Ubiquinone (Coenzyme Q 10 ) HPLC Assay

Similar documents
Vitamin C HPLC Kit. For reference use only For research use only. For the determination of Vitamin C in Li-heparine plasma. Manual

Offered in the US by ALPCO - 26G Keewaydin Drive, Salem, NH Ph: (800)

Epinephrine/Norepinephrine ELISA Kit

Mouse IgM ELISA. Cat. No. KT-407 K-ASSAY. For the quantitative determination of IgM in mouse biological samples. For Research Use Only. 1 Rev.

Simultaneous determination of L-ascorbic acid and D-iso-ascorbic acid (erythorbic acid) in wine by HPLC and UV-detection (Resolution Oeno 11/2008)

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

Albumin ELISA Kit. Albumin ELISA Kit. Zur in vitro Bestimmung des Albumin in Urin und Stuhl

IgM ELISA. For the quantitative determination of IgM in human serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.

HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

HBV Quantitative Real Time PCR Kit

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

Mouse Insulin ELISA. For the quantitative determination of insulin in mouse serum and plasma

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS

Rat Creatine Kinase MB isoenzyme,ck-mb ELISA Kit

EUROPEAN COMMISSION DIRECTORATE-GENERAL TAXATION AND CUSTOMS UNION TAX POLICY Excise duties and transport, environment and energy taxes

Opiates in Urine by SAMHSA GC/MS

SIMULTANEOUS DETERMINATION OF NALTREXONE AND 6- -NALTREXOL IN SERUM BY HPLC

Hydrogen Peroxide Cell-Based Assay Kit

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

Inc. Wuhan. Quantity Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4 Standard (liquid) 2

Dengue IgM ELISA. For the quantitative determination of IgM-class antibodies to Dengue Virus in serum.

Standard Mixture. TOF/TOF Calibration Mixture. Calibration Mixture 1 (Cal Mix 1, 1:10) Calibration Mixture 1 (Cal Mix 1, 1:100)

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Determination of Caffeine in Beverages HPLC-1

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

VACUETTE RNAgard Blood Tubes BioMaxi Blood RNA Purification Kit. For the collection, preservation and purification of RNA from whole blood

RealLine HCV PCR Qualitative - Uni-Format

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS

Immunoglobulin E (IgE) concentrations in Human. Immunoglobulin E (IgE) Human ELISA Kit

Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database

CatCombi Research ELISA Kit

Respiration and Photosynthesis

United States Department of Agriculture Food Safety and Inspection Service, Office of Public Health Science

Cancer Antigen CA125 Human ELISA Kit

ELISA-VIDITEST-MICROCYSTIN LR Lot: XX

Amino Acid Analyzer L-8900

Revised 3 Oct rm (Vers. 16.1)

Application Sheet for Rivaroxaban (Xarelto ) Standard Range with. BIOPHEN Heparin LRT (#221011/221013) RUO

The Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen.

MATERIAL SAFETY DATA SHEET

Fast and Accurate Analysis of Vitamin D Metabolites Using Novel Chromatographic Selectivity and Sample Preparation

Appendix 5 Overview of requirements in English

Thrombin Generation Assay

Understanding quantitative blood alcohol testing in drunk driving cases.

Improved Method for the Analysis of 31 Drugs of Abuse in Oral Fluid samples using the Thomson extreme FV by LC-MS/MS

QUANTITATIVE AMINO ACID ANALYSIS. Aurélie Lolia Applications Manager, Biochrom Ltd

ANALYSIS OF FOOD AND NATURAL PRODUCTS LABORATORY EXERCISE

Mouse Creatine Kinase MB isoenzyme (CKMB) ELISA

Anti-Zona Pellucida Antibody Latex Agglutination Test

MagExtractor -Genome-

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis

Mouse krebs von den lungen 6 (KL-6) ELISA

UltraClean PCR Clean-Up Kit

1. PRODUCT AND COMPANY IDENTIFICATION

INSTRUCTIONS Edition AC

SUCRALOSE. White to off-white, practically odourless crystalline powder

QuickZyme Soluble Collagen Assay

Human Free Testosterone(F-TESTO) ELISA Kit

Aptima Specimen Transfer Kit

1. Identification of the substance/preparation and the company/undertaking

Canine creatine kinase MB isoenzyme (CK-MB)ELISA Kit

MATERIAL SAFETY DATA SHEET

experiment5 Understanding and applying the concept of limiting reagents. Learning how to perform a vacuum filtration.

Private Water Supplies Sampling Manual. A Field Guide

Blood Collection and Processing SOP

Parallel Circuits Charles Lang

MATERIAL SAFETY DATA SHEET

ab Free Testosterone ELISA Kit

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

Overview. Purpose. Methods. Results

UltraClean Forensic DNA Isolation Kit (Single Prep Format)

INMA LABORATORY MANUAL

Agilent High Sensitivity DNA Kit Guide

MTT Cell Proliferation Assay

Canine Creatine Kinase MM isoenzyme(ck-mm) ELISA. kit

Creatine Kinase (CK) Enzymatic Assay Kit Manual Catalog #:

Paper Chromatography: Separation and Identification of Five Metal Cations

Genomic DNA detection assay

Analysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column

UltraClean Soil DNA Isolation Kit

Safety Data Sheet. according to Regulation (EU) No. 1907/ Sulfuric Acid 1.0 N

LITHIUM CARBONATE, 1% AQUEOUS

ab Albumin Human ELISA Kit

ab Triiodothyronine (T3) ELISA Kit

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

SIMULTANEOUS DETERMINATION OF TELMISARTAN AND HYDROCHLOROTHIAZIDE IN TABLET DOSAGE FORM USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

GC/MS Analysis of Vanillin and Ethyl Vanillin in Distilled Spirits

Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

How To Test For Contamination In Large Volume Water

SIGMA-ALDRICH. Material Safety Data Sheet Version 4.0 Revision Date 02/27/2010 Print Date 08/25/2011

ORGANIC SAMPLE PREPARATION

MATERIAL SAFETY DATA SHEET

Register your instrument! MagSep Viral DNA/RNA Kit. Instructions for use

Transcription:

Package Insert Ubiquinone (Coenzyme Q 10 ) HPLC Assay 100 Tests For Research Use Only. Not for use in diagnostic procedures. v. 1.0 Eagle Biosciences, Inc. 20A Northwest Blvd., Suite 112, Nashua, NH 03063 Phone: 866-419-2019 Fax: 617-419-1110

1. Intended purpose The Eagle Biosciences Ubiquinone (Coenzyme Q 10 ) HPLC Assay kit is intended for the quantitative determination of ubiquinone (coenzyme Q10) in plasma, serum and EDTAblood. The Ubiquinone (Coenzyme Q 10 ) HPLC Assay kit is for research use only and should not be used for diagnostic procedures. 2. Introduction Ubiquinone is a coenzyme of every cell in the body. Ubiquinone is made up by a chinonic ring and an isoprenic side chain. In humans ubiquinone can be synthesized and taken up by nutrition. Ubiquinone has two different physiological functions. 1.) Component of the energy metabolism During the reduction of oxygen in the oxidative phosphorylation, electrons are transferred from NADPH to oxygen via 6 different redox systems. Ubiquinone is the less abundant redox system in the membrane of the mitochondria. Because of the low amount it is the speed controlling redox-system in the energy metabolism. Normally the amount of ubiquinone is sufficient, but with growing age and exposure to sunlight it is reduced to 50 %. 2.) Radical scavenger Ubiquinone has a high amount of carbon double bonds and therefore a higher potential of reduction than either vitamin C or vitamin E. Thereby it is the first line of defense against free radicals. Even when other antioxidants are inert, coenzyme Q10 reacts fast and sensitive against free radicals. Therefore ubiquinone is an optimal stabilizer of the ion channels of the membranes. The Eagle Biosciences Ubiquinone (Coenzyme Q 10 ) HPLC Assay kit makes it possible to determine ubiquinone in an easy, fast and precise method. The Ubiquinone (Coenzyme Q 10 ) HPLC Assay kit includes all reagents ready to use for preparation and separation of the samples with exception of the column (IC1700rp) and the controls (IC1700ko). Both can be supplied by Eagle Biosciences. Besides the complete test kit, it is possible to order all components separately. Please request our single component price list. Ubiquinone (Coenzyme Q10) HPLC Assay 2/8

3. Warnings and precautions All reagents of this Ubiquinone (Coenzyme Q 10 ) HPLC Assay kit are strictly intended for research use only. Test kit and column are concerted. Using alternative columns might cause in insufficient separation, resulting in false high results. The given test characteristics might not be fulfilled. Do not interchange the Ubiquinone (Coenzyme Q 10 ) HPLC Assay kit components from different lots. Calibrator and controls contain human plasma. It was tested and found negative for HBsAg, anti-hiv-1/2, and anti-hcv. No test can guarantee the absence of HBsAg or HIV, and so all human serum based reagents in this kit must be handled as though capable of transmitting infection. The internal standard, extraction solution and mobile phase contain organic solvents and have to be handled carefully. Organic solvents are highly flammable and toxic if inhaled or contact the skin. They should be handled with gloves, eye protection, and appropriate protective clothing in a hood. Any spill should be wiped out immediately with copious quantities of water. Do not breathe vapor and avoid inhalation. In case of an accident or indisposition contact immediately a physician. Wear disposable gloves while handling specimens or kit reagents and wash hands thoroughly afterwards. Do not pipette by mouth. Do not eat, drink, smoke or apply makeup in areas where specimens or kit reagents are handled. Reagents should not be used beyond the expiration date shown on kit label. Observe the guidelines for performing quality control in medical laboratories by assaying controls and/or pooled sera. During handling of all kit reagents, controls and serum samples observe the existing legal regulations. Ubiquinone (Coenzyme Q10) HPLC Assay 3/8

4. Materials Provided Article no. Component Designation Amount IC1700lm ELU Mobile phase 1000 ml IC1700ka CAL Calibrator, (lyoph. 500 µl) 5 vial IC1700is IS Internal standard 110 ml IC1700re RECON Reconstitution solution 5 ml IC1700ex EXT Extraction solution 220 ml IC1700vl DIL Dilution solution 85 ml IC1700et ETHA Ethanol p.a. 20 ml 5. Additional Special Equipment 10 ml screw capped glass vials (Pyrex) Centrifuge Various pipettes HPLC with UV-detector HPLC column Ubiquinone (IC1700rp) Evaporation unit Vortex mixer 6. Reagent preparation Reconstitute the calibrator (CAL) in 0.5 ml reconstitution solution (RECON), divide the calibrator in several portions and store them at -20 C. The resuspended calibrator is stable for at least 14 days. Avoid repeated freeze-thaw circles. The concentration of ubiquinone might have minor changes from lot to lot. The dilution solution (DIL) might show crystallization during storage at 2-8 C. Before use re-dissolve the crystals at room temperature or at 37 C in a water bath. All other test reagents of the Ubiquinone (Coenzyme Q 10 ) HPLC Assay kit are stable at 2-8 C, up to the date of expiry stated on the label. Ubiquinone (Coenzyme Q10) HPLC Assay 4/8

7. Specimen EDTA-plasma, EDTA blood and serum could be used. The samples are stable in the dark at 2-8 C for 1 week. For longer time samples should be stored at -20 C. 8. Procedure Principal of the method For the determination of ubiquinone (coenzyme Q 10 ) a precipitation step which removes high molecular substances is performed first. The internal standard reduces the variation in the sample treatment. After centrifugation the supernatant is mixed with an extraction solution and transferred to the organic phase. The organic solvent is evaporated and the sample is re-suspended in ethanol p.a. and injected into the HPLC system. The isocratic separation via HPLC at 30 C using a reversed phase column needs 15 minutes. The chromatograms are recorded by a UV-detector. The quantification is performed by the delivered calibrator and the concentration is calculated by the internal standard method via integration of the peak areas resp. peak heights. Sample preparation 1. Pipette into 10 ml screw cap tubes: 200 µl sample, CAL or CTRL 800 µl DIL + (Important: During storage at 2-8 C crystallization might occur. Re-suspend the crystals at room temperature or at 37 C in a water bath before use) 2. Mix well on a vortex mixer (10 s). 3. Add 1 ml IS 4. Mix well on a vortex mixer (10 s). 5. Add 2 ml EXTR 6. Mix for 2 min on a vortex mixer and centrifuge for 10 min at 3000 g 7. Remove 1.5 ml from the upper layer and evaporate to dryness. 8. Resuspend the residue in 150 µl ETHA 9. Inject 50 µl of the re-suspended sample into the HPLC-system Ubiquinone (Coenzyme Q10) HPLC Assay 5/8

Ubichinon IS Volts Chromatographic settings Column material: Bischoff Prontosil AQ, 5 µm Column dimension: 125 mm x 4 mm Flow rate: 0.8-1.2 ml/min UV-detection: 275 nm Injection volume: 100 µl Running time: 15 min Temperature: 30 C Treatment of the HPLC-column The column is left in mobile phase after analysis. Before use, equilibrate the system with approx. 20 ml mobile phase (ELU) (1 ml/min). 9. Calculation of analytical results Calculation peak area patient concentration of peak area IS patient the standard * F concentration patient sample F Peak area ISof the calibrator Peak area analyte of the calibrator Typical chromatogram 6 5 4 3 2 1 0-1 0 2 4 6 8 10 12 14 Minutes Ubiquinone (Coenzyme Q10) HPLC Assay 6/8

10. Internal quality control Reference intervals EDTA-plasma: 0.8 1.4 µg/ml We recommend that each laboratory develop their own normal range. The values mentioned above are only for orientation and can deviate from other published data. Mortensen S. A. et al: (1997) Molec.Aspects Med. 18:137-144 11. Validation data Precision and reproducibility Intra-Assay CV: 2.1 % (0.52 µg/ml) [n = 6] 0.6 % (1.23 µg/ml) [n = 6] Inter-Assay CV: 6.0 % (0.50 ng/ml) [n = 6] 6.2 % (1.17 µg/ml) [n = 6] Linearity Detection limit Recovery 12. Disposal up to 20 µg/ml 0.02 µg/ml 98.4 % The mobile phase (ELU), extraction solution (EXTR), internal standard (IS), and ethanol p.a. (ETHA) must be disposed as non-halogenated solvent. Please refer to the appropriate national guidelines. Ubiquinone (Coenzyme Q10) HPLC Assay 7/8

13. Troubleshooting Problem Possible reason Solution No signal No or defect connection to Check signal cord and evaluation system connection Detector lamp is altered Change lamp No peaks Injector is congested Check Injector Double peaks Dead volume in fittings and / or column Renew fittings and / or column Contaminating peaks Injector dirty Clean injector Contamination at the head of the column Change direction of the column and rinse for 30 min at low flow rate (0.2 ml/min) with mobile phase Air in the system Degas pump Autosampler vials contaminated Use new vials or clean them with methanol Broad peaks, tailing Precolumn / column exhausted Use new precolumn / column Variable retention times Drift in temperature Use a column oven Pump delivers imprecise Check pump, degas the system System is not in steady state yet Rinse system mobile phase for 15 min Baseline is drifting Detector lamp did not Wait reach working temperature yet Detector lamp is too old Renew lamp Continue baseline is drifting System is not in steady state yet Rinse system mobile phase for 15 min Pump delivers imprecise Check pump, degas the system Baseline is not smooth Pump delivers imprecise Check pump, degas the system Detector flowcell is dirty Clean flow cell 15. Literature references Mortensen S. A. et al: (1997) Molec.Aspects Med. 18:137-144 For further information about this kit, its application or the procedures in this insert, please contact the Technical Service Team at Eagle Biosciences, Inc. at info@eaglebio.com or at 866-411-8023. Ubiquinone (Coenzyme Q10) HPLC Assay 8/8