Transmitter TEMPERATURE HEAD TRANSMITTER. Series 440 Programmable RTD Temperature Transmitter. Features and Benefits. Application Areas TT-1

Similar documents
Technical Information RIA14

J TB/TW Temperature limiter, temperature monitor

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

CPA PC-Programmable Current/Voltage and RTD/Thermocouple Limit Alarm Trips

Rosemount 333 HART Tri-Loop

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

FieldIT Head mounted Temperature Transmitter TF02/TF02-Ex

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Rosemount 333 HART Tri-Loop

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Pressure transmitter For general industrial applications Model A-10

Digital display DA 48

Analog signal converters CC-E I/I Current / current isolators

Telephone- and leased line modem for industrial applications TD-36

Wahl C50 Calibrator FEATURES

3DLevelScanner II TECHNICAL DATA SHEET

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Technical Data Sheet. 3DLevelScanner

Duct Humidity Transmitter

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

JUMPFLEX 857 Series ma V ma. Transducers / Relay and Optocoupler Modules

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Hand-held thermometer Model CTH7000

Digital input modules

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Differential Charge Amplifier

Multi-Range Programmable DC Power Supplies 9115 Series

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Model UT713 OPERATING MANUAL

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Digital Pressure Measuring Instrument MDR480

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

Liquid Level Limit Switch liquiphant T FTL 20

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Multi-Range Programmable DC Power Supplies 9115 Series

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Power Supplies 3. SDN-P DIN Rail Series

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

T0118 T2118 T3118. Instruction Manual

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

MLC TM Maximum Productivity and Versatility for Control without Compromise!

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Safety technique. Emergency stop module BO 5988 safemaster

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Digital inductive conductivity transmitter

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

4-Channel Thermometer / Datalogger

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Features. Picture. Specifications

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

RTD Temperature Probe for the Food/Pharmaceutical Industry

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Rack mounted telephone- and leased line modem for industrial applications

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

MINI MCR-SL-R-UI(-SP)

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

TEIP11 I/P signal converter for standard signals. Measurement made easy

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

APPLICATION NOTES OF SIGNAL ISOLATORS

Measuring Temperature withthermistors a Tutorial David Potter

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

PROCESS AUTOMATION MANUAL. Universal Temperature Converter. KFD2-UT2-(Ex)*(-1) ISO9001

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Rosemount 644 Temperature Transmitter

USB-500/600 Series Low-Cost Data Loggers and Accessories

Electronic Pressure Switch EDS 3000

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

TX OPEN RS232/485 module

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

Series 7500 Torque Sensor

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Electronic Pressure Switch EDS 300

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Electronic Control Devices The European Product Catalogue 2007

TC-9102 Series Surface Mount Temperature Controllers

Temperature Transmitters ZTT series

Transcription:

Series 440 Programmable RTD Temperature Transmitter TEMPERATURE HEAD TRANSMITTER Application Areas Features and Benefits Distributed By: M&M Control Service, Inc. www.mmcontrol.com/pyromation.php 800-876-0036 847-356-0566 TT-1

Configuration Code TM01 Series 440 Programmable RTD Temperature Transmitter ORDER S Unconfigured Order Number: Example Configured Order Number: 440-00 [1] 4 4 0 1 2 3-3 85 U - 4 5 F S (50-300) 1 2 RTD (2-wire) 3 RTD (3-wire) 2 3 U D 85-1 ) 3-wire Pt100 (0-100) 4 RANGE 5 C F Celsius Fahrenheit Accessories 10303 Software (USB) 10307 TT-2 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/pyromation.php 800-876-0036 847-356-0566 322-6

Series 440 Programmable RTD Temperature Transmitter Specifications Resistance Thermometer Input (RTD) TYPE MEASUREMENT RANGE MINIMUM RANGE o C -1 ) Connection Type Sensor cable resistance Sensor current Output (Analog) Output signal Transmission as Maximum load Induced current required Current limit Switch on delay Electronic response time (4 to 20) ma or (20 to 4) ma Temperature linear (V power supply 4 s (during power 1 a 1 s Failure Mode Undershooting measurement range Exceeding measurement range Sensor breakage/short circuit Electronic Connection Power supply Allowable ripple U b U ss b max Resistance Thermometer Accuracy (RTD) TYPE MEASUREMENT ACCURACY Pt100 [1] Reference conditions [73 ± 9] General Accuracy Influence of power supply [2] Load influence [2] Temperature drift T d Long term stability [3] [1][3] [1] % is related to the adjusted measurement range (the value to be applied is the greater) [2] All data is related to a measurement end value of 20 ma [3] Under reference conditions 323-7 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/pyromation.php 800-876-0036 847-356-0566 TT-3

Series 440 Programmable RTD Temperature Transmitter Specifications Ambient Conditions Ambient temperature (-40 to 85) o C [-40 to 185] o F Storage temperature (-40 to 100) o C [-40 to 212] o F Climatic class EN 60 654-1, Class C Condensation Permitted Shock resistance 4 g / (2 to 150) Hz according to IEC 60 068-2-6 EMC immunity Interference immunity and interference emission according to EN 61 326-1 (1EC 1326) Mechanical Construction 0.24 [6] DIMENSIONS IN INCHES [mm] Dimensions 1.49 [38] 0.89 [23] 1.75 [44] 2.17 [55] Weight Materials Terminals Approximately 44 g 15 AWG (maximum) Terminal Connections Power supply and current output (10 to 30) V dc (4 to 20) ma 2-Wire 3-Wire SETUP SOCKET Approvals marked Unit complies with the legal requirements set forth by the EU regulations. UL Recognized Component General Purpose and non-incendive for use in hazardous locations Class I, Division 2 Groups A, B, C and D TT-4 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/pyromation.php 800-876-0036 847-356-0566 324-6

Configuration Code TM01 Series 441 Programmable Temperature Transmitter The Series 441 programmable temperature transmitter is a 2-wire transmitter with an analog output. It has measurement input for resistance thermometers (RTD) in 2-, 3- or 4-wire connections, thermocouples, resistance and voltage inputs. Setting up of the transmitter is done using the communication cable. These small units can be mounted in Pyromation DIN (Form B) connection heads or they can be used for surface mounting by using a 35 mm DIN-rail mounting clip. TEMPERATURE HEAD TRANSMITTER Universal head transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage inputs, programmable using a PC, for installation in a sensor head (Form B) Application Areas converting various input signals into an scalable Resistance thermometer (RTD) Thermocouple (TC) Voltage (mv) connector Features and Benefits Intrinsically safe and non-incendive for for 307-8 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/pyromation.php 800-876-0036 847-356-0566 TT-5

Configuration Code TM01 Series 441 Programmable Temperature Transmitter ORDER S Unconfigured Order Number: Example Configured Order Number: 441-00 [1] 4 4 1 1 2 3-1 J U - 4 F S (50-300) 1 1 Thermocouple (TC) 2 RTD (2-wire) 3 RTD (3-wire) 4 RTD (4-wire) 3 U D 2 J Type J thermocouple K Type K thermocouple T Type T thermocouple N Type N thermocouple E Type E thermocouple R Type R thermocouple S Type S thermocouple B Type B thermocouple -1 ) -1 ) -1 ) MV Millivolts W Resistance [1] Default setting for unconfigured transmitter is 4 RANGE S ( lower limit upper limit) 5 C F Accessories 10303 Celsius Fahrenheit Communication cable and software (USB) 10307 TT-6 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/pyromation.php 800-876-0036 847-356-0566 308-7

Series 441 Programmable Temperature Transmitter Specifications INPUT Resistance Thermometer (RTD) TYPE MEASUREMENT RANGE MINIMUM RANGE o C -1 ) Pt500 Pt1000 o C -1 ) Ni500 Ni1000 Connection type t Resistance ( ) TYPE MEASUREMENT RANGE MINIMUM RANGE Thermocouples (TC) TYPE MEASUREMENT RANGE MINIMUM RANGE K (NiCr-Ni) N (NiCrSi-NiSi) 500 500 500 50 50 50 50 50 500 500 50 50 500 Voltage (mv) TYPE MEASUREMENT RANGE MINIMUM RANGE 309-5 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/pyromation.php 800-876-0036 847-356-0566 TT-7

Series 441 Programmable Temperature Transmitter Specifications OUTPUT Output (Analog) Output signal Transmission as Maximum load Digital filter 1st degree Induced current required Current limit Switch on delay Electronic response time (4 to 20) ma or (20 to 4) ma Temperature linear, resistance linear, voltage linear (V power supply - 8 V) / 0.025 A (current output) (0 to 8) s 4 s (during power up I a = 3.8 ma) 1 s Failure Mode Undershooting measurement range Exceeding measurement range Sensor breakage/short circuit [1] Decrease to 3.8 ma Increase to 20.5 ma Electrical Connection Power supply Galvanic isolation (In/out) Allowable ripple U b = (8 to 30) V dc, polarity protected Û = 3.75 kv ac U ss b max = 1 khz ACCURACY Reference conditions Calibration temperature (23 ± 5) o C [73 ± 9] o F Resistance Thermometer (RTD) TYPE MEASUREMENT ACCURACY Pt100, Ni100 Pt500, Ni500 Pt1000, Ni1000 ± 0.2 C or 0.08% [2] ± 0.5 C or 0.20% [2] ± 0.3 C or 0.12% [2] Resistance ( ) TYPE MEASUREMENT ACCURACY MEASUREMENT RANGE Resistance [2] [2] [1] Not for thermocouple [2] % is related to the adjusted measurement range (the value to be applied is the greater) TT-8 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/pyromation.php 800-876-0036 847-356-0566 310-7

Series 441 Programmable Temperature Transmitter Specifications ACCURACY (continued) Thermocouple (TC) TYPE K, J, T, E, L, U N, C, D S, B, R MoRe5-MoRe41 MEASUREMENT ACCURACY ± 0.5 C or 0.08% [1] ± 1.0 C or 0.08% [1] ± 2.0 C or 0.08% [1] Influence of the internal reference junction Pt100 ± (0.30 + 0.005 t ) C t = value of temperature without regard to sign C Voltage (mv) TYPE MEASUREMENT ACCURACY MEASUREMENT RANGE Millivolt (mv) ± 20 μv or 0.08% [1] (-10 to 100) mv General Accuracy Influence of power supply ± 0.01%/V deviation from 24 V [2] Load influence [2] Resistive thermometer (RTD): T d Temperature drift Resistive thermometer Pt100: T d Thermocouple (TC): T d = Deviation of the ambient temperature according to the reference condition Long term stability [3] [1][3] [1] % is related to the adjusted measurement range (the value to be applied is the greater) [2] All data is related to a measurement end value of 20 ma [3] Under reference conditions INSTALLATION CONDITIONS Ambient Conditons Ambient temperature (-40 to 85) C [-40 to 185] F Storage temperature (-40 to 100) C [-40 to 212] F Climatic class To EN 60 654-1, Class C Moisture condensation Allowable Vibration protection 4 g / (2 to 150) Hz according to IEC 60 068-2-6 EMC immunity Interference immunity and interference emission as per EN 61 326-1 (IEC 1326) 311-8 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/pyromation.php 800-876-0036 847-356-0566 TT-9

Series 441 Programmable Temperature Transmitter Specifications MECHANICAL CONSTRUCTION 0.197 [5] DIMENSIONS IN INCHES [mm] Dimensions 0.28 [7] 1.3 [33] 1.73 [44] 0.89 [23] Weight Materials Terminals approximately 40 g 15 AWG (maximum) Terminal Connections Power supply and current output SETUP socket 2 (-) 1 (+) (8 to 30) V dc (4 to 20) ma Sensor Connection 6 2-Wire 3-Wire 4-Wire 5 4 3 Remote Operation Configurable parameters Sensor type and connection type, engineering units ( C/ F), measurement range, internal/external cold junction compensation, cable resistance compensation on 2 wire connection, fault conditioning, output signal (4 to 20) ma or (20 to 4) ma, digital filter (damping), offset, measurement point identification (8 characters), output simulation Approvals marked Unit complies with the legal requirements set forth by the EU regulations. UL Recognized Component General Purpose and non-incendive for use in hazardous locations Class I, Division 2 Groups A, B, C and D TT-10 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/pyromation.php 800-876-0036 847-356-0566 312-7

Configuration Code TM01 Series 442 Programmable HART Temperature Transmitter The Series 442 programmable HART temperature transmitter is a 2-wire transmitter with an analog output. It has measurement input for resistance thermometers (RTD) in 2-, 3- or 4-wire connections, thermocouples, resistance and voltage inputs. The transmitter can be programmed with a PC or HART protocol hand-held terminal. These small units can be mounted in Pyromation DIN (Form B) connection heads, or they can be used for surface mounting by using a 35 mm DIN-rail mounting clip. TEMPERATURE HEAD TRANSMITTER Intrinsically safe universal head transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage inputs, programmable using HART protocol, for installation in a sensor head (Form B). Features and Benefits protocol for various signals. and non-incendive for HART Communication Foundation 314-8 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/pyromation.php 800-876-0036 847-356-0566 TT-11

Configuration Code TM01 Series 442 Programmable HART Temperature Transmitter ORDER S Unconfigured Order Number: Example Configured Order Number: 442-00 [1] 4 4 2 1 2 3-1 J U - 4 5 F S (50-300) 1 1 Thermocouple (TC) 2 RTD (2-wire) 3 RTD (3-wire) 4 RTD (4-wire) 3 U D 2 J Type J thermocouple K Type K thermocouple T Type T thermocouple N Type N thermocouple E Type E thermocouple R Type R thermocouple S Type S thermocouple B Type B thermocouple 85-1 ) 55-1 ) 95-1 ) MV Millivolts W Resistance 4 RANGE S ( lower limit upper limit) 5 C Celsius F Fahrenheit Accessories 10307 35 mm DIN rail mounting clip [1] Default setting for unconfigured transmitters is Communication Foundation TT-12 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/pyromation.php 800-876-0036 847-356-0566 315-8

Series 442 Programmable HART Temperature Transmitter Specifications INPUT Resistance Thermometer (RTD) TYPE MEASUREMENT RANGE MINIMUM RANGE o C -1 ) Pt1000 o C -1 ) Ni1000 Connection Type t Resistance ( ) TYPE MEASUREMENT RANGE MINIMUM RANGE Thermocouples (TC) TYPE MEASUREMENT RANGE MINIMUM RANGE K (NiCr-Ni) N (NiCrSi-NiSi) Voltage (mv) TYPE MEASUREMENT RANGE MINIMUM RANGE 316-6 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/pyromation.php 800-876-0036 847-356-0566 TT-13

Series 442 Programmable HART Temperature Transmitter Specifications OUTPUT Output (Analog) Output signal Transmission as Maximum load Digital filter 1st degree Induced current required Current limit Switch on delay Electronic response time (4 to 20) ma or (20 to 4) ma Temperature linear, resistance linear, voltage linear (V power supply - 11.5V) / 0.022 A current output) (0 to 60) s 4 s (during power up I a = 3.8 ma) 1 s Failure Mode Undershooting measurement range Exceeding measurement range Sensor breakage/short circuit [1] [1] Not for thermocouple Decrease to 3.8 ma Increase to 20.5 ma Electrical Connection Power supply Galvanic isolation (In/out) Allowable ripple U b = (11.5 to 30) V dc, polarity protected Û = 2 kv ac U ss b max = 1 khz ACCURACY Reference conditions Calibration temperature (23 ± 5) o C [73 ± 9] o F Resistance Thermometer (RTD) TYPE MEASUREMENT ACCURACY Pt100, Ni100 Pt500, Ni500 Pt1000, Ni1000 ± 0.2 C or 0.08% [2] ± 0.5 C or 0.20% [2] ± 0.3 C or 0.12% [2] Resistance ( ) TYPE MEASUREMENT ACCURACY MEASUREMENT RANGE Resistance [2] [2] [2] % is related to the adjusted measurement range (the value to be applied is the greater) HART is a registered trademark of HART Communication Foundation TT-14 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/pyromation.php 800-876-0036 847-356-0566 317-8

Series 442 Programmable HART Temperature Transmitter Specifications ACCURACY (continued) Thermocouple (TC) TYPE MEASUREMENT ACCURACY [1] K, J, T, E, L, U N, C, D S, B, R MoRe5-MoRe41 ± 0.5 C or 0.08% ± 1.0 C or 0.08% ± 2.0 C or 0.08% Influence of the internal reference junction Pt100 ± (0.30 + 0.005 t ) C t = value of temperature without regard to sign C Voltage (mv) TYPE MEASUREMENT ACCURACY MEASUREMENT RANGE Millivolt (mv) ± 20 μv or 0.08% [1] (-10 to 100) mv General Accuracy Influence of power supply ± 0.01%/V deviation from 24 V [2] Load influence [2] Resistive thermometer (RTD): T d Temperature drift Resistive thermometer Pt100: T d Thermocouple (TC): T d = Deviation of the ambient temperature according to the reference condition Long term stability [3] [1][3] [1] % is related to the adjusted measurement range (the value to be applied is the greater) [2] All data is related to a measurement end value of 20 ma [3] Under reference conditions INSTALLATION CONDITIONS Ambient Conditions Ambient temperature (-40 to 85) C [-40 to 185] F Storage temperature (-40 to 100) C [-40 to 212] F Climatic class To EN 60 654-1, Class C Moisture condensation Allowable Vibration protection 4 g / (2 to 150) Hz according to IEC 60 068-2-6 EMC immunity Interference immunity and interference emission as per EN 61 326-1 (IEC 1326) HART is a registered trademark of HART Communication Foundation 318-8 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/pyromation.php 800-876-0036 847-356-0566 TT-15

Series 442 Programmable HART Temperature Transmitter Specifications MECHANICAL CONSTRUCTION 0.197 [5] DIMENSIONS IN INCHES [mm] Dimensions 0.28 [7] 1.3 [33] 1.73 [44] 0.89 [23] Weight approximately 40 g Materials Terminals 15 AWG (maximum) Terminal Connections Power supply and current output HART Communication on (4 to 20) ma 2 (-) (11.5 to 30) V dc 1 (+) (4 to 20) ma Sensor Connection 6 2-Wire 3-Wire 4-Wire 5 4 3 Remote Operation Configurable parameters Sensor type and connection type, engineering units ( C/ F), measurement range, internal/external cold junction compensation, cable resistance compensation on 2-wire connection, fault conditioning, output signal (4 to 20) ma or (20 to 4) ma, digital filter (damping), offset, measurement point identification (8 characters), output simulation Approvals marked Unit complies with the legal requirements set forth by the EU regulations. UL Recognized Component General Purpose and non-incendive for use in hazardous locations Class I, Division 2 Groups A, B, C and D HART is a registered trademark of HART Communication Foundation TT-16 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/pyromation.php 800-876-0036 847-356-0566 319-7

Series 450 Programmable Integral Temperature Transmitter SERIES 450 PROGRAMMABLE INTEGRAL TEMPERATURE TRANSMITTER Application Areas Features and Benefits Distributed By: M&M Control Service, Inc. www.mmcontrol.com/pyromation.php 800-876-0036 847-356-0566 TT-17

Series 450 Programmable Integral Temperature Transmitter MINIATURE CIP RTD ASSEMBLY M12 CONNECTOR 2 11/16" X See Food & Dairy Section For Ordering Information AUTHORIZED 74- AUTHORIZED 74- CIP RTD ASSEMBLY 2 11/16" X M12 CONNECTOR 1 1/4" See Food & Dairy Section For Ordering Information RTD ASSEMBLY WITH NO PROCESS FITTING M12 CONNECTOR 2 7/8" X See RTD Section For Ordering Information RTD ASSEMBLY WITH THREADED CONNECTION M12 CONNECTOR 3" X See RTD Section For Ordering Information TT-18 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/pyromation.php 800-876-0036 847-356-0566 340-4

Series 450 Programmable Integral Temperature Transmitter Specifications INPUT Resistance Thermometer Input (RTD) TYPE MEASUREMENT RANGE MINIMUM RANGE Connection Type 4 wire connection (standard) Sensor current OUTPUT Output (Analog) Output signal Transmission as Maximum load Induced current required Current limit Switch on delay Electronic response time (4 to 20) ma or (20 to 4) ma Temperature linear (V power supply - 10 V) / 0.023 A (current output) 2 s 1 s Failure Mode Undershooting measurement range Exceeding measurement range Sensor breakage/short circuit ACCURACY Accuracy Electronics measurement error Reference conditions Sensor measurement error 0.1 Class A Class B Grade B Class AA Influence of power supply Load influence Temperature drift Electronics long term stability T d º º 341-4 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/pyromation.php 800-876-0036 847-356-0566 TT-19

Series 450 Programmable Integral Temperature Transmitter Specifications Electrical Connection 3 1 (10 to 35) V dc (4 to 20) ma Electrical connection Power supply Allowable ripple Electrical connection of the compact thermometer (view from above) - M12 plug, 4-pin Pin 1: Power supply (10 to 35) V dc; Current output (4 to 20) ma Pin 2: PC configuration cable connection Pin 3: Power supply 0 V dc; current output (4 to 20) ma Pin 4: PC configuration cable connection U b = (10 to 35) V dc, polarity protected U ss b max = 1 khz Environmental Conditions Ambient Temperature Storage Temperature Climatic Class EN 60 654-1, class C Condensation Permitted Ingress protection IP 67 Shock resistance 4g / (2 to 150) Hz as per IEC 60 068-2-6 EMC immunity Interference immunity and interference emission as per EN 61 326-1 (IEC 1326) Process Process temperature limit MAXIMUM AMBIENT MAXIMUM PROCESS Approvals UL Recognized Component 3-A Sanitary Council Standard 74- (CIP sensors only) AUTHORIZED 74- TT-20 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/pyromation.php 800-876-0036 847-356-0566 342-3

Configuration Code TM01 Series 642 Programmable HART Transmitter Field Temperature Transmitter The Series 642 programmable HART protocol handheld limit value violation indicator. PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER Programmable temperature transmitter for resistance thermometers (RTDs), thermocouples, resistance inputs and voltage inputs: adjustable via HART protocol. Application Areas protocol for converting various input signals to an analog, scaleable (4 to 20) ma output signal Resistance thermometer (RTD) Thermocouples (TC) Voltage input (mv) protocol for operating the device on site using a handheld communicator or HART is a registered trademark of HART Communication Foundation Features and Benefits protocol for various input signals marked 381-4 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/pyromation.php 800-876-0036 847-356-0566 TT-21

Configuration Code TM01 Series 642 Programmable HART Field Temperature Transmitter ORDER S Example Order Number: 1-0 642A 1-1 1-2 1-3 1-4 - D - 3 85 U - 1-5 1-6 C S(0-200) 1-0 Transmitter Type 642C 642F Field Transmitter with generalpurpose aluminum housing Field Transmitter with Field Transmitter with general- 1-6 Unit of Measure C Celsius F Fahrenheit K Kelvin 1-5 Range S (lower limit upper limit) 1-4 Failure Mode 1-1 Options T D 1-2 Input Type 00 [1] 1 Thermocouple (TC) or millivolt 2 RTD (2-wire) or resistance 3 RTD (3-wire) or resistance 4 RTD (4-wire) or resistance Accessories 10321 Solid cover Glass cover with digital display [1] Default setting for unconfigured transmitter is 3-wire Pt100 (0-100) C Pipe mounting bracket for use on pipes U D 1-3 Sensor Type J Type J thermocouple K Type K thermocouple T Type T thermocouple N Type N thermocouple E Type E thermocouple R Type R thermocouple S Type S thermocouple B Type B thermocouple 85-1 ) 55 500 ohm platinum -1 ) 95-1 ) MV Millivolts W Resistance Communication Foundation TT-22 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/pyromation.php 800-876-0036 847-356-0566 382-5

Series 642 Programmable HART Field Temperature Transmitter Specifications INPUT Resistance Thermometer (RTD) TYPE STANDARDS MEASUREMENT RANGE MINIMUM RANGE o C -1 ) Pt200 ASTM E1137 Pt1000 SAMA Ni100 Ni1000 Cu100 ( Polynomial RTD Pt100 (Callendar - van Dusen) Connection type Sensor current Edison Curve GOST Resistance ( ) TYPE MEASUREMENT RANGE MINIMUM RANGE Thermocouples (TC) (ASTM E230) TYPE MEASUREMENT RANGE MINIMUM RANGE E (NiCr-CuNi) K (NiCr-Ni) N (NiCrSi-NiSi) T (Cu-CuNi) U (Cu-CuNi) Cold junction Cold junction accuracy 10 k Voltage (mv) TYPE MEASUREMENT RANGE MINIMUM RANGE Millivolt (mv) (-20 to 100) mv HART 383-3 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/pyromation.php 800-876-0036 847-356-0566 TT-23

Series 642 Programmable HART Field Temperature Transmitter Specifications OUTPUT Output (Analog) Output signal Transmission as Maximum load Digital filter 1st degree Induced current required Current limit Switch on delay Response time Analog (4 to 20) ma or (20 to 4) ma Temperature linear, resistance linear, voltage linear (V power supply - 11V) / 0.022 A (current output) (0 to 60) s 4 s (during switch-on operation I a = 4 ma) 1 s Failure Mode Undershooting measurement range Exceeding measurement range Sensor breakage/short circuit Decrease to 3.8 ma Electrical Connection Power supply Cable entry Allowable ripple U b = 11 to 40 V (8 to 40 without display), reverse polarity protected Three 1/2" NPT openings U ss b max = 1 khz ACCURACY Reference conditions o C [73.4 ± 9] o F Resistance Thermometer (RTD) TYPE MEASUREMENT ACCURACY - DIGITAL MEASUREMENT ACCURACY - D/A [1] Cu100, Pt100, Ni100, Ni120 Cu10, Pt200 ± 0.2 C [0.36 F] ± 0.6 C [1.08 F] ± 0.4 C [0.72 F] ± 2 C [3.6 F] [1] % relates to the set span. Accuracy = digital + D/A accuracy ± 0.02% ± 0.02% ± 0.02% ± 0.02% Thermocouple (TC) TYPE MEASUREMENT ACCURACY - DIGITAL MEASUREMENT ACCURACY - D/A [1] K, J, T, E, L, U N, C, D S, B, R Resistance ( ) TYPE MEASUREMENT ACCURACY - DIGITAL MEASUREMENT ACCURACY - D/A [1] MEASUREMENT RANGE Resistance Typical ± C [0.9 F] Typical ± 1 C [0.18 F] Typical ± 2 C [3.6 F] ± 0.02% ± 0.02% ± 0.02% ± 0.08 ± 0.02% ± 1.6 ± 0.02% Voltage (mv) TYPE MEASUREMENT ACCURACY - DIGITAL MEASUREMENT ACCURACY - D/A [1] MEASUREMENT RANGE Voltage ± 20 μv ± 0.02% (20 to 100) mv HART is a registered trademark of HART Communication Foundation TT-24 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/pyromation.php 800-876-0036 847-356-0566 384-3

Series 642 Programmable HART Field Temperature Transmitter Specifications ACCURACY (continued) Physical input range of the sensors TYPE MEASUREMENT ACCURACY [1] Cu10, Cu50, Cu100, polynomial RTD, Pt50, Pt100, Ni100, Ni120 (10 to 2000) Pt200, Pt500, Pt1000, Ni1000 (-20 to 100) mv Thermocouple type: C, D, E, J, K, L, N (-5 to 30) mv Thermocouple type: B, R, S, T, U [1] % is related to the adjusted measurement range (the value to be applied is the greater) General Repeatability Load influence Long term stability 0.03% of the physical input range (15 Bit) Resolution A/D conversion: 18 Bit Date under reference conditions. % relates to the set span. The larger value applies. Temperature Drift Total temperature drift = input temperature drift + output temperature drift Effect on the accuracy when ambient temperature changes by 1 C [1.8 Input (10 to 400) 0.002% of measured value Input (10 to 2000) 0.002% of measured value Input (-20 to 100) mv Input (5 to 30) mv Output (4 to 20) ma typ. 0.002% of measured value (maximum value = 1.5 x typical) typ. 0.002% of measured value (maximum value = 1.5 x typical) typ. 0.002% of measured value (maximum value = 1.5 x typical) INSTALLATION CONDITIONS Ambient Conditions Ambient temperature With display: NOTE: The display can react slowly for temperature < -20 C [< -4 Storage temperature Allowable Altitude 6500 ft. above sea level Climatic class As per EN 60 654-1, Class C Moisture condensation Allowable Shock and vibration protection 3 g / (2 to 150) Hz according to IEC 60 068-2-6 EMC immunity Interference immunity and interference emission as per EN 61 326-1 (IEC 1326) (0.08 to 2) GHz 10 V/m; (1.4 to 2) GHz 30 V/m to EN 61 000-4-3 Protection (when specified) HART is a registered trademark of HART 385-3 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/pyromation.php 800-876-0036 847-356-0566 TT-25

Series 642 Programmable HART Field Temperature Transmitter Specifications INTERFACE Display Elements 10 20 40 30 50 60 70 K F C %! 80 90 Item 1: Bar graph display in 10% increments with indicators for overranging / underranging Item 2: Caution display 0 100 Item 3: Unit display K, F, or C or % Item 4: Measured value display (digit height 20.5 mm / 0.81 ) Item 5: Status and information display Item 6: Communication display Item 7: Programming disabled display LC display of the field transmitter (illuminated, can be rotated in 90 increments) Operating Elements No operating elements are present directly on the display. The device parameters of the field transmitter are configured using the handheld communicator or a PC with HART Modem and operating software TransComm Light. Remote Operation Interface Configurable device parameters HART communication via transmitter power supply Sensor type and connection type, engineering units ( C/ F), measurement ranges, internal/external cold junction compensation of wire resistance with 2-wire connection, failure mode, output signal (4 to 20) ma (20 to 4) ma, digital filter (damping), offset, TAG+descriptor (8+16 characters), output simulation, customized linearization, recording of min./max process value, analog output: Option: customized linearization STANDARDS Approvals marked Unit complies with the legal requirements set forth by the EU regulations. Intrinsically safe and non-incendive or explosion proof for hazardous locations Class I, Division 1 and 2, Groups A, B, C and D Other standards and guidelines IEC 60 529: Degrees of protection through housing (IP code) IEC 61 010: Protection measures for electrical equipment for measurement, control, regulation and laboratory procedures IEC1326: Electromagnetic compatibility (EMC requirements) HART is a registered trademark of HART Communication Foundation TT-26 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/pyromation.php 800-876-0036 847-356-0566 386-3

Series 642 Programmable HART Field Temperature Transmitter Specifications MECHANICAL CONSTRUCTION 5.2 [132] DIMENSIONS IN INCHES [mm] 4.8 [121] Dimensions 5.3 [135] 0.25 [6.4] 4.8 [121] 4.4 [112] 4.2 [106] Display rotatable in 90 increments Weight approximately 1.6 kg [3.53 lb] Materials Housing: die-cast aluminum with powder coating Terminals Cables / wires up to max. 2.5 mm 2 (AWG 13) Terminal Connections HART Communication on (4 to 20) ma Optional Mounting Bracket Part Number: 10321 Designed for use on pipes with a diameter between 1.5" to 3.3". The additonal mounting plate must be used for pipes with a diameter of 1.5" to 2.2". No plate is required for pipes with a diameter of 2.2" to 3.3". Assembly includes bracket, screws, and mounting plate. HART is a registered trademark of HART Communication Foundation 387-4 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/pyromation.php 800-876-0036 847-356-0566 TT-27

Series 642 Field Temperature Transmitter Configuration sheet for Series 642 temperature transmitter For customer specific setup Sensor TC ( ) B ( ) C ( ) D ( ) E ( ) J ( ) K ( ) L ( ) N ( ) R ( ) S ( ) T ( ) U RTD ( ) Pt100 ( ) Pt500 ( ) Pt1000 ( ) Ni100 ( ) Ni500 ( ) Ni1000 ( ) mv ( ) (10 to 400) Ohm ( ) (10 to 2000) Ohm ( ) 2-wire ( ) 3-wire ( ) 4-wire Unit ( ) C ( ) F ( ) K ( ) mv ( ) Ohm Range Lower limit. Upper limit. Note: Must meet minimum space requirements Expanded setup Reference junction/tc only ( ) internal ( ) external (0 to 80) ºC (32 to 17) ºF Compensation wire resistance S1 (0 to 30) Ohm Failure mode ( ) < 3.6 ma ( ) > 21.0 ma Output ( ) ( 4 to 20 ) ma ( )(20 to 4)mA Filter (0 to 60) s Offset S1. (-10 to 10) ºC [-18 to 18] ºF Line voltage filter ( ) 50 Hz ( ) 60 Hz TAG 16 characters max. TT-28 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/pyromation.php 800-876-0036 847-356-0566 388-2

Configuration Code TM01 T82 Programmable HART Transmitter Temperature Transmitter The T82 programmable HART The T82 can be programmed using a HART PROGRAMMABLE DUAL INPUT TEMPERATURE TRANSMITTER Programmable temperature transmitter for resistance thermometers (RTDs), thermocouples, resistance inputs and voltage inputs: adjustable via HART protocol. Application Areas and HART protocol for converting various input signals to an analog, scaleable (4 to 20) ma output signal Resistance thermometer (RTD) Thermocouples (TC) Voltage input (mv) protocol for operating the device on site using a handheld communicator Features and Benefits protocol for various input signals HART marked 2013 Pyromation, Inc. 466-1 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/pyromation.php 800-876-0036 847-356-0566 TT-29

Configuration Code TM01 T82 Programmable HART Temperature Transmitter ORDER S 1-0 1-1 Example Order Number: 33 36T82-D10 - - 85-85 - E - U 1-4 1-5 1-6 1-7 - S(0-200) C 1-0 Transmitter Type purpose screw-cover housing 1-1 Con guration Input 00 4T TT 1-2 Sensor Input Channel 1 J K T N E R S B 85-1 ) 55-1 ) 95-1 ) 1-6 Range S 1-5 Failure Mode 1-7 Unit of Measure C F Celsius Fahrenheit U D 1-4 Input Set-ups B C D E 1-3 Sensor Input Channel 2 00 No second channel J K T N E R S B 85-1 ) 55-1 ) 95-1 ) 2013 Pyromation, Inc. TT-30 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/pyromation.php 800-876-0036 847-356-0566 467-1

T82 Programmable HART Temperature Transmitter Specifications INPUT Resistance Thermometer (RTD) TYPE STANDARD MEASUREMENT RANGE MINIMUM RANGE o C -1 ) Pt200 Pt1000 Ni100 Ni120 IPTS-68 Pt100 (Callendar van Dusen) Nickel polynomial Copper polynomial The measuring range limits are specified by entering the limit values that depend on the coefficients A to C and R O Resistance ( ) TYPE MEASUREMENT RANGE MINIMUM RANGE Thermocouples (TC) TYPE STANDARD MEASUREMENT RANGE E (NiCr-CuNi) K (NiCr-Ni) N (NiCrSi-NiSi) S (PtRh10-Pt) T (Cu-CuNi) RECOMMENDED TEMPERATURE RANGE MINIMUM RANGE U (Cu-CuNi) Cold junction resistance Voltage (mv) 10 k TYPE MEASUREMENT RANGE MINIMUM RANGE Millivolt (mv) (-20 to 100) mv HART 2013 Pyromation, Inc. 468-1 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/pyromation.php 800-876-0036 847-356-0566 TT-31

T82 Programmable HART Temperature Transmitter Specifications OUTPUT Output (Analog) Output signal Transmission as Maximum load Digital filter 1st degree Minimum current required Current limit Switch on delay Response time Failure Mode Underranging Overranging Failure, e.g. sensor breakage; sensor short circuit Electrical Connection Supply Voltage Entry Residual Analog (4 to 20) ma or (20 to 4) ma Temperature linear, resistance linear, voltage linear (U b max - 11V) / 0.023 A (current output) (0 to 120) s 3.5 ma, multidrop mode 4 ma 10 s (during switch-on operation I a 3.8 ma) Resistance thermometer (RTD) Thermocouples (TC) Reference temperature Linear drop from 4.0 ma to 3.8 ma Linear increase from 20.0 ma to 20.5 ma 0.9 to 1.2 s (depends on the connection method 2/3/4-wire) 0.7 s 0.5 s locations U ss b max ACCURACY Calibration temperature (25 ± 5) o C [77 ± 9] o F Reference conditions Supply voltage: 24 V dc 4-wire circuit for resistance adjustment Resistance Thermometer (RTD) TYPE MEASUREMENT ACCURACY - DIGITAL [1] MEASUREMENT ACCURACY - D/A [2] 0.1 C [0.18 F] 0.3 C [0.54 F] 0.2 C [0.36 F] 1.0 C [1.8 F] [1] Using HART transmitted measured value [2] % refers to the set span. Accuracy of current output = digital + D/A accuracy 0.03% 0.03% 0.03% 0.03% Thermocouple (TC) TYPE MEASUREMENT ACCURACY - DIGITAL [1] MEASUREMENT ACCURACY - D/A [2] K, J, T, E, L, U N, C, D S, B, R Resistance ( ) TYPE MEASUREMENT ACCURACY - DIGITAL [1] MEASUREMENT ACCURACY - D/A [2] MEASUREMENT RANGE Resistance 0.25 C [0.45 F] 0.5 C [0.9 F] 1.0 C [1.8 F] 0.03% 0.03% 0.03% ± 0.04 0.03% ± 0.8 0.03% Voltage (mv) TYPE MEASUREMENT ACCURACY - DIGITAL [1] MEASUREMENT ACCURACY - D/A [2] MEASUREMENT RANGE Voltage ± 10 μv 0.03% (-20 to 100) mv HART is a registered trademark of HART Communication Foundation 2013 Pyromation, Inc. TT-32 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/pyromation.php 800-876-0036 847-356-0566 469-1

T82 Programmable HART Temperature Transmitter Specifications ACCURACY (continued) Physical input range of the sensors Cu50, Cu100, polynomial RTD, Pt50, Pt100, Ni100, Ni120 (10 to 2000) Pt200, Pt500, Pt1000 (-20 to 100) mv Thermocouple type: B, C, D, E, J, K, L, N, R, S, T, U General Load influence Influence of ambient temperaure (temperature drift) Total temperature drift = input temperature drift + output temperature drift Output (4 to 20) ma μv INSTALLATION CONDITIONS Ambient Conditions Storage temperature Altitude Humidity Protection documentation) 2 kv 10 V HART 2013 Pyromation, Inc. 470-1 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/pyromation.php 800-876-0036 847-356-0566 TT-33

T82 Programmable HART Temperature Transmitter Specifications INTERFACE Display Elements 1 2 3 4 5 6 7 Item 1: Displays the TAG Item 2: 'Communication' symbol Item 3: Unit display Item 4: Measured value display Item 5: Value/channel display S1, S2, DT, PV, I, % Item 6: 'Configuration locked' symbol Item 7: Status signals Remote Operation Interface Configurable device parameters HART (Version 6) communication via transmitter power supply Sensor type and connection type, engineering units ( C/ F), measurement ranges, internal/external cold junction compensation of wire resistance with 2-wire connection, failure mode, output signal (4 to 20) ma (20 to 4) ma, digital filter (damping), offset, TAG+descriptor (8+16 characters), output simulation, analog output: option: customized linearization APPROVALS Approvals marked Unit complies with the legal requirements set forth by the EU regulations. Intrinsically safe and non-incendive Class I, Division 1 and 2, Groups A, B, C and D HART is a registered trademark of HART Communication Foundation 2013 Pyromation, Inc. TT-34 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/pyromation.php 800-876-0036 847-356-0566 471-1

T82 Programmable HART Temperature Transmitter Specifications MECHANICAL CONSTRUCTION 3.80 [96] 0.18 [4] Dimensions 4.53 [115] 0.27 [7] 1.30 [33] 1.73 [44] 0.95 [24] 0.82 [21] 1.97 [50] Weight Materials Terminals Housing, transmitter, and display: approximately 970 g (2 1/4 lbs) Transmitter only: approximately 50 g (1/4 lb) Housing: die-cast aluminum with powder coating 15 AWG Maximum Terminal Connections 6 7 5 1 (+) 4 2 (-) 3 DISPLAY CONNECTION TC 2 WIRE 3 WIRE 4 WIRE RTD OR RTD OR RTD OR SINGLE (INPUT 1) + - (5) (6) WHITE RED (4) (6) WHITE RED (4) (6) WHITE RED RED (4) (5) (6) WHITE RED RED (4) (5) (6) WHITE WHITE RED RED (3) WHITE (3) (4) WHITE (4) (5) (6) RED RED (5) (6) DUPLEX (INPUT 2) 2 1 + - + - (7) (6) (5) (6) WHITE GREEN BLACK RED (4) (3) 1 2 1 2 (6) (6) WHITE GREEN BLACK RED (4) (3) (6) (6) WHITE GREEN BLACK BLACK RED RED (4) (3) 1 2 1 2 (6) (7) (5) (6) WHITE GREEN BLACK BLACK RED RED (4) (3) (6) (7) (5) (6) HART is a registered trademark of HART Communication Foundation 2013 Pyromation, Inc. 472-1 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/pyromation.php 800-876-0036 847-356-0566 TT-35