PORTABLE AIR CONDITIONER



Similar documents
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Portable Air Conditioner

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Important Safeguards

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Operating Instructions Split System Air Conditioner

Use and Care Manual. Model CPA12KH AIR CONDITIONER

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Meaco 30L and Meaco 40L dehumidifier instruction manual

USER S MANUAL HSC-24A

Air Conditioner. Portable BTU/h 2.9kW INSTRUCTION MANUAL CWAC11 CPIN Important! Please read these instructions carefully.

PORTABLE AIR CONDITIONER

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

SPLIT WALL MOUNTED TYPE AIR CONDITIONERS OWNER'S MANUAL

Owner s Manual. SRCOOL12K (120V, 60 Hz) SRXCOOL12K (230V, 50 Hz) Portable Air Conditioning Unit. Introduction 2. Important Safety Instructions 2

Dehumidifier Users manual. For Models: DH45S DH65S

OPTIONAL SLENDER REMOTE CONTROL

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

ACW200C / ACW200CH. Innovative AutoDrain Technology. Owner s Manual Portable Air Conditioner with Heat

Split Type Room Air Conditioner. KSWM units

NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

Get Me Cool Now Portable Air Conditioner User s Manual

Climax Air Inc. DC Inverter Portable Air Conditioner Model VS12 12,000 BTU Introducing The World s Most Efficient Portable Air Conditioner

PORTABLE AIR CONDITIONER (LOCAL)

USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB A(1) ENGLISH ESPAÑOL

Split Air Conditioner

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2

Wall Mounted Mini Split Heat Pump Air Conditioner

Air Conditioner P O R T A B L E. Instruction Manual. Your Guarantee. For model WA-1220M WA-1220H, WA-1220E. Portable Air Conditioner / Heater

Operating Instructions Air Conditioner

SYSTEM Inverter Air Conditioners

Room Air Conditioners

WHYNTER ECO-FRIENDLY 14,000 BTU PORTABLE AIR CONDITIONER WITH HEATER

Instruction manual for Firstline FCS12000CH

Portable Evaporative Air Cooler for Indoor Use. OWNER S MANUAL Read and save these instructions before use. Model: CL25AE

SILENT10 PORTABLE AIR CONDITIONER USER MANUAL

WINDOW ROOM AIR CONDITIONER

LG Room Air Conditioner OWNER'S MANUAL

Room Air Conditioners

MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial #

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

OWNERS MANUAL. PAC 210 U Portable Windowless Air-Conditioner

Installation Instructions and Owner's Manual. Double-Hung Windows Room Air Conditioner. This manual must be left with the owner of the equipment.

Dehumidifier D 850E. - Instruction manual version 02

LG Room Air Conditioner OWNER'S MANUAL

CARING FOR YOUR WATER HEATER

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

WALL MOUNTED SPLIT TYPE AIR CONDITIONER

Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use. OWNER S MANUAL Read and save these instructions before use.

INDOOR UNIT/OUTDOOR UNIT

Platinum Range PLAC12000HP PORTABLE AIR CONDITIONER WITH HEAT PUMP USER MANUAL HIGH MID COLL HEAT DRY FAN LOW F C TIMER SLEEP SWING

FOXAIR 60/50 ALL MODELS

Room Air Conditioners

Operating Instructions Air Conditioner

Multi System. 16 SEER, Inverter System. 9,000 to 18,000 BTU/Hr. Single Split

GenStore Archive Cabinet

Wine Cooler with Thermo-Electric Cooling & Heating Technology

DAIKIN ROOM AIR CONDITIONER MODELS. Operation Manual ENGLISH ESPAÑOL TURKISH

Reverse Cycle Inverter Split System Air Conditioner

Before using your air conditioner, please read this manual carefully and keep it for future reference. ROOM AIR CONDITIONER

USER S INFORMATION MANUAL

PTAC Preventive Maintenance Guide. Step-by-step instructions and information to keep your units operating in peak condition

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

OWNER S MANUAL VMH 09/12/18/27/36 InverterFlex

Portable Evaporative Air Cooler with Heater for indoor use. OWNER S MANUAL Read and save these instructions before use.

OWNER S MANUAL SPLIT SYSTEM AIR CONDITIONER. G Series Cooling

LG Floor Standing-Type Air Conditioner OWNER'S MANUAL

STAINLESS STEEL WINE / BEVERAGE COOLER INSTRUCTION MANUAL HVBC31ST

AIR CONDITIONER (SPLIT TYPE)

the Soft Top Breville Customer Service Center Instruction Book - Livret d instructions

PORTABLE AIR CONDITIONER CLIMATISEUR PORTATIF ACONDICIONADOR DE AIRE PORTATIL

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

Inverter Single Zone Ductless Mini Split Heat Pump

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

R410A SPLIT SERIES DC INVERTER

SAFEGUARDING THE ENVIRONMENT

GENANO 4500 MEDICAL AIR PURIFICATION DEVICE

LG Multi Type Air Conditioner

ALL IN ONE. Heat Pump Water Heater

Portable Air Conditioner

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

Taurus Series YORK Window Air Conditioners

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0

AIR CONDITIONER OWNER S MANUAL. ENGLISH ITALIANO ESPAÑOL FRANÇAIS DEUTSCH πãõ PORTUGUÊS NEDERLANDS

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

WHYNTER ECO-FRIENDLY 14,000 BTU PORTABLE AIR CONDITIONER

AIR CONDITIONER OWNER S MANUAL ENGLISH FRANÇAIS ESPAÑOL

DEHUMIDIFIER MODELS: SD-31E / SD-41E / SD-61E / SD-71E INSTRUCTION MANUAL

evo + HIGH-WALL DUCTLESS AIR CONDITIONING & HEATING SYSTEM OWNER S MANUAL Models: GWH09AB-D3DNA2D GWH18AC-D3DNA2D GWH24AC-D3DNA2D

CEILING CASSETTE FAN COIL UNIT

Transcription:

PORTABLE AIR CONDITIONER MAC 7500 Owner s Manual Air Conditioner Dehumidifier Oscillating Fan Please read this owner s manual carefully before operating the unit. POWERED BY 66126113.p65 17

INTRODUCTION Thank you for purchasing the Mac 7500 portable air-conditioner. This unit is designed for improving living and working comfort by providing cooling, dehumidifying and fan functions only with a minimum installation required. With its whisper quite operation and attractive design, you will enjoy the convenience and comfort that this unit provides for many years to come. When operating as an air conditioner, this unit is designed for spot cooling or cooling for a room no larger than 150 square feet with the standard ceiling height 7-1 / 2 ft. ALERT SYMBOLS The following symbols used in this manual, alert you to potentially dangerous conditions to users, service personnel or the appliance: this symbol refers to a hazard or unsafe practice, which can result in severe personal injury or death. this symbol refers to a hazard or unsafe practice, which can result in personal injury or product or property damage. IMPORTANT SAFEGUARDS Read these instructions carefully before using this air conditioner. If you still have any ditticulties or problems, consult your dealer for help. Never use or store gasoline or other flammable vapor or liquid near the air conditioner. This air conditioner has no ventilator for taking in fresh air from out of doors. You must open doors or windows frequently when you use gas or oil heating appliances in the same room,which consume a lot of oxygen from the air. Otherwise, there is a risk of suffocation in extreme cases. 1 66126113.p65 1

Unplug unit from the electrical outlet when not in use and before cleaning it. Do not use an adapter plug extension cord. Do not use near gas appliances, open flames (fireplaces) or near the vicinity flammable liquids. Do not operate this unit if it had a damaged cord or plug or if it is not warking properly, or has been dropped or damaged in any manner. Take the unit to the nearest authorized. Service Facility for examination, repair or electrical/mechanical adjustment. The use of accessories and attachments not recommended or sold by may cause fire, electric shock or injury. To protect against risk of electrical shock, do not immerse the unit, cord or plug in water or any other liquid. Do not cut or remove the third (ground) prong from the power cord. If the plug gets hot, call a qualified electrician. Close supervision is required when the unit is used by or near children. Do not stick anything into the air outlet of the air conditioner. Do not use in a room with poor air circulation. Do not expose the unit to direct sunlight. Do not use the unit near water. 2 66126113.p65 2

PACKAGE CONTAINS: Mobile Air Conditioner Air Exhaust Duct Exhaust Duct Window Kit Adapter Romote Controller LITHIUM BATTERY 3V Window Kit - 3 Sliding Panels Window Kit Fastener Screws (4) User Manual NAMES OF PARTS FRONT control panel air flow guider swing louver front air outlet grill handle water tank castol cable(power cord and plug) BACK upper air inlet grill hot air outlet grill lower air inlet grill Outlet for Continuous Drainage Use exclusively for continuous drainage. Don't pull out the outlet except for this application.otherwise the drain will leak. 3 66126113.p65 3

Exhaust Duct Exhaust Duct Unit Terminal End Window Kit Adaptor Window Kits Exhaust Duct When you use the unit as an air conditioner, the hot exhaust air must be directed out of the room. The exhaust duct is used to allow the hot air out. DO NOT INSTALL OR USE THE EXHAUST DUCT WHEN THE UNIT IS OPERATED AS A DEHUMIDIFIER OR FAN. a) b) Slide exhaust connector all the over the hot Air outlet grill. Mount the external and of the exhaust duct onto a bole of 5 1 / 4 " (132 mm) on the wall for optional wall hot air outlet installation. 4 66126113.p65 4

c) Or connect the window kit adaptor to the external end of the exhaust duct for a window or sliding door hot air outlet installation. NOTE: In order to increase the efficiency, the exhaust duct should be keep as short and straight as possible. The exhaust hose can be cut shorter by unthreading either end of the exhaust duct counter clockwise. It is not recommended to increase the manufacturer s length of the exhaust hose. This may impede or damage the unit. Window Kit Installation a) Open window or sliding door for approximately 5 inches (130 mm). b) Adjust the length of the window kit to the same length of the window or the sliding door. Use all three panels if necessary. c) Use screws to affix the window kit length. d) Place the window kit to the window or sliding door. Close the window or door as far as it goes. e) Mount the window kit extension of the exhaust host onto the window kit. f) Use screws on the window kit extension if necessary. NOTE: When using the window kit on a window or sliding door it will cause the window or sliding door not to be properly closed and locked. Additional security measurements should be taken. windows exhaust air opening 5 66126113.p65 5

CONTROL PANEL REMOTE CONTROLLER 6 66126113.p65 6

OPERATION USING CONTROL PANEL 1) For Manual Mode: Press the Mode Button a) Cool - Cooling function on indicator. b) Dry - Dehumidify function on indicator. c) Fan - Fan on indicator. 2) For Cooling Operation: a) Be sure that the drain tank is properly placed in the unit. b) Install the exhaust duct properly. c) Plug the Power Cord to the power outlet. d) Press the Mode Button until the cool indicator is on. NOTE: During hot days, the unit will cool off the room most efficiently by setting the fan at the lowest speed. Reducing the length of the exhaust duct, insulating the exhaust duct and keeping direct sunlight to a minimurn will also improve the cooling efficiency. 3) Dehumidifying Operation: a) Be sure that the drain tank is properly placed in the unit. b) Plug the Power Cord to the power outlet c) Turn on the unit by pressing the ON/OFF Button on the control panel. d) Press the Mode Button until the DRY indicator is on. NOTE: Do not use the exhaust duct when the unit is running at dehumidisying mode. You must remove the exhaust duct from the unit. When the unit is running at dehumidifying mode, the fan speed cannot be adjusted. Keep the windows and the doors closed to aid the effectiyeness of the unit in removing the moisture from the room. 7 66126113.p65 7

4) Fan Operation: a) Plug the Power Cord to the power outlet. b) Turn on the unit by pressing the ON/OFF Button on the control panel. c) Press the Mode Button until FAN indicator is on. d) Select the fan speed by pressing the Fan Speed Button. NOTE: When the unit is running on fan mode, the exhaust duct is inoperative and is not required. OPERATION USING REMOTE CONTROLLER The remote controller provided with the unit may operate this portable air conditioner. The remote controller uses one LITHIUM BATTERY 3V. Install the battery before using the remote controller. 1. Press the On/Off key to turn on the unit. 2. Press Mode Key to: a) Cool indicator is on = Cooling Function b) Dry indicator is on = Dehumidify Function c) Fan indicator is on = Fan Function 3. Fan Speed: a) Press the Fan Speed key to turn fan speed to high or low. 4. Swing: a) Press swing key to turn on auto swing function. Do not dispose of batteries in fire, batteries may explode or leak. 8 66126113.p65 8

CONDENSATE WATER DRAINAGE 1) Internal Water Tank When operating in cooling or dehumidifying mode, the condensate water will drain into the internal water tank. Depending on the surrounding humidity, the unit can continuously operate for 2 to 12 hours before the internal water tank is full. When the internal water tank gets full, a beep slarm will sound eight times for 15 seconds. The compressor stops running and the fan will continue to run in the set speed for three minutes before the entire unit automatically shuts off. When the water tank is full, take out the entire water tank slowly and discard the water inside the tank, place it back to its original position. You will then be able to turn on the unit again. If you want to take out the internal tank before it is full of water, please stop the unit first. Wait for 3 minutes before taking out the water tank to prevent the condensate water from discharging into the unit. NOTE: Do not take out the water tank when the unit is running on either cooling or dehumidifying mode or the alarm will sound and the compressor stops. The mode will automatically change to FAN mode and the compressor will require approximately 3 minutes to restart to the cooling/dehumidifying cycle. 9 66126113.p65 9

Do not remove the water tank when the unit is in use. Always turn Off the unit before removing water tank. Periodically inspect and clean the drain valve to prevent clogging. METHOD OF CONTINUOUS DRAINAGE: 1. Slide out drain valve from the left side of the unit. 2. Connect a rubber pipe to the valve (not included). 3. Make sure the rubber pipe drains downward. 10 66126113.p65 10

AIR FILTER Soleus Air recommends cleaning your air filter at least after every two weeks of use. Keeping your air filter clean will maximize the performance and life of this product. Open the air filter cover on the left side of the unit (fig. a) Remove the filter from the cover. Wash the filter using warm water and a mild dishwasher detergent. Allow to air dry before replacing in unit. Fig. a Water Tank Using the handle, slowly remove water tonk from unit (fig. b). Pour out any condensation accumulated in water tank (fig. c) Wash water tank using warm water and a mild dishwasher detergenr. Allow to dry completely. Replace water tank in unit (fig. d). Fig. b Fig. c Fig. d 11 66126113.p65 11

NOTE: Be very careful when using an external water tank. The unit will not shut off automatically when an external water tank is full. Spill water can cause substantial damages to carpet, furniture and other valuables. Do not use lengthy drainage tabing without a condensate water pump. MAINTENANCE NOTE: Make sure power is off and the plug is pulled out of the power outlet before performing any maintenance activities. 1) Case a) Keep the unit from being exposed directly to the sun for possible color fading. b) Clean the surface with a damp cloth and dry it with a soft towel. 2) Storing the Unit for an Extended Period of Time a) Ensure that the water drain tank is empty. Remove the stopper from the water drain pipe and allow draining until empty. (Fig. e) b) The water drain valve should be reinserted back in the unit. c) The filter should be cleaned and air dried. d) The power cable must be disconnected from power outlet and neatly rolled. (Fig. f) e) The unit should be stored in a dry place. Fig. e Fig. f 12 66126113.p65 12

TROUBLE SHOOTING PROBLEM POSSIBLE CAUSE REMEDY Unit does not operate Unit does not cool room Unit is umplugged Drain tank is full Water tank not installed correctly Air exhaust is clogged There is a heating source in the room Air filter is dirty Air exhaust is not installed correctly Room is too big or too much amblent sunlight is reaching in Secorely plug receptacle into the power outlet Empty water tank Completely insert water tank Clear exhaust hose Turn down or off the other heating source Clean or replace the air filter Check the air exhaust duct to make sure that the hot exhaust air is let out of the room freely This unit provides spot cooling or cooling for a room no larger than 150 square feel with standard ceilling height 7 1 / 2 " There is frost on the evaporator The unit will defrost automatically and return to operation afterwards In dehumidifying mode, no cool air coming out There is frost on the evaporator The unit will defrost automatically and will return to operation afterwards Noise or vibration Surface is not level Place unit on a level surface and away from obstructions Surface is not level Drainage pipe is loose Place unit on a level surface away from obstructions Unit has been moved When moving unit, empty drain tank first and keep unit upright at all times Stopper on water drain pipe is loose Make sure the stopper on the water drain pipe is securely in place Machino stops and starts Air exhaust is not attached proparty Air exhaust is curved too much Check installation of air exhaust hose Try to keep the air exhaust horizontal 13 66126113.p65 13

SPECIFICATIONS Model # MAC - 7500 Power Source Cooling capacity Dehumidifyling capacity Cooling input power 115V ~ / 60Hz 7500 BTU/h 24.0 liters/day 1000W Rated current 8.7A Refrigerant type Refrigerant capacity Operating Range - Cooling (indoor air temperature) HCFC R22 1.15 lb Max 95 F Dry Bulb - 71 F Wet Bulb Min 67 F Dry Bulb - 57 F Wet Bulb Unit dimensions (H x D x W) 31" x 12.8" x 16.3" Specifications are subject to change without notice PRODUCT INFORMATION If you have problems or questions concerning your air conditioner, you will need the following information. Model and Serial numbers are on the nameplate on the back of the unit. Model No. Serial No. Date of Purchase Dealer s Name Dealers Address Purchaser s Name Day Phone Evening Phone 14 66126113.p65 14

DISCLAIMER ALL INFORMATION AND THE TECHNICAL SPECIFICATIONS PRESENTED IN THIS USER S MANUAL ARE THE PRESENTATION OF THE MANUFACTURER SOLEUS INTERNATIONAL HAS NOT CONDUCTED INDEPENDENT TESTS FOR THE INFORMA- TION AND THE SPECIFICATIONS PRESENTED HEREWITHIN. CONTACT INFORMATION For Optional and Spare Parts Technical Support Warranty Claim Customer Service Please Call (888) 8-Soleus Or Write to: Soleus International Inc. 9451 Telstar Ave. El Monte CA 91731 USA www.soleusair.com 15 66126113.p65 15