NSTALLATI 866)

Similar documents
1/3 HP Submersible Sump Pump with Vertical Float Switch

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Instruction Manual. Ultrasonic Cleaning Tank. Advanced Ceramics Technology (M) Sdn. Bhd A Crest Group Inc. Company

POOL SUNSHINE IONIZER MODELS SPD, SPD2 AND SPS INSTALLATION INSTRUCTIONS

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

MINI-BRUTE II HOT WATER POWER WASHER MODEL# MBII

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...

Troubleshooting Your Refrigerator

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

ClearView 100. Instruction Manual

Hydraulic Trouble Shooting

OPERATING INSTRUCTIONS. Shortening Filter Model No. 99-A, 102-A, & 107-A Series LIMITED WARRANTY PRODUCT SPECIFICATION

Rules for Safe Operation

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps

TABLE OF CONTENTS. ALTRA Series Operator Manual

WARMER or COOKER/WARMER

Panel Mounted Air Conditioners by Dantherm, Inc.

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

123 Industrial Loop Road Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

KLE-115U Single Rack Undercounter Configuration Instruction Manual

MODEL INSTALLATION INSTRUCTIONS

SOLAR PV SYSTEM MAINTENANCE GUIDE

Wilo SP Series Submersible Sump Pumps ECS. ECS ECS ECS Installation and operating instructions

Installation & Operation

Safety, Operation and Maintenance Manual with Parts List

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

Warranties All Products. Revised: 8/1/15 7 Pages

Electric Water Heater

SF15K SF05KSS, SF10KSS

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

The Storm 20-Gallon Wet/Dry Vac

Chapter 7 Hydraulic System Troubleshooting

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

MAINTENANCE OF SMALL WATER SUPPLY, SANITATION AND IRRIGATION SCHEMES

SunMaxx Solar Filling Station Operating Instructions

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

Read This First! OWNER S GUIDE

Dehumidifier Users manual. For Models: DH45S DH65S

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Please also see 10 golden rules for correct Saniflo installation on

IMPORTANT SAFETY RULES TO FOLLOW

Support Cleaning Apparatus. Operation, Cleaning, & Safety Manual

HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

MODEL NO. QWIK JON 100/101/102 SYSTEMS DATE CODE: INSTALLATION INSTRUCTIONS DATE INSTALLED: PREINSTALLATION CHECKLIST

Operating Instructions Split System Air Conditioner

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075

Central Air Conditioner

Convection Ovens. BX Classic. Models BX4 / FG 189C, BX / FG 158C, BX10 / FG 180C. Operator's Manual

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

Frequently Asked Questions Generators

OPERATION & MAINTENANCE MANUAL

3 WATT LED SPOTLIGHT Model No. SLM

Operators Manual. Use and Care Instructions Electric Models, SteamCraft Ultra 3, 5, 10. Series: 21CET8, 21CET16, 24CEA10. Part No. CET-OPM Rev A 1/01

100 Series Maxi Internal Filters. Instruction Manual

Light Duty Commercial Electric Water Heater

SENTRA SERIES WATER UNITS. 30 to 300 F Process Temperatures. 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 10 to 34 KW Stainless Steel Heaters

Wine Cooler with Thermo-Electric Cooling & Heating Technology

Oil and Coolant Circulating Heating System. Model - OCSM

USER S MANUAL HSC-24A

HOW TO GET TANKS & TOTES CLEANER IN LESS TIME & LOWER COSTS

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

Nest Learning Thermostat Installation Guide. Installation step-by-step


INSTALLATION and OPERATION RANGE BALL CONVEYOR MODEL NO: BC-001AN

Emergency Showers and Eyewashes Mike Adkins Wednesday, October 31, 10:00-11:1511:15 a.m.

Optimizing Tank Cleaning Operations

Die-Cast Metal, Motion- Activated Post Light

Ceramic Glass Electric Galley Ranges

Installation Manual. Features SMART SWITCH OCCUPANCY SENSOR. Maximum Energy savings

Bottom Loading Water Dispenser

UNITOR ULTRASONIC cleaning

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Use and Care Manual. Model CPA12KH AIR CONDITIONER

SWIMMING POOL HEAT PUMP

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

PAPER SHREDDER PRS-F-01 USER MANUAL

Line to Refrigerator Ice/Water Dispenser

, User s Manual

Customer Support

15GAL STEEL OIL DRAIN WITH 110V PUMP

SERIES VOLT ELECTRIC INSTANTANEOUS WATER HEATER FOR EMERGENCY SAFTEY EQUIPMENT INSTALLATION AND OWNERS MANUAL REQUIRED MANTENANCE

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

Select Radiators Installation Guide

ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

WINTERIZING YOUR HOME PLUMBING AT BLUE RIDGE SHORES

Heat Pump Water Heater IOM Manual

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

ATS Overhead Table Shelf System INSTRUCTION MANUAL

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Anode Rods, Cathodic Protection and the Porcelain (glass) Lining

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

Transcription:

I NSTALLATI ON & OPERATI ON MANUAL At l asswc500&swc7 50 Spr aywas hcabi net At l asaut omot i v ee qui pment www. at l as aut oequi pment. com ( 866)8982604

2 Table of Contents Product specifications...3 Introduction...5 Installation...5 Detergent Selection...5 Operation...6 Initial Start-Up Procedure...7 Solution Disposal...7 Maintenance...8 Warranty...8 Maintenance Checklist...9 Troubleshooting...10 Safety is a critical factor in the design of spray wash cabinets. The best program starts with a safety-conscious operator. The information highlighted in this bulletin describes operating practices for the benefit of the workers who will use our equipment in their daily jobs. Comments from users are appreciated.

3 Product Specifications (1) Model SWC-500 SWC-750 Overall Height 66 /1676mm 78 /1981mm Inside Height 42 /1067mm 54 /1372mm Inside Width 32 /813mm 32 /813mm Turntable Diameter 30 /762mm 30 /762mm Floor Space 44 43 /1118mm 1092mm 44 43 /1118mm 1092mm Load Capacity 1,000lbs/454kg 1,000lbs/454kg Stainless Steel Nozzles 19 22 Water Temperature 135-175 Fahrenheit 135-175 Fahrenheit Pump Max working pressure 28 PSI/175KPA 38 PSI/265KPA Pump Max Flow 43GPM 68GPM Electric Heater 6KW 6KW Wash Cycle timer 0-60Minutes 0-60Minutes Oil Skimmer Cycle Timer 0-15Minutes 0-15Minutes Tank Capacity 50Gallons 53Gallons Stainless Steel Water Pump Standard Standard Turntable Friction-Drive System Standard Standard Turntable Sprocket-Drive System None None Removable Tank Screen Standard Standard Stainless Oil Skimmer Standard Standard Small Parts Basket Standard Standard Removable Turntable Extension Standard Standard Removable Parts Tree Standard Standard Heavy Duty Caster Standard Standard Steel Cabinet Yes Yes Shipping Weight 730lb/330kg 930lb/420kg Shipping Volume 2.3 M 3 2.7M 3 Packaging Steel Pallet and Carton Steel Pallet and Carton Motor 1.5HP, 220V AC, 1PH 60HZ 3HP, 220V AC, 1PH 60HZ Power Requirement 220V SINGLE PHASE 60HZ 220V SINGLE PHASE 60HZ

4 Product Specifications (2) Model SWC-500SC SWC-750SC Overall Height 66 /1676mm 78 /1981mm Inside Height 42 /1067mm 54 /1372mm Inside Width 32 /813mm 32 /813mm Turntable Diameter 30 /762mm 30 /762mm Floor Space 44 43 /1118mm 1092mm 44 43 /1118mm 1092mm Load Capacity 1,000lbs/454kg 1,000lbs/454kg Stainless Steel Nozzles 19 22 Water Temperature 135-175 Fahrenheit 135-175 Fahrenheit Pump Max working pressure 28 PSI/175KPA 38 PSI/265KPA Pump Max Flow 43GPM 68GPM Electric Heater 6KW 6KW Wash Cycle timer 0-60Minutes 0-60Minutes Oil Skimmer Cycle Timer 0-15Minutes 0-15Minutes Tank Capacity 50Gallons 53Gallons Stainless Steel Water Pump Standard Standard Turntable Friction-Drive System Standard Standard Turntable Sprocket-Drive System None None Removable Tank Screen Standard Standard Stainless Oil Skimmer Standard Standard Small Parts Basket Standard Standard Removable Turntable Extension Standard Standard Removable Parts Tree Standard Standard Heavy Duty Caster Standard Standard Steel Cabinet Yes Yes Shipping Weight 730lb/330kg 930lb/420kg Shipping Volume 2.3 M 3 2.7M 3 Packaging Steel Pallet and Carton Steel Pallet and Carton Motor 1.5HP, 220V AC, 1PH 60HZ 3HP, 220V AC, 1PH 60HZ Power Requirement 220V SINGLE PHASE 60HZ 220V SINGLE PHASE 60HZ

5 Introduction The spray wash cabinet is designed to clean parts with a re-circulated detergent and water solution. The spray wash cabinet cleans with a combination of temperature, pressure, and the chemical action of the detergent. The spray wash cabinet includes an oil skimmer to prolong the life of the cleaning solution. The simple controls and operation are Designed to make the unit easy to operate. Installation LOCATION: When choosing a location for your spray wash cabinet, consider the following factors: The unit will generate steam. Make sure steam will have no adverse affects in the area surrounding the machine. Everyday use will result in liquid Spilling on the floor around the machine. Consider the use of traction mats and avoid placing the machine in high traffic areas. Allow access for service and utility connections. Place on a level site. ELECTRICAL: All electrical requirements are listed on the identification plate on the machine. The wiring diagram is inside the control box. Have your electrician install all suitable wiring and breaker/disconnect box necessary. Do not modify power cord installed on the unit. Once power is installed have your electrician check motors for proper rotation but do not turn on heating elements at this time. DRAIN CONNECTION: A 2 drain is located on the unit. Make sure you have ready access to a water source. You will be adding water to the tank on a daily basis. Detergent Selection Upon receiving your spray wash cabinet inspect for an visible damage from shipping. If any damage is found, make notation on your bill of lading and contact your freight carrier. Follow your freight carrier s procedure for handling damage. If no damage is found, remove all packaging material from the machine being careful not to damage the casters on the unit. Open the door to the unit and unpack all parts and packing materials inside. The manufacturer does not warranty this spray wash cabinet against rust. Rust will occur if the proper detergent is not used, if start-up procedure is not followed, or if your machine is not used on a regular basis. If not regularly used oil should be used on the inside of the machine. Rust can also occur if you use D.I.water for rinsing.

6 A detergent formulated for mild steel Meeting the following criteria should be met: The detergent must have rust inhibiting agents. The detergent should be strong Check water level before starting the enough to remove the contaminants, machine. The ideal water depth in the but not so strong that it attacks the holding tank is 8. Water should be even or metal substrate. just above the filter basket. Water level The detergent should only leave an should be checked daily. acceptable amount of residue on the parts. For new parts, you may need a To heat the solution in the tank, turn the detergent that is free rinsing. heat breaker to the on position. Allow at For use in spray wash cabinet, the least 1 hour for the solution to reach 140- detergent must be low foaming. 160 degrees F before first wash cycle. During daily operation the heating elements The manufacturer offers a line of detergents work automatically as needed. developed for use in spray wash cabinets. For information contact our sales department. When solution has reached proper If the parts are critical, it is the customer s temperature, turn all other breakers to the responsibility to perform any metallurgical tests. on position. Place parts on the wash rack making sure parts are placed to allow rotation of the wash rack. Small parts can be placed in wash baskets provided with the Operation machine. Close and latch the door and set the timer to start the wash cycle. Generally, The controls for the spray cabinet are as most wash cycles should be 15-20 minutes. follows: CIRCUIT BREAKERS: These are located on the back of the unit inside the circuit box. The circuit breakers are used to power on/off the machine. CYCLE TIMER: located on the side of The oil skimmer is not designed for constant The cabinet above the door latch. Used use. When floating oil is 1/4 to 1/2 deep, or To control the wash cycle. When oil starts to impede cleaning, operate OIL SKIMMER: Controlled by a toggle the skimmer. Before operating oil skimmer switch located on junction box behind place a collection container at the oil the skimmer wheel. Skimmer to collect material skimmed. THERMOSTAT: Located inside the Follow all regulations for disposal of back cover of the machine. Used to skimmed material. control the water temperature in the tank. This should be set to a temperature of At the end of daily operations turn off all 140-160 degrees F. power to the spray wash cabinet. SAFETY SWITCH: Prevents pump From operating when the door is open.

7 Initial Start-Up Procedure 13. Run the spray wash cabinet for at least 1-hour of wash cycles for the next two days. 14. Adjust oil skimmer flanges to make light contact with the skimmer wheel. Use care to not put excess strain on the oil skimmer motor. For first time use, follow the following procedure: Your machine is now ready for daily operation. The more wash cycles you run, the more the cabinet is coated with rust inhibitors. If you have any questions about start up or installation of your machine contact your provider. Solution Disposal 1. Make sure electrical power to the Machine is off. Protect your environment an protect your 2. Verify that your electrician has done business from fines by handling your all necessary work. cleaning solution according to federal, state, 3. Verify heat and wash breakers are and local codes. According to federal In the off position. regulations, which states have to adopt as 4. Fill the tank with water. Add water minimum standards, the dirty cleaning until the water level is just above the solution in a spray wash cabinet is generally removable filter basket. not hazardous waste. 5. Verify thermostat is set between 140-160 degrees F. The two characteristics that you have to be 6. Turn on electrical power to the most concerned about are corrosivity and machine. Ep toxicity. Ask your detergent supplier is 7. Turn the heater breaker to the on the PH of your solution is greater than 12.5 position. and if so, how it can be neutralized. To 8. When the water temperature has check for Ep toxicity, you would need to reached the proper temperature, have a sample tested by a laboratory. add detergent following the detergent manufacture s directions. Assuming that your solution is not Pour the detergent directly into the hazardous, or that with minor treatment (e.g. Filter basket. adding acid) the solution can be made non- 9. Close and latch the door. Turn all hazardours, the EPA does not require special other breakers to the on position. storage, documentation, transportation, and Set the wash timer to run a 15- processing. Since your solution will have oils, minute wash cycle. however, you will probably not be able to 10. During the initial wash cycle, walk dump the solution in the sewage line (call around the machine and check for your sewage treatment facility) and you leaks. certainly can t dump the solution on the 11. At the end of wash cycle, open ground or in a storm drain. You can the door. separate the oil and solid contaminants from 12. If water was leaking around the door, the solution so that the cleaning solution can Adjust the direction of the spray last for an indefinite period. nozzles to spray away from the door.

8 Maintenance Do not allow the sludge accumulation in the tank to exceed a 1 depth. Otherwise, the sludge build-up could damage the heating element(s) and pump. Depending on the application, some businesses have to clean out the sludge weekly, while others can go months before cleaning out the tank. Since you can t see the sludge, clean out the tank within the first week of operation and develop an appropriate clean out schedule. The following procedure should be followed for sludge removal: Disconnect all power to the machine or make sure all breakers are in the off position. Remove the wash rack and filter basket from the machine. Using the drain, remove solution from the tank. You can save the solution for reuse. Scrape out the sludge through the filter basket opening being careful to not hit the heating element. Close the drain and install the filter Basket and wash rack. Fill tank with solution to proper level. Warranty Limited Warranty This warranty covers any defects in manufacturing on your spray wash cabinet. This warranty lasts one (1) year from the date of purchase. Coverage terminates if you sell or otherwise transfer the spray wash cabinet during the period of the warranty. Rust, or any problem that is caused by abuse, misuse, or an act of God is not covered in this warranty. The manufacturer should not be liable in either tort or contract for any loss or damage, direct, indirect, special, consequential, or incidental, arising out of the use or inability to use this product. Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations may not apply to you. If spray nozzles become clogged you may need to flush the spray tubes. Remove all pipe caps and bottom spray nozzles and run a maximum of 60 second wash cycle. Follow daily and monthly maintenance guidelines included in this manual.

9 Maintenance Checklist DAILY Check water level. Fill to just above the filter basket. Clean any clogged spray nozzles. Clean up any spilled solution in surrounding area. Clean out removable filter basket. Adjust detergent concentration as needed. Run oil skimmer as needed Clean sludge from tank as needed MONTHLY Check hoses for leaks or visible damage. Replace if necessary. Make sure all components are in good operating condition. Inspect all electrical wiring. Inspect pump for leaks. Inspect wash tray and friction drive wheel. Replace if necessary. Remove sludge from holding tank. Notes:

10 Troubleshooting Problem Probable Cause Possible Remedy Unit not working Pump motor not operating Pump motor operates but has little or no pressure Solution won t get hot Poor cleaning Wash table not turning Rust inside cabinet Solution is foaming Check fuse or circuit breaker Check for correct voltage Wiring connections Pump breaker off Broken wash timer Broken door safety switch Wiring connections Bad motor starter Pump is broken Water level is too low Pump is rotating backwards Pump is broken Solution is foaming Spray manifolds or filters are clogged Thermostat not set an correct temperature Broken heating element Broken thermostat Wiring connections Incorrect detergent Low detergent concentration Hard water Clogged nozzles Solution is too dirty Incorrect solution temperature Low pump output Pressure spring missing or broken Worn friction drive wheel Wiring connections Motor windings burned out Wrong detergent Did not follow start up procedure Machine used too infrequently Wrong detergent Started wash cycle when solution was cold. Concentration too low Replace blown fuse or reset circuit breaker Supply correct voltage to unit Repair and insulate all connections Turn on breaker for pump Replace timer Replace switch Repair and insulate connections Consult electrician Replace pump Fill water to proper level Consult an electrician Replace pump see below clean out Adjust thermostat Replace heating element Replace thermostat Repair and insulate connections Use detergent designed for spray wash cabinet. Adjust detergent level Use a water softener Clean spray nozzles Run oil skimmer or change solution Adjust thermostat See below Replace spring Replace friction drive wheel Repair and insulate connections Replace motor Remove rust use detergent with rust inhibitors Remove rust, and change solution using twice the normal detergent level. Remove rust, oil the inside of the cabinet. Use low-foam detergent Allow proper time for solution to heat Adjust detergent concentration Add de-foamer

11