INSTRUCTION MANUAL. Thanks for purchasing our air compressor and please read this

Similar documents
PC1130 Electric Air Compressor

PC1131 Electric Air Compressor

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL

accidents which arise due to nonobservance and the safety information herein.

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS

National- Spencer Inc.

SHHH AIR COMPRESSOR Model Nos. SHHH2 - SHHH2/9 - SHHH3/9 - SHH3/24

2 HP / 4 GALLON AIR COMPRESSOR OWNER'S MANUAL

SHOT BLAST CABINET MODEL NO: CSB20B

FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS

Operators manual Basic water heater

OPERATING & MAINTENANCE AIR COMPRESSOR RANGER 35 INSTRUCTIONS. Part No:

User Guide. Bagless Cylinder White. Get Cleaning... vax.co.uk. Vax Careline: (UK) (ROI) White series

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

ENGINE FUEL FUEL FILTER... FUEL HEATER... INJECTOR... SUPPLY PUMP... COMMON RAIL... FUEL PRESSURE LIMITTER...

Operating Instructions Split System Air Conditioner

Dehumidifier Users manual. For Models: DH45S DH65S

ALL IN ONE. Heat Pump Water Heater

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT

GF SERIES 1-TANK/2-TANK ELECTRIC FRYER USER S MANUAL

Vacuum. How It Relates to Refrigeration And Air Conditioning Service

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

Instruction manual for Firstline FCS12000CH

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Instructions For SF 6 Refill Kit

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

SunMaxx Solar Filling Station Operating Instructions

Model 1210C Battery Powered Pump Shown. Description

Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Get Cleaning... User Guide Vax Careline: (UK) (ROI) Multifunction. vax.co.uk Series. What s your Vax model number?

Portable Air Conditioner

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

AIR-CONDITIONER SPLIT TYPE

Multi System. 16 SEER, Inverter System. 9,000 to 18,000 BTU/Hr. Single Split

COMPRESSED AIR DRYER

Wilo SP Series Submersible Sump Pumps ECS. ECS ECS ECS Installation and operating instructions

HPU14M-DS 2013 Daniels Manufacturing Corp., All Rights Reserved Page 1 of 17 REV. C 7/2013

tire inflator with pressure gauge

Your safety and the safety of others are very important.

- 2 - IMPORTANT SAFETY REMINDERS

Atlas Copco Stationary air compressors

MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial #

Vacuum chucking. MDAE Woodturning Center Course Number

Draining and filling cooling system

Please read operating instructions carefully before use and keep for further reference.

PORTABLE AIR CONDITIONER

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

OWNERS MANUAL FOR CORDLESS INFLATOR AIR260

ACCUMULATOR INSTALLATION

Hydraulic Air Riveter. Operation Manual RC197 RC198. Recommend for mass production line industrial area. Page 1

Compressor Service & Maintenance Manual

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español

DIGITAL MINI COMPRESSOR

Espresso coffee grinder

! WARNING. Before using product, read and understand instructions.

12-Volt 10-Amp Regulated Power Supply

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

ULTRA QUIET & OIL FREE

SERVICE MANUAL Order No.WH0911S001V0

PANTHER OPERATING & MAINTENANCE INSTRUCTIONS

CARING FOR YOUR WATER HEATER

Dehumidifier D 850E. - Instruction manual version 02

CG PTFE Diaphragm Liquid Transfer Pump

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800) Internet Address:

SILENT AIR COMPRESSOR

ULTRA QUIET & OIL FREE

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II

Hydraulic control unit series

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

Part I - Installation

Universal Adjustable Fuel Pressure Regulator

Get Cleaning... User Guide Vax Careline: (UK) (ROI) Carpet Washer. vax.co.uk. Rapide Ultra series

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19

Hydraulic Control Solutions

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

PORTABLE AIR CONDITIONER

ALMATEC Series CX CX 10 CX 130

Not required for most applications Not required for most applications High pressure ( provided) High pressure ( provided)

UNITOR VACUUM cleaners

Vision Engravers and Routers PRE-Installation Guide Vision Engraving & Routing Systems

Operating Manual. Rotary Drum Filter. Technology You Can Afford. Quality You Can Trust. Model: KC10 KC15 KC30 KC60

Kompressoren. Adsorption Dryer AD

Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR İ-COLD Rev. 00

SQUARE D INDUSTRIAL CONTROL PRODUCTS

Transcription:

INSTRUCTION MANUAL AIRBRUSH COMPRESSOR AS18-2 Thanks for purchasing our air compressor and please read this instruction manual carefully and thoroughly before operating the air compressor to receive optimum results.

1. Features & Functions: Features: Air pressure gauge; Air filter; Pressure adjustable. Piston type: Oil-free. It can start with pressure, continuous working, powerful. Thermally protected. Low Noise: 62db. Auto-start and auto-stop function. 2. Data Sheet: Type: Single Cylinder Piston Compressor Power: 1/6HP Speed: 1450/1700 r.p.m Air Flow: 20~23L/Min Auto-stop at the 4 Bar(57Psi), and Auto re-start from the 3 Bar(43Psi) Pressure adjust range: 0~4BAR Suitable for airbrush with nozzle size: 0.2~1.0MM Net Weight: 3.6KG Dimension: 275 140 220mm 2

3. Operation directory: 1. Usually the outlet thread size of our air compressor is 1/8 BSP. If you need the 1/4 BSP or other NPT screw thread, you may get the other adapters to fix the outlet, then you can connect with different air hoses. 2. The original air hose have rubber airproof inside; the user can make the airtight by hand, and get good performance. If the air hose is not the original, usually the air hose and air compressor cannot be well airproof. However, 100% airtight is only effective for auto stop function air compressor. Seal thread tape can be used to prevent leakage. This elastic tape is available in all stores selling sanitary products. 3. Connect the air compressor, air hose and airbrush (or other air tools), plug into the mains supply, turn on the switch, then the air compressor will start work. The press gauge will show the max pressure, and you can adjust the working pressure by adjusting the pressure adjustor. 4. Checking the air leakage. Please do not use any air tools before the compressor reach the maximum pressure and observe whether it will be auto-stop. If the compressor will not be auto-stop, please turn off the switch, then check the index on pressure gauge, if it is very steady, means the airtight is very good; While the index decline down quickly, it means there has the air leakage in the area of the connection. Please check and make it airtight, because any small leakage will affect the performance of the compressor. (It may lead to frequently auto-stop and auto-start). 5. The difference between maximum pressure and working pressure. The compressor s maximum pressure is the highest pressure it can build up, and the working pressure is the one shown on the pressure gauge When the connected airbrush is opened. Apparently, the working pressure is the constant pressure the compressor can maintain during airbrushing. The level of this working pressure depends on the nozzle diameter of the airbrush to which it is connected; the larger the nozzle diameter, the bigger the amount of air which can escape and the lower the compressor s working pressure. 6. The bottom of the regulator & filter is the water release valve, and users can open the valve to release the water or moisture at any time. 3

4. Notice: 1. The users should choose the right air compressor with suitable air flow and pressure according to the actual work requirement. 2. Before connecting the compressor, check the main voltage compatible with the electrical characteristics of the motor. 3. Please follow local electrical rules, and safety rules. And use the socket which must be earthing. 4. Never leave the appliance exposed to dust, acids, vapors, explosive or flammable gasses or atmospheric agents (rain, sun, fog, snow). 5. The vacuum pump must be used in suitable environments (well-ventilated, with an ambient temperature between +5 and +40 ) 6. Never use the appliance in your bare feet or wet feet, as well as the wet hand. 7. Never allow the children to touch the working machine or insert the stick into the machine. It will cause the danger of scald or get an electric shock. 8. Do not open or tamper with any part of the compressor. Contact an authorized Service Center. 4

5. Operation of Regulator & Filter Pressure regulator Pressure Gauge Water Release Valve Type: AFR-2000 Characteristic: The AFR-2000 is an in-line low pressure regulator with a 100 P.S.I gauge and moisture trap. This regulator gives user control of operating pressure as well as assisting in furnishing clean, dry and regulated air. Regulators must only be used as instruction and warnings specify. Operation: 1. The gauge reflect the working pressure of the air tools. 2. Pull the Pressure regulator up; turn clockwise to increase the pressure; turn counter-clockwise to reduce the pressure. 3. Turn the pressure regulator to get the right working pressure needed, and fix it. Do not turn the button when it can not be adjusted. 4. Pull the button water-release valve to release the water. 5

6. SPARE PART LIST: 6

7 Air compressor structure a.power plug b.power switch c.handle d.pressure regulator e.pressure gauge f.connection g.air filter 7