Ultra-Low Temperature Chest Freezers

Similar documents
Ultra-Low Temperature V.I.P. Series Freezers. Integrated Ultra-Low Temperature Storage Solutions for Biosafety, Security and Performance

Freezers - Ultrafreezers. Platilab & Irilab Series

Refrigerators - Freezers. Ekofrigolab & Ekobasic Series

IC+ NEW inverter compressor technology delivers energy saving, high performance cooling

MODEL NU C ULTRALOW TEMPERATURE FREEZERS

08 FRIDGES & FREEZERS

-86 C ULTRALOW TEMPERATURE FREEZERS. NuAire, Inc Fernbrook Lane Plymouth, MN U.S.A

ECOCIAT. Domestic hot water heat recovery unit

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

S IJDERS SCIE TIFIC B.V.

REFRIGERATION. Standard Features & Accessories. Model Options. Freestanding 36 W. French-Door. Models include. VCFF136* Professional.

Vacuum drying oven for non-flammable solvents

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Thermo Scientific Heratherm Microbiological Incubators. Safe, easy and efficient

Blood Bank Refrigerators according to DIN Blood Plasma Freezers according to DIN 58375

Heating oven with mechanical convection

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Refrigeration Compressed Air Dryer Buran Ultrapulse

USER S MANUAL HSC-24A

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

French Door Refrigerator E23BC78IPS professional series

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Digital Ultra-Low Temperature Freezer. Digital Ultra-Low Temperature Freezer, Dual SHFS TM, Chest Type. Dual SHFS TM, Upright Type

CelCulture. CelCulture CO2 Incubator Model CCL-170_-_. CO2 Incubator with Integrated Cooling System Solution for Highly Specialized Applications

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Professional Kitchens

Material test chamber with mechanical convection

Heating oven with mechanical control

MUELLER FALLING FILM CHILLERS

REFRIGERATION. Standard Features & Accessories. Model Options. Built-In 30 W. Full-Height Wine Cellar. All models include. VCWB300 Professional

Climate chamber with illumination

SANDWICH/SALAD PREP & MEGA TOP UNDERCOUNTER REFRIGERATOR UNDERCOUNTER FREEZER

MAC-120HE-01 Air-Cooled Chiller

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

LABORATORY / MEDICINE / PHARMACEUTICAL REFRIGERATORS

CRAC Precision climate control units for data centres

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

LyoBeta. R+D Freeze-Dryers

Incubator with mechanical convection

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

-86 C Freezer Accessories. New Brunswick Freezer Accessories. A wide selection of racks, monitoring systems and more!

BIOMEDICAL REFRIGERATORS

LABOKLAV. Autoclaves Made in Germany.

WAECO COOLMATIC 2.8 CUBIC FEET 12/24 VOLTS DC & 110 / 220 VOLTS AC BUILT-IN REFRIGERATOR-FREEZER WITH FLUSH MOUNT FRAME

IV. Rear Mount System

Variable Capacity Compressors, a new dimension for refrigeration engineers to explore

Split units TH with hermetic compressors

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

AIR-COOLED CHILLERS APPLIED SYSTEMS. EUWA*5-24KAZW - EUWY*5-24KAZW -

Cooling kw Heating kw

86 C Freezer Accessories. More Choices. Choose from a Wide Selection of Racks, Monitoring Systems and Other New Brunswick Freezer Accessories

Coldrooms designed for your application

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

Frequently Asked Questions. Isotherm Fridge & Freezers

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

A GUIDE TO SELECTING YOUR INDUSTRIAL OVEN

Convection Ovens. BX Classic. Models BX4 / FG 189C, BX / FG 158C, BX10 / FG 180C. Operator's Manual

BR I Blood Bank Refrigerators

THE FIRST OF A NEW CLASS OF PRODUCTS

SECTION MORTUARY REFRIGERATORS

CoolTeg Plus Chilled Water (CW) version: AC-TCW

HOSHIZAKI AMERICA, INC.

High-efficient gas boiler CompactGas

Guide to Laboratory Equipment. Panasonic the new name for SANYO.

Commercial Portable Air Conditioners

Thermo Scientific Forma -86 C Chest and Upright Freezers. Sample Storage Products You Can Trust

ThermoSorb Desiccant Dryers

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

TWE+TTA TWE+TWA T.R.

Thermo Scientific Heratherm Microbiological Incubators. Safe,

S G G S G G S G G S G G. FR / MF range. Deep Freezers & Plasma Storage Freezers

Nirvana. Cycling Refrigerated Dryers

FOXAIR 60/50 ALL MODELS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DESIGN STANDARDS SECTION

CE6500 Energy Recovery Ventilator

Morgue refrigeration unit

Laminar Flow Cabinets

OT 40L / 90L. Laboratory Steam Sterilizers

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS

Shakers, Incubators, Clean Benches, Water Baths, Drying Ovens

TECHNICAL DATA E-PRO COLD UNITS Refrigerated glass display units, CDDL, CDD and CDDH series

Laboratory Line. Vertical and Bench-Top Life Science Autoclaves

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

Product Information Sheet UH28CS-12kV Hi Pot Tester

VDL 53 - Vacuum drying oven for flammable solvents

DIGITAL PARAFFIN DISPENSER MODEL DP 2010 PROCEEDING MANUAL

TECHNICAL SPECIFICATION. StirLIN-1 Economy Liquid Nitrogen System

YCAA-B AIR COOLED LIQUID CHILLER

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

Nexus FS Point of Use Installation Guide

Horizontal Steam Sterilizers. Healthcare Line. Since

Commercial Refrigeration Temperature and Defrost Controls

FVA/A1 saturated-steam sterilizer

Superior technology with new Symphony Plus

CW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/

Incubators, cooled incubators, drying ovens, sterilizers, climatic chambers

Sensors for Air-conditioning in Automobiles

Transcription:

Ultra-Low Temperature Chest Freezers SANYO Ultra-Low Temperature Chest Freezer lineups for ultra-low temperature storage needs to support the forefront of life science researches. MDF-94AT MDF-193 MDF-16

The Ideal 2 C, 86 C Freezing Environment in Capacities from 86 L to 71 L Ideal for long term preservation of biologicals, blood components and various cell line, Panasonic preservation systems employ microprocessor control to maintain a high-precision temperature environment. They are not affected by ambient temperature, minimizing uneven temperature distribution within the chamber, and a temperature rise during door opening. 2 C Ultra-Low Temperature Chest Freezer For stable long-term storage MDF-16/16ATN TEMPERATURE EFFECTIVE CAPACITY 2 C 128 L (4.cu.ft.) 9 (3.6) (19.7) 14 (.1) 8 (31.) 4 (17.7) 2 (2.) 72 (22.) 667 (26.3) 94 (37.2) (4.1) MDF-16 6 4 Ambient temp. 3 C, no load 8 1 14 16 2 8 1 14 Ambient temp. 3 C, no load 16 1 2 3 4 6 7 8 9 2 LN2 injection at 13 C SV of backup system 13 C LN2 L 3 4

For MDF-16/16ATN Why Freeze to 2 C? Recrystallization Mechanism (Artist s Concept) 8 C 13 C Recrystallization point 2 C Hexagonal crystal Cubic crystal Amorphous ice crystal World s lowest 2 C freezer ensures stable cell and tissue preservation An important factor to consider when preserving cells or tissue at ultra-low temperatures is to prevent amorphous ice crystals from recrystallizing within and outside the cells. Samples that are maintained in an ultra-low temperature freezer at 2 C which is far lower than the recrystallization point ( 13 C for pure water) can be preserved semi-permanently. Preservation at ultra-low temperatures maintains vitrification without crystallization occurring inside and outside cells. In contrast to conventional liquid nitrogen preservation containers, freezer preservation has numerous advantages: no sample contamination, no sudden liquid eruptions, as well as low operational costs. Panasonic s MDF-16 and 16ATN make long-term storage below the recrystallization point easier and more stable than ever before. Specially designed compressor and cascade refrigeration system Specially designed for rugged ultra-low temperature applications in a laboratory environment (HFC refrigerants only). Micro-processor Temperature Control with LED Digital Display Extremely accurate, easy-to-read display. The temperature inside the freezer can be set and monitored easily by means of a microprocessor temperature control with an LED digital display. The thermostat incorporates a platinum resistor (Pt. Ω), precision and durability. Integrated Cabinet Design High-performance refrigeration system with foamed-in-place cabinet insulation maximizes interior temperature uniformity and protects against fluctuating ambient temperatures. Hot line for secure sealing Moisture condensation at the top edges of the cabinet due to differences in temperature inside and out causes frost and icing problems that may reduce heat insulation efficiency and obstruct door movements. These problems are prevented by the hot line by means of which hot gas from the higher temperature circuit is circulated through the problem areas. Hot line Advanced Features Self-diagnostic function The temperature sensor, filter sensor and cascade sensor monitor operation conditions continuously. Should abnormality be picked up, an error code and the current temperature will be displayed in turn. Ring back function The alarm buzzer can be silenced by pressing the BUZZER key on the control panel. (The remote alarm signal is not cancelled.) Should the alarm condition continue after a certain suspension, the alarm buzzer sound will resume. Easy Maintenance (MDF-193/193AT have no filters) Filter check lamp notifys the user of a clogged condenser filter.the condenser filter is situated at the front panel to make filter removing and cleaning easier. Note: The position of the filter check lamp is shown on the control panel (see photo shown at the bottom of this page). Standard casters and levelling feet Standard-equipped heavy duty casters make it easy to move a freezer when necessary. The levelling feet keep a freezer level and firm on the floor. Safety Device Built-In Temperature & Power Failure Alarms (Lamp/Buzzer) In case of power failure or an irregular rise in temperature, a rechargeable batteryoperated indicator lamp and alarm will be activated. A compact recording unit which automatically records the inside temperature, and a backup system with liquefied CO2 or N2 which is selfactivated when a power outage occurs are also available separately. This equipment helps insure that the contents will be protected in the event of any power failure or mechanical trouble. Control panel 12 8 1 2 3 4 6 7 9 11 MDF-394AT 1 Alarm lamp and buzzer 2 Filter check lamp 3 Buzzer key 4 Alarm test key Mode setting key 6 Digit shift key 7 Numerical value shift key 8 Power switch 9 CO2 back-up test swich (AT type only) CO2 back-up swich (AT type only) 11 Battery switch 12 Temperature recorder

86 C Ultra-Low Temperature Chest Freezers Ideal for large-capacity preservation MDF-794/794AT TEMPERATURE EFFECTIVE CAPACITY 86 C 71 L (24.8cu.ft.) 27 (1.2) 21 (83.1) 861 (33.9) 77 (3.3) 38 (1.) 79 (31.3) 762 (3) 184 (72.4) 7 (42.1) (19.7) MDF-794AT (4.1) 3 Ambient temp. 3 C, no load 3 7 8 9 1 2 3 4 6 7 8 9 3 Ambient temp. 3 C, no load 3 7 8 9 1 2 3 4 6 7 8 9 SV of backup system 7 C LCO2 3kg 2 3 3 Ideal for middle-sized installation space MDF-94/94AT TEMPERATURE EFFECTIVE CAPACITY 86 C 487 L (17.1cu.ft.) (79.1) (61.) 861 (33.9) 77 (3.3) 38 (1.) 79 (31.3) 762 (3) 128 (.4) 7 (42.1) (19.7) MDF-94AT (4.1) 3 Ambient temp. 3 C, no load 3 7 8 9 1 2 3 4 6 7 8 9 3 Ambient temp. 3 C, no load 3 7 8 9 1 2 3 4 6 7 8 9 SV of backup system 7 C LCO2 3kg 2 3 3

Low-profile design for easy access to stored materials MDF-394 TEMPERATURE EFFECTIVE CAPACITY 86 C 39 L (.9cu.ft.) 186 (73.2) 14 (.1) 891 (3.1) 8 (31.) 38 (1.) 66 (26.) (.9) 11 (44.1) 94 (37.2) (.) (4.1) MDF-394 3 Ambient temp. 3 C, no load 3 7 8 9 1 2 3 4 6 7 8 9 3 3 7 8 Ambient temp. 3 C, no load 9 1 2 3 4 6 7 8 9 SV of backup system 7 C LCO2 3kg 2 3 3 Compact, space-saving unit optimized for private use MDF-193/193AT TEMPERATURE EFFECTIVE CAPACITY 86 C 86 L (3.cu.ft.) 791 (31.1) 7 (29.) 7 (27.6) 38 (1.) 68 (2.9) 94 (37.2) 4 (16.) MDF-193 48 (18.9) 43 (16.9) 3 Ambient temp. 3 C, no load 3 7 8 9 1 2 3 4 6 7 8 9 3 3 7 8 Ambient temp. 3 C, no load 9 1 2 3 4 6 7 8 9 SV of backup system 7 C LCO2 3kg 2 3 3

Specifications Temperature Range Exterior Dimensions (W x D x H) Interior Dimensions (W x D x H) Effective Capacity Exterior Cabinet Interior Cabinet Inner Lid Insulation High stage side Compressor Low stage side High stage side Evaporator Low stage side High stage side Condenser Low stage side Temperature Control Temperature Display Sensor Safety Alarm system Optional Accessories Storage Racks (Aluminium) Case Dimensions (W x D x H) Number of Drawers Applicable Model (Rack capacity) MDF-19SC-PW 7 x x 413 (mm) 8.1 x.7 x 16.3 (inch) 3 MDF-193/193AT (6) MDF-16/16ATN MDF-794/794AT MDF-94/94AT MDF-394 MDF-193/193AT 13 C to 2 C C to 86 C C to 86 C 14 x 8 x 94 (mm).1 x 31. x 37.2 (inch) x 4 x 72 (mm) 19.7 x 17.7 x 22. (inch) 128 liters (4. cu.ft.) 27 x 77 x 7 (mm) 1.2 x 3.3 x 42.1 (inch) 184 x x 762 (mm) 72.4 x 19.7 x 3. (inch) 71 liters (24.8 cu.ft.) x 77 x 7 (mm) 79.1 x 3.3 x 42.1 (inch) 1,28 x x 762 (mm).4 x 19.7 x 3. (inch) 487 liters (17.1 cu.ft.) 186 x 8 x 94 (mm) 73.2 x 31. x 37.2 (inch) 11 x x (mm) 44.1 x. x.9 (inch) 39 liters (.9 cu.ft.) 7 x 7 x 94 (mm) 29. x 27.6 x 37.2 (inch) 48 x 43 x 4 (mm) 18.9 x 16.9 x 16. (inch) 86 liters (3. cu.ft.) Galvanised steel with baked on finish Aluminum plate Stainless steel 1 4 3 1 Foamed-in-place rigid polyurethane Fin and tube type Cascade condenser Microprocessor control system, Non-volatile memory Net Weight (Approx.) 26kg (84 lbs.) 16 272kg (6 lbs.) 16ATN Voltage specification by destination Representative destination Europe 23V, Hz (CE) Korea 2V, 6Hz Thailand 2V, Hz ATN: LN2 backup system, temperature recorder AT: LCO2 backup system, temperature recorder MDF-16-PE/16ATN-PE MDF-16-PK/16ATN-PK MDF-16-PB/16ATN-PB MDF-39SC-PW x x (mm) 6.1 x 6.1 x.3 (inch) 4 MDF-394 () Inventory Racks (Stainless steel) Box Type External Dimensions (mm) Freezer Model (Capacity) Width Depth Height (Rack capacity) IR-7C-PW IR-9C-PW IR-213C-PW IR-3C-PW IR-36C-PW IR-39C-PW 2 (7) 2 (9) 2 (13) 3 () 3 (6) 3 (9) 4 18 92 4 18 747 MDF-193 (6) MDF-394 (21), 16 (9) MDF-94 (24), 794 (36) MDF-193 (6) MDF-394 (21), 16 (9) MDF-94 (24), 794 (36) Hermetic type, 1, W Hermetic type, 1, W Cascade condenser Tube on sheet (shared with interior) Fin and tube type Shell and tube type Cascade condenser 33kg (739 lbs.) 794 34kg (761 lbs.) 794AT MDF-49SC-PW MDF-9SC-PW 7 x x 9 (mm) 7 x x 66 (mm) 8.1 x.7 x 21.2 (inch) 8.1 x.7 x 26.2 (inch) 4 MDF-94/94AT (18) MDF-16/16ATN (6) MDF-794/794AT (24) IR-9C-PW MDF-39SC-PW Hermetic type, 4 W Hermetic type, 7 W Microprocessor: Keypad input Set value memory: non-volatile memory Temperature Recorder Recording Range Freezer Model 219kg (483 lbs.) MTR-8H-PW to + C MDF-193 MDF-394 MDF-94 MDF-794 ULT-Freezer Backup Kits Hermetic reciprocated type, 4 W Tube-on-sheet type Finless tube type Digital display Platinum resistance (Pt. W) Platinum resistance (Pt. W) Platinum resistance (Pt. W) Cylinder key on the lid handle Adjustable high and low temp. alarm Selectable high temp. alarm (+ C & + C from set point) (± C to ± C from set point) Power failure alarm, Filter check lamp (Except MDF-193/193AT which have no filters), Remote alarm contact MDF-794-PE/794AT-PE MDF-794-PK/794AT-PK MDF-794-PB 291kg (642 lbs.) 94 31kg (664 lbs.) 94AT 3kg (227 lbs.) 193 9kg (24 lbs.) 193AT MTR-H-PW 17 to +3 C MDF-16 CVK-UB2-PW/UB2I-PW: LCO2 Backup Kit for MDF-794/94/394 CVK-UBN2-PW/UBN2I-PW: LN2 Backup Kit for MDF-794/94/394 CVK-A-PW: Built-in LCO2 Backup Kit for MDF-193 CVK-AT2-PW: LCO2 Backup Kit for MDF-16 CVK-ATN2-PW: LN2 Backup Kit for MDF-16 I : version for North America only *Cooling performance is indicated by the temperature reached at the center of the freezer (at ambient temperature of 3 C with no load). In order to use the freezer at a stable temperature for a long time, it is recommended that the temperature be set to at least C higher than the indicated lowest temperature. In addition, depending on the usage conditions, it may not be possible to reach the indicated lowest temperature. Caution: Panasonic guarantees the product under certain warranty conditions. Panasonic in no way shall be responsible for any loss of content or damage to content. Appearance and specifications are subject to change without notice. IR-36C-PW MDF-94-PE/94AT-PE MDF-94-PK MDF-94-PB/94AT-PB MDF-9SC-PW MDF-394-PE MDF-394-PB MDF-193-PE/193AT-PE MDF-193-PK Panasonic Healthcare Co., Ltd., Gunma Factory is certified for: Quality management system: ISO91 Medical devices quality management system: ISO1348 Panasonic Healthcare Co., Ltd., Gunma Factory is certified for: Environmental management system: ISO141 DISTRIBUTED BY: http://biomedical.sanyo.com/ 141-12-4