TELECOMMUNICATIONS AUTHORITY HONG KONG



Similar documents
TECHNICAL SPECIFICATION FOR PRIVATE AUTOMATIC BRANCH EXCHANGE (PABX) SYSTEM FOR CONNECTION TO PUBLIC SWITCHED TELEPHONE NETWORK (PSTN)

Customer Interface Publication: KCH CIP002. Public Switched Telephone Network (PSTN)

Suppliers' Information Note. BT Public Switched Telephone Network (PSTN): Technical Characteristics Of The Multi-Line Analogue Line Interface

If you want to get an official version of this User Network Interface Specification, please order it by sending your request to:

Configuring the 930A for Common PBX Metallic Signaling Interfaces

Customer Interface Publication: KCH CIP015. Technical Characteristics of the Privateline analogue leased line interfaces

Installation Manual for D0700 ISDN Analogue Converter

2-Wire/4-Wire Telephone Line Interface. XE0204 Block Diagram

TECHNICAL SPECIFICATION FOR CORDLESS TELEPHONE SYSTEMS

Overview of the Telecommunications Network

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

STI 9 Edition 2/October 2000

Guidelines for Application for Accreditation by the Communications Authority as Local Certification Bodies

NOKIA 32 SUPPORT GUIDE FOR INSTALLING NOKIA 32

BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1

TECHNICAL INFORMATION FOR FREQUENCY PLANNING IN-BUILDING COAXIAL CABLE DISTRIBUTION SYSTEM (IBCCDS)

Standardisation Guide HKTA 3209 for Calling Line Identity of Mobile Network In-bound Roamers

Miniature Surface-Mount DAA for Audio or Data Transfer XE0402LCC BLOCK DIAGRAM

IP Office - Job Aid Attaching 3rd Party Paging Equipment

Final draft ETSI ES V1.2.1 ( )

Ethernet Patch Cord Wiring

Chapter 8: The Telephone System

ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX

LOXONE 12 Channel Amplifier

200 Range Dialer Installation Manual. Version 1.0

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

IP DSLAM IDL Quick Installation Guide

Installation Manual for D1110 DigiCom2

LocoNet, the Digitrax Difference

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

FOR CALLING LINE IDENTIFICATION (CLI)

VOICE RECORDING SYSTEM ISDN PRI / BRI

ETSI TR V1.2.1 ( )

CX Zoner Installation & User Guide

)454 6 ")43 0%2 3%#/.$ $50,%8 -/$%- 34!.$!2$):%$ &/2 53% ). 4(% '%.%2!, 37)4#(%$ 4%,%0(/.%.%47/2+ $!4! #/--5.)#!4)/. /6%2 4(% 4%,%0(/.%.

1 All safety instructions, warnings and operating instructions must be read first.

GLOLAB Universal Telephone Hold

TELIKOU Intercom System. MS-500(4+1 channel) Main Station Instruction Manual

PagePac PAGEPAL V

How To Use A 1232 On A 1236 On A Computer Or A Cell Phone

Primary Voice Services over BreezeMAX Carrier class telephony and broadband data for new and incumbent networks

XN120 Getting Started Guide Rev 1.2 (March 2005)

TELEPHONE LINE ANALYZER KIT

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

Category 6 Solutions. 4. Category 6 Solutions. 09/ IN TrueNet Structured Cabling. Introduction Cable Patch Panels... 4.

5006 Centrex AuxBox. Call Recording for Meridian Digital Centrex Telephones. Hardware & Installation Guide

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

TELECOMMUNICATIONS STANDARDS ADVISORY COMMITTEE WORKING GROUP ON COMMON CONNECTION STANDARDS (CCS)

INTERFACING WITH THE TELEPHONE NETWORK USING THE MPC-2

)454 6 "!5$ -/$%- 34!.$!2$):%$ &/2 53% ). 4(% '%.%2!, 37)4#(%$ 4%,%0(/.%.%47/2+ $!4! #/--5.)#!4)/. /6%2 4(% 4%,%0(/.%.%47/2+ )454 Recommendation 6

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual

TECHNICAL TBR 21 BASIS for January 1998 REGULATION

AN-3 SEVEN KEY CONSIDERATIONS BEFORE YOU START YOUR SLIC OR FXS PHONE LINE INTERFACE DESIGN

NXU RoIP Link to Eliminate Voice-Grade Leased Line

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

TELECOMMUNICATIONS STANDARDS ADVISORY COMMITTEE TSAC WORKING GROUP ON NEW STANDARDS AND POLICY (NSP)

Telecommunications Switching Systems (TC-485) PRACTICAL WORKBOOK FOR ACADEMIC SESSION 2011 TELECOMMUNICATIONS SWITCHING SYSTEMS (TC-485) FOR BE (TC)

Networking 101 (Networking Basics) Presentation to UCHUG - 1/03/07 G. Skalka

Unattended Answering Device Instruction Manual

TECHNICAL TBR 12 BASIS for December 1993 REGULATION

TCB-2 Auto Answer Coupler Product Manual

Product Overview. Features CHAPTER

EVOline Multimedia Modules

Getting Started. Table of Contents. Hybrid IP-PBX

How To Use A Pump Station 16-R

DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations)

innkeeper PBX Desktop Digital Hybrid User Guide JK Audio Warranty

TELEPHONE CABLING TECHNOLOGY INFINITY CABLING

INTRODUCTION KRONE HIGHBAND. KRONE has a long history as a market leader in the communications and information industry.

UIM-2T1 T1 Loop Bonding Uplink Interface Module

innkeeper PBX Desktop Digital Hybrid User Guide JK Audio

innkeeper PBX Desktop Digital Hybrid User Guide JK Audio Warranty

The Telephone Network

428 MY HOME Structured cabling system for the home sector

8086 Telephony Training Systems

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

VCL-PRI ISDN VALIANT COMMUNICATIONS LIMITED. Primary Rate (Euro-ISDN) Multiplexer. Product Brochure & Data Sheet

FURTHER READING: As a preview for further reading, the following reference has been provided from the pages of the book below:

Casestudy of conformity of telecommunications terminal equipment in Japan

AXIS T81B22 DC 30W Midspan

Tele Eye DT Series. Installation Guide. Dialup CCTV Transmitter DT-103G DT-103P DT-103D

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects

TECHNICAL SPECIFICATION TSPE 2084 U 0 INTERFACE FOR ISDN BASIC ACCESS

PATTON TECH NOTES What are FXS and FXO?

Innkeeper PBX. Desktop Digital Hybrid. User Guide. JK Audio

SMZ type 43 INTRODUCTION. The Radiall Type 43 coaxial connector range. Type 43 series - Features and benefits

CISCO SPA3102 PHONE ADAPTER WITH ROUTER

3. Connecting to ISDN Delivery Options. 6. Customer Interface. 9. Connection of CPE. 10. Supplementary Services. 14. ISDN Applications.

Administrative Council for Terminal Attachments (ACTA) Customer Information

TNE1500-P and TNE1500-S Single Line T1 Network Extender Provider and Subscriber

APPLICATION NOTE # Using Sage SMOS for VoIP Testing, IP Phone to IP Phone TABLE OF CONTENTS

Transcription:

HKTA 2023 ISSUE 04 NETWORK CONNECTION SPECIFICATION FOR CONNECTION OF CUSTOMER PREMISES EQUIPMENT (CPE) TO THE LEASED LINE OR PRIVATE CIRCUIT PROVIDED BY THE FIXED TELECOMMUNICATIONS NETWORK SERVICES (FTNS) OPERATORS IN HONG KONG FOR VOICEBAND OPERATION TELECOMMUNICATIONS AUTHORITY HONG KONG

FOREWORD 1. This specification is issued pursuant to Section 32D of the Telecommunications Ordinance (Cap. 106). This specification sets out the technical requirements for connection of customer premises equipment (CPE) to the leased line(s) / private circuit(s) provided by the Fixed Telecommunications Network Services (FTNS) operators in Hong Kong for voiceband operation. 2. Voiceband leased line or private circuit may be provided by any one of the FTNS operators in Hong Kong. CPE should comply with this specification for connection to the voiceband leased line or private circuit provided by the FTNS operators. The general technical characteristics of the FTNS networks are given in HKTA 2201. Supplementary information on network characteristics and services of the FTNS networks may be obtained direct from the operators. Contact information of the FTNS operators can be found in the information note OFTA I 412. 3. At present, the Office of the Telecommunications Authority (OFTA) operates a Hong Kong Telecommunications Equipment Evaluation and Certification ( HKTEC ) scheme. Details of the scheme can be found in the information note OFTA I 421. Under the scheme, suppliers or manufacturers may apply for certification of their customer premises equipment against this specification. The application procedures for certification of customer premises equipment can be found in the information note OFTA I 412. A label prescribed by the Telecommunications Authority (TA) may be affixed to the certified equipment. Details of the labelling arrangement can be found in the Standardisation Guide HKTA 3211. 4. The TA may amend any part of this specification as and when he deems necessary. 5. In case of doubt about the interpretation of this specification, the methods of carrying out the test and the validity of statements made by the manufacturers of the equipment, the decision of the TA shall be final. 6. The TA accepts no responsibility for the satisfactory performance of the CPE connected to the public telecommunications networks. The CPE is not normally evaluated against performance, reliability or quality-of-service parameters. 7. The HKTA specifications and information notes issued by the TA can be downloaded from OFTA s website at http://www.ofta.gov.hk. Enquiries about this specification may be directed to - Senior Telecommunications Engineer Standards Section Office of the Telecommunications Authority 29/F Wu Chung House 213 Queen s Road East Wanchai Hong Kong Fax: +852 2838 5004 Email: standards@ofta.gov.hk HKTA 2023 ISSUE 04 PAGE i

AMENDMENT TABLE Item Issue Paragraph Descriptions No. 1. Issue 2 Foreword Certification and labelling requirements are updated. 2. Issue 2 2.2 The safety requirement is referred to HKTA 2001. 3. Issue 3 1.1 The number of FTNS operators is not to be specified as it may change from time to time 4. Issue 3 2.1, 3.1.1 Editorial update 5. Issue 3 5.1 Add RJ plug and socket requirement 6. Issue 4 Foreword Update information on certification and labelling as a result of the accreditation of Certification Bodies (CBs). 7. Issue 4 Para. 2.2 & 6 The title of HKTA 2001 is updated 8. Issue 4 Para. 5.2 Reference to the standard on mechanical requirements of RJ plugs is changed from FCC Part 68 to TIA-968-A or TIA-1096-A. TIA-1096-A is added as a reference standard on the contact requirements of RJ plugs in addition to TIA TSB 31-B. 9. Issue 4 Para. 6 Add the reference standards BS 6312, TIA-968-A, TIA TSB-31-B and TIA-1096-A for the UK and RJ connectors. HKTA 2023 ISSUE 04 PAGE ii

CONTENT 1. SCOPE 2. ELECTRICAL SAFETY 3. PRIVATE CIRCUIT APPLICATIONS 4. TRANSMISSION REQUIREMENTS 5. INTERCONNECTION 6. REFERENCE HKTA 2023 ISSUE 04 PAGE iii

1. SCOPE 1.1 This network connection specification covers the minimum technical requirements of a CPE to be connected to private circuit(s) / leased line(s) provided by any one of the Fixed Telecommunications Network Services (FTNS) operators in Hong Kong for voiceband operation (300 to 3400 Hz). The scope of the specification covers - a. protection of the leased line(s) / private circuits network; b. safety hazard to the personnel using or working on the network; and c. interoperability and interconnectivity of the leased line(s) / private circuit(s) provided by any one of the FTNS operators. 2. ELECTRICAL SAFETY 2.1 Principle of Protection In order to safeguard operating personnel, users, and plant, it is essential to prevent the transmission of excessive voltages from the CPE into the telecommunications networks of FTNS operators in Hong Kong. 2.2 Safety Requirements The CPE shall comply with the following specification - HKTA 2001 - Compliance Test Specification - Safety and Electrical Protection Requirements for Subscriber Telecommunications Equipment HKTA 2023 ISSUE 04 PAGE 1

3. PRIVATE CIRCUIT APPLICATIONS 3.1 General 3.1.1 Various kinds of private circuit applications for connection of CPE to the voiceband private circuits are available in the local fixed telecommunications network. As the individual FTNS operator may offer applications such as the following, it is necessary to obtain further information from the FTNS operators with contact address as shown in paragraph 2 of Foreword in this specification. (i) (ii) PABX Bothway Tie 2-Wire/4-Wire E&M Tie (iii) Hot Line Service (iv) PABX Long-Line Extension Note : No other DC line signalling schemes will be transported over the private circuits. Where there is an application for tie line operation other than the types mentioned above, the provision of the circuit should be evaluated and agreed between the parties involved on case by case basis. 3.1.2 This is the CPE supplier/agent s responsibility to ensure that the application of tie line circuit, external extension or trunk-to-trunk connection (e.g. call forward, conference call, call transfer, etc.) will not cause degradation of transmission performance. In some cases, amplification may be required to compensate the line attenuation. 3.2 PABX Bothway Tie Line 3.2.1 This type of private circuit services for connection of two PABX systems at different ends employing 2-Wire bothway tie trunk. The PABX at either side may originate an outgoing call to the PABX at the other end. 3.2.2 In idle state, the tie trunk interface shall provide a nominal -48 V battery feed with the positive side connected to earth. 3.2.3 The tie trunk interface conforming the technical requirements for connection to the PSTN (both DEL and DDI line) will be considered to be compatible for the private circuit connection. The relevant technical requirements (e.g. seizure state, answer condition, DTMF/Loop-disconnect signalling) are stipulated in HKTA 2011 and HKTA 2013. HKTA 2023 ISSUE 04 PAGE 2

3.3 2-Wire/4-Wire E&M Tie Line 3.3.1 This private circuit supports transmission of voiceband analogue signals over 1 pair or 2 pairs of speech path; while the control signals are carried by the E&M leads. The block diagram of connection arrangement is depicted in figures 1 & 2 below - CPE T R E M FTNS Private Circuit T R E M CPE Figure 1 2-Wire E&M Tie Line Circuit CPE T R T1 R1 E M FTNS Private Circuit T R T1 R1 E M CPE Figure 2 4-Wire E&M Tie Line Circuit HKTA 2023 ISSUE 04 PAGE 3

3.3.2 E&M Signalling Type I & V E&M signalling (see figures 3 & 4 respectively) are employed for CPE-to- Network operation. Exchange Equipment CPE Equipment (e.g. PABX) Detector M Current Limiter -48 V Cable E Detector -48 V CPE Equipment : On-Hook (Idle) : Ground on M lead Off-Hook (Seizure/Answer) : Battery on M lead Exchange Equipment : On-Hook (Idle) : Open on E lead Off-Hook (Seizure/Answer) : Ground on E lead Figure 3 Type I E&M Signalling Configuration HKTA 2023 ISSUE 04 PAGE 4

Exchange Equipment CPE Equipment (e.g. PABX) -48 V Current Limiter + Detector M Cable E Detector -48 V CPE Equipment : On-Hook (Idle) : Open on M lead Off-Hook (Seizure/Answer) : Ground on M lead Exchange Equipment : On-Hook (Idle) : Open on E lead Off-Hook (Seizure/Answer) : Ground on E lead Figure 4 Type V E&M Signalling Configuration HKTA 2023 ISSUE 04 PAGE 5

3.3.3 The E&M leads electrical parameters of exchange equipment are listed below - Operating voltage Insulation resistance at E lead in idle state Resistance at E lead in seizure/answer state Detector Limit (Line limit) : -48 Vdc nominal : > 150 kω, w.r.t. Earth : < 50 Ω, exclusive of external cable resistance : 500 Ω per lead maximum 3.3.4 E&M Leads electrical requirements of CPE are listed below - The operating voltage Insulation resistance at M lead in type V in idle state Line current Limit Detector Limit (Line limit) Terminating impedance Address signalling : -48 Vdc nominal : > 150 kω, w.r.t. Earth : < 110 ma, with a test load of 50 Ω : > 500 Ω per lead : 600 Ω nominal : a. Tone dialling (DTMF signalling) over the speech path b. Pulse dialling over the E&M leads c. The technical requirements of DTMF signalling and pulse dialling are referred to the relevant paragraphs in HKTA 2011. 3.4 Hot-Line Service This type of private circuit provides automatic ringing signal (nominal 75 Vrms, 25 Hz) to the called party when the calling party goes off-hook state or vice versa. Speech path is set up once the called party goes off hook. In idle state, the private circuit supplies a nominal feeding voltage of -48 Vdc to the CPE at both ends. Its operation can be triggered by a close-loop circuit at either side of CPE. CPE conforming the technical requirements for connection to the public exchange line will be considered to be compatible for the private circuit connection. Relevant technical requirements (e.g. the on-hook and off-hook state conditions) are stipulated in HKTA 2011. HKTA 2023 ISSUE 04 PAGE 6

3.5 PABX Long Line Extension This private circuit is used to connect between a PABX extension interface at the local end and a CPE at remote end via FTNS s transmission facilities. The PABX extension is a 2- Wire analogue interface. The CPE shall conform to the following technical requirements - a. The battery feeding voltage of CPE presenting to the private circuit shall be -48 Vdc nominal, and the line current of the circuit shall not exceed 110 ma. b. The ringing voltage of CPE presented to the private circuit shall be 75 Vrms ± 20%, with ringing frequency of 25 Hz nominal. c. All other relevant signalling and transmission aspects such as on-hook state, off-hook state, DTMF/Loop-disconnect signalling, return loss, and etc. shall be identical to technical requirements stipulated in HKTA 2011. 4. TRANSMISSION REQUIREMENTS 4.1 General The private circuits have a nominal pass-band of 300 to 3400 Hz, with 600 ohm nominal terminating impedance. No D.C. potential shall be transmitted from the CPE to the private circuit. 4.2 In-Band Power Limit of Tone Signals The total power level of all transmitted signals in any 10 Hz band within the frequency range 0 to 4 khz shall not exceed the limit shown in Figure 5 below, when measured at the private circuit interface of the CPE which is connected to a test circuit of a 600 ohm nonreactive load. (dbm) -9-15 200 Hz 3200 Hz 3400 Hz -25 100 Hz (3400 Hz, -29 dbm) (4000 Hz, -33 dbm) 0 800 1600 2400 3200 4000 FREQUENCY (Hz) Figure 5 In-Band Maximum Power Limit HKTA 2023 ISSUE 04 PAGE 7

4.3 In-Band Power Limit of Speech or Music Signals The power level of all transmitted speech or music signals, when averaged over any 3- second intervals, shall not exceed -9 dbm within the frequency range 300 to 4000 Hz, when measured at the private circuit interface of the CPE which is connected to a test circuit of a 600 ohm non-reactive load. 4.4 Out-Band Power Limit For frequencies above 4 khz, the root-mean-square (RMS) voltage averaged over 100 ms and measured at the private circuit interface of the CPE shall not exceed the limits shown below - Centre Frequency of 8 khz Band (khz) 8 to 12 12 to 90 90 to 266 Maximum Voltage in All 8 khz Bands (dbv) -(6.4 + 12.6 log f) 23-40 log f -55 Terminating Impedance (ohms) 300 135 135 Where f = centre frequency in khz of each of the possible 8 khz bands beginning at 8 khz, and dbv = 20 log (voltage in volts). 4.5 Impedance Voiceband private circuits are designed at a nominal balanced impedance of 600 ohms. The CPE shall present a terminating impedance of 400 to 1200 ohms over the operating frequency range to the private circuit. 4.6 Amplifier Gain In order to limit the level of crosstalk reproduction, any amplifier gain of the CPE shall be limited such that a signal level of -57 dbm or below appearing at the private circuit interface of the CPE will not be reproduced to an intelligible level. 4.7 Impulse Noise The level of impulse noise transmitted to the private circuit by the CPE shall not exceed 2 V peak-to-peak. HKTA 2023 ISSUE 04 PAGE 8

5. INTERCONNECTION 5.1 Single-line CPE connection Private circuits are presented in either 2-wire or 4-wire format. The FTNS operator will provide a modular socket as the Interconnect Point (IP) between the CPE and the private circuit; the CPE shall be provided with a standard plug to facilitate connection to or disconnection from the socket. The standard types of socket provided in Hong Kong are as follows - (a) Standard UK type socket Details of the standard modular plug and socket for single-line interface are shown in Figure 6. For a 2-wire private circuit, the connection points shall be on Terminal No. 2 and 5 of the plug. For a 4-wire private circuit, the send pair of the CPE shall be on Terminal No. 2 and 5 of the plug, while the receive pair shall be on Terminal No. 3 and 4. Note: The network operator has ceased installing the UK type sockets since 1 February 2004. (b) Standard RJ socket The standard RJ socket provides an RJ-45 jack. Details of the socket are illustrated in Figures 7a and 7b. The RJ-45 jack is compatible with CPE equipped with either RJ-11 plug (6-position) or RJ-45 plug (8-position). Note: The network operators may supply other optional types of telephone sockets, such as sockets with more than one RJ-45 jack to meet the service demand of customers. The CPE shall provide modular plug for connection and disconnection to the socket provided by the network operator. Note: Hong Kong has implemented a plan for transition of the plug and socket system from UK type to RJ type. Both RJ and UK sockets will certainly co-exist during the transition as operators take time for the socket replacement. Suppliers may offer single-line CPE using DEL with UK plug or RJ plug to cater for the market need and demand during the transition. To help reduce the potential connection problem, CPE suppliers are encourages to provide their customers with appropriate UK-RJ adaptors or other means for plug conversion. However, in order to promote the use of the RJ system, the CPE seeking the certification after 1 February 2004 has been required to meet the RJ plug requirement. 5.2 Multi-Line Interconnection Where multiple number of private circuits are terminated at the same location, hard-wired termination may be employed as the IP in lieu of modular sockets. All wiring within the IP (e.g. Interface Disconnection Box with Krone strips) will be connected and disconnected by the corresponding FTNS operator. The supplier / agent of the CPE will provide the cabling to the CPE side of the IP. HKTA 2023 ISSUE 04 PAGE 9

To CPE To FTNS s network Green to Pin 4 Terminal Spades or Plug Unit as appropriate white to Pin 5 Modular Line Cord Blue to Pin 3 Red to Pin 2 UK Type Modular Line Cord Details X Pin N o. 1 2 3 4 5 6 M odular Plug Standard Socket D etail X Standard UK Type Jack Note : Plugs should conform to specification BS6312:1982. In addition, the following requirements must be complied with - a. Minimum plating on all contacts of plugs to be 2.5 micron of gold over 3 micron of nickel, over base metal. b. Ductility of the nickel undercoat plating should be well controlled so that there should be no cracking on the plating surfaces which could cause exposure of the substrate with sequential corrosion problems under extremely adverse environmental conditions. Figure 6 Standard UK modular plug and socket HKTA 2023 ISSUE 04 PAGE 10

RJ-11/RJ-45 Plug with Cord Standard RJ Socket Note: 1. For connection to the RJ-45 jack, the CPE should be provided with either RJ-11 (6-position) plug for 2-wire operation or RJ-45 (8-position) plug for 4-wire operation. 2. The RJ plugs should conform to the mechanical requirements as specified in TIA-968-A or TIA-1096-A. The hard gold contacts or contacts using alternative materials shall conform to the requirements of TIA TSB-31-B or TIA-1096-A. Figure 7a : RJ Plug and Standard RJ Socket L1 L2 L3 L4 L1 L3 L2 L4 W-BL BL W-G G O W-O BR Test Circuits (Note 1) + 1 + 3 2 + 4 W-BR + 470k VR=400V, 0.5W 470k 470k 470k RJ Jack 1 2 3 4 5 6 7 8 L3 L1 L4 L2 Marking (Note 2) IDC Terminals Note: 1. The diode-resistor test circuits are only incorporated in the master line socket. 2. The IDC connectors are labelled by numbers (1, 2, 3, 4) and colours (W=White, BL=Blue, O=Orange, G=Green, BR=Brown) for pair and polarity identification. 3. For sequential extension of unshielded twisted pair (UTP) wires from one socket to another. 4. The jack pin/pair assignment of a RJ socket is referred to designation T568A defined in TIA/EIA-568-B.1. 5. For Plain Old Telephone Service (POTS), L1 should be used. 6. For broadband services such as Ethernet, L2/L3 should be used. Figure 7b : Details of Standard RJ Socket HKTA 2023 ISSUE 04 PAGE 11

6. REFERENCE 6.1 HKTA 2001 - Compliance Test Specification - Safety and Electrical Protection Requirements for Subscriber Telecommunications Equipment issued by the Telecommunications Authority 6.2 Telephone Transmission Quality, Recommendations of P Series. ITU-T Blue Book, 1988 6.3 BS 6312: 1982 - Specification for Plugs for Use with British Telecommunications Line Jack Units issued by British Standards Institution 6.4 TIA-968-A Telecommunication - Telephone Terminal Equipment - Technical Requirements for Connection of Terminal Equipment to the Telephone Network issued by the Telecommunications Industry Association 6.5 TIA TSB-31-B - Part 68 Rationale and Measurement Guidelines issued by the Telecommunications Industry Association 6.6 TIA-1096-A Connector Requirements for Connection of Terminal Equipment to the Telephone Network issued by the Telecommunications Industry Association - End - HKTA 2023 ISSUE 04 PAGE 12