Netra X4200 M2 Server Site Planning Guide



Similar documents
Sun Management Center 3.6 Version 5 Add-On Software Release Notes

Sun TM SNMP Management Agent Release Notes, Version 1.6

Sun Management Center 3.6 Version 4 Add-On Software Release Notes

Sun SNMP Management Agent Release Notes, Version 1.5.5

Solaris 9 9/05 Installation Roadmap

Sun StorEdge Availability Suite Software Point-in-Time Copy Software Maximizing Backup Performance

Sun Enterprise Optional Power Sequencer Installation Guide

N1 Grid Service Provisioning System 5.0 User s Guide for the Linux Plug-In

Sun StorEdge A5000 Installation Guide

Sun StorEdge Enterprise Backup Software 7.2

Sun Management Center Change Manager Release Notes

Sun StorEdge RAID Manager Release Notes

Solaris 10 Documentation README

Sun Ultra TM. 5 and Ultra 10 Product Notes. Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA U.S.A.

RAID Controller PCI Card for the Sun Fire V60x and V65x Servers Release Notes

SCSI Sense Key Error Guide

Optimizing Solaris Resources Through Load Balancing

Sun Cluster 2.2 7/00 Data Services Update: Apache Web Server

Brocade 5300 Switch Hardware Release Notes

Upgrading the Solaris PC NetLink Software

Sun Enterprise 420R Server Product Notes

Sun Fire B10n Content Load Balancing Blade Product Notes

Brocade 300 Switch Hardware Release Notes

Solaris 9 Installation Roadmap

Service Level Definitions and Interactions

Netra Data Plane Software Suite 2.0 Update 2 Release Notes

Power Savings in the UltraSPARC T1 Processor

Sun Fire 6800/4810/4800/3800 Systems Firmware Release Notes

Sun StorEdge Network FC Switch-8 and Switch-16 Release Notes

Brocade SilkWorm 4100 FC Switch Release Notes

Sun StorEdge T3 Dual Storage Array - Part 1

Scrubbing Disks Using the Solaris Operating Environment Format Program

Sun StorEdge N8400 Filer Release Notes

SunFDDI 6.0 on the Sun Enterprise Server

Comparing JavaServer Pages Technology and Microsoft Active Server Pages

Service Level Agreement in the Data Center

Sun Grid Engine Release Notes

Sun StorEdge SAN Foundation Release Notes

Solaris Bandwidth Manager

Sun Fire V480 Server Product Notes

Java Dynamic Management Architecture for Intelligent Networks

LAN-Free Backups Using the Sun StorEdge Instant Image 3.0 Software

Sun Ray, Smart Cards, and Citrix

Sun Fire V20z Server Release Notes

Sun Netra T5220 Server

Sun N1 Service Provisioning System User s Guide for Linux Plug-In 2.0

Sun Management Center 3.5 Update 1b Release Notes

Reducing the Backup Window With Sun StorEdge Instant Image Software

Start Here. Installation and Documentation Reference. Sun StorEdgeTM 6120 Array

JumpStart : NIS and sysidcfg

Exploring the iplanet Directory Server NIS Extensions

Sun Blade 100 and Sun Blade 150 Workstations

Sun Blade 1500 Workstation Product Notes

Managing NFS Workloads

Disaster Recovery Requirements Analysis

Sun Fire V480 Server Setup and Rackmounting Guide

Sun GlassFish Enterprise Manager SNMP Monitoring 1.0 Installation and Quick Start Guide

A Strategy for Managing Performance

Important Note on New Product Names

Sun Cobalt Control Station. Using the LCD Console

Developing a Security Policy

HelloWorld SOAP Sample:

Sun Ray Server Software 3 Release Notes

Getting StartedWith Sun Java System Application Server 9.1 Update 2

Automating Centralized File Integrity Checks in the Solaris 10 Operating System

Sun Fire 6800/4810/4800/3800 Systems Software Release Notes

Sun Fire 6800/4810/4800/ 3800 Systems Product Notes

Veritas Storage Foundation 5.0 Software for SPARC

N1 Grid Engine 6 Release Notes

The UltraSPARC T1 Processor - High Bandwidth For Throughput Computing

Service Level Management in the Data Center

Sun Java System Connector for Microsoft Outlook 7.2 Installation Guide

Rapid Recovery Techniques: Exploring the Solaris Software Registry

Using Linux mdadm Multipathing with Sun StorEdge Systems

Sun GlassFish Enterprise Manager Performance Monitor 1.0 Getting Started Guide

Consolidation in the Data Center

ProjectWebSynergy Milestone 4 Release Notes

Distributed Application Management using Jini Connection Technology

How To Start A Glassfish V3 Application Server Quick Start (Windows) On A Microsoft Server (Windows 7)

Sun Ray Connector for Windows OS, Version 2.1 Release Notes

Sun StorEdge Instant Image 3.0 and Oracle8i Database Best Practices

Sun StorEdge network FC switch-8 and switch-16 Release Notes

Java Management Extensions SNMP Manager API

How To Use Alom On A Pc Or Macbook With A Microsoft Powerbook 2.5 (Powerbook 2) On A Microtune 2.2 (Powerstation 2) (Powerclock) (For Macbook 2 With A

Solaris Resource Manager

Sun StorEdge RAID Manager 6.22 User s Guide

Installation and Configuration

Sun SPARC Enterprise M4000/M5000 Servers Site Planning Guide

Sun 450 MHz UltraSPARC -II Module Upgrade

Data Center Design Philosophy

Trust Modeling for Security Architecture Development

Rapid Recovery Techniques: Auditing Custom Software Configuration

Sun Microsystems, Inc Garcia Avenue Mountain View, CA FAX

Sun Fire V210 and V240 Servers Parts Replacement Manual

The Solaris Fingerprint Database - A Security Tool for Solaris Operating Environment Files

MIGRATION WHITEPAPER MIGRATING FROM MICROSOFT OFFICE TO OPENOFFICE.ORG OR STAROFFICE 9

Transcription:

Netra X4200 M2 Server Site Planning Guide Sun Microsystems, Inc. www.sun.com Part No. 820-0069-12 May 2008, Revision A Submit comments about this document at: http://www.sun.com/hwdocs/feedback

Copyright 2007 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. All rights reserved. Sun Microsystems, Inc. has intellectual property rights relating to technology that is described in this document. In particular, and without limitation, these intellectual property rights may include one or more of the U.S. patents listed at http://www.sun.com/patents and one or more additional patents or pending patent applications in the U.S. and in other countries. This document and the product to which it pertains are distributed under licenses restricting their use, copying, distribution, and decompilation. No part of the product or of this document may be reproduced in any form by any means without prior written authorization of Sun and its licensors, if any. Third-party software, including font technology, is copyrighted and licensed from Sun suppliers. Parts of the product may be derived from Berkeley BSD systems, licensed from the University of California. UNIX is a registered trademark in the U.S. and in other countries, exclusively licensed through X/Open Company, Ltd. Sun, Sun Microsystems, the Sun logo, Java, AnswerBook2, docs.sun.com, Netra, and Solaris are trademarks or registered trademarks of Sun Microsystems, Inc. in the U.S. and in other countries. All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International, Inc. in the U.S. and in other countries. Products bearing SPARC trademarks are based upon an architecture developed by Sun Microsystems, Inc. The OPEN LOOK and Sun Graphical User Interface was developed by Sun Microsystems, Inc. for its users and licensees. Sun acknowledges the pioneering efforts of Xerox in researching and developing the concept of visual or graphical user interfaces for the computer industry. Sun holds a non-exclusive license from Xerox to the Xerox Graphical User Interface, which license also covers Sun s licensees who implement OPEN LOOK GUIs and otherwise comply with Sun s written license agreements. U.S. Government Rights Commercial use. Government users are subject to the Sun Microsystems, Inc. standard license agreement and applicable provisions of the FAR and its supplements. DOCUMENTATION IS PROVIDED "AS IS" AND ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT, ARE DISCLAIMED, EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID. Copyright 2007 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, Californie 95054, États-Unis. Tous droits réservés. Sun Microsystems, Inc. possède les droits de propriété intellectuels relatifs à la technologie décrite dans ce document. En particulier, et sans limitation, ces droits de propriété intellectuels peuvent inclure un ou plusieurs des brevets américains listés sur le site http://www.sun.com/patents, un ou les plusieurs brevets supplémentaires ainsi que les demandes de brevet en attente aux les États-Unis et dans d autres pays. Ce document et le produit auquel il se rapporte sont protégés par un copyright et distribués sous licences, celles-ci en restreignent l utilisation, la copie, la distribution, et la décompilation. Aucune partie de ce produit ou document ne peut être reproduite sous aucune forme, par quelque moyen que ce soit, sans l autorisation préalable et écrite de Sun et de ses bailleurs de licence, s il y en a. Tout logiciel tiers, sa technologie relative aux polices de caractères, comprise, est protégé par un copyright et licencié par des fournisseurs de Sun. Des parties de ce produit peuvent dériver des systèmes Berkeley BSD licenciés par l Université de Californie. UNIX est une marque déposée aux États-Unis et dans d autres pays, licenciée exclusivement par X/Open Company, Ltd. Sun, Sun Microsystems, le logo Sun, Java, AnswerBook2, docs.sun.com, Netra, et Solaris sont des marques de fabrique ou des marques déposées de Sun Microsystems, Inc. aux États-Unis et dans d autres pays. Toutes les marques SPARC sont utilisées sous licence et sont des marques de fabrique ou des marques déposées de SPARC International, Inc. aux États-Unis et dans d autres pays. Les produits portant les marques SPARC sont basés sur une architecture développée par Sun Microsystems, Inc. L interface utilisateur graphique OPEN LOOK et Sun a été développée par Sun Microsystems, Inc. pour ses utilisateurs et licenciés. Sun reconnaît les efforts de pionniers de Xerox dans la recherche et le développement du concept des interfaces utilisateur visuelles ou graphiques pour l industrie informatique. Sun détient une license non exclusive de Xerox sur l interface utilisateur graphique Xerox, cette licence couvrant également les licenciés de Sun implémentant les interfaces utilisateur graphiques OPEN LOOK et se conforment en outre aux licences écrites de Sun. LA DOCUMENTATION EST FOURNIE "EN L ÉTAT" ET TOUTES AUTRES CONDITIONS, DÉCLARATIONS ET GARANTIES EXPRESSES OU TACITES SONT FORMELLEMENT EXCLUES DANS LA LIMITE DE LA LOI APPLICABLE, Y COMPRIS NOTAMMENT TOUTE GARANTIE IMPLICITE RELATIVE À LA QUALITÉ MARCHANDE, À L APTITUDE À UNE UTILISATION PARTICULIÈRE OU À L ABSENCE DE CONTREFAÇON. Please Recycle

Contents Preface v Netra X4200 M2 Server Site Planning Guide 1 Physical Specifications 1 Clearance for Service Access 2 Environmental Specifications 2 Power Source Requirements 3 Agency Compliance Specifications 4 Recommended Operating Environment 5 Electrical Power 5 Surge Protector Devices 5 Ambient Temperature 6 Ambient Relative Humidity 6 Airflow Considerations 6 Acoustic Noise Emissions 7 Calculating Heat Dissipation 7 NEBS Level 3 Certification 7 iii

iv Netra X4200 M2 Server Site Planning Guide May 2008

Preface The Netra X4200 M2 Server Site Planning Guide provides the data center site requirements for the installation of the Netra X4200 M2 server. This document provides detailed physical, electrical, power, and cooling specifications for the server. This document is written for data center administrators who have advanced experience maintaining a data center environment and for experienced system installers. v

Related Documentation Application Title Part Number Format Location Service Netra X4200 M2 Server Service Manual 820-0063 PDF Online Installation Netra X4200 M2 Server Setup Guide 820-0062 PDF Online Netra X4200 M2 Operating System Installation Guide Netra X4200 M2 Server Windows Operating System Installation Guide 820-0065 PDF Online 819-4346 PDF Online Updates Netra X4200 M2 Server Product Notes 820-0067 PDF Online Planning Netra X4200 M2 Server Site Planning Guide 820-0069 PDF Online Compliance Netra X4200 M2 Server Safety and Compliance Guide The documents listed as online are available at: http://docs.sun.com/app/docs/prod/nt4200m2.srvr#hic 820-0068 PDF Online RAID Sun LSI 106x RAID User s Guide 820-4933 PDF Online ILOM Hardware Safety Integrated Lights Out Manager (ILOM) Administration Guide Important Safety Information for Sun Hardware Systems 819-1160 PDF Online 816-7190 Print In ship kit vi Netra X4200 M2 Server Site Planning Guide May 2008

Documentation, Support, and Training Sun Function Documentation Support Training URL http://www.docs.sun.com/ http://www.sun.com/support/ http://www.sun.com/training/ Third-Party Web Sites Sun is not responsible for the availability of third-party web sites mentioned in this document. Sun does not endorse and is not responsible or liable for any content, advertising, products, or other materials that are available on or through such sites or resources. Sun will not be responsible or liable for any actual or alleged damage or loss caused by or in connection with the use of or reliance on any such content, goods, or services that are available on or through such sites or resources. Sun Welcomes Your Comments Sun is interested in improving its documentation and welcomes your comments and suggestions. You can submit your comments by going to: http://www.sun.com/hwdocs/feedback Please include the title and part number of your document with your feedback: Netra X4200 M2 Server Site Planning Guide, part number 820-0069-12 Preface vii

viii Netra X4200 M2 Server Site Planning Guide May 2008

CHAPTER Netra X4200 M2 Server Site Planning Guide This guide provides the specifications and site requirements you need when planning the installation of the Netra X4200 M2 server. For safety and compliance information, refer to the Netra X4200 M2 Server Safety and Compliance Guide, 820-0068, and the Important Safety Information for Sun Hardware Systems, 816-7190. Physical Specifications These are the physical specifications for the server. Dimension Server Dimensions Measurements Width Depth Bezel Server chassis To connector plane Maximum overall 17.4 in. (442.0 mm) 16.75 in. (425.5 mm) 19 in. (481.9 mm) 20.25 in. (514.4 mm) Height 2U nominal 3.4 in. (87.1 mm) Weight Server only 35.0 lbs (15.9 kg) 1

Clearance for Service Access These are the minimum clearances needed for servicing the server. Description Clearance, front of server Clearance, rear of server Specification 36 inches (91 cm) 36 inches (91 cm) Environmental Specifications These are the environmental specifications for the AC and DC versions of the server. Specification Operating Non-operating Ambient temperature * Relative humidity Elevation (Sun requirement) 41 F to 104 F (5 C to 40 C) up to 6000 feet (1829 meters) \ 5% to 85% noncondensing, short term 25 F to 113 F 5% to 90% noncondensing, but not to exceed 0.024 kg of water per kg of dry air (0.053 lbs. water/2.205 lbs. dry air) Maximum 9840 feet (3000 meters) at 104 F (40 C) Elevation (NEBS requirement) 200 feet to 5900 feet ( 60 meters to 1800 meters) at 104 F (40 C) 5900 feet to 13,100 feet (1800 meters to 4000 meters) at 86 F (30 C) 40 F to 158 F ( 40 C to 70 C) Up to 93% noncondensing 100.4 F (38 C) maximum wet bulb Maximum 39,370 feet (12,000 meters) * Does not apply to removable media devices. \ Maximum ambient operating temperature is derated by 1 degree C per 500m elevation. 2 Netra X4200 M2 Server Site Planning Guide May 2008

Power Source Requirements The server has two hot-swappable power supplies. Both the AC and the DC power supplies are capable of current sharing. To ensure redundant operation of the power supplies, connect the two power cords to separate circuits. The following table shows the electrical limits and ranges for the server. Parameter DC Version Requirement AC Version Requirement Voltage 48 VDC or 60 VDC nominal 100 VAC to 240 VAC single phase, 47 63 Hz Current (per input) Current (total) Power * 10.2A maximum per input at 48 VDC 10.4A maximum total for all inputs at 48VDC 500 Watts 550 Watts DC Input Treatment Isolated DC Return (DC-I) N/A * Total input power is approximately equally divided among the operating power supplies. 5.4A maximum per input at 100 VAC 5.6 A maximum total for all inputs at 100 VAC Caution WARNING: The intra-building port(s) of the equipment or subassembly is suitable for connection to intrabuilding or unexposed wiring or cabling only. The intra-building port(s) of the equipment or subassembly MUST NOT be metallically connected to interfaces that connect to the OSP or its wiring. These interfaces are designed for use as intra-building interfaces only (Type 2 or Type 4 ports as described in GR-1089-CORE, Issue 4) and require isolation from the exposed OSP cabling. The addition of Primary Protectors is not sufficient protection in order to connect these interfaces metallically to OSP wiring. Chapter Netra X4200 M2 Server Site Planning Guide 3

Agency Compliance Specifications The server complies with the following specifications. Category Safety Ergonomics RFI/EMI Immunity Telecommunications Regulatory Markings (pending) Relevant Standards UL/CSA-60950-1 EN60950-1 IEC60950-1 CB Scheme with all country deviations IEC825-1, 2 CFR21 part 1040 CNS14336, GB4943 EK1-ITB-2000 EN55022 Class A 47 CFR 15B Class A ICES-003 Class A VCCI Class A AS/NZ 3548 Class A CNS 13438 Class A KSC 5858 Class A GB9254 Class A EN61000-3-2 GB17625.1 EN61000-3-3 EN55024 IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 IEC 61000-4-5 IEC 61000-4-6 IEC 61000-4-8 IEC 61000-4-11 EN300-386 IEC 60068 CE, FCC, ICES-003, C-tick, VCCI, GOST-R, BSMI, MIC, UL/cUL, UL/DEMKO/GS, UL/S-mark, CCC 4 Netra X4200 M2 Server Site Planning Guide May 2008

Recommended Operating Environment Your environmental control system must provide intake air for the server that complies with the limits specified in Environmental Specifications on page 2. To avoid overheating, do not direct warmed air: Toward the front air intake of the server Toward the server access panels Note When you receive your server, place it in the environment in which you will install it. Leave the server in its shipping crate at its final destination for 24 hours. This resting period prevents thermal shock and condensation. The server has been tested to meet all functional requirements when operating in the operating environmental limits presented in Environmental Specifications on page 2. Operating computer equipment in extremes of temperature or humidity increases the failure rate of hardware components. To minimize the chance of component failure, use the server within the optimal temperature and humidity ranges. Electrical Power Good practice is to connect each power supply to a separate circuit, which enables the server to remain operational if one of the circuits fails. Consult your local electrical codes for any additional requirements. Surge Protector Devices An external Surge Protection Device (SPD) is not intended to be used at the AC input of this network equipment. The Netra X4200 server meets NEBS criteria without the addition of an SPD. Chapter Netra X4200 M2 Server Site Planning Guide 5

Ambient Temperature An ambient temperature range of 21 C (69.8 F) to 23 C (73.4 F) is optimal for server reliability. At 22 C (71.6 F) it is easy to maintain safe relative humidity levels. Operating in this temperature range provides a buffer if the environmental support systems fail. Ambient Relative Humidity Ambient relative humidity levels between 45% and 50% are the most suitable for data processing operations in order to: Prevent corrosion Provide an operating time buffer in the event of environmental control system failure Help avoid failures caused by the intermittent interference from static discharges that occur when relative humidity is too low Electrostatic discharge (ESD) is easily generated and less easily dissipated in areas where the relative humidity is below 35%, and becomes critical when levels drop below 30%. Airflow Considerations Ensure that there is unobstructed airflow through the chassis. The server uses internal blowers that can achieve a total airflow of 120 CFM (3.4 m 3 /min) in normal operating conditions. Ensure that inlet air enters at the front of the server and exits from the back. Ensure that ventilation openings such as cabinet doors, for both the inlet and exhaust of the server, provide a minimum open area of 35.5 in. 2 (231 cm 2 ) each. This equates to a 60% open area perforation pattern across the front and rear area of the server. The impact of other open area characteristics that are more restrictive should be evaluated by the user. Ensure that front and rear clearances between the cabinet doors and the server allow a minimum of 0.2 in. (5 mm) at the front of the server and 3.15 in. (80 mm) at the rear of the server when the server is mounted. These clearance values are based on the above inlet and exhaust impedance (available open area) and assume a uniform distribution of the open area across the inlet and exhaust areas. Clearance values greater than these are recommended for improved cooling performance. 6 Netra X4200 M2 Server Site Planning Guide May 2008

Note The combination of inlet and exhaust restrictions such as cabinet doors and the spacing of the server from the doors can affect the cooling performance of the server and should be evaluated by the user. The server placement is particularly important for high-temperature NEBS environments where the server inlet ambient temperature is 55 C (131 F). (The DC-powered server is NEBS compliant.) Take care to prevent recirculation of exhaust air within a rack or cabinet. Manage cables to minimize interference with the server exhaust vent. Ensure that air temperature rise through the server is no greater than 68 F (20 C). Acoustic Noise Emissions The acoustic noise emissions on the server are listed below: Parameter Operating Idling Acoustic power LWAd (1B=10dB) 7.1 B 7.2 B Acoustic pressure LpAm 58.9 dba 59.0 dba Declared noise emissions are in accordance with ISO 9296 standards. Calculating Heat Dissipation To calculate the heat generated by a server so that you can estimate the heat your cooling system must dissipate, convert the figure for the server s power requirement from Watts to BTU/hr. A general formula for doing this is to multiply the power requirement figure in Watts by 3.412. NEBS Level 3 Certification Telcordia certified that the DC-powered version of the server meets NEBS Level 3 requirements per SR-3580, including the appropriate sections of GR-63-CORE (Network Equipment-Building System Requirements: Physical Protection) and GR-1089-CORE (Electromagnetic Compatibility and Electrical Safety Generic Criteria for Network Telecommunications Equipment). Chapter Netra X4200 M2 Server Site Planning Guide 7

Caution To maintain NEBS compliance, the network management (NET MGT) Ethernet port and the RJ-45 serial management (SERIAL MGT) port must use shielded cables, and both ends of the shield must be grounded. 8 Netra X4200 M2 Server Site Planning Guide May 2008