TS-EPS Installation Instructions

Similar documents
DC400 Dispensing Cutoff System

AXIS 205 Network Camera Quick Installation Guide

UDS2100 Quick Start Guide

Gigabit Content Security Router CS-5800

P Quick Start Guide. VoIP Analog Telephone Adaptor DEFAULT LOGIN. IP Address Password Version /2007 Edition 1

Quick Start Guide. RV 120W Wireless-N VPN Firewall. Cisco Small Business

Quick Start Guide. RV0xx Series Routers

Installing Your Vonage Device in Front of an Existing Router for customers with DSL INTERNET SERVICE

ON HOLD ANNOUNCER. Once you receive your audio announcer, check the packaging to ensure that all of the following items are enclosed:

Quick Setup Guide - AirStation WHR-G54S Wireless Cable/DSL Smart Router

Comtrend 1 Port Router Installation Guide CT-5072T

Application Note Configuring the UGate 3000 for use with ClipMail Pro and ClipExpress

GSC/VRC IP Converter. Installation and Operation Manual

UPS Network Interface. Quick InstallationGuide

Quick Start Guide. WRV210 Wireless-G VPN Router with RangeBooster. Cisco Small Business

Quick Start Guide. Cisco SPA232D Mobility Enhanced ATA

OfficeConnect Internet Firewall 25 Internet Firewall DMZ. QuickStart Guide (3C16770, 3C16771)

DSL Installation Guide

Chapter 1 Installing the Gateway

ProSAFE 8-Port and 16-Port Gigabit Click Switch

Unpacking the Product. Rack Installation. Then, use the screws provided with the equipment rack to mount the firewall in the rack.

Multi-Homing Dual WAN Firewall Router

Firewall VPN Router. Quick Installation Guide M73-APO09-380

DVG-2101SP VoIP Telephone Adapter

P-791R v2. Quick Start Guide. G.SHDSL.bis Router DEFAULT LOGIN. Administrator Password User Password. Version /2007 Edition 1

ethernet connection For more information about the printer's ethernet feature, click the topic below: ethernet lights network configuration page

3.5 EXTERNAL NETWORK HDD. User s Manual

Actiontec GT784WN Router

BEC 6200WZL. 4G/LTE Cellular Broadband Router. Quick Start Guide

P-660HN n Wireless ADSL2+ 4-port Gateway DEFAULT LOGIN DETAILS. Firmware Version 1.10 Edition 1, 9/2010. IP Address:

Wireless Router Setup Manual

Chapter 3 Connecting the Router to the Internet

AXIS 205 Network Camera Goes anywhere your network goes

Linksys Gateway SPA2100-SU Manual

Router Setup Manual. NETGEAR, Inc Great America Parkway Santa Clara, CA USA

ASUS WL-5XX Series Wireless Router Internet Configuration. User s Guide

Check Your Package Contents. CD-ROM containing Manual and Warranty

User Manual. EtherUSB

Chapter 10 Troubleshooting

Cisco 831 Router and Cisco SOHO 91 Router Cabling and Setup Quick Start Guide

Broadband Phone Gateway BPG510 Technical Users Guide

P-660HWP-Dx. Quick Start Guide g HomePlug AV ADSL2+ Gateway. Version /2007 Edition 1. Copyright All rights reserved.

Application & Quick-Start Guide

IP DSLAM IDL Quick Installation Guide

Prestige 660R-6x Read Me First

SOHO 6 Wireless Installation Procedure Windows 95/98/ME with Internet Explorer 5.x & 6.0

RouteFinder SOHO. Quick Start Guide. SOHO Security Appliance. EDGE Models RF825-E, RF825-E-AP CDMA Models RF825-C-Nx, RF825-C-Nx-AP

KNX IP Interface. Operating and installation manual

(IR) Bullet LPR/ANPR Network Camera

Connecting the DG-102S VoIP Gateway to your network

Quick Start Guide. WAP371 Wireless AC/N Dual Radio Access Point with Single Point Setup Quick Start Guide. Cisco Small Business

UDS-10, UDS100, UDS200 Quick Start Guide Copyright Lantronix is a trademark of Lantronix. All rights reserved Rev.

DOORKING SYSTEMS 1830 SERIES NETWORK WORKSHOP LAN APPLICATIONS ACCESS CONTROL SOLUTIONS LOCAL AREA NETWORK (LAN) CONNECTION REV 04.

User Manual. Sipura SPA-2100 ATA with PC Router. January 2005 v1. Linhagratuita grupo csdata

Connecting to the Internet. LAN Hardware Requirements. Computer Requirements. LAN Configuration Requirements

Ethernet Radio Configuration Guide

Dominion KX II-101-V2

Quick Installation Guide DSL-2640U. Wireless N 150 ADSL2+ Modem Router

Comtrend 4 Port Router Installation Guide CT-5361T

Phone Adapter. with 2 Ports for Voice-over-IP. Installation and Troubleshooting Guide. Model No. PAP2 Ver. 2. Voice

Prestige 2002 Series. VoIP Analog Telephone Adaptor. Quick Start Guide

PePWave Surf Series PePWave Surf Indoor Series: Surf 200, AP 200, AP 400

P-660R-D Series. ADSL2+ Router. Quick Start Guide. Version /2006 Edition 1

KNX IP INTERFACE IN00A02IPI. Operating and installation manual

Broadband Router ESG-103. User s Guide

Manual. IP Sensor and Watchdog IPSW2210. I P S W M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

P-660HNU-Tx. Wireless N ADSL2+ 4-port Gateway DEFAULT LOGIN DETAILS. Firmware v1.02 Edition 1, 11/2011. IP Address:

Contents. Section A Networking Basics Learning the Basics Section B Wired Ethernet Networking... 17

ADSL MODEM. User Manual V1.0

Web Power Switch III User s Guide Revision LPC-3

ETHERNET WEATHER STATION CONNECTIONS Application Note 33

Quick Setup Guide High Power Wireless Ethernet Converter WLI-TX4-G54HP

APPLICATION NOTE. Ethernet Configuration Guide for D-500 D-700

DIR-100. Before You Begin. Check Your Package Contents. Triple Play Router

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

SAGEM TM 1201/1241 V2

GWA501 package contains: 1 Wireless-G Broadband Gateway 1 Power Adapter 1 Ethernet Cable 1 Manual CD 1 Quick Start Guide 1 Warranty/Registration Card

< Introduction > This technical note explains how to connect New SVR Series to DSL Modem or DSL Router. Samsung Techwin Co., Ltd.

GWA502 package contains: 1 Wireless-G Broadband Router 1 Power Adapter 1 Ethernet Cable 1 Manual CD 1 Quick Start Guide 1 Warranty/Registration Card

Quick Installation Guide DVG-N5402SP VoIP Router

Quick-Start Guide 007-SE Gigaset. Residential Wireless Gateway SE567/SE568. Gigaset Communications GmbH is a trademark licensee of Siemens AG

How To Connect An Ipad To A Speedtouch 546 With A Dsl Internet Connection On A Pc Or Ipad (For A Sim Sim) On A Powerline Or Ipa (For An Ipa) On An Ipod Or

Installation & Operations Manual

2 Setting Up the Hardware for a Wired Ethernet Network Setting Up the Software for an Ethernet Network... 21

Quick Installation Guide DSL-2750U/NRU. 3G/ADSL/Ethernet Router with Wi-Fi and Built-in Switch

ADSL Router Quick Installation Guide Revised, edited and illustrated by Neo

Quick Installation Guide. Live! Titanium

Prestige 202H Plus. Quick Start Guide. ISDN Internet Access Router. Version /2004

EDGE FX Network configuration

IP Power Stone 4000 User Manual

SLC 5/05 Processors Firmware/Operating System ControlFLASH Upgrade

Quick Start Guide. Cisco Small Business. 200 Series 8-Port Smart Switches

GUIDE. CTRLink. EIPR Skorpion Wired and Wireless IP Routers. EIPR Series

Configuring a customer owned router to function as a switch with Ultra TV

Chapter 1 Connecting the Router to the Internet

M3 ORANGE single-slot Cradle. User Guide. Product Number: A-1CR-US0D-030-R00, A-1CR-U0ED-030-R00. Compatible Device(s): M3 ORANGE

Honeywell Internet Connection Module

Quick Start Guide. Cisco Small Business. 300 Series Managed Switches

Wireless LAN g USB Adapter

NeoGate TA Series Installation Guide

Transcription:

TS-EPS Installation Instructions Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Tel: +1 608 838 8786 800 225 9787 Fax: +1 608 838 6433 www.franklinfueling.com

Contents Important Safety Messages...3 Introduction...4 Scope...4 Abbreviations and Acronyms...4 Tools and Supplies Needed...4 Hardware Installation...4 Network Configurations...5 Frame Relay Networks...5 Cable/DSL Connections...5 Programming...6 Programming an TS-EPS using the Port Server Utility and Internet Explorer... 6 SSA Settings...7 TS-EPS Diagnostics...8 Notice FFS reserves the right to change this document and specifications at any time without notice. FFS makes no expressed or implied warranty with regard to the contents of this manual. FFS assumes no liability for errors or omissions, or for any damages, direct or consequential, that result from the use of this document or the equipment that it describes. Contacting Franklin Fueling Systems (FFS) Please feel free to contact us by mail at: Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Or contact us by phone, fax or e-mail: Tel: +1 800 984-6266 E-mail: sales@franklinfueling.com Fax: +1 608 838 6433 techserve@franklinfueling.com International Tel: México 001 800 738 7610 Technical Service Hours: 7am to 7pm CST - Monday through Friday Please visit our web site at www.franklinfueling.com Copyright 2012 by Franklin Fueling Systems. No part of this publication may be reproduced in any form without the prior written consent of FFS. All rights reserved. 2

Important Safety Messages FFS equipment is designed to be installed in association with volatile hydrocarbon liquids such as gasoline and diesel fuel. Installing or working on this equipment means working in an environment in which these highly flammable liquids may be present. Working in such a hazardous environment presents a risk of severe injury or death if these instructions and standard industry practices are not followed. Read and follow all instructions thoroughly before installing or working on this, or any other related equipment. As you read this guide, please be aware of the following symbols and their meanings. Warning Caution Danger This symbol identifies a warning. A warning sign will appear in the text of this document when a potentially hazardous situation may arise if the instructions that follow are not adhered to closely. A potentially hazardous situation may involve the possibility of severe bodily harm or even death. This is a caution symbol. A caution sign will appear in the text of this document when a potentially hazardous environmental situation may arise if the instructions that follow are not adhered to closely. A potentially hazardous environmental situation may involve the leakage of fuel from equipment that could severely harm the environment. This symbol identifies an electrical danger. An electrical danger sign will appear in the text of this document when a potentially hazardous situation involving large amounts of electricity may arise if the instructions that follow are not adhered to closely. A potentially hazardous situation may involve the possibility of electrocution, severe bodily harm, or even death. Warning Warning Follow all applicable codes governing the installation and servicing of this product and the entire system. Always lock out and tag electrical circuit breakers while installing or servicing this equipment and any related equipment. A potentially lethal electrical shock hazard and the possibility of an explosion or fire from a spark can result if the electrical circuit breakers are accidentally turned on during installation or servicing. Follow all federal, state and local laws governing the installation of this product and its associated systems. When no other regulations apply, follow NFPA codes 30, 30A and 70 from the National Fire Protection Association. Failure to follow these codes could result in severe injury, death, serious property damage and/or environmental contamination. 3

Introduction The TS-EPS (Tank Sentinel - Ethernet Port Server) and TS-EPS-N (Tank Sentinel - Ethernet Port Server - Null) provide communication to an ATG (Automatic Tank Gauge) through a LAN (Local Area Network). The TS-EPS uses a 10 Base-T network configuration and communicates with the ATG using the RS-232 protocol, which allows the user to communicate to the ATG remotely, without the need for a phone line, using INCON s System Sentinel, System Sentinel AnyWare, or other software application. There are two versions of the TS-EPS: the TS-EPS and the TS-EPS-N. The TS-EPS is packaged with a DB-9M to DB-9F straight serial cable and configured to connect to any Franklin Fueling Systems ATG. The TS-EPS-N is packaged with a DB-9F to DB-25M null modem cable and is configured to connect to a Veeder Root TLS-350, TLS- 250 or other manufacturer s ATG. Scope The scope of this document is limited to the installation and connection of the TS-EPS or TS-EPS-N. Hardware Installation 1. Record the IP address that will be used for this device. The IP address will be useful when working with a multiple IP node site. Figure 1: TS-EPS Ethernet Connection Side Abbreviations and Acronyms ATG - Automatic Tank Gauge DHCP - Dynamic Host Configuration Protocol FFS Franklin Fueling Systems IP - Internet Protocol ISP - Internet Service Provider LAN - Local Area Network PC - Personal Computer SSA - System Sentinel AnyWare TS-EPS - Tank Sentinel - Ethernet Port Server TS-EPS-N - Tank Sentinel - Ethernet Port Server - Null Tools and Supplies Needed 10 Base-T network (Cat-5) cable with RJ-45 connectors to connect the EPS to a LAN Mounting hardware PC with a null modem adaptor/cable or connected to a LAN The network administrator will need to provide the following information for programming the EPS: IP Address Subnet Mask Gateway and Destination IP Figure 2: TS-EPS Serial Cable Connection Side 2. Assemble the TS-EPS unit in the following order (see Figure 2): a). Connect the serial interface cable (provided) from the male serial connection socket on the TS-EPS to: Comm 1 on a FFS ATG, the RS-232 card on a TLS-350, or the appropriate port on another manufacturer s ATG. Some models may need a DB-9 to DB-25 adaptor (also known as a gender changer ). b). Plug one end of a RJ-45, 10 Base-T Ethernet cable into the TS-EPS LAN Port and the other end into the server or server hub. c). Plug the power adapter into the back of the TS- EPS and the 115 VAC plug into an electrical outlet. There is no on / off power switch. As soon as the TS-EPS is connected to the power source, the device is active. 4

During the reboot process, the LEDs (STATUS, ETHERNET and SERIAL PORT 1) of the TS- EPS will transition from red to steady green. If the STATUS LED is not steady green after 1 minute, refer to the Troubleshooting section at the end of this document. d). Install the TS-EPS on a vertical or horizontal surface using the accompanying mounting bracket and four (4) appropriate fasteners (e.g. dry wall screws). Network Configurations There are many possible network configurations that the TS-EPS can integrate with. Below are two common setups: frame relay networks and cable/dsl connections. Frame Relay Networks EPS Hub Router (Frame Relay) Internet SSA Server Figure 3: TS-EPS Mountin Bracket 3. Once the connections are made, the unit will turn on and become ready for use. The TS-EPS will run onboard diagnostics and the LEDs will light. When the NDS is powered up, the LEDs will flash to indicate normal operation. The following LED colors and patterns will be displayed during normal startup, if no errors are detected. Status LED initially this LED will be yellow, but will quickly turn green. If the status LED is solid green, then the NDS does not have a permanent IP address and is trying to obtain one from a DHCP server. If the LED is blinking green, it means the NDS has obtained an IP address and is ready to use. Red indicates a fatal error. Ethernet LED this LED will either be off, green or blinking green/yellow. A green LED means that a good Ethernet link has been established and the unit is on the network. The LED will blink green/yellow to show network activity. Serial port LED this LED will normally be yellow or green. Yellow indicates a port that is not in use. Green indicates a port that is in use. The green LED will blink when data is transmitted or received. It will blink 2 times per second when data is continuously transmitted or received. A red LED indicates that an error condition was detected. Figure 4 - Frame Relay Network When setting up a TS- EPS on a frame relay network, the router will have a public IP address (provided by the site). The router needs to be programmed to route the traffic it receives on port 8001 to a private IP address. The TS-EPS is programmed with that private IP address and the route on the TS-EPS is programmed as: Gateway = the IP of the router and Destination = the IP of the firewall where SSA is. The site in System Sentinel AnyWare (SSA) and/or System Sentinel will be programmed with the public IP of the router and port 8001. Cable/DSL Connections EPS or DSL Router - or - Cable Router DSL or Cable Modem Figure 5 - Cable/DSL Connections Internet SSA Server When setting the TS-EPS up on a cable/dsl connection, the ISP (Internet Service Provider) will provide a cable/ DSL modem and a public, static IP. The TS-EPS will then be programmed with the provided public IP address and connected to the Internet via the modem. A router could also be added to this configuration for added security and to allow other devices to share the same public IP. If a router is installed, it will be programmed to have the public IP address and to route any traffic received on that public IP. The router will then send any data received on that public IP address for 8001 to a private IP address. The TS-EPS is programmed with the private IP address and the route for the TS-EPS will be: Gateway = private IP address and Destination = IP of the firewall where SSA resides. The Site in System Sentinel AnyWare (SSA) and / or System Sentinel will be programmed with the public IP of the router and port 8001. 5

Getting Started Connect the internet and then the power wire from the power adapter to the power connection socket. There is no turn on / off button. As soon as you connect TS-EPS to the power line, the device will be on. During the reboot process, the lights of the LEDs (STATUS, ETHERNET and SERIAL PORT 1) of the TS-EPS change to show green when connected. If the TS-EPS does not show the STATUS as green after 1 minute, contact FFS Technical support (800-984-6266). By using the IP address assigned from your service provider or using the one that TS-EPS obtained, launch a browser and enter this IP address as a URL. You should see a welcome screen that describes the unit. Setup Communication Parameters By using the Port Server Utilities, find the TS-EPS connected to internet: Figure 7: TS-EPS System Welcome Screen Click on Serial Settings on the side bar to bring up the following screen. Hover the mouse pointer in the window to bring up the IPv6 and IPv4 message box. Figure 6: Port Server Utility Screen: ipv4 and ipv6 Values Ask your internet provider to reserve an IP address to your TS-EPS. If no address is reserved for the TS-EPS, TS- EPS will obtain one that is available from the DHCP server. Figure 8: Serial Setting Screen Here, you can set the communication parameters for your serial communication to the tank gauge. 6

Network Interface Settings IP Routing Network Interface settings is where the IP Address and subnet mask (netmask) are entered. This information can be supplied by the Network Administrator or ISP (Internet Service Provider). IP Routing is where the gateway address or network routes are programmed. This is needed when connected through fire-walls or routers. There may be several routes that need to be programmed when connecting through a complex network. 7

SSA Settings From SSA, there is a page where you can program the TS-EPS for the site that has such device. The following figure shows the interface once a particular site has been selected: Figure 9: SSA Setup The Default Host Address is the IP address of the TS-EPS and Port will be always 8001. Default values can be set thru SSA Router as it shown below (Configuration and also be modified in the SSA web screen under System/Configure). Figure 10: Set up SSA Router 8

TS-EPS Diagnostics The TS-EPS has the capability to syslog events in the web interface provided by default from Systech. To access such sylog and other interactive parameters from the TS-EPS, enter the IP address of the TS-EPS in the URL of a browser and you will have access to syslog and other configuration parameters of the TS-EPS: Figure 11: TS-EPS Syslog Screen Green colored text means information, yellow means warning and red means dangerous messages respectively. 9

10 Page intentionally blank

Page intentionally blank 11

2012 INCON 000-1071 Rev. E 3760 Marsh Road Madison, WI 53718 U.S.A. Tel: +1 608 838 8786 Fax: +1 608 838 6433 www.franklinfueling.com Tel: USA & Canada 1 800 225 9787 Tel: Mexico 001 800 738 7610