English translation prepared by CSTB - Original version in French language

Similar documents
(English language translation, the original version is in French language) 01/02/ /01/2018. Plan 1 & 2

(English language translation, the original version is in French language) Powers Throughbolt PTB-XL-ETA7-PRO 01/02/ /01/2018.

(English language translation, the original version is in French language) RAWL R-HPT

(English language translation, the original version is in French language) Hilti HSL-3

Europeiskt Tekniskt Godkännande European Technical Approval

(English language translation, the original version is in Czech language) DEWALT PTB-PRO. DeWalt Black-&-Decker Str Idstein Germany

HSL-3 Heavy duty anchor carbon steel. Anchor Fastening Technology Manual HSL-3. Heavy duty anchor. Version /

HUS-HR, CR Screw anchor, stainless steel

European Technical Approval ETA- 13/0056

Rakennustuotedirektiivin (89/106/EEC) artiklan 10, neuvoston direktiivi 21. joulukuuta 1988, mukaisesti notifioitu tuotehyväksyntälaitos EOTAN JÄSEN

Rakennustuotedirektiivin (89/106/EEC) artiklan 10, neuvoston direktiivi 21. joulukuuta 1988, mukaisesti notifioitu tuotehyväksyntälaitos EOTAN JÄSEN

Eurooppalainen tekninen hyväksyntä ETA-10/0280 European Technical Approval

European Technical Approval ETA-98/0001

Eurooppalainen tekninen hyväksyntä ETA 08/0173 European Technical Approval. Sormat S KA kiila ankkurit Sormat through bolt S KA

(English language translation, the original version is in French language) Chemical anchoring system WIT-200

Rakennustuotedirektiivin (89/106/EEC) artiklan 10, neuvoston direktiivi 21. joulukuuta 1988, mukaisesti notifioitu tuotehyväksyntälaitos EOTAN JÄSEN

HUS-HR, CR Screw anchor, stainless steel

HUS-V Screw anchor. HUS-V Screw anchor. Basic loading data (for a single anchor) Mean ultimate resistance

Hilti HIT-HY 150 MAX with rebar

Eurooppalainen tekninen hyväksyntä ETA 01/0003. Sormat Oy Harjutie 5 FIN Rusko. Sormat Oy Harjutie 5

HUS-A 6 / HUS-H 6 / HUS-I 6 / HUS-P 6 Screw anchor in precast prestressed hollow core slabs

European Technical Approval ETA-08/0121

(English language translation, the original version is in French language) Injection system Hilti HIT-HY 150 MAX

European Technical Assessment. ETA-02/0020 of 22 September English translation prepared by DIBt - Original version in German language

EUROPEAN ORGANISATION FOR TECHNICAL APPROVALS

HVU with HAS/HAS-E rod adhesive anchor

European Technical Assessment ETA-10/0153 of 10/06/2015

European Technical Approval ETA-06/0259

Hilti HIT-HY 200 with rebar

(English language translation, the original version is in French language) SPIT HIT M. Société SPIT Route de Lyon F BOURG-LES-VALENCE France

Hilti, Inc South 122 nd East Avenue Tulsa, OK

TZ WEDGE ANCHOR FOR CRACKED AND UNCRACKED CONCRETE

HUS-HR Stainless steel Concrete Screw A CE conformity. Corrosion resistance. European Technical Approval

HUS-H Screw Anchor. Technical data. Seismic design data. HUS-H Carbon steel screw anchor. HUS-H diameter 8, 10, 14. Seismic design data

(English language translation, the original version is in French language) Hilti HDA and HDA-R

Hilti KWIK HUS-EZ I (KH-EZ I) Internally Threaded Carbon Steel Screw Anchor

European Technical Approval ETA-07/0211

European Technical Approval ETA-11/0374

European Technical Approval ETA-01/0013

European Technical Approval ETA-12/0500

European Technical Approval ETA-10/0005

European Technical Approval ETA-98/0001

The following excerpt are pages from the North American Product Technical Guide, Volume 2: Anchor Fastening, Edition 16.

European Technical Approval ETA-09/0040

ICC-ES Evaluation Report

English translation prepared by DIBt Original version in German language

European Technical Approval ETA-10/0153

Hilti, Inc South 122 nd East Avenue Tulsa, OK

European Technical Approval ETA-08/0290

Technical Application Document. Hilti HIT-RE 500-SD

European Organisation for Technical Approvals Evropská organizace pro technické schvalování. TECHNICKÝ A ZKUŠEBNÍ ÚSTAV STAVEBNÍ PRAHA, s.p.

European Technical Approval ETA-08/0010

Submittal Information

English Version. Eurocode 2: Design of concrete structures - Part 4: Design of fastenings for use in concrete

7Čå.e.279(1Ì HEAVY DUTY ANCHOR

European Technical Approval ETA-13/0235

European Technical Approval ETA-07/0260

Ermächtigt u n d n o t i f i z i e r t gemäß Artikel 10 der Richtlinie des Rates vom 21. Dezember 1988 zur Angleichung

European Technical Assessment ETA-15/0652 of 27/10/2015

INSTRUCTIONS FOR USE

Injection System VMU. Injection System for non-cracked concrete and brickwork. Threaded Stud VMU-A for concrete and brickwork

European Technical Assessment ETA-15/0028 of 23/02/2015

PPM High-Strength Anchor Bolt

European Technical Approval ETA-04/0013

European Technical Approval ETA-10/0200

HPM Rebar Anchor Bolt. For bolted connections. Technical Manual. European Technical Approval ETA-02/0006. Version: Peikko Group 01/2015

European Technical Approval ETA-03/0039

European technical approval ETA-10/0460

Europeiskt Tekniskt Godkännande European Technical Approval

European Technical Approval ETA-09/0296

Operations and Instruction Manual Might Swivel - Part # Concrete and Steel Anchorage Connector ANSI Z ,000 lbs / 44kn

Design MEMO 60 Reinforcement design for TSS 102

CITY OF LOS ANGELES CALIFORNIA

European Organisation for Technical Approvals

Design MEMO 54a Reinforcement design for RVK 41

Bonded Anchors & Mechanical Anchors

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

Hilti HIT-V and HAS Threaded Rod and Hilti HIT-Z Anchor Rod

INTERIM ADVICE NOTE 104/15 IAN 104/15 THE ANCHORAGE OF POST- INSTALLED FASTENERS AND REINFORCING BARS IN CONCRETE

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

PART E SPECIFICATIONS

How to order: Please prefix the mbo part number or description with R239- example: R /014

for HACA fixed two-rail ladders with / without rear safety guard and fall arrest system

Page 1 of European Technical Approval ETA-12/0495

C E L CONSULTING A D I V I S I O N O F C O N S O L I D A T E D E N G I N E E R I N G FOR THE

European Technical Approval ETA-08/0266

ETA-07/0142. fischer drop-in anchor EA II. fischerwerke. No 305/2011.

HALFEN ANCHOR BOLT SYSTEMS Z-HGB 15-E CONCRETE

SMART PLUG TYPE BP AND LBP

European technical approval ETA-12/0208

Concrete Design Manual

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

Connection Solutions

Design and Construction of Cantilevered Reinforced Concrete Structures

Sealfire W1000 Compound. (2 references for the same product) Fire Stopping and Sealing Product: Penetration Seals

ANCHOR BOLTS FOR NUCLEAR POWER PLANT APPLICATIONS

(English language translation, the original version is in French language) KEPS 1327 avenue de la Houille Blanche CHAMBERY- FRANCE

Machine devices, jig devices

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

EJOT Spiralform. The thread formers for metal. EJOT The Quality Connection

Transcription:

Member of Centre Scientifique et Technique du Bâtiment 84 avenue Jean Jaurès CHAMPS-SUR-MARNE F-77447 Marne-la-Vallée Cedex 2 www.eota.eu Tél. : (33) 01 64 68 82 82 Fax : (33) 01 60 05 70 37 European Technical Assessment ETA-09/0317 of 18/07/2014 General Part - Original version in French language Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: Nom commercial Trade name Famille de produit Product family Titulaire Manufacturer Usine de fabrication e Manufacturing plants Cette evaluation contient: This Assessment contains Cheville métallique à expansion par vissage à couple contrôlé, de fixation dans le béton fissuré : diamètres M8, M10, M12, M16 et M20 Torque-controlled expansion anchor for use in cracked concrete: sizes M8, M10, M12, M16 and M20 Powers Fasteners Europe Stanley Black&Decker Deutschland GmbH European Anchor Development Center Black-&-Decker Str. 40 65510 Idstein Germany Plant 1 & 2 18 pages incluant 15 annexes qui font partie intégrante de cette évaluation 18 pages including 15 annexes which form an integral part of this assessment Base de l ETE Basis of ETA Cette evaluation remplace: This Assessment replaces ETAG 001, Version April 2013, utilisée en tant que EAD ETAG 001, Edition April 2013 used as EAD ATE 09/0317 valide du 03/06/2013 au 03/06/2018 ETA-09/0317 with validity from 03/06/2013 to 03/06/2018

Page 2 of 18 18/07/2014 1 Technical description of the product The Powers anchor is an anchor made of zinc electroplated steel which is placed into a drilled hole and anchored by torque-controlled expansion. The illustration and the description of the product are given in Annexes A. 2 Specification of the intended use The performances given in Section 3 are only valid if the anchor is used in compliance with the specifications and conditions given in Annexes B. The provisions made in this European technical assessment are based on an assumed working life of the anchor of 50 years. The indications given on the working life cannot be interpreted as a guarantee given by the producer, but are to be regarded only as a means for choosing the right products in relation to the expected economically reasonable working life of the works. 3 Performance of the product 3.1 Mechanical resistance and stability (ER Essential characteristic Performance Characteristic tension resistance acc. ETAG001, Annex C See Annex C 1 Characteristic shear resistance acc. ETAG001, Annex C See Annex C 2 Characteristic tension resistance acc. CEN/TS 1992-4 See Annex C 5 Characteristic shear resistance acc. CEN/TS 1992-4 See Annex C 6 Characteristic resistance under seismic action Cat. 1 acc. TR045 See Annex C 9 Characteristic resistance under seismic action Cat. 2 acc. TR045 See Annex C 10 Displacements See Annex C 11 3.2 Safety in case of fire (ER 2) Essential characteristic Reaction to fire Performance Anchorages satisfy requirements for Class A1 Characteristic tension resistance under fire acc. ETAG001, Annex C See Annex C 3 Characteristic shear resistance under fire acc. ETAG001, Annex C See Annex C 4 Characteristic tension resistance under fire acc. CEN/TS 1992-4 See Annex C 7 Characteristic shear resistance under fire acc. CEN/TS 1992-4 See Annex C 8 3.3 Hygiene, health and the environment (ER 3) Regarding dangerous substances contained in this European technical approval, there may be requirements applicable to the products falling within its scope (e.g. transposed European legislation and national laws, regulations and administrative provisions). In order to meet the provisions of the Construction Products Directive, these requirements need also to be complied with, when and where they apply. 3.4 Safety in use (ER 4) For Basic requirement Safety in use the same criteria are valid as for Basic Requirement Mechanical resistance and stability. 3.5 Protection against noise (ER 5) Not relevant.

Page 3 of 18 18/07/2014 3.6 Energy economy and heat retention (ER 6) Not relevant. 3.7 General aspects relating to fitness for use Durability and Serviceability are only ensured if the specifications of intended use according to Annex B1 are kept. 4 Assessment and verification of constancy of performance (AVCP) According to the Decision 96/582/EC of the European Commission 1, as amended, the system of assessment and verification of constancy of performance (see Annex V to Regulation (EU) No 305/201 given in the following table apply. Product Intended use Level or class System Metal anchors for use in concrete For fixing and/or supporting to concrete, structural elements (which contributes to the stability of the works) or heavy units 1 5 Technical details necessary for the implementation of the AVCP system Technical details necessary for the implementation of the Assessment and verification of constancy of performance (AVCP) system are laid down in the control plan deposited at Centre Scientifique et Technique du Bâtiment. The manufacturer shall, on the basis of a contract, involve a notified body approved in the field of anchors for issuing the certificate of conformity CE based on the control plan. Issued in Marne La Vallée on 18-07-2014 by Charles Baloche Directeur technique The original French version is signed 1 Official Journal of the European Communities L 254 of 08.10.1996

Page 4 of 18 18/07/2014 Hex head version: Hexagon nut Washer Bolt Expansion clip Marking: on the bolt, PTB1 (product name) followed by X / Y where X = nominal diameter, Y = total length of the anchor Anchor in use: Product description Installation condition Annex A1

Page 5 of 18 18/07/2014 Different parts of the anchor: Table 1: Materials Part Designation Material Protection 1 Bolt M8 to M20 Coldformed steel, grade C-1035 Zinc plated 5 m 2 Expansion clip M8 SS430 - M10 to M20 Carbon steel Zinc plated 3 Washer DIN 125 or EN ISO 7089 Zinc plated DIN 9021 or DIN EN ISO 7093 Zinc plated 4 Hexagonal nut DIN 934 or DIN EN ISO 4032, Grade 8 acc. to DIN EN ISO 20898-2 Zinc plated Product descripion Material Annex A2

Page 6 of 18 18/07/2014 Specifications of intended use Anchorages subject to: Static and quasi-static loads. Seismic loads (category C1 for M8 to M16, category C2 for M12). Fire. Base materials: Cracked concrete and non-cracked concrete. Reinforced or unreinforced normal weight concrete of strength classes C20/25 at least to C50/60 at most according to ENV 206: 2000-12. Use conditions (Environmental conditions): Structures subject to dry internal conditions. Design: The anchorages are designed in accordance with the ETAG001 Annex C Design Method for Anchorages or CEN/TS 1992-4-4 " Design of fastenings for use in concrete under the responsibility of an engineer experienced in anchorages and concrete work. For seismic application the anchorages are designed in accordance with TR045 Design of Metal Anchors For Use In Concrete Under Seismic Actions. For application with resistance under fire exposure the anchorages are designed in accordance with method given in TR020 Evaluation of Anchorage in Concrete concerning Resistance to Fire. Verifiable calculation notes and drawings are prepared taking account of the loads to be anchored. The position of the anchor is indicated on the design drawings. Installation: Anchor installation carried out by appropriately qualified personnel and under the supervision of the person responsible for technical matters of the site. Use of the anchor only as supplied by the manufacturer without exchanging the components of an anchor. Anchor installation in accordance with the manufacturer s specifications and drawings and using the appropriate tools. Effective anchorage depth, edge distances and spacing not less than the specified values without minus tolerances. Hole drilling by hammer drill. Cleaning of the hole of drilling dust. Application of specified torque moment using a calibrated torque wrench. In case of aborted hole, drilling of new hole at a minimum distance of twice the depth of the aborted hole, or smaller distance provided the aborted drill hole is filled with high strength mortar and no shear or oblique tension loads in the direction of aborted hole. Intended Use Specifications Annex B1

Page 7 of 18 18/07/2014 Table 2: Anchor dimensions Length cone bolt Minimum [mm] 60 80 85 115 155 L Maximum [mm] 240 220 220 220 220 Fixture thickness Minimum t fix [mm] 1 1 1 1 1 Maximum [mm] 185 140 125 110 65 Diameter cone neck d neck [mm] 5,5 7,3 8,7 11,7 14,6 Length expansion clip l clip [mm] 14 18 22 26 30 Width torque wrench SW [mm] 13 17 19 24 30 Table 3: Installation data Drill hole diameter d cut [mm] 8,45 10,45 12,5 16,5 20,5 Drill hole depth for h ef,min h 1,min [mm] 55 75 75 100 150 Drill hole depth for h ef,max h 1,max [mm] - - 95 120 - Minimum embedment depth h ef,min [mm] 40 60 60 80 110 Maximum embedment depth h ef,max [mm] - - 80 100 - Installation torque T inst [Nm] 25 45 70 120 200 Diameter through hole fixture d f [mm] 9 12 14 18 22 Min. member thickness h ef,min h min,1 [mm] 100 120 120 160 250 Min. member thickness h ef,max h min,2 [mm] - - 160 200 - Minimum edge distance c min [mm] 55 60 65 85 95 Corresponding spacing for s [mm] 120 150 190 160 240 Minimum spacing s min [mm] 50 55 60 70 95 Corresponding edge distance for c [mm] 90 90 100 130 240 Intended Use Installation parameters Annex B2

Page 8 of 18 18/07/2014 Table 4: Characteristic values for tension loads in case of static and quasi static loading for design design method A acc. ETAG001, Annex C Steel failure Characteristic resistance N Rk,s [kn] 22 31 43 79 95 Partial safety factor Ms Pullout failure [-] 1,5 Characteristic resistance in cracked concrete C20/25 Minimum embedment depth N Rk,p [kn] 4 9 12 25 20 Maximum embedment depth N Rk,p [kn] - - 12 25 - Partial safety factor for cracked concrete Mp [-] 1,8 2) Characteristic resistance in non-cracked concrete C20/25 Minimum embedment depth N Rk,p [kn] 7,5 16-4) 30 50 Maximum embedment depth N Rk,p [kn] - - 30-4) - Partial safety factor for non-cracked concrete Mp [-] 1,5 3) 1,8 2) Increasing factor N RK for concrete C30/37 [-] 1,22 concrete C40/50 c [-] 1,41 concrete C50/60 [-] 1,55 Concrete cone failure and splitting failure Minimum h Effective embedment depth ef,min [mm] 40 60 60 80 110 Maximum h ef,max [mm] - - 80 100 - cracked concrete Partial safety factor in Mc= Msp [-] 1,8 2) non-cracked concrete 1,5 3) 1,8 2) Increasing factor N RK for Characteristic spacing for failure by Characteristic edge distance for failure by concrete C30/37 [-] 1,22 concrete C40/50 c [-] 1,41 concrete C50/60 [-] 1,55 concrete cone splitting concrete cone splitting In absence of other national regulations 2) The value contains an installation safety factor 2 = 1,2 (h ef,min ) s cr,n,min [mm] 120 180 180 240 330 (h ef,max ) s cr,n,max [mm] - - 240 300 - (h ef,min ) s cr,sp,min [mm] 200 300 300 400 550 (h ef,max ) s cr,sp,max [mm] - - 400 500 - (h ef,min ) c cr,n,min [mm] 60 90 90 120 165 (h ef,max ) c cr,n,max [mm] - - 120 150 - (h ef,min ) c cr,sp,min [mm] 100 150 150 200 275 (h ef,max ) c cr,sp,max [mm] - - 200 250-3) The value contains an installation safety factor 2 = 1,0 4) Pullout failure not decisive. Use Equation acc. to ETAG 001, Annex C, for concrete cone failure. Design according to ETAG001, Annex C Characteristic resistance under tension loads Annex C1

Page 9 of 18 18/07/2014 Table 5: Characteristic values for shear loads in case of static and quasi static loading for design design method A acc. ETAG001, Annex C Steel failure without lever arm Characteristic resistance V Rk,s [kn] 10 15,5 21 37 54 Partial safety factor Ms Steel failure with lever arm [-] 1,25 Characteristic bending resistance M 0 Rk,s [Nm] 23 45 77 194 380 Partial safety factor Ms [-] 1,25 Concrete pry-out failure Factor in Eq. (5.6) of ETAG Annex C, 5.2.3.3 k [-] 1 2 2 2 2 Partial safety factor Mc [-] 1,5 Concrete edge failure Effective length under shear loading (h ef,min ) l f,min [mm] 40 60 60 80 110 (h ef,max ) l f,max [mm] - - 80 100 - Outside diameter of anchor d nom [mm] 8 10 12 16 20 Partial safety factor Mc [-] 1,5 In absence of other national regulations Design according to ETAG001, Annex C Characteristic resistance under shear loads Annex C2

Page 10 of 18 18/07/2014 Table 6: Characteristic tension resistance in cracked and non-cracked concrete under fire exposure for design method A acc. ETAG001, Annex C Steel failure Characteristic resistance R30 N Rk,s,fi [kn] 0,4 0,9 1,7 3,1 4,9 R60 N Rk,s,fi [kn] 0,3 0,8 1,3 2,4 3,7 R90 N Rk,s,fi [kn] 0,3 0,6 1,1 2,0 3,.2 R120 N Rk,s,fi [kn] 0,2 0,5 0,8 1,6 2,5 Pullout failure (cracked and non-cracked concrete) Minimum embedment depth Maximum embedment depth Characteristic resistance in concrete C20/25 R30 N Rk,p,fi [kn] 1 2,3 3 6,3 5,0 R60 N Rk,p,fi [kn] 1 2,3 3 6,3 5,0 R90 N Rk,p,fi [kn] 1 2,3 3 6,3 5,0 R120 N Rk,p,fi [kn] 0,8 1,8 2,4 5 4,0 R30 N Rk,p,fi [kn] - - 3 6,3 - R60 N Rk,p,fi [kn] - - 3 6,3 - R90 N Rk,p,fi [kn] - - 3 6,3 - R120 N Rk,p,fi [kn] - - 2,4 5 - Concrete cone and splitting failure 2) (cracked and uncracked concrete) Characteristic resistance in concrete C20/25 R30 N 0 Rk,c,fi [kn] 1,8 5 3 10,3 22,8 Minimum embedment depth R60 N 0 Rk,c,fi [kn] 1,8 5 3 10,3 22,8 R90 N 0 Rk,c,fi [kn] 1,8 5 3 10,3 22,8 R120 N 0 Rk,c,fi [kn] 1,5 4 2,4 8,2 18,3 R30 N 0 Rk,c,fi [kn] - - 10,3 18 - Maximum embedment depth R60 N 0 Rk,c,fi [kn] - - 10,3 18 - R90 N 0 [kn] - - 10,3 18 - Rk,c,fi R120 N 0 Rk,c,fi [kn] - - 8,2 14,4 - Characteristic spacing for (h ef,min ) s cr,n,min,fi [mm] 160 240 240 320 440 (h ef,max ) s cr,n,max,fi [mm] - - 320 400 - Characteristic edge distance for (h ef,min ) c cr,n,min,fi [mm] 80 120 120 160 220 (h ef,max ) c cr,n,max,fi [mm] - - 160 200-2) Design under fire exposure is performed according to the design method given in TR 020. Under fire exposure usually cracked concrete is assumed. The design equations are given in TR 020, Section 2.2.1. TR 020 covers design for fire exposure from one side. For fire attack from more than one side the edge distance must be increased to c min 300 mm and 2 h ef. As a rule, splitting failure can be neglected when cracked concrete and reinforcement is assumed. Design according to ETAG001, Annex C Characteristic tension resistance under fire exposure Annex C3

Page 11 of 18 18/07/2014 Table 7: Characteristic shear resistance in cracked and non-cracked concrete under fire exposure for design method A acc. ETAG001, Annex C Steel failure without lever arm Characteristic resistance Steel failure with lever arm Characteristic bending resistance R30 V Rk,s,fi [kn] 0,4 0,9 1,7 3,1 4,9 R60 V Rk,s,fi [kn] 0,3 0,8 1,3 2,4 3,7 R90 V Rk,s,fi [kn] 0,3 0,6 1,1 2,0 3,2 R120 V Rk,s,fi [kn] 0,2 0,5 0,8 1,6 2,5 R30 M 0 Rk,s,fi [Nm] 0,37 1,1 2,6 6,7 13,0 R60 M 0 Rk,s,fi [Nm] 0,34 1,0 2,0 5,0 9,7 R90 M 0 Rk,s,fi [Nm] 0,26 0,7 1,7 4,3 8,4 R120 M 0 Rk,s,fi [Nm] 0,19 0,6 1,3 3,3 6,5 Concrete pry-out failure Factor in equation (5.6) of ETAG Annex C, 5.2.3.3 k [-] 1 2 2 2 2 R30 V Rk,cp,fi [kn] 1,8 10 10 20,6 45,6 Characteristic resistance for h ef,min R60 V Rk,cp,fi [kn] 1,8 10 10 20,6 45,6 R90 V Rk,cp,fi [kn] 1,8 10 10 20,6 45,6 R120 V Rk,cp,fi [kn] 1,5 8 8 16,5 36,6 R30 V Rk,cp,fi [kn] - - 20,6 36 - Characteristic resistance for h ef,max R60 V Rk,cp,fi [kn] - - 20,6 36 - R90 V Rk,cp,fi [kn] - - 20,6 36 - R120 V Rk,cp,fi [kn] - - 16,5 28,8 - Concrete edge failure (h ef,min ) l f,min [mm] 40 60 60 80 110 Effective length under shear loading (h ef,max ) l f,max [mm] - - 80 100 - Outside diameter of anchor d nom [mm] 8 10 12 16 20 Design under fire exposure is performed according to the design method given in TR 020. Under fire exposure usually cracked concrete is assumed. The design equations are given in TR 020, Section 2.2.2. TR 020 covers design for fire exposure from one side. For fire attack from more than one side the edge distance must be increased to c min 300 mm and 2 h ef. Design according to ETAG001, Annex C Characteristic shear resistance under fire exposure Annex C4

Page 12 of 18 18/07/2014 Table 8: Characteristic values for tension loads in case of static and quasi static loading for design design method A acc. CEN/TS 1992-4 Steel failure Characteristic resistance N Rk,s [kn] 22 31 43 79 95 Partial safety factor Ms [-] 1,5 Pullout failure Characteristic resistance in cracked concrete C20/25 Minimum embedment depth N Rk,p [kn] 4 9 12 25 20 Maximum embedment depth N Rk,p [kn] - - 12 25 - Partial safety factor cracked concrete Mp [-] 1,8 2) Characteristic resistance in non-cracked concrete C20/25 Minimum embedment depth N Rk,p [kn] 7,5 16-4) 30 50 Maximum embedment depth N Rk,p [kn] - - 30-4) - Partial safety factor non-cracked concrete Mp [-] 1,5 3) 1,8 2) Increasing factor N RK for Concrete cone failure and splitting failure Effective embedment depth concrete C30/37 [-] 1,22 concrete C40/50 c [-] 1,41 concrete C50/60 [-] 1,55 Minimum h ef,min [mm] 40 60 60 80 110 Maximum h ef,max [mm] - - 80 100 - Factor in cracked concrete k cr [-] 7,2 Factor in non-cracked concrete k ucr [-] 10,1 Partial safety factor for cracked concrete Mc= Msp [-] 1,8 2) non-cracked concrete [-] 1,5 3) 1,8 2) Characteristic spacing for failure by Characteristic edge distance for failure by concrete cone splitting concrete cone splitting In absence of other national regulations 2) The value contains an installation safety factor 2= 1,2 (h ef,min ) s cr,n,min [mm] 120 180 180 240 330 (h ef,max ) s cr,n,max [mm] - - 240 300 - (h ef,min ) s cr,sp,min [mm] 200 300 300 400 550 (h ef,max ) s cr,sp,max [mm] - - 400 500 - (h ef,min ) c cr,n,min [mm] 60 90 90 120 165 (h ef,max ) c cr,n,max [mm] - - 120 150 - (h ef,min ) c cr,sp,min [mm] 100 150 150 200 275 (h ef,max ) c cr,sp,max [mm] - - 200 250-3) The value contains an installation safety factor 2= 1,0 4) Pullout failure not decisive. Use Equation acc. to ETAG 001, Annex C, for concrete cone failure. Design according to CEN/TS 1992-4 Characteristic resistance under tension loads Annex C5

Page 13 of 18 18/07/2014 Table 9: Characteristic values for shear loads in case of static and quasi static loading for design design method A acc. CEN/TS 1992-4 Steel failure without lever arm Characteristic resistance V Rk,s [kn] 10 15,5 21 37 54 Factor considering ductility k 2 [-] 0,8 Partial safety factor Ms Steel failure with lever arm [-] 1,25 Characteristic bending resistance M 0 Rk,s [Nm] 23 45 77 194 380 Partial safety factor Ms [-] 1,25 Concrete pry-out failure Factor in equation (16) of CEN/TS 1992-4-4, 6.2.2.3 k 3 [-] 1 2 2 2 2 Partial safety factor Mc [-] 1,5 Concrete edge failure Effective length under shear loading (h ef,min ) l f,min [mm] 40 60 60 80 110 (h ef,max ) l f,max [mm] - - 80 100 - Outside diameter of anchor d nom [mm] 8 10 12 16 20 Partial safety factor Mc [-] 1,5 In absence of other national regulations Design according to CEN/TS 1992-4 Characteristic resistance under shear loads Annex C6

Page 14 of 18 18/07/2014 Table 10: Characteristic tension resistance in cracked and non-cracked concrete under fire exposure for design method A acc. CEN/TS 1992-4 Steel failure Characteristic resistance R30 N Rk,s,fi [kn] 0,4 0,9 1,7 3,1 4,9 R60 N Rk,s,fi [kn] 0,3 0,8 1,3 2,4 3,7 R90 N Rk,s,fi [kn] 0,3 0,6 1,1 2,0 3,2 R120 N Rk,s,fi [kn] 0,2 0,5 0,8 1,6 2,5 Pullout failure (cracked and non-cracked concrete) Minimum embedment depth Maximum embedment depth Characteristic resistance in concrete C20/25 R30 N Rk,p,fi [kn] 1 2,3 3 6,3 5,0 R60 N Rk,p,fi [kn] 1 2,3 3 6,3 5,0 R90 N Rk,p,fi [kn] 1 2,3 3 6,3 5,0 R120 N Rk,p,fi [kn] 0,8 1,8 2,4 5 4,0 R30 N Rk,p,fi [kn] - - 3 6,3 - R60 N Rk,p,fi [kn] - - 3 6,3 - R90 N Rk,p,fi [kn] - - 3 6,3 - R120 N Rk,p,fi [kn] - - 2,4 5-2) Concrete cone and splitting failure 2) (cracked and uncracked concrete) Minimum embedment depth Maximum embedment depth Characteristic spacing Characteristic edge distance Characteristic resistance in concrete C20/25 R30 N 0 Rk,c,fi [kn] 1,8 5 3 10,3 22,8 R60 N 0 Rk,c,fi [kn] 1,8 5 3 10,3 22,8 R90 N 0 Rk,c,fi [kn] 1,8 5 3 10,3 22,8 R120 N 0 Rk,c,fi [kn] 1,5 4 2,4 8,2 18,3 R30 N 0 Rk,c,fi [kn] - - 10,3 18 - R60 N 0 Rk,c,fi [kn] - - 10,3 18 - R90 N 0 Rk,c,fi [kn] - - 10,3 18 - R120 N 0 Rk,c,fi [kn] - - 8,2 14,4 - (h ef,min ) s cr,n,min,fi [mm] 160 240 240 320 440 (h ef,max ) s cr,n,max,fi [mm] - - 320 400 - (h ef,min ) c cr,n,min,fi [mm] 80 120 120 160 220 (h ef,max ) c cr,n,max,fi [mm] - - 160 200 - Design under fire exposure is performed according to the design method given in TR 020. Under fire exposure usually cracked concrete is assumed. The design equations are given in TR 020, Section 2.2.2. TR 020 covers design for fire exposure from one side. For fire attack from more than one side the edge distance must be increased to c min 300 mm and 2 h ef. As a rule, splitting failure can be neglected when cracked concrete and reinforcement is assumed. Design according to CEN/TS 1992-4 Characteristic tension resistance under fire exposure Annex C7

Page 15 of 18 18/07/2014 Table 11: Characteristic shear resistance in cracked and non-cracked concrete under fire exposure for design method A acc. CEN/TS 1992-4 Steel failure without lever arm Characteristic resistance Steel failure with lever arm Characteristic bending resistance R30 V Rk,s,fi [kn] 0,4 0,9 1,7 3,1 4,9 R60 V Rk,s,fi [kn] 0,3 0,8 1,3 2,4 3,7 R90 V Rk,s,fi [kn] 0,3 0,6 1,1 2,0 3,2 R120 V Rk,s,fi [kn] 0,2 0,5 0,8 1,6 2,5 R30 M 0 Rk,s,fi [Nm] 0,37 1,1 2,6 6,7 13,0 R60 M 0 Rk,s,fi [Nm] 0,34 1,0 2,0 5,0 9,7 R90 M 0 Rk,s,fi [Nm] 0,26 0,7 1,7 4,3 8,4 R120 M 0 Rk,s,fi [Nm] 0,19 0,6 1,3 3,3 6,5 Concrete pry-out failure Factor in equation (16) of CEN TS 1992-4-4, 6.2.2.3 k 3 [-] 1 2 2 2 2 R30 V Rk,cp,fi [kn] 1,8 10 10 20,6 45,6 Characteristic resistance for h ef,min R60 V Rk,cp,fi [kn] 1,8 10 10 20,6 45,6 R90 V Rk,cp,fi [kn] 1,8 10 10 20,6 45,6 R120 V Rk,cp,fi [kn] 1,5 8 8 16,5 36,6 R30 V Rk,cp,fi [kn] - - 20,6 36 - Characteristic resistance for h ef,max R60 V Rk,cp,fi [kn] - - 20,6 36 - R90 V Rk,cp,fi [kn] - - 20,6 36 - R120 V Rk,cp,fi [kn] - - 16,5 28,8 - Concrete edge failure (h ef,min ) l f,min [mm] 40 60 60 80 110 Effective length under shear loading (h ef,max ) l f,max [mm] - - 80 100 - Outside diameter of anchor d nom [mm] 8 10 12 16 20 Design under fire exposure is performed according to the design method given in TR 020. Under fire exposure usually cracked concrete is assumed. The design equations are given in TR 020, Section 2.2.2. TR 020 covers design for fire exposure from one side. For fire attack from more than one side the edge distance must be increased to c min 300 mm and 2 h ef. Design according to CEN/TS 1992-4 Characteristic shear resistance under fire exposure Annex C8

Page 16 of 18 18/07/2014 Table 12: Characteristic values for resistance in case of seismic performance category C1 acc. TR045 Design of Metal anchor under Seismic Actions Anchor sizes Tension load Steel failure Characteristic resistance N Rk,s,seis [kn] 22 31 43 79 - Partial safety factor Ms,seis [-] 1,5 Pull-out failure N Rk,p,seis = c N 0 Rk,p,seis Characteristic resistance N 0 Rk,p,seis [kn] 3,5 8,6 11,5 24,3 - Partial safety factor Mp,seis [-] 1,8 Shear loads Steel failure without lever arm Characteristic resistance V Rk,s,seis [kn] 8,5 13,2 16,8 31,5 - Partial safety factor Ms,seis [-] 1,25 The recommended partial safety factors under seismic action ( M,seis) are the same as for static loading Design according to TR045 Characteristic resistance under seismic actions Annex C9

Page 17 of 18 18/07/2014 Table 13: Characteristic values for resistance in case of seismic performance category C2 acc. TR045 Design of Metal anchor under Seismic Actions Anchor sizes Tension load Steel failure Characteristic resistance 2) N Rk,s,seis [kn] - - 43 - - Partial safety factor 3) Ms,seis [-] 1,5 Pull-out failure N Rk,p,seis = c N 0 Rk,p,seis Characteristic resistance 2) N 0 Rk,p,seis [kn] - - 11,5 - - Partial safety factor 3) Mp, seis [-] 1,8 Displacement at DLS 2) N,sei (DLS) [mm] - - 7,0 - - Displacement at ULS 2) N,sei (ULS) [mm] - - 20,5 - - Shear loads Steel failure without lever arm Characteristic resistance 2) V Rk,s,seis [kn] - - 12,0 - - Partial safety factor 3) Ms, seis [-] 1,25 Displacement at DLS 2) V,sei (DLS) [mm] - - 5,6 - - Displacement at ULS 2) V,sei (ULS) [mm] - - 7,4 - - The listed displacements represent mean values. 2) A smaller displacement may be required in the design provisions stated in section Design of Anchorage, e.g. in the case of displacement sensitive fastenings or rigid supports. The characteristic resistance associated with such smaller displacement may be determined by linear interpolation or proportional reduction. 3) The recommended partial safety factors under seismic action ( M,seis) are the same as for static loading. Design according to TR045 Characteristic resistance under seismic actions Annex C10

Page 18 of 18 18/07/2014 Table 14: Displacements under tension loading Tension load in non-cracked concrete C20/25 to C50/60 Displacement Tension load in cracked concrete C20/25 to C50/60 [kn] Displacement [kn] h ef h ef h ef,min h ef,max h ef,min h ef,max h ef 6,6 11,8 17,3 22,2 22,2 36,9 30,7 N0 [mm] 0,1 0,1 0,2 0,2 0,3 0,6 0,4 N [mm] 1,2 1,2 1,5 1,5 1,3 1,3 1,2 2,2 7,4 9,8 9,8 15,9 22,1 12,3 N0 [mm] 0,4 0,6 0,7 0,7 0,8 1,2 0,5 N [mm] 1,2 1,2 1,5 1,5 1,3 1,3 1,2 Table 15: Displacements under shear loads Shear load in non-cracked concrete C20/25 [kn] 5,8 8,9 12,4 21,1 25,8 Displacement V0 [mm] 1,2 2,2 2,2 3,6 3,5 V [mm] 1,8 3,3 3,3 5,4 5,3 Displacement under shear loading: additional displacements due to through hole in the fixture shall be considered Design Displacements Annex C11