Deploying OCP Hardware in a Collocated Facility



Similar documents
Server Chassis and Triplet Hardware v1.0

Open Rack Charter. Authors: Gio Coglitore, Pierluigi Sarti, John Kenevey, Pete Bratach

High Availability Server Hardware v0.5 MB-draco-batentaban-0.5

Torpedo Design Concept Storage Server for Open Rack Hardware v0.3 ST-draco-chimera-0.3

Open Rack Hardware v1.0

January 16-17, 2013 Santa Clara

A QUICK AND EASY GUIDE TO SETTING UP THE DELL POWEREDGE C8000

Mini-ITX Addendum Version 1.1 To the microatx Motherboard Interface Specification Version 1.2. April 2009

(Examples of various colocation sites)

QuickSpecs. HP Fixed Cord PDUs & Extension Bars (Zero-U/1U Modular PDUs) Overview

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

StorTrends 3400 Hardware Guide for Onsite Support

Mini-ITX Addendum Version 2.0 To the microatx Motherboard Interface Specification Version 1.2. October 2010

Cabinets 101: Configuring A Network Or Server Cabinet

Server Technology, Inc.

Dimensions (HxDxW) Total Cabinet Area 89.96x x 24 in/ 2,285 x 1, x mm 95.47x 48 x 32 in/ 2,425 x 1,219.2 x 812.

HotLok Pass Through Blanking Panel

QuickSpecs. HP 480/277 Volt Solutions. Overview

Host OS Compatibility Guide

Server Technology Inc.

Calculating power requirements for HP ProLiant rack-mounted systems

How To Fit A Dll 2420 And 4220 Rack Enclosure

Out-of-box comparison between Dell and HP blade servers

Secure your IT equipment with confidence... secure with NetClosure

P O W E R S U P P L Y M A N U A L

INSTRUCTION MANUAL MODEL PCD-88

Dynamic Power Variations in Data Centers and Network Rooms

DCF Optimized Rack System Selection Guide

Recording Server Monitoring Tool

WHITEPAPER THE FUTURE IS CUSTOM: A TOTAL COST OF OWNERSHIP APPROACH TO DATA CENTER INFRASTRUCTURE DESIGN

How To Install A Cisco Cisco 520-T1 Router On A Network Card (Cisco) With A Network Cable (Cio) And A Network (Cnet) (Coconc) (Net) And An Ipo (

ZONIT POWER DISTRIBUTION SYSTEM ORDER CATALOG

Data Center Rack Systems Key to Business-Critical Continuity. A White Paper from the Experts in Business-Critical Continuity TM

ISS Data Centre Server Hosting. Service Description

Access Server Rack Cabinet Compatibility Guide

HP UPS R1500 Generation 3

Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers

October Intel Server Component Extended Warranty Program. Frequently Asked Questions (FAQ)

zseries 18-Slot Chassis 18-Slot 3U PXI Express Chassis with AC Up to 8 GB/s

BroadBand PowerShield. User Manual

Dynamic Power Variations in Data Centers and Network Rooms

How To Use A Tablet Computer In A Cart

DVI+HDCP 4x1 Switcher User Manual

HP Power Advisor utility: a tool for estimating power requirements for HP ProLiant server systems

MICROSOFT SOFTWARE LICENSE TERMS MICROSOFT SECURITY ESSENTIALS 1.0

Intel Server System S7000FC4UR

Page 1 of 5. Microsoft Software License Terms for: Windows XP Embedded and Windows Embedded Standard Runtime

Installation Guide Smart-UPS X External Battery Pack SMX120BP

Key Considerations for Selecting Server Cabinets for Seismic Areas

Open Source Used In Cisco Instant Connect for ios Devices 4.9(1)

Design Guide for Photonic Architecture

EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

Traditional Data Centers

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Proposal. In conjunction with the ITC Strategic Plan

ADEMCO 4500 Thermostat

W.H. Software Maintenance and Technical Support Agreement

Magic xpi 4.0 Release Notes

Application Briefs: Remote Office Environment

Advantium 2 Plus Alarm

EMC6D103S. Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features PRODUCT FEATURES ORDER NUMBERS: Data Brief

Self Help Guides. Setup Exchange with Outlook

Intel Data Center Manager. Data center IT agility and control

New Trading Platform NTP Customer Connectivity Topology Guide

Remote Alarm Monitoring System

Managing Data Centre Heat Issues

Dual-Cool Notebook Cooler Pad. User s Manual

PS/2 Extender USER MANUAL.

Microsoft Software License Terms Explained

Data Center Facility Basics

Increasing Data Center Efficiency by Using Improved High Density Power Distribution

QuickSpecs. HP Managed and Unmanaged Notebook Charging Carts. Models HP 30-Notebook Charging Cart

HP Managed and Unmanaged Notebook Charging Carts Overview. Models HP 30-Notebook Charging Cart. HP 30-Notebook Managed Charging Cart

ENTERPRISE EDITION INSTALLER END USER LICENCE AGREEMENT THIS AGREEMENT CONSISTS OF THREE PARTS:

Containment Solutions

guide Axis Camera Families for Autodesk Revit

Flobo Hard Disk Repair User guide

Storage Area Management (SAM) Clutter-Free, Super-Efficient Network Infrastructure Management

The software is sold on an AS IS basis. ALVARION, its affiliates or its licensors MAKE NO

Intel Technical Advisory

Model: Model: Description: Voltage: Amps: Ice Type: Unit Weight:

Single Port T1/E1 Tap

DATA CENTER ACCESS POLICY AND GUIDELINES

ASKING FOR ASSISTANCE

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

Data Center Design and Energy Management

Nest Learning Thermostat Installation Guide. Installation step-by-step

BlackBerry Business Cloud Services. Version: Release Notes

SUN BLADE 6000 CHASSIS

AMERICAN INSTITUTES FOR RESEARCH OPEN SOURCE SOFTWARE LICENSE

RealShot Manager Compression Server software

Power to the adaptable data center

42U/45U 28" Wide Rack Installation & Service Guide

AEGIS DATA CENTER SERVICES POWER AND COOLING ANALYSIS SERVICE SUMMARY

Dell Spotlight on Active Directory Server Health Wizard Configuration Guide

Racks & Enclosures. Deliver. Design. Define. Three simple words that clearly describe how we approach a Data Center project.

ATS Overhead Table Shelf System INSTRUCTION MANUAL

AVerMedia AVerKey imicro User s Manual

Electrical Systems. <Presenter>

Transcription:

Deploying OCP Hardware in a Collocated Facility Authors: Pierluigi Sarti, Technical Lead, Rack & Power, Facebook and Pete Bratach, Technical Writer, Facebook

1 Scope This specification describes how a data center operator or tenant can deploy Open Compute Project hardware the Open Rack or retrofitted 19" DAMAC racks with Intel v2.0 motherboards in a collocated facility in North America. 2 Contents 1 Scope... 2 2 Contents... 2 3 Overview... 3 3.1 License... 3 4 System Overview... 3 4.1 Reference Documenation... 4 5 Deploying the Open Rack... 4 5.1 Deploying Open Rack Triplets... 4 5.2 Mechanical Interface... 4 6 Retrofitting 19" Racks... 5 6.1 Efficiency Gains... 5 6.2 Serviceability Improvements... 5 7 Mechanical Drawings... 6 2 January 16, 2013

Open Compute Project Deploying OCP Hardware in a Co-Lo 3 Overview When data center design and hardware design move in concert, they can improve efficiency and reduce power consumption. To this end, the Open Compute Project is a set of technologies that reduces energy consumption and cost, increases reliability and choice in the marketplace, and simplifies operations and maintenance. One key objective is openness the project is starting with the opening of the specifications and mechanical designs for the major components of a data center, and the efficiency results achieved at facilities using Open Compute technologies. It's important to understand that these technologies are not limited to those who build and run their own data centers. This specification documents how Open Compute technologies can be deployed in a leased data center facility in North America. 3.1 License As of April 7, 2011, the following persons or entities have made this Specification available under the Open Web Foundation Final Specification Agreement (OWFa 1.0), which is available at http://www.openwebfoundation.org/legal/the-owf-1-0-agreements/owfa-1-0 Facebook, Inc. You can review the signed copies of the Open Web Foundation Agreement Version 1.0 for this Specification at http://opencompute.org/licensing/, which may also include additional parties to those listed above. Your use of this Specification may be subject to other third party rights. THIS SPECIFICATION IS PROVIDED "AS IS." The contributors expressly disclaim any warranties (express, implied, or otherwise), including implied warranties of merchantability, noninfringement, fitness for a particular purpose, or title, related to the Specification. The entire risk as to implementing or otherwise using the Specification is assumed by the Specification implementer and user. IN NO EVENT WILL ANY PARTY BE LIABLE TO ANY OTHER PARTY FOR LOST PROFITS OR ANY FORM OF INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES OF ANY CHARACTER FROM ANY CAUSES OF ACTION OF ANY KIND WITH RESPECT TO THIS SPECIFICATION OR ITS GOVERNING AGREEMENT, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), OR OTHERWISE, AND WHETHER OR NOT THE OTHER PARTY HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. 4 System Overview Data center operators and data center tenants whose infrastructure is located in a collocated facility can take advantage of the efficiency gains made by deploying Open Compute technologies. There are two strategies that can be employed: Deploying servers in Open Racks, either single-column or three column "triplet" racks Retrofitting 19" racks to accommodate OCP servers http://opencompute.org 3

4.1 Reference Documenation Open Rack http://opencompute.org/projects/open-rack/ (singlet, triplet specs) Battery backup cabinet (for use with the triplet implementation): www.opencompute.org/projects/battery-cabinet/ Intel motherboard v2.0: www.opencompute.org/projects/intel-motherboard/ 5 Deploying the Open Rack It's pretty straightforward to deploy Open Rack v1.0 in a data center, since it has the same footprint as a 19" rack. Particular consideration should be given to the data center floor weight limitations since the rack can exceed 1000kg fully loaded. To read more about the Open Rack, see the specification on the OCP site: http://opencompute.org/wp/wpcontent/uploads/2012/09/open_compute_project_open_rack_v1.0.pdf There is an electrical requirement: a 208V line-to-line PDU must be used, similar to the gpdu v0.3 for Open Rack, but at 208V (a specification is forthcoming). 5.1 Deploying Open Rack Triplets In general, you should be able to deploy an OCP triplet rack into a co-located facility. If you want to use triplets, consider the following items before you do so: Height. At a little under 95" tall, the triplet rack should fit into most data centers. Width. A little under 72" Weight. A fully loaded triplet can weigh more than 5000 pounds (2300kg). If you want to deploy an OCP triplet cabinet, you should verify the weight limitations of the floors in your facility. The triplet sits on 6 casters. Battery cabinet weight (in the event you can use the OCP battery backup cabinet in lieu of your facility's backup power system). The battery cabinet height is the standard 84", but it weighs more than 2220 pounds (1000kg) fully loaded. Check the weight limitations of the floors in your data center. Power. You need to install three 208V PDUs for each triplet rack. If you use the OCP battery cabinet, you also need a 208V variation of the battery cabinet and the OCP power supply. For more information about the Open Rack Triplet, read the following specifications: Open Rack v0.6: http://opencompute.org/wp/wpcontent/uploads/2012/09/open_compute_project_open_rack_v0.6.pdf Battery Cabinet Hardware v1.0: http://www.opencompute.org/wp/wpcontent/uploads/2011/07/datacenter-battery-cabinet-specifications.pdf (if you choose to use the OCP Battery Backup Cabinet for backup power instead of facility power, in conjunction with the OCP Power Shelf) Power shelf v0.3: http://www.opencompute.org/wp/wpcontent/uploads/2013/01/open_compute_project_power_shelf_v0.3.pdf 5.2 Mechanical Interface Details of the mechanical interfaces can be found in the CAD models: http://opencompute.org/wp/wp-content/uploads/2012/10/06-000017-with-pdus.zip 4 January 16, 2013

Open Compute Project Deploying OCP Hardware in a Co-Lo 6 Retrofitting 19" Racks Alternately, you can continue to use the 19" racks already in your colo, but retrofit them to accommodate the OCP Intel v2.0 server. You use a standard, vanity-free OCP Intel v2.0 server with no changes whatsoever, including the power supply. The power supply is rated down to 190V, so powering the servers with 208V is still within the normal operating range. But at 208V, the current needs to increase to keep constant power, which makes the power supply a little less efficient (~ 0.5% loss of efficiency) than when it's running at 277V. For more information about the Intel motherboard v2.0, read the specification: http://opencompute.org/wp/wpcontent/uploads/2012/05/open_compute_project_intel_motherboard_v2.0.pdf Facebook already implemented this at one of its data centers, and that process took about 3 months from design to deployment. The implementation requires only a few modifications from the OCP specifications before we deployed it: A modified server rack, to support the OCP v2.0 server chassis. Facebook used DAMAC's standard 19" rack (rails and all, part number FS84Z23393-3) and riveted two shelves and side panels from an OCP triplet to it, to provide the right-angle tabs that can accommodate the OCP v2.0 chassis. See the Open Rack triplet specification for details on these panels: http://opencompute.org/wp/wpcontent/uploads/2012/09/open_compute_project_open_rack_v0.6.pdf New power strips on the server racks, since the servers run off the data center's 208V line-to-line power instead of the OCP 277V line-to-neutral power. You can buy off-the-shelf strips from Server Technology. Depending upon your implementation, some racks may use both master and slave power strips, while others used only the master. The part number for the master 208V power strip is CS-24VYM313; the part number for the slave 208V power strip is CL-24VYM313. Each power strip can deliver a maximum of 8,640VA; it uses a NEMA L21-30P plug. New power cords connecting the OCP power supply to the new power strips. Facebook used a Tyco MATE-N-LOK connected to a standard C-13 connector. If your facility has its own battery backup power, or in-line AC UPS(s) you won't have to use the OCP 48V battery backup system and the OCP power supply. TOR switches can be powered with 208V if the facility supports AC backup power. Otherwise, they can be powered with 48Vdc from the OCP battery cabinet; in this case, the TOR switches must have a DC power option. 6.1 Efficiency Gains The servers operate at higher power conversion efficiency than non-ocp servers. The 60mm fans brought about the same thermal efficiencies. The inlet temperatures were cooler than those found in the average collocated facility, but the fans adapt and run more slowly without any changes on the fan controls. 6.2 Serviceability Improvements The racks have the same serviceability improvements, but fit easily into a collocated facility. The single-column design made for easier maneuvering of the racks in the data halls. http://opencompute.org 5

7 Mechanical Drawings Figure 1 Open Rack with PDUs 6 January 16, 2013

Open Compute Project Deploying OCP Hardware in a Co-Lo Figure 2 Open Rack Implementation Deployed in a Collocated Facility http://opencompute.org 7