Arthroscopic diagnosis and repair of Partial-Thickness Rotator Cuff Tears using the PASTA Depth Guide Surgical Technique

Similar documents
Shoulder Restoration System

Bankart Repair using the Smith & Nephew BIORAPTOR 2.9 Suture Anchor

the revo / mini-revo shoulder fixation system s u r g i c a l t e c h n i q u e

Stabilization of Acute Acromioclavicular Joint Dislocations using Dog Bone Button Technology Surgical Technique

Double Bone Plug Meniscus Reconstruction Surgical Technique

Arthroscopic Shoulder Procedures. David C. Neuschwander MD. Shoulder Instability. Allegheny Health Network Orthopedic Associates of Pittsburgh

Arthroscopic Shoulder Instability Repair Using the SUTUREFIX ULTRA Suture Anchor and SUTUREFIX ULTRA Instrumentation System

The Material Difference. Options for Rotator Cuff Repair, Labral Repair and Suture Management

Achilles Tendon Repair, Operative Technique

Rotator Cuff Tears in Football

Portal Placement for Shoulder Arthroscopy: Basic to Advanced William B. Stetson, MD

Combined lesions of the glenoid labrum include labral

The rapid evolution of arthroscopic shoulder surgery

Shoulder Arthroscopy

Ms. Ruth Delaney ROTATOR CUFF DISEASE Orthopaedic Surgeon, Shoulder Specialist

Mini TightRope CMC Surgical Technique

.org. Rotator Cuff Tears: Surgical Treatment Options. When Rotator Cuff Surgery is Recommended. Surgical Repair Options

Knotilus TM. Anchor Instability Repair. Technique Guide

Shoulder Impingement/Rotator Cuff Tendinitis

POSTOPERATIVE SHOULDER

Hip Arthroscopy Product Guide

FAST-FIX 360 Meniscal Repair System

Arthroscopic Subscapularis Repair

All Suture Anchor. with IntelliBraid Technology

SHOULDER INSTABILITY. E. Edward Khalfayan, MD

Fact. However. Historically 5/4/15. Arthroscopic Revision Cuff Repair. Revision Rotator Cuff Repair: How To Do It Better

Dr. Benjamin Hewitt. Subacramial Decompression & Rotator Cuff Repair

The Trans-Rotator Cuff Approach to SLAP Lesions: Technical Aspects for Repair and a Clinical Follow-up of 31 Patients at a Minimum of 2 Years

Form follows function. As physicians and scientists,

SHOULDER INSTABILITY IN PATIENTS WITH EDS

5/7/2009 SHOULDER) CONDITIONS OF THE SHOULDER NOW IT TIME TO TEST YOU ICD-9 SKILLS: PLEASE APPEND THE APPROPRIATE DIAGNOSIS CODE FOR EACH:

Reimbursements for. Getting Reimbursed for Shoulder Scopes. Even the most common procedures can challenge the most experienced coders.

Technique Guide. VersiTomic. Michael A. Rauh, MD. Anterior Cruciate Ligament Reconstruction

1 of 6 1/22/ :06 AM

Flying Swan Arthroscopic Labral Repair using a Tensioned Suture Bridge Construct

SHOULDER PAIN. Procedures: Subacromial, Glenohumeral and Acromioclavicular Injections Nonprocedural Treatments

TOWN CENTER ORTHOPAEDIC ASSOCIATES P.C. Labral Tears

Rotator Cuff Surgery: Post-Operative Protocol for Mini-Open or Arthroscopic Rotator Cuff Repair

Labral Repair. Surgical Protocol by Ronald Glousman, M.D. and Nicholas Sgaglione, M.D.

Anatomic Percutaneous Ankle Reconstruction of Lateral Ligaments (A Percutaneous Anti ROLL)

Arthroscopic Shoulder Stabilization With Suture Anchors: Technique, Technology, and Pitfalls

ARTHROSCOPIC (KEY-HOLE) SHOULDER SURGERY

J F de Beer, K van Rooyen, D Bhatia. Rotator Cuff Tears

28% have partial tear of the rotator cuff.

Laparoscopic Trainer Product Catalog

Integumentary System Individual Exercises

Labral Repair. Surgical Protocol by Ronald Glousman, M.D. and Nicholas Sgaglione, M.D.

PHaSES: Practical Hands-on Surgical Education System

J F de Beer, K van Rooyen, D Bhatia. The Biceps tendon

How To Fix A Radial Head Plate

Rotator Cuff Pathophysiology. treatment program that will effectively treat it. The tricky part about the shoulder is that it is a ball and

Shoulder Impingement Syndrome

.org. Shoulder Pain and Common Shoulder Problems. Anatomy. Cause

10/16/2012. Marc J Breslow, MD Illinois Bone and Joint Institute Morton Grove, Des Plaines

Notice of Independent Review Decision DESCRIPTION OF THE SERVICE OR SERVICES IN DISPUTE:

Dr. Benjamin Hewitt. Shoulder Stabilisation

Titanium Wire with Barb and Needle. For canthal tendon procedures.

Sports Medicine Instruments. shoulder small joint hip knee. Our Strengths Become. Your Solutions

Lateral Ankle Instability Repair using TWINFIX Ti 3.5 mm Suture Anchors

Minimally Invasive Hip Replacement through the Direct Lateral Approach

Laparoscopic Instruments

Beaver-Visitec International. Ophthalmic and Microsurgical Product Catalog

Crescent-shaped rotator cuff tears are relatively

Rehabilitation Guidelines for Shoulder Arthroscopy

The Treatment of Traumatic Recurrent Anterior Shoulder Instability with Arthroscopic Bankart Repair

AAOS Guideline on Optimizing the Management of Rotator Cuff Problems


A Technical Pearls Newsletter for Arthroscopists

Orthopaedic Surgery Sports Medicine How Does Arthroscopic Rotator Cuff Repair Surgery Work?

Classic shoulder impingement as described by. Anterior Internal Impingement: An Arthroscopic Observation. Original Article With Video Illustration

Rotator Cuff Tears. Anatomy

Shoulder Instability. Fig 1: Intact labrum and biceps tendon

Surgical Technique. coflex Surgical Technique

Rotator Cuff Repair Surgical Procedures

Arthroscopy of the Hand and Wrist

Scout Vessel Guard. A cover for vessels during anterior lumbar spine surgery.

ABSTRACT. Conrad Wang, MD is a Resident in the Harvard Combined Orthopaedic Residency Program

Rehabilitation Guidelines for Knee Arthroscopy

Rotator Cuff Repair Protocol

MODIFIER 59 ARTICLE. The CPT Manual defines modifier 59 as follows:

Surgical Technique. Struan H Coleman MD, PhD

The postoperative rehabilitation program is critical

THE SHOULDER. Shoulder Pain. Fractures. Instability and Dislocations of the Shoulder

Traumatic Primary Eyelid and Facial Laceration Repair. Riva Lee Asbell Philadelphia, PA

Outcome of Arthroscopic Repair of Type II SLAP Lesions in Worker_s Compensation Patients

Spinal Arthrodesis Group Exercises

Good morning, everyone! I m Sue Banta, a coding consultant for Amphion Medical. ambulatory knee and shoulder procedures.

A Simplified Approach to Common Shoulder Problems

Zimmer Small Fragment Universal Locking System. Surgical Technique

Arthroscopic Rotator Cuff Repair

Type II SLAP Repair of patients with Arthroscopic Prognosis

Smith & Nephew DYONICS RF Radiofrequency System

SALVATION. Fusion Bolts and Beams SURGICAL TECHNIQUE

V-TEK IVP System 2.7 System 4.0

.org. Rotator Cuff Tears. Anatomy. Description

Curriculum Vitae Curtis R. Noel, MD

A patient s s guide to: Arthroscopy of the Hip

ARTHROSCOPIC ROTATOR CUFF REPAIR DOCTORS HOSPITAL CENTER FOR ORTHOPEDICS AND SPORTS MEDICINE CORAL GABLES, FLORIDA June 18, 2008

Posttraumatic medial ankle instability

SHOULDER ACROMIOPLASTY/ SHOULDER DECOMPRESSION

Transcription:

Arthroscopic diagnosis and repair of Partial-Thickness Rotator Cuff Tears using the PASTA Depth Guide Surgical Technique Partial-Thickness Rotator Cuff Repair

Introduction The PASTA Depth Guide was developed by Ian K.Y. Lo, M.D., in an effort to provide a surgical tool to directly quantify and classify partial thickness rotator cuff tears arthroscopically. The simplistic view of repairing a partial articular surface tendon avulsion (PASTA) lesion with greater than 50% involvement of the tendon versus debriding those with less than 50% involvement is appealing but is sometimes difficult to determine at the time of diagnostic shoulder arthroscopy. Using the footprint as a marker to determine whether or not a tear involves greater or less than 50% of the tendon has been proposed. 1 The PASTA Depth Guide estimates the size of the tear and the overall depth of the footprint, determining the percentage of tendon torn. Utilizing this percentage within a classification system, surgeons can reliably determine the appropriate treatment decision for partial thickness rotator cuff tears. Reference: 1 Stetson W, Ryu R, Bittar E. Arthroscopic Treatment of Partial Rotator Cuff Tears. Oper. Tech. Sports Med. 12 (2004): 135-148. Instrument Technique Determining Percentage of Tear 3 2 1 0 markings* 1 2 Penetrate the rotator cuff tendon tear through a stab incision and position the guide tangential to the footprint. While viewing intraarticularly, place the tip of the inner rod at the articular margin. Confirm the size of the exposed footprint by counting the 3 mm incremental markings*. Change to a subacromial viewing position and slide the outer sleeve to the bursal side of the rotator cuff tissue. Exposed Footprint 3 mm x 3 markings = 9 mm 3 Measure the Total Tendon Thickness by reading the markings on the back of the guide. Calculate the Percentage of Tear: Exposed Footprint X 100 Total Tendon Thickness 9 mm X 100 = 64% of torn tendon 14 mm

Repair Techniques * Anchor Insertion Technique The subacromial bursa must be thoroughly excised to easily locate the passed sutures in the subacromial space once the anchors have been inserted. While viewing intraarticularly, use a spinal needle to determine the optimal position and angle of approach for transtendon suture anchor placement. 1 Prepare a bone socket for a suture anchor with a transtendon Bio-Corkscrew FT Punch. (This step can be bypassed if using a titanium Corkscrew FT II Suture Anchor.) 2 Place the Bio-Corkscrew FT or the Corkscrew FT II Suture Anchor through the skin puncture, through the rotator cuff tendon, and into the bone socket. Continue on to steps four and five of either the Single Anchor Repair or the Double Anchor Repair. 3 * Stephen S. Burkhart M.D., Ian K. Y. Lo M.D., and Paul C. Brady M.D., Burkhart's View of the Shoulder: A Cowboy's Guide to Advanced Shoulder Arthroscopy (Philadelphia: Lippincott Williams & Wilkins, 2006) 261.

Single Anchor Repair Double Anchor Repair 4 4a The Penetrator Suture Retriever is used to pass two suture limbs from the anchor through a separate puncture site in the rotator cuff. This allows a suture bridge (between the two sets of sutures) to be apposed to the bone bed when the sutures are tied. The Penetrator Suture Retriever is used to make three passes per anchor. For each anchor: Pass the two white/black TigerWire sutures separately Pass the two blue sutures through one pass Superior View 5 5a Tie the sutures subacromially. The best angle of approach for the knot pusher is through a superolateral portal adjacent to the acromonial process (acromion). The final result is confirmed with good tissue indentation by the sutures from the subacromial perspective and good restoration of the rotator cuff footprint on the intraarticular view. Tie each matching pair of white/black TigerWire sutures from each anchor together. Tie one blue suture limb from one anchor and another suture limb from the other anchor together. Tie the remaining blue sutures from each anchor together to finish off the bridge which compresses the tissue.

Ordering Information Implants/Disposables: Bio-Corkscrew FT, 5.5 mm x 15 mm, w/two #2 FiberWire Corkscrew FT II, 5.5 mm x 16 mm, w/two #2 FiberWire PEEK Corkscrew FT, 5.5 mm x 16 mm, w/two #2 FiberWire Crystal Cannula, 5.75 mm I.D. x 7 cm AR-1927BF AR-1928SF-2 AR-1928PSF-2 AR-6560 Accessory Instruments: PASTA Depth Guide Bio-Corkscrew FT Punch, reusable Bio-Corkscrew FT Punch, disposable PEEK Corkscrew FT Punch/Tap Penetrator Suture Retriever, straight KingFisher Suture Retriever/Tissue Grasper KingFisher Suture Retriever/Tissue Grasper w/wishbone Handle AR-2300 AR-1927PB AR-1927PBS AR-1928PT AR-2167ST AR-13970SR AR-13970W

Arthrex, Inc. 1370 Creekside Boulevard, Naples, Florida 34108-1945 USA Tel: 239-643-5553 Fax: 239-598-5534 Website: www.arthrex.com Arthrex GmbH Liebigstrasse 13, D-85757 Karlsfeld/München Germany Tel: +49-8131-59570 Fax: +49-8131-5957-565 Arthrex Latin América 3750 NW 87th Avenue, Suite 620, Miami, Florida 33178 USA Tel: 954-447-6815 Fax: 954-447-6814 Arthrex S.A.S. 5 Avenue Pierre et Marie Curie, 59260 Lezennes France Tel: +33-3-20-05-72-72 Fax: +33-3-20-05-72-70 Arthrex Canada Lasswell Medical Co., Ltd., 405 Industrial Drive, Unit 21, Milton, Ontario Canada L9T 5B1 Tel: 905-876-4604 Fax: 905-876-1004 Toll-Free: 1-800-224-0302 Arthrex GesmbH Triesterstrasse 10/1 2351 Wiener Neudorf Austria Tel: +43-2236-89-33-50-0 Fax: +43-2236-89-33-50-10 Arthrex BvbA Technologiepark Satenrozen, Satenrozen 1a, 2550 Kontich Belgium Tel: +32-3-2169199 Fax: +32-3-2162059 Arthrex Ltd. Unit 16, President Buildings, Savile Street East, Sheffield S4 7UQ England Tel: +44-114-2767788 Fax: +44-114-2767744 Arthrex Hellas - Medical Instruments SA 43, Argous Str. - N. Kifissia, 145 64 Athens Greece Tel: +30-210-8079980 Fax: +30-210-8000379 Arthrex Sverige AB Turbinvägen 9, 131 60 Nacka Sweden Tel: +46-8-556 744 40 Fax: +46-8-556 744 41 Arthrex Korea Rosedale Building #1904, 724 Sooseo-dong, Gangnam-gu, Seoul 135-744 Korea Tel: +82-2-3413-3033 Fax: +82-2-3413-3035 Arthrex Mexico, S.A. de C.V. Insurgentes Sur 600 Mezanine, Col. Del Valle Mexico D.F. Mexico Tel: +52-55-91722820 Fax: +52-55-56-87-64-72 This description of technique is provided as an educational tool and clinical aid to assist properly licensed medical professionals in the usage of specific Arthrex products. As part of this professional usage, the medical professional must use their professional judgment in making any final determinations in product usage and technique. In doing so, the medical professional should rely on their own training and experience and should conduct a thorough review of pertinent medical literature and the product s Directions For Use. U.S. PATENT NOS. 5,964,783; 6,074,403; 6,517,552; 6,716,234; 7,029,490 and PATENT PENDING Copyright Arthrex Inc., 2006. All rights reserved. LT0222A