AP21 Series Time Switch

Similar documents
ODOT ITB Section 4: Flashers, Timers, & Software Systems Item 4-1

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

Neonixie 6 Digit Nixie Clock Controller Introduction and Assembly

SSW-iLM Keypad. Wire Harness Configuration. Note: This product is designed to be installed and serviced by security and lock industry professionals

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

INSTALLATION INSTRUCTIONS

AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER

SMC 3000 Series Master Clock Programming Manual (V3) Table of Contents. Getting Started.. Page 2. Setting the Time of Day...

INSTALLATION AND OPERATING INSTRUCTIONS

User Manual. Humidity-Temperature Chart Recorder. Model RH520

CONTROL SWITCHER User s Manual (Preliminary)

Advantium 2 Plus Alarm

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

Model Owner s Manual. Español - P. 19 Français - P. 39

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

Telephone Controller INSTRUCTION MANUAL MODEL CT240-01

Installation and Operation Guide PD4600 Series Converter Replacement

LIGHTING CONTROL PANEL

OUTPUT CABLE CONNECTIONS:

THERMONET UNDERFLOOR HEATING STANDARD THERMOSTAT KIT STOCK CODE 5260

TC-9102 Series Surface Mount Temperature Controllers

12 Volt 30 Amp Digital Solar Charge Controller

STAGE SETTER-8. User Instructions. Elation Professional

INSTALLER S & OWNER S MANUAL

INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.

SETTING UP YOUR 6000 SERIES TIME RECORDER

Installation and Operation Guide for PD4000 Series Power Control Center

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Installation and Operation Guide for PD4100 Series Power Control Centers

VK-250 WARRANTY REGISTRATION FORM

PERF10 Rubidium Atomic Clock

Wireless Thermostats 230v and Battery Operated Instruction Manual

LCD5500Z / PKP-LCD v3.x Installation Instructions

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

Single Station Remote Alarm

Installation and Operation Back-UPS 1250, 1300, 1500

SECTION LOW VOLTAGE LIGHTING CONTROLS

OWNER'S MANUAL. Model CUL AC Power Inverter/Charger System OM/A96283 REV. A

Time Recorder. User Manual. PDF created with FinePrint pdffactory trial version

EK908FHL - Thermostat for floor heating

Solid State Timers Type F

USER MANUAL. Model U ForeFront Alarm Card SALES OFFICE (301) TECHNICAL SUPPORT (301) An ISO-9001 Certified Company

Operating Instructions

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

Auto Dialer. Manual E-921APQ E-921GPQ

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

TTL to RS232 Adapter User Guide

NSI DIGITAL DIMMING SYSTEM DDS 9800 DIMMER PACKS

OPERATING INSTRUCTIONS Model ST-888 DTMF ANI/ENI Display Decoder

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Owner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10. Programmable thermostat Thermostat programmable Termostato programable

EL71 - Single Channel & EL72 - Two Channel Electronic Time Controls General Instructions

User's Guide Integrating Sound Level Datalogger Model

AEROMOTIVE Part # INSTALLATION INSTRUCTIONS

HM-W536 Install Guide

Chapter 2 System Basics

ETHERNET IRRIGATION CONTROLLER. Irrigation Caddy Model: ICEthS1. User Manual and Installation Instructions

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

AUTOMATIC BEST BATTERY SELECTOR INSTALLATION & OPERATION BBS-1600 BBS-1600E

OWNER S MANUAL 2.5/3.0 ACS PANEL (ADVANCED CONTROL SYSTEM) 7725 Lougheed Highway Burnaby, BC V5A 4V8 Canada

Application Technique. Safety Function: Magnetic Door Switch Monitoring

Model 5511 Filler Controller User s Manual Version 1.1 October 2011

USB/VGA Cat 5 UTP Console Extender

User's Manual. Model Laser Photo / Contact Tachometer. Introduction

Owner s Manual. Walk-in Monitoring System 100. Cooler is Better! TM. Used in UL Listed Door Panel Assemblies

Seven function digital multimeter

Transmitter Interface Program

Trilogy Series DL3000 Programming Instructions

AutoRanging Digital MultiMeter

Operation and Installation Manual

INSTALLATION/PROGRAMMING INSTRUCTIONS 928 ENTRYCHECK

Water Leak Detection System

Model SPDT Relays

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

WARRANTY AND DISCLAIMER

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

DAB+ / FM Tuner Model: TU-201

Time switch D21-1-channel / 32 / / 63 / General information. Overview. Set language

Applied Electronics. Commercial Dimming System UPDATE NOTICE

PROGRAMMING & OPERATING INSTRUCTIONS CL5000 AUDIT TRAIL

V-2901 UNIVERSAL DOOR ANSWERING SYSTEM

Installation, Operation & Service Manual

IO-RM3 3-Stage Relay Module

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

INSTALLATION. Omega 8000 Series Controller For Use With Omega 90 Siren/P.A. Amplifier

Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification

O C M III. Open Channel Flow Monitor

Model: v2 Quick Setup Guide DC: Atomic Projection Alarm with Indoor and Outdoor Temperature

Brushless DC Motor Controller Product Specification Assembly 025F0129

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Intelligent GSM Auto-Dial Alarm System

PK5500 v1.1 Installation Instructions

User Manual. English. APC Smart-UPS SC. 1000/1500 VA 110/120/230 Vac. 2U Tower/Rack-Mount Uninterruptible Power Supply

WD-AMX Water Detection Controllers

Electronic Time Recorder

INSTALLATION & SERVICE MANUAL. Display Panel

Transcription:

AP21 Series Time Switch Operation/Service Manual (use this manual for Ver 3.02 and higher) Helping Kids Get To School Since 1987 RTC Manufacturing, Inc. 1016 Enterprise Place * Arlington, TX 76001 www.rtc-traffic.com (817) 860-1217

AP21 SERIES TIME SWITCH OPERATION/SERVICE MANUAL Table of Contents 2 A. Introduction 3 B. Specifications Programming Capabilities 3 Electrical 3 Power Fail Backup 4 Accuracy 4 Physical 4 C. Wiring 4 D. Description of Display and Keyboard Alpha-Numeric Display 5 Keyboard 5 E. Programming Instructions AP21 Cursor 6 Auto Prompt Display 6 Entering Data 6 Quick Reference Program Guide 7 Program Guide Key 8 Special Code 8 Time Switch Keys 8 Programming Procedures for: TIME 8 DATE 9 DAY 9 DST 9 BASIC Program Steps 10 ANNUAL Program Steps 10 SLEEP MODE 11 PULSE 11 MANUAL Operation 12 SECONDS Display 12 PROGRAM TRANSFER 12 F. Warranty 12 G. Service 12 H. Theory of Operation 13 I. Schematic & Part List 13 2

AP21 SERIES OPERATOR S MANUAL OPERATIONS/SERVICE MANUAL A. INTRODUCTION The AP21 is an single circuit, calendar programmable solid state time switch. It is used for switching electric circuits according to pre-set time and date program. The AP21 AUTO PROMPTING alpha-numeric display makes programming fast and simple. It is designed to control zone flashers, time-of-day flash, or any other traffic application where holiday skip is desired. The output relay is rated at 120 VAC, 15 amps resistive load. The output can be programmed for momentary operation such as required for ringing bells in school, churches or industrial facilities. The relay output can also be disabled by SLEEP MODE function to allow time switch to maintain data without operating the relay. B. SPECIFICATION PROGRAMMING CAPABILITIES 1. Auto Prompting Display - Provides display information to guide the operator during programming. From a cold start it will prompt the operator in setting the time through setting the basic program steps. 2. 16 Program Steps - Each step can be programmed for a specific day of the week, for Monday through Friday only, for Saturday and Sunday only, or for every day of the week. 3. 10 Skip Plans - Each skip plan has a starting and ending date that prevents the output relay from activating. This feature can be used to skip a specific day or a group of consecutive days. 4. Programmable Daylight Saving Time Adjustment - The AP21 can be programmed to automatically adjust its time for daylight savings time changes according to U.S. law, even if the law changes. 5. Automatic Leap Year Compensation. 6. Manual Override - The output relay can be manually energized or de-energized from the keyboard. The manual override remains in effect until the next programmed step occurs. 7. Sleep Mode - Deactivates relay output while maintaining all timing data during summer vacation. 8. Pulse Output - The output can be programmed to operate as constant contact or a momentary contact programmable from 1 to 99 seconds. 9. Program Transfer - This option allows the operator to program an AP21 and download that program to another AP21 with the use of a simple unit-to-unit transfer cable. ELECTRICAL Power Requirements - Outputs - Wiring - 95VAC to 135VAC, 60HZ., 3 VA maximum. 10.5VDC to 14.3VDC less than 1 Watt through full range of supply volt age (0.2 to 0.58 average) AP21, SPDT relay rated at 15 AMP resistive at 120VAC. Terminal block can accommodate #10 to #24 AWG wire. 3

POWER FAIL BACKUP Program and time keeping is maintained for 48 hours on a rechargeable capacitive backup system in the event of a power failure. The output and display are disabled during backup. The AP21 resumes normal operation when power is restored. ACCURACY Time Keeping - Synchronous with the AC power line and 4 PPM on DC power. During a power failure it is quartz crystal controlled with an accuracy of +/-.005% throughout its full temperature range. Programmed Events - On/Off events are programmable with a one minute resolution and occur at the zero second of that minute. PHYSICAL 3.7"W x 8.0"H x 1.55"D Weight - Approximately 2 lbs. Mounting - Mounting hole provided (AP21/AP21T). Operating Temperature Range - -30 to +74 C. C. WIRING Remove power before wiring connection. Observe all safety precautions. AP21 Terminal Block AC- AC+ GND +12V -12V N/O N/C COM Relay moveable (in) AP21 Harness Connection (16 Pin Connector) White Neutral (AC-) Pin 2 Black/White Line (AC+) Pin 1 Green Safety Ground Pin 3 Relay N/O (out) Red +12VDC Pin 15 Black/Red - 12VDC Pin 13 Yellow/White N/O (Relay) Pin 10 Yellow N/C (Relay) Pin 5 Yellow/Black Com (Relay) Moveable Contact Pin 4 AP21TR OCTAL BASE MOUNT PIN OUT (Discontinued product) To install the AP21TR requires an eight pin octal base Potter and Brumfield #27E122 or equal. Mount this base in a suitable location and wire the terminals of the base as follows: AC Version DC Version 1. Relay Common 1. Relay Common 2. Line 2. 3. Relay normally open 3. Relay normally open 4. Relay normally closed 4. Relay normally Closed 5. 5. 6. 6. -12VDC 7. Neutral 7. 8. 8. +12VDC 4

D. DESCRIPTION OF DISPLAY AND KEYBOARD 1. ALPHA-NUMERIC DISPLAY Used for displaying time, day, date, output status and for displaying information during programming or reviewing stored programs. 2. KEYBOARD Many of the AP21 keys serve multiple functions. Those keys are clearly labeled with their functions printed adjacent to the key. They cannot be used incorrectly as the display will AUTO PROMPT the user as to which key to press. AM/ON (#1) KEY Used for setting time to AM when in the time set or programming modes. Also used for setting output to ON or OFF when in the programming mode. Also used for setting the output to ON manually. PM (#2) KEY Used for setting the time to PM when in the time set or programming modes. TIME (#3) KEY Used for entering the set time mode. ANNUAL (A) KEY Used for entering the annual programming mode and for stepping through the stored annual programs for review. The annual programs contain the skip plans in calendar schedule form. BASIC (B) KEY Used for entering the basic programming mode and for stepping through the stored basic programs for review. The basic programs contain the daily timed events instructions. CLEAR (C) KEY Used for clearing all annual skip plans and basic program steps. DATE (D) KEY Used for entering the set date mode for entering date or reviewing the date. EXIT (#) KEY Used for exiting the set time, set date, or program mode. OFF (#0) KEY Used for setting the output to OFF when in the programming mode. Also used for setting the output to OFF manually. STEP/ENTER (*) KEY Used for entering all commands and for stepping through the set time, set date or program data entry. DST (#7) KEY Used for entering or changing the daylight savings time program. DAY (#4) KEY Used for setting the current day of the week. (#5) KEY (PULSE) Used for programming the output relay/s for steady or pulse operation. 5

E. PROGRAMMING INSTRUCTIONS THE AP21 CURSOR - On many of the AP21 display screens you will see a flashing square character called the cursor. The cursor indicates that you may now enter or change the data at that position of the display. AUTO PROMPT DISPLAY - On a cold start with a discharged back-up capacitor, the AP21 will automatically prompt the operator through the programming procedure. The operator simply has to follow the display and enter the appropriate data as the cursor advances through the program entries. You may exit this sequence if desired by pressing the EXIT (#) key and the unit will default to the time display mode. From the time display mode, you may enter any of the set time, date, or program modes manually. ENTERING DATA - From the cursor, you enter the appropriate data and press the ENTER (*) key. The cursor will automatically advance to the next position. If the data at the cursor is correct, simply press the ENTER (*) key to advance the cursor. The AP21 will not allow you to enter an invalid number (i.e., the unit will not accept the number 13 for a month entry). The cursor will remain in its position until a valid entry is made, so keep pressing the keys until you see the correct number at the cursor and then press the ENTER (*) key. 6

AP21 QUICK REFERENCE PROGRAM GUIDE NOTE: The display of the AP21 will automatically blank after about 5 minutes of keyboard inactivity, simply press any key to reactivate the display. Start from the time display mode: TIME:Press the TIME (3) key, press ENTER (*), and enter the time as follows: HH * MM * AM/PM * (enter) (enter) (enter) DATE: Press the DATE (D) key, press ENTER (*), and enter the date as follows: MM * DD * YY * DAY: Press the DAY (4) key, press ENTER (*), and enter the day of the week as follows: Day-of-week * (press the DAY (4) key to advance the day) DST: Press the DST (7) key, press ENTER (*), and enter the spring and fall Daylight Savings Time as follows: S DST: MM * SUN * F DST: MM * SUN * Current U.S. law: Spring = Month 3, Sunday 2 Fall = Month 11, Sunday 1 BASIC: Press the BASIC (B) key, press ENTER (*), key in the step number, press ENTER (*), and enter the program step information as follows: Day/s * HH * MM * AM/PM * ON/OFF * ANNUAL: Press the ANNUAL (A) key, press ENTER (*), key in the skip number, press ENTER (*), and enter the annual skip plan program as follows: START: MM * DD * YY * END: MM * DD * YY * Note: Single Day skip- Start & End date are the same. MANUAL: To manually operate the output relay: To turn on: 1 * To turn off: 0 * 7

SECONDS: Key in 33 and press the ENTER (*) key. Press the EXIT (#) key to go back to normal time display. TRANSFER: Key in 78 on the AP21 you wish to transfer from, press ENTER (*). Connect the transfer cable (RTC Part # 91107), press ENTER (*). CLEAR: Press the clear (C) key, press ENTER (*). Press ANNUAL (A) key to clear all of the Annual programs. Press BASIC (B) clear all of the Basic programs. Key: * = enter WDY = Mon thru Fri EDY = every day of the week WND = Sat & Sun only MM = month of the year DD = day of the month YY = year HH = hour of the day MM = minute of the hour SUN = the Sunday of the month for DST change 1 = first Sunday 2 = second Sunday 3 = third Sunday 4 = fourth Sunday L = last Sunday Special Codes: Time Switch Keys: 0 = Manual operation - OFF 1 = Manual operation - ON 7 = DST (daylight saving time change) 45= Sleep Mode (Disables output relay) 77 = Clear all data for reprogramming 78 = Program transfer between AP21 units 99 = Software version 88 = Prevents the screen from blanking 88 again allows the screen to blank (HH : MM) - Colon flashing= Display Blanking, Colon steady= Display ON continuous 1 = AM and ON 2 = PM 3 = TIME (time-of-day) 4 = DAY (day-of-week) 5 = PULSE (pulse or steady output/s) 7 = DST (Daylight Savings Time) 0 = OFF (relay off) A = ANNUAL (programs) B = BASIC (programs) C = CLEAR (clear all annual or basic programs) D = DATE (month, day, year) # = EXIT (exit to the time display mode) * = ENTER (enter the data at the cursor) Procedure for reviewing or changing the TIME: 8 Press the TIME (#3) key

if the hour displayed is correct or, key in the correct hour then press the ENTER (*) key, the cursor will advance to the minute position if the minute displayed is correct or, key in the correct minute then press the ENTER (*) key, the cursor will advance to the AM/PM position if the AM/PM displayed is correct or, key in the correct AM/PM then press the ENTER (*) key, the new time will begin and the display will return to the time display mode Procedure for reviewing or changing the DATE: Press the DATE (D) key if the month displayed is correct or, key in the correct month then press the ENTER (*) key, the cursor will advance to the day position if the day displayed is correct or, key in the correct day then press the ENTER (*) key, the cursor will advance to the year position if the year displayed is correct or, key in the correct year then press the ENTER (*) key, the display will return to the time display mode Procedure for reviewing or changing the DAY: Press the DAY (#4) key if the day displayed is correct or, advance to the correct day by pressing the DAY (#4) key, Press the ENTER (*) key, the display will return to the time display mode Procedure for reviewing or changing the DST (Daylight Saving Time): Press the DST (#7) key, the SPRING DST display will show if the month displayed is correct or, key in the correct month then press the ENTER (*) key, (NOTE: key in 00 (zero,zero) to defeat the DST feature) the cursor will advance to the Sunday position if the Sunday displayed is correct or, key in the correct Sunday then press the ENTER (*) key, the display will advance to the FALL DST display if the month displayed is correct or, key in the correct month then press the ENTER (*) key, the cursor will advance to the Sunday position of the Sunday displayed is correct or, key in the correct Sunday then press ENTER (*) key, the display will return to the time display mode 9

Procedure for entering or changing the BASIC program steps: Press the BASIC (B) key Key in specific program step number to be changed, then press the ENTER (*) key if the day/s displayed is correct or, advance to the correct day/s by pressing the DAY (#4) key, then press the ENTER (*) key, the cursor will advance to the hour position if the hour displayed is correct or, key in the correct hour then press the ENTER (*) key, the cursor will advance to the AM/PM position if the AM/PM displayed is correct or, key in the correct AM/PM then press the ENTER (*) key, the display will advance to the ON/OFF position if the ON/OFF displayed is correct or, toggle the ON or OFF then press the ENTER (*) key, the cursor will advance to the next program step number Repeat the programming process or press the EXIT (#) key to return to the time display mode Procedure for reviewing the BASIC program steps: Press the BASIC (B) key Press the BASIC (B) key to advance through the basic program steps Press the EXIT (#) key to escape to the time display mode Procedure for clearing a specific BASIC program step: Press the BASIC (B) key Key in the step number to be cleared then press the ENTER (*) key to advance the cursor to the hour Key in 00 (zero, zero) for the hour then press the ENTER (*) key, the program step is cleared and the display returns to step 00. Key in another step number to be cleared or press EXIT (#) to return to the time display mode Procedure for entering or changing the ANNUAL skip plan program steps: Press the ANNUAL (A) key Key in specific skip plan number to be changed, then press ENTER (*) key, the START date (MM-DD-YY) will be displayed if the month displayed is correct or, key in the correct month then press the ENTER (*) key, the cursor will advance to the day position if the day displayed is correct or, key 10

in the correct day then press the ENTER (*) key, the cursor will advance to the year position if the year displayed is correct or, key in the correct year then press the ENTER (*) key, the display will advance to the END date (MM-DD-YY) if the month displayed is correct or, key in the correct month then press the ENTER (*)key, the cursor will advance to the day position if the day displayed is correct or, key in the correct day then press the ENTER (*) key, the cursor will advance to the year position if the year displayed is correct or, key in the correct year then press the ENTER (*) key, the display will advance to the next skip plan number Repeat the programming process or press the EXIT (#) key to return to the time display mode Procedure for reviewing the ANNUAL skip plan program steps: Press the ANNUAL (A) key Press the ANNUAL (A) key to advance thru the annual skip plan program steps Press the EXIT (#) key to escape to the time display mode Procedure for clearing all of the ANNUAL programs: Press the CLEAR (C) key Press the ANNUAL (A) key to clear all annual programs The display returns to the time display mode Procedure for clearing a specific ANNUAL program: Press the ANNUAL (A) key Key in the skip number to be cleared then press the ENTER (*) key Key in 00 (zero, zero) for the month then press the ENTER (*) key, the skip plan is cleared and the display returns to skip 00. Key in another skip number to be cleared or, press the EXIT (#) key to return to the time display mode Procedure for activating SLEEP MODE:. Start from the time display mode. Key in 45 and press ENTER (*), SLEEP MODE will be displayed Procedure for deactivating SLEEP MODE:. Start from the SLEEP MODE display. Key in 45 and press ENTER (*) key to remove sleep mode Procedure for reviewing or changing the PULSE: 11 Press the #5 key if the pulse displayed is correct or,

key in the correct pulse then press the ENTER (*) key, (0 = steady, 1 to 9 seconds = pulse) the display will return to the time display mode Procedure for MANUAL operation of the output relay: ON Press the #1 key, the output relay is turned on The display returns to the time display mode OFF Press the #0 key, the output relay is turned off The display returns to the time display mode Procedure for displaying SECONDS in the time display: Key in 33 and press ENTER (*), the seconds display will be shown Press the EXIT (#) key to return to the normal time display mode Procedure for program transfer operation: F. WARRANTY Key in 78 on the AP21 you wish to transfer from, press ENTER (*) Connect a transfer cable to both AP21 units Press ENTER (*) on the AP21 you wish to transfer the program from The display on both units returns to the time display mode RTC Manufacturing, Inc. hereby warrants that, provided the time switch was properly installed, operated and maintained by the user, RTC will at its option, either replace or repair without charges any time switch found to be defective in materials and/or workmanship for two (2) years from the date of shipment. Products returned for warranty must be shipped freight prepaid. RTC will pay the shipping charges for repaired products returned to the customer via regular surface freight. Overnight delivery must be requested in advance and will be billed to the customer. In no event shall RTC Manufacturing, Inc. be liable for any injury, loss or damage, whether direct, consequential or incidental to persons or property arising out of purchaser s ability or inability to use the time switch. G. SERVICE It is recommended that all service for the AP21 be performed by the factory or by a factory authorized service representative. If you repair your AP21 time switches without factory support, please note the following: CAUTION: Before removing or replacing any IC1 or IC2, the 1 FD super capacitor must be totally discharged to avoid damage. On the left side of the printed circuit assembly, there are two test points. One is ground and the other is the super capacitor connection. Use a clip lead to short these test points together to discharge the super capacitor. It is recommended that the clip lead be left in place until the repair is completed. 12

RTC Manufacturing, Inc. is committed to provide ongoing service support for time switches in or out of warranty. Please ship your repairs freight prepaid to the dealer in your area: OR RTC Manufacturing, Inc. 1016 Enterprise Place Arlington, TX 76001 If the customer/end user ships directly to RTC, shipping charges will be paid by RTC for repaired products returned to the customer/end user via regular surface freight. Overnight delivery must be requested in advance and will be billed to the customer/end user. H. THEORY OF OPERATION The AP21 is a microprocessor based device. Because of the large scale integrated circuits used, there are only three (3) IC s that make up the time switch. IC1 is a 6805 type microprocessor with built-in RAM and ROM. The built-in RAM is used for storing the time, date and program information. The built-in ROM contains the AP21 operating software (approximately 4 k-bytes). The software of the AP21 time switch is copyrighted. Reproductions of any kind are strictly prohibited by law. IC2 is the real time clock. This circuitry is used only during power failures to keep time until power returns. I. Schematics and Parts List are available directly from RTC. Helping Kids Get To School Since 1987 RTC Manufacturing, Inc. 1016 Enterprise Place * Arlington, TX 76001 www.rtc-traffic.com (817) 860-1217 13