RS4 Whole House IAQ System

Similar documents
Robert McCabe Director, Health Care Solutions HTS Chicago. Improved Air Quality and Energy Efficiency through Air Handler Filtration System Upgrade

Make your home a healthier home

There are several types of air cleaning devices available, each designed to remove certain types of pollutants.

indoor Air quality products Air Filtration Ventilation Purification Humidification

Owner s Manual Model 5000 Safety, Operating and Maintenance Instructions

+by RGF A Guardian Air Purification System New Advanced Environmental Air Treatment System

Trane CleanEffects. Patented technology. Superior performance. READ ONLY

GENANO 4500 MEDICAL AIR PURIFICATION DEVICE

Uses No Chemicals. Ozone Reverts Back to Oxygen. Eliminates Odor Electronically. Operates Unattended. Retards Bacterial Growth. Rapid Removal of Odors

Installation Instructions WARNING: WARNING: WARNING: WARNING: WARNING:

Indoor Air Quality FILL YOUR HOME WITH AIR THAT IS AS CLEAN AS IT IS COMFORTABLE. READ ONLY

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

Improving Indoor Air Quality on a Tight Budget

REME HALO by RGF A Guardian Air Purification System New Advanced Environmental Air Treatment System

TOTALINE UV AIR PURIFIERS

AccuClean. For Air That s As clean READ ONLY

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

THE APPLICATION OF OZONE FOR AIR TREATMENT: CASE STUDY OF A BINGO HALL HVAC SYSTEM

Coway Air Purifier AP-1008DH

Installation Instructions

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES

Installation and Operating Manual Model F1800C Model F1800PG Model F1802C Model F1802PG Model F1806C Model F1806PG

Automotive Air Quality Sensors: industrial innovations to protect people s health

Cal Water 1961 Petra Lane, Placentia, CA (800) CAL-WATER (800) FAX: (714)

Introduction to Use of UV Light For the Control of Air Handler Contamination. What is UVGI or Ultraviolet Light?

The photoionization detector (PID) utilizes ultraviolet

Today, healthcare facilities must be prepared to face

Ultra-Violet Products Ltd 2066 W 11th Street, Upland, CA Unit 1, Trinity Hall Farm Estate

UV100A Ultraviolet Air Treatment System

THE LEADER IN PERFORMANCE INDOOR AIR QUALITY MEASUREMENTS

Changing Carpet Care Forever

Electrostatic or Electronic: Know the Facts By Robert P. Scaringe, P.E., Ph.D., ---President of Mainstream Engineering

Copyright Puradigm, LLC HVAC Owner s Manual

A. Air-Conditioning and Refrigeration Institute: 1. ARI Commercial and Industrial Air Filter Equipment.

Dehumidifier Users manual. For Models: DH45S DH65S

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

FTXS. Wall Mount Heat Pump or Cooling Only

12 Volt 30 Amp Digital Solar Charge Controller

floater imports DF169 ECO AIR COOLER EVAPORATIVE AIR COOLER WITH IONIZER USER S MANUAL

COWAY AIR PURIFIER SYSTEM. HEALTH HEALTH TECHNOLOGY ASSESSMENT SECTION (MaHTAS) SECTION 018/2011

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer

User s Manual Before using the inverter, you need to read and save the safety instructions.

FAMILY PROTECTION FROM WATERBORNE DISEASES

Ultraviolet Germicidal Lamps Owner s Manual MODELS 1910 & 1930

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

Indoor Air Quality Issues for Hotels

The Effect of Forced Air Cooling on Heat Sink Thermal Ratings

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Performance 17 Two-Stage Air Conditioner with Puron Refrigerant

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Power consumption (kw)

Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075

warm air for the healthiest, most comfortable home environment possible. This occurs with a system efficiency of up to 90%.

Sap Steady UV Unit for Maple Sap

Installer s Guide WARNING: 18-GJ11D1-2. Ultraviolet (UV-C) Lamp Kit for 2-5 Ton Air Handlers HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING

ECO SENSORS, INC. OZONE SENSOR AND MONITOR

Fax: (888) Pan Treatments Page 01

Instructions. UV UltraVac_IM_B.indd 1 28/09/ :23

3M Personal Safety Division E C O R D. Cartridge. Filter. and. Guide. User Information to Help Optimize Protection

12-Volt 10-Amp Regulated Power Supply

condensation mould high humidity

3M Personal Safety Division 3M Center, Building W-75 St. Paul, MN, USA

Reduction Test for particle decrease Reduction Test of LightAir ionizing air cleaner

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

Senses SV series industrial monitor user manual

Zehnder Focus 200. Ventilation device

Stenner Pump Chlorinator Installation & Start Up Guide

How To Use A Cdm250 Digital Multimeter

CAEN Automation Enclosures

AUTOMATIC HAND DRYERS

Intelli-Pro Air Purifier (Model: XJ-3800)

UV100E Ultraviolet System

Materials Needed: Time Needed: Adaptations: 2 flyswatters (optional) Vocabulary Definitions (below) Vocabulary Scramble Sheets (below)

Facility Requirements for the elan2 Office Liquid Nitrogen Generator

Owner's Manual Air-Purifier MK-B1000 Air Cleaning Expert 110V Model

13 Watt PORTABLE SOLAR POWER KIT

Installation and maintenance instructions. Danfoss Vent

APC Step-Down Transformer. User s Manual

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

Includes specifications for: Surface Cleaning & Mounting Hardware.

SALTER AIRE Plus COMPRESSOR Model 8350 / 8352 / Instruction Manual. Page 1 of 9

Instructions & Safety Information Models A220-20D and A220-20L Version 2

Installation Manual CLIFC Fan & Coil Variable Speed

Installation and Operating Instructions (for chargers shown below)

Air Quality Control Systems For Public & Shared Spaces

Hospital Idle Reduction: eliminating ambulance idling on the hospital campus. Harold Garabedian Energy & Environmental Analytics

Sun-Pure Air Purifier

Patient Manual. Oxygen Concentrator

Gas Condensing Boilers

CATALOGUE BIOSAFETY EQUIPMENT: UV CLEANER-RECIRCULATORS, DNA/RNA UV CLEANER BOXES, LAMINAR FLOW CABINET, MULTI-CLEANER XL

G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method

Dehumidifier D 850E. - Instruction manual version 02

Remediation of Water-Based Drilling Fluids and Cleaning of Cuttings

In-Line Filters and Coalescers with Automatic Drains

TIG INVERTER INSTRUCTION MANUAL

General Purpose Laminar Flow Cabinets, Horizontal and Vertical

Ductless Heat Pumps for Passive Houses

Class II Type B2 Laminar Flow Biological Safety Cabinets at Ordering Criteria for the National Institutes of Health

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Transcription:

RS4 Whole House IAQ System Contaminant Control Electronic Polarized Media for control of ultrafine particles Activated Carbon Matrix for odor and gas phase contaminant control Series2 Ultraviolet Germicidal System for control of airborne viruses, biologicals, germs and gases Design Flexibility 1400 CFM, Right Angle left or right Flow-thru side to side or top to bottom One model, easy field conversion Adjustable 24 gauge flanges for multiple duct sizes Knockouts for Models 407 high output UVC system Heavy Duty 16-20 gauge steel cabinet Now there is one whole-house air cleaning system that addresses all three types of airborne contaminants quietly and efficiently. The Dynamic RS-4 Whole House IAQ System applies the latest proven air purification technologies that work with the central heating and cooling system to provide clean, healthy air throughout the home. For Fine Particles - Dynamic Polarized Media Electronic Air Cleaner 97% efficient at.3 microns and smaller, the Dynamic Polarized Media Electronic Air Cleaner provides ultra efficient particulate removal. The Dynamic Polarized Media Air Cleaner removes dangerous submicron particles and other contaminants that other filters miss, including bacteria, odors, and smoke. For Gas Phase Contaminants - Dynamic Activated Carbon Matrix The Dynamic Activated Carbon Matrix (ACM) brings the power of industrial strength activated carbon to your home. The Dynamic ACM uses advanced composites and extrusion technologies to provide the effectiveness of an industrial-strength activated carbon system. Dynamic ACM is suitable for high airflow, high temperatures, and high humidity. For Germs and Viruses - Dynamic Series2 UVC Germicidal Lamp UVC efficiency is a function of lamp microwatt output. The Dynamic 407H-16 and 407H-16-O3 (with activated Oxygen) Series2 UVC systems offer 180 microwatts and a dual lamp configuration for one of the highest output UVC systems available today. 1

Standard Features SAFE & QUIET OPERATION Airflows in any direction with no moving parts to wear out. High-efficiency polarized-media air cleaner runs on 24-volts that feeds a high voltage power supply producing 7,000 volts of DC output current. A high internal impedance makes it very safe and virtually short-circuit proof. No arcing like other electronic air cleaners. Does not produce charged particles that collect on clothes, walls and furnishings. EASY TO MAINTAIN Convenient front access. No washing of components required. The Activated Carbon Matrix will generally last two to three years, depending on household conditions such as the presence of pets and/or smokers. Systems utilizing the DYN-407H-16-O3 UV System with activated Oxygen can expect to extend carbon service life by up to 50%. Germicidal UV lamps are changed every two years (18000 hours). Media pads are generally changed every four (4) to eight (8) months, depending on household conditions. FLEXIBLE INSTALLATION Heavy 16-20 gauge galvanized steel, thermally-insulated cabinet. Block-off plates can be quickly repositioned for a fast install. Knock-outs for UV Air Purifier. Unsurpassed versatility with multiple configurations including right angle and flow through. Adjustable 1 flanged duct openings eliminate field transitions. Dynamic Series2 DYN-407H-16 and DYN-407H-16-O3 UV lamps, standard on some models, run on either 120VAC or 240VAC, 50/60 Hz. WARRANTY Limited Lifetime Warranty on electronic components. UVC lamps are warranted against defects for two (2) years. Electronic Air Cleaning Effectiveness Dynamic Air Cleaners use electronic polarized-media technology to provide maximum ozonefree air cleaning. Active electronic, polarized-media air cleaners use a safe, 24 volt current to establish a polarized electric field. Airborne particles pass through the field and adhere to the media. The air cleaner s efficiency increases as it loads, providing exceptionally high efficiency with air resistance much lower than passive filters. Dynamic Air Cleaners capture even the smallest sub-micron particles, in addition to airborne viruses, pathogens, and volatile organic compounds (VOCs). Dynamic Air Cleaners capture 97% of particles at.3 microns and continues trapping particles much smaller in size. These are the particles that are otherwise absorbed into our bloodstreams to trigger asthma attacks and allergy symptoms, in addition to more serious health issues. Maintenance is a breeze. Each Dynamic Air Cleaner uses a disposable replacement media pad which can be replaced in just minutes to keep your air cleaner running at peak efficiency. 2

Carbon Effectiveness Carbon effectiveness and longevity are functions of weight and contact time. More weight means more capacity for odor removal and a longer service life. One gram of activated carbon has 10,000 square feet of internal surface area. One pound of activated carbon has a surface area equal to about 125 acres. Based on the contaminants of concern and their concentration levels, the media life for Dynamic Carbon Matrix is predictable. In addition, the media can be engineered on a job-by-job basis to meet specific performance requirements such as static pressure drop, maximum face velocity and residence time. Common target contaminants include Hydrogen Sulfide, Chlorine, Sulfur Dioxide, Chlorine Dioxide and other acid gases and odors. Physical Properties Density 26.6 lb/ft3 Crush Strength 600 psi minimum Dust-free under normal operation Removal Capacity Hydrogen Sulfide 40% by weight Sulfur Dioxide 4% by weight Xylene 13% by weight Toluene 9% by weight The chart above shows removal of Xylene which has similar representative characteristics of vehicle exhaust emissions and common VOCs. Dynamic Carbon Matrix is engineered to deliver an 80.0% to 90.0% upstream/downstream removal. Electronic Air Cleaner (EAC) with Activated Carbon Matrix 3

Pressure Drop Air Cleaner AND Carbon Germicidal UVC Effectiveness The Dynamic 407H-16 Series2 Germicidal UV Air Purifier is a high output germicidal lamp that harnesses the energy of the sun s UVC rays to disrupt the DNA of living viruses, bacteria and other living airborne organisms so they can no longer reproduce. UVC is effective against viruses, bacteria, molds and mold spores, pollen, and other pathogens. The Dynamic 407H-16-O3 Air Purifier uses dual wavelength UVC and UVV that also controls germs and gases. Germicidal UVV is effective against odors and gas phase contaminants and oxidizes contaminants to CO2 and H2O. The 407H Air Purifier mounts to the RS4 cabinet to provide maximum wholehouse efficiency serving the entire living space. 4

Part Numbers & Accessories Description RS-4 IAQ System with EAC & ACM & UV RS-4 IAQ System with EAC & ACM & UVO3 RS-4 IAQ System with EAC + ACM RS-4 IAQ System with EAC + UV RS-4 IAQ System with EAC + UVO3 RS-4-IAQ System with EAC Only UV: 36W H LAMP 110/220/240V 16 for RS4 UV UV: 36W H LAMP 110/220/240V 16 for RS4 UVO3 RS-4 ACM Carbon Inserts (2-4 Years) RS-4 Media 4 Pack UV: UVC16HC Replacement Lamp 2YR 16 UV UV: UVC16HC Replacement Lamp 2YR 16 UVO3 RS-4 Flange Kit (Optional Additional) Plug-in Transformer 120VAC (for EAC) Part No. RS-4-ACM-407H-16 RS-4-ACM-407H-16-O3 RS-4-ACM RS-4-407H-16 RS-4-407H-16-O3 RS-4-1400 DYN-407H-16 DYN-407H-16-O3 RS-4-INSERTSET C4P-RS4 LSK-36-16 LSK-36-16-O3 RS-4-FLANGEKIT A412402 Optional Accessories & Features 240V power cord (part no.pc-240). 110Volt step-down transformer allows the air cleaner to be plugged directly into any standard wall outlet (part no A412402). Electrical (Air Cleaner) Electrical Input: Powerhead Output Voltage: Power Consumption: Powerhead Volt/Amps Draw: Ozone Generation: 24 VAC 7 kv (DC).95 Watts 1.45 VA None Dimensions Unit Weight EAC only 14 lbs (6.35 kg) Unit Weight EAC + Carbon 18 lbs (8.2 kg) Cabinet Dimensions 16-1/4"W x 25"H x 27"D (41.3 cm x 63.5 cm x 68.6 cm) Adjustable Top (or bottom) Flange 11 x 24 (28 cm x 61 cm) 12 x 24 (30.5 cm x 61 cm) 13 x 24 (33 cm x 61 cm) Adjustable Side Flange 14 x 24 (35.5 cm x 61 cm) 18 x 24 (46 cm x 61 cm) 15 x 24 (38 cm x 61 cm) 19 x 24 (48 cm x 61 cm) 16 x 24 (41 cm x 61 cm) 20 x 24 (51 cm x 61 cm) 17 x 24 (43 cm x 61 cm) 5

Front View Top & Bottom View Side View 6

Multiple Configurations for Installation Flexibility 7

Dynamic Air Quality Solutions P.O. Box 1258 Princeton, NJ 08542 Tel: (800) 578-7873 Fax (609) 924-8524 www.dynamicaqs.com Specifications are subject to change without notice. Dynamic and Dynamic Air Quality Solutions are registered trademarks of Environmental Dynamics Group, PO Box 1258, Princeton, NJ 08542 2014 EDG DYN-481 (9/14) 8