificate Meter calibration can performed on most beta/gamma radiation meters DISPOSAL Disposing of radioactive material after service life is a primary concern for most customers Ohmart/VEGA provides complete disposal services for most Cesium 137 or Cobalt 60 sources, including sources from other manufacturers

10 :: SOURCE HOLDERS :: Source Holders AT A GLANCE Source Holder Model SHGL SR SHLD SHF SHLG SHLM APPLICATIONS Continuous Level Point Level Density Weight Interface SPECIFICATIONS Maximum Cs-137 Activity for 5 mr/hr @ 12 inches Maximum Cs-137 Activity for 025 mr/hr @ 1 meter Fire Resistance Shielding Material 2 mci 5,000 mci 10,000 mci 1,600 mci 10,000 mci Consult (074 GBq) (185 GBq) (370 GBq) (74 GBq) (370 GBq) Factory 2 mci 100 mci 10,000 mci 600 mci 10,000 mci Consult (074 GBq) (59 GBq) (370 GBq) (222 GBq) (370 GBq) Factory 800 C / 20 min 538 C / 5 min 800 C /30 min 800 C /30 min 538 C / 5 min 538 C / 5 min Stainless Steel Lead Lead Iron/Tungsten Lead Lead

Ohmart/VEGA Radiation-based Measurement SYSTEMS Ohmart/VEGA's experienced Engineering staff reviews each measurement application to develop cost effective and radiologicallyresponsible solutions Our complete line of source holders and detectors optimizes system design for the following applications: CONTINUOUS AND POINT LEVEL Continuous and point level systems can use virtually any source holder 45 collimation is common for continuous level measurement and can be based on an external or insertion style source 0 collimation is standard for point level, or a switch can be added to an existing system and use the continuous level source DENSITY Typically a clamp on system to a vertical pipe, density systems can use a wide variety of source holders including the SHGL low activity holder INTERFACE The SmartScan profiler uses an integral source that is contained within the "leg" of the unit The source is raised and lowered by a motor-driven tape to provide full vessel scanning WEIGHT The W4800 weigh scale utilizes a low activity SHGL source which allows for a general license (USA only), saving cost on installation and service Also available with the SHF source holder

4170 Rosslyn Drive Cincinnati, Ohio 45209 toll free: 1800FORLEVEL telephone: 5132720131 fax: 5132720133 web: wwwohmartvegacom email: info@ohmartvegacom 32867-US-071207