GURONIC Casting Resin The Alternative Encapsulant

Similar documents
SAFETY DATA SHEET According to 91/155 EC

: MR MUSCLE Window & Glass Cleaner

Material Safety Data Sheet

SAFETY DATA SHEET (according to EC directive 93/112/EC) Update : Version: 2.0 Date : TEGOAMIN BDE 100

SAFETY DATA SHEET (according to EC directive 93/112/EC) Update : Version: 2.0 Date : TEGOAMIN DMCHA

SAFETY DATA SHEET Revised edition no : 0 SDS/MSDS Date : 12 / 7 / 2012

US Safety Data Sheet GEAR OIL SAE 10W/30 GEAR OIL SAE 10W/30

Product Code: VLB ml cartridges. Substance Name EC No. CAS No. % by Wt Hazard Symbols n Butylacetate

92699, 92708, 92732, 53825, 53810, : D-55Y Yellow UV Leak Detection Dye Concentrate

This SDS adheres to the standards and regulatory requirements of Great Britain and may not meet the regulatory requirements in other countries.

SAFETY DATA SHEET Revised edition no : 0 SDS/MSDS Date : 12 / 7 / 2012

*** SAFETY DATA SHEET ***

SAFETY DATA SHEET DALER ROWNEY 1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING. Primer for Acrylic Paint

SAFETY DATA SHEET according to regulation (EC) no 1907/2006 Clinic Ace Version 3 (UK) Issue date 07/30/2008

SAFETY DATA SHEET according to EC directive 91/155/EEC

DuPont SUVA 123 Refrigerant

WINDEX ORIGINAL GLASS CLEANER

GESSO PRIMER WHITE DALER ROWNEY, 2 Corporate Drive, Cranbury, New Jersey, USA

SAFETY DATA SHEET Revised edition no : 0 SDS/MSDS Date : 13 / 7 / 2012

SAFETY DATA SHEET Revised edition no : 0 SDS/MSDS Date : 10 / 7 / 2012

1-Bromo-2,5-dimethoxybenzene

This SDS adheres to the standards and regulatory requirements of Great Britain and may not meet the regulatory requirements in other countries.

: DuPont SUVA 410A Refrigerant

: Water and Glycol Leak Detection Solution

: Bromothymol Blue-Phenol Red, Mixed Indicator

Manufacturer/supplier information. Street/postbox: P.O. Box 15408

SAFETY DATA SHEET according to EC directive 91/155/EEC

MATERIAL SAFETY DATA SHEET OF EPOXY ESTER KU 95 1/5

WINDEX COMMERCIAL LINE GLASS CLEANER WITH AMMONIA- D

PLEDGE MULTI-SURFACE CLEAN & DUST

SHOUT TRIPLE-ACTING LAUNDRY STAIN REMOVER

Safety Data Sheet. according to Regulation (EU) No. 1907/ Sulfuric Acid 1.0 N

1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING. Types : ASHRAE Refrigerant number designation: R-507

: DuPont SUVA 407C Refrigerant

WINDEX MULTI-SURFACE CLEANER - VINEGAR

MATERIAL SAFETY DATA SHEET TOILET BOWL SANITIZER

CAS-No. EC-No. Index-No. Concentration Benzyl carbazate

SAFETY DATA SHEET WINTERHALTER A81 BLUE ENZYME DRAIN CLEANER

SAFETY DATA SHEET. according to 1907/2006/EC, Article 31 CYTOFIXX (CYTOLOGICAL FIXATIVE)

DuPont ISCEON MO89 refrigerant

BioShield Paint Company

SAFETY DATA SHEET Revised edition no : 1 SDS/MSDS Date : 26 / 11 / 2012

: GLADE Aerosol - Lavender

Safety Data Sheet ACRYL 60 Revision date : 2013/01/29 Page: 1/6

OFF! DEEP WOODS SPORTSMEN INSECT REPELLENT I (PUMP SPRAY)

Safety Data Sheet Steam Cylinder Oil C 460

LITHIUM CARBONATE, 1% AQUEOUS

EU Safety Data Sheet. Vival NF. Vival NF

SAFETY DATA SHEET Revised edition no : 0 SDS/MSDS Date : 18 / 7 / 2012

WINDEX ORIGINAL GLASS CLEANER WITH AMMONIA-D

Current version : 2.0.1, issued: Replaced version: 2.0.0, issued: Region: GB

advice (show the label where possible).

SAFETY DATA SHEET TIDYFOAM E2 HAND CLEANER SANITIZER

VERTREL XP Cleaning agent

M ATERIAL SAFETY DATA SHEET PRODUCT : Stopak Silica Gel Rev 1

: Mystic Home Pest Control

: 3-Chloro-4-methoxybenzoic acid

Essential Oils Direct Ltd

1. Identification of the substance/preparation and of the company/undertaking. EC-No. CAS-No. Chemical name Quantity Classification

MOL Biohyd 46 biodegradable hydraulic oil

Material Safety Data Sheet

OFF! CLIP-ON MOSQUITO REPELLENT

PRODUCT SAFETY DATA SHEET According to 91/155 EC 1. IDENTIFICATION OF THE SUBSTANCE / PREPARATION AND OF THE COMPANY / UNDERTAKING

WINDEX ORIGINAL GLASS CLEANER

: WOLF RADIATOR SEALER & CONDITIONER

Safety Data Sheet Primasol Deaerator NF (Primasol NF) Revision date : 2012/01/14 Page: 1/6

: DuPont SUVA 134aUV Leakdetect

Safety Data Sheet Laropal A 81 Revision date : 2011/06/15 Page: 1/6

SAFETY DATA SHEET EVO-STIK GRIPFILL SOLVENT FREE (Irl)

Material Safety Data Sheet

1. IDENTIFICATION of THE SUBSTANCE/PREPARATION and COMPANY

Safety data sheet. May cause slight irritation to the skin and eyes.

FANTASTIK SCRUBBING BUBBLES ALL PURPOSE CLEANER HEAVY DUTY

: 1-Amino-2-Naphthol-4-Sulfonic Acid

Sodium Sulphite Anhydrous

SAFETY DATA SHEET. according to Regulation (EC) No. 1907/ IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING

: Fairy Professional Original Washing Up Liquid 5L

SAFETY DATA SHEET (REACH regulation (EC) n 1907/ n 453/2010)

Product Name: Phone: Items: Formula Code:

Version: 1.0 Revision Date: 06/25/2013 Print Date: 06/25/2013 POOL TIME D.E. FILTER POWDER

SAFETY DATA SHEET CLEENOL LIFT ORIGINAL MULTIPURPOSE CLEANER

Material Safety Data Sheet in accordance with 91/155/EEC

Version 1.4 Print Date 01/14/2008 Revision Date 01/14/2008. Component CAS-No. Weight %

SCRUBBING BUBBLES VANISH CONTINUOUS CLEAN DROP- INS

MATERIAL SAFETY DATA SHEET

SAFETY DATA SHEET BOSTIK AQUAGRIP 536

SIGMA-ALDRICH. Material Safety Data Sheet Version 4.0 Revision Date 02/27/2010 Print Date 08/25/2011

Safety Data Sheet. Hazard Statements: H334: May cause allergy or asthma symptoms or breathing difficulties if inhaled

CeramClean II Aluminum Safe

1. Product and Company Identification

PLEDGE WITH FUTURE SHINE PREMIUM FLOOR FINISH

Material Safety Data Sheet According to 91/155 EC, 93/112/EC, 2001/58/EC

SECTION 3: COMPOSITION/INFORMATION ON INGREDIENTS 3.1. Substances Not applicable 3.2. Mixture

DuPont "Teflon" Dry Multi-Use Lubricant

SECTION 1: Identification of the substance/mixture and of the company/undertaking

Safety Data Sheet according to 1907/2006/EC, Article 31 Printing date: Revision:

CAS-No. EC-No. Index-No. Concentration Controlled Pore Glass May be harmful if inhaled. May cause respiratory tract irritation.

SAFETY DATA SHEET. Section 1: Identification of the substance/mixture and of the company/undertaking. KaVo Everest ZS-Blanks und Ronden

Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II and Regulation (EC) No. 1272/2008 (CLP) - Europe. Bona Wood Floor Cleaner

Transcription:

GURONIC Casting Resin The Alternative Encapsulant

GURONIC Casting Resin for Electronics Properties Details Advantages Mechanical Properties soft-elastic - excellent mechanical damping up to 1000 G - reliable protection against vibration and shock - extremely low stress on parts and soldered joints - re-enterable, repair possible Electrical Properties good dielectric - excellent electrical insulation - high electric breakdown strength - minimal impact on electronics - safe to use even at high voltages Flexibility at Low Temperatures glass transition approx. - 80 C - resin stays soft at low temperatures - excellent mechanical damping especially at low temperatures - minimal stress on parts and soldered joints at low temperatures and during temperature shocks - protection against vibration and shock even at low temperatures Manufacturing - variable potlife - convenient mixing ratio (typically 1:1 to 3:1) - no exothermic reaction during cure - virtually no cure shrinkage - adjustable to process conditions - easy to manufacture - easy potting of big volumes Environmental safety class free according to 91/155/EWG - no solvents, no VOC - no epoxy - no isocyanate - no silicone - no special protective measures for production

The GURONIC product family Technical Data (valid for the cured material, if not stated otherwise) Standard blue elastic, flexible at low temp. B1N0 blue or beige elastic, flexible at low temp. Variants (fast cure / slow cure) B1 B2 B1N0 B5N0 Pot life at 23 C [HD 631.1 S2] 15 min 3 h 10 min 2 h Cure Time at 23 C until fully cured 12 h 72 h 12 h 72 h at 80 C until solid cure 45 min 3 h 25 min 3 h at 80 C until fully cured 2 h 9 h 1 h 8 h Mixing ratio by weight 2 : 1 2 : 1 by volume 1.38 : 1 1.34 : 1 Viscosity of fresh mixture [Pa s] at 20 C [DIN 53019] 5 25 at 50 C 1 4 Temperature rise during cure none none Chemical base of resin and hardener Modified hydrocarbon resin. Not safety Density of cured product [g/cm 3 ] [EN ISO 1183-1] 1.18 1.21 Glass transition temperature [ C] [DIN 53445] -82.5-78 Typical operation temperature range [ C] -70 to +85-70 to +120 Hardness Shore A [ISO 868] A 10 A 20 Tear strength [N/mm 2 ] [ISO 527] 0,5 0.9 Elongation at break [%] [ISO 527] 89 170 Dielectric breakdown strength [kv/mm] [DIN VDE 0370 / IEC 156] 15 15 Relative permittivity ε r (0 C - 50 C, 10 Hz - 10 5 Hz) 2.5 to 2.6 2.2 Thermal conductivity [W/(mK)] at 23 C 0,25 0.31 linear - [K -1 ] 3.3 x10-4 2.1 x10-4 Thermal expansion coefficient (20 C to 100 C) cubic - [K -1 ] 5.5 x10-4 Water uptake [%] [DIN EN ISO 62] 0.2 ca. 0.2 n.m. = not measure The data presented in this leaflet are in accordance with the present state of our knowledge, but do not release the user from checking all supplies carefully. We reserve the right to alter product data within the scope of technical process or new developments. The mechanical properties of the cured materials are measured after standard cure conditions (24 h 23 C, 24 h 80 C) according to HD 631.1 S2.

C400-0 FY15-H FR D0FR0 P500-H transparent brown brown brown transparent elastic, hard-elastic, elastic, elastic, soft-elastic, flexible at low temp. flexible at low temp. self-extinguishing self-extinguishing, flexible at low temp., transparent UL 94 V-0 UL 94 V-0 transparent C400-0 C500-0 FY15-H FR 5 D0FR0 0.15 P500-H 10 min 2 h 30 min 15 min 2 h 2 h 8 h 48 h 48 h 48 h 12 h 72 h 25 min 3 h 40 min 60 min 45 min 1 h 1 h 8 h 8 h 3 h 2 h 12 h 1 : 1 1,2 : 1 4 : 1 4 : 1 5 : 3 1 : 1 1 : 1.07 2.35 : 1 2.32 : 1 5 : 3 7 25 33 60 24 1.5 5.5 5 7.5 4.7 none none none none none classified. Not hazardous flame retardant 0.94 1.03 1.40 1.48 0.96-78 ca. -65-82 -75 ca. -50-70 to +120-50 to +100-70 to +90-65 to +130-40 to +120 A 15 A 44 A 10 A 25 A 12 0.3 0.8 0.4 0.5 0.3 90 45 150 80 100 31 10 15 15 18 2.0 n.m. 2.9 to 3.0 3.6 to 3.7 3.0 to 3.8 0.2 ca. 0.3 0.37 0.52 ca. 0.2 2.2 x10-4 2.0 x10-4 3.1 x10-4 1.7 x10-4 2.2 x10-4 6.4 x10-4 6.1 x10-4 6.7 x10-4 ca. 0.2 ca. 0.2 0.3 ca. 0.3 ca. 0.2

GURONIC Casting Resin for Electronics TE Connectivity, a first choice partner when it comes to developing new materials and offering services tailored to your needs. You have not found the right material in our assortment? We also offer customized resin formulation and development services. Whatever your project may entail, we will provide the expert consulting you need to make it a success. Potting resin production GURONIC C400-0 twin cartridge Encapsulation Technology and Services Casting resins Materials consulting Customized development Casting and coating service Sample and pilot production Inspection and testing Tooling GURONIC gel GURONIC customized potting We provide the expertise and tailored services you need Phone hotline +49-(0)30-72 08 09 55 +49-(0)30-72 08 09 72 Fax +49-(0)30-72 08 09 59 e-mail guronic@te.com GURONIC products Tyco Electronics Raychem GmbH, Falkenberg site

GURONIC Casting Resin for Electronics 10000 100 GURONIC B1N0 1 0.9 0.8 0.7 0.6 0.5 Shear Modulus / MPa 0.4 1 0.3 0.2 0.1 0.01 0-200 -100 0 100 200 tan δ Temperature / C Shear Modulus and damping (tan δ) dependent on temperature for GURONIC B1N0, used to determine the glass transition temperature according to German industrial standard DIN 53445. GURONIC casting resins show excellent mechanical damping properties even at low temperatures. GURONIC is soft-elastic over the whole application temperature range. As a member of TE Connectivity we cultivate worldwide customer relationships with our international sales organization. For your applications we develop and manufacture high standard casting resins. Our company is certified according to OHSAS 18001, DIN EN ISO 9001 as well as to DIN EN ISO 14001. While TE Connectivity (TE) has made every reasonable effort to ensure the accuracy of the information in this catalog, TE does not guarantee that it is error-free, nor does TE make any other representation, warranty or guarantee that the information is accurate, correct, reliable or current. TE reserves the right to make any adjustments to the information contained herein at any time without notice. TE expressly disclaims all implied warranties regarding the information contained herein, including, but not limited to, any implied warranties of merchantability or fitness for a particular purpose. The dimensions in this catalog are for reference purposes only and are subject to change without notice. Specifications are subject to change without notice. Consult TE for the latest dimensions and design specifications. GURONIC, TE Connectivity and TE Connectivity (logo) are trademarks. TE Energy innovative and economical solutions for the electrical power industry: cable accessories, connectors & fittings, insulators & insulation, surge arresters, switching equipment, street lighting, power measurement and control. Tyco Electronics Raychem GmbH a TE Connectivity Ltd. Company TE Energy Trachenbergring 85 D-12249 Berlin 2011 Tyco Electronics Raychem GmbH EPP 1159 10/11 Phone: +49-30-720809-72 Fax: +49-30-720809-59 energy.te.com

GURONIC B1N0-0 Technical Data Sheet Properties of Components: Chemical base of component A and B: modified hydrocarbon resin Mixing ratio Component A : Component B by weight: 2 : 1 Mixing ratio Component A : Component B by volume: 1.34 : 1 Pot life at 23 C (HD 631.1 S2): ca. 10 min Cure time: at 23 C: ca. 12 h; at 80 C: ca. 1 h Exothermic reaction: none Volume shrinkage (EN ISO 3521): < 1 % Density at 23 C: component A: 1.40 g/cm 3 (EN ISO 1183-1) component B: 0.96 g/cm 3 final product: 1.21 g/cm 3 Viscosity of component A (DIN 53019): ca. 50 Pa s (20 C); 8 Pa s (60 C) Viscosity of component B (DIN 53019): ca. 7 Pa s (20 C); 2 Pa s (60 C) Viscosity of fresh mixture (DIN 53019): 25 Pa s (20 C); 4 Pa s (50 C) Dielectric strength at 23 C (VDE 0370/IEC 156): 15 kv/mm Properties of cured Product: State: soft elastic Colour: beige Hardness Shore A (ISO 868): 20 Tensile strength at 23 C (ISO 527): 0.9 N/mm² Elongation at break at 23 C (ISO 527): 170 % Reduction of weight at 150 C, 26 days (HD 631.1 S2): < 0.6 % Shear modulus at 23 C (DIN 53445): ca. 0.5 N/mm 2 Glass transition temperature (DIN 53445): -78 C Logarithmic decrement of mechanic attenuation (DIN 53445): 0.45 (23 C) or 2.7 ( -68 C) Relative permittivity (ε r ) at 10 C and 100 Hz: 2.20 50 C and 100 Hz: 2.17 10 C and 10 5 Hz: 2.19 50 C and 10 5 Hz: 2.15 Tangent delta (tgδ) at 10 C and 100 Hz: 3 x 10-3 50 C and 100 Hz: 3 x 10-3 10 C and 10 5 Hz: 5 x 10-3 50 C and 10 5 Hz: 4 x 10-3 Linear thermal coefficient of expansion: from -75 to -45 C: 2.3 x 10-4 K -1 from -20 to +100 C: 2.1 x 10-4 K -1 Thermal conductivity at 23 C: 0.31 W / (m K) Water absorption (DIN EN ISO 62): ca. 0.2 % Solubility in water: insoluble The data presented in this leaflet reflect the present state of our knowledge, but are not intended for use as a specification and do not release the user from checking all supplies carefully. We reserve the right to alter product specifications within the scope of technical process or new developments. 03/11

GURONIC B1N0-0 Component A - resin Page 1 of 4 EG-Safety Data Sheet according to REACH VO(EG) 1907/2006 0 Data Sheet Information Edition: 28.03.2011 Supersedes Edition: 02.09.2010 1 Identification of the Substance / Mixture and of the Company Commercial Name: Designated Use: GURONIC B1N0-0 Component A - resin cold applied two-component potting and casting resin Company: Tyco Electronics Raychem GmbH Phone: +49 (0) 35 36 54 47 40-0 Fax: +49 (0) 35 36 54 47 40-40 Address: Factory Falkenberg Hellsternstrasse 1 04895 Schmerkendorf Germany E-Mail: guronic@te.com 24 h Emergency Phone Number: Giftnotruf Berlin Phone: +49 (0) 30-19240 2 Hazards Identification Not classified according to Directive 1999/45/EC and CLP Regulation No. 1272/2008/EC. Specific hazards according to Human and Environment: Material has no hazard under normal working conditions. 3 Composition / Information of Ingredients Filled modified hydrocarbon resin Hazardous Ingredients : Substance: CAS-No.: EG-No.: Weight %: Symbol: --- --- --- --- ---

GURONIC B1N0-0 Component A - resin Page 2 of 4 4 First-Aid Measures General Advice: Inhalation of Aerosols or Vapour in High Concentration: Remove contaminated clothing immediately and wash thoroughly before reuse. Apply fresh air; consult medical attention in case of discomfort. Skin Contact: First wipe off, then wash thoroughly with water and soap. Apply skin cream. Eye Contact: In case of eye contact, immediately hold eyelids apart and rinse thoroughly with plenty of water for at least 15 minutes. Immediate medical attention required. Ingestion: Avoid vomiting, wash mouth thoroughly, drink plenty of water, consult medical attention. Advice for Physician: --- 5 Fire-Fighting Measures Suitable Extinguishing Media: Special Exposure Hazards: Protective Measures: Other Precautions: Dry powder, foam, CO2 Carbon monoxide and carbon dioxide may be released in case of fire. Wear self contained breathing apparatus in close proximity or confined spaces. Fire-fighters must wear fire resistant personnel protective equipment. Do not let contaminated fire fighting water enter drains. In case of surrounding fire, cool containers with water and remove them from danger zone if possible. 6 Accidental Release Measures Personal Precautions: Environmental Precautions: Methods for Cleaning Up: Recommended cleaning agents: Provide ventilation. Prevent discharges into soils, waters, sewers or drains. Soak up with inert absorbent material (e.g. sand, sawdust, oil absorber). Collect and dispose of in accordance with local regulation (see section 13). gasoline, petroleum, solvent 7 Handling and Storage Handling: Fire and Explosion Protection: Storage: Storage Temperature: -20 C to +40 C Recommended Storage Temperature: ~ +25 C. Good ventilation is to be provided/ installed at the working place. Keep away from ignition sources. Store in closed container in dry, well-ventilated and cold area. Keep separated from food.

GURONIC B1N0-0 Component A - resin Page 3 of 4 8 Exposure Control and Personal Protection Exposure limits for the occurrence of respirable aerosols: Atmospheric Workplace Control Parameter TRGS 900: substance: CAS-Nr.: Type: Value: Unit: --- --- --- --- --- Exposure limits: Personal Protection: Respiratory Protection: Eye Protection: Hand Protection: Body Protection: General Protective Measures: Product does not contain relevant amounts of substances that are subject to working place monitoring. Respect the normal rules of industrial hygiene. Negligible Wear tightly fitting safety goggles. In case of a potential skin contact the use of PE gloves for single use give sufficient protection. These gloves resist penetration for more than 30 min. Damaged gloves should be replaced. Normally used protective clothing when handling with chemicals. Respect normal rules of industrial hygiene. Do not eat, drink or smoke during work. Keep food separated. Wash hands thoroughly before breaks and after work. Avoid contact with eyes, skin and clothing. Do not inhale vapours. 9 Physical and Chemical Properties Appearance: Colour: Odour: viscous beige specific Aggregate State Modification: Melting Point: n.a. Boiling Point: > 230 C Flash Point: > 200 C Ignition Temperature: n.d. Lower Explosion Limit (Vol-%): n.a. Upper Explosion Limit (Vol-%): n.a. Vapour Pressure (20 C): < 0.01 hpa Density at 23 C (EN ISO 1183-1): 1.4 g/cm³ Viscosity at 20 C (DIN 53019): ca. 50 Pa s Solubility: very low in water n. d.: not determined n.a.: not applicable

GURONIC B1N0-0 Component A - resin Page 4 of 4 10 Stability and Reactivity Conditions to Avoid: Excessive temperatures. Decomposition begins at ca. 200 C. Materials to Avoid: Avoid storage with flammable materials. Dangerous Reactions: No dangerous reaction when handled and stored properly. Hazardous Decomposition Products: No dangerous decomposition product when handled and stored properly. In case of fire carbon monoxide and carbon dioxide may be released. 11 Toxicological Information Acute Toxicity: Experiences with Humans: Practical Experiences: Sensitization: Additional Information: No health effects are known, if the normal rules of industrial hygiene are respected. The product may cause irritations by skin or eye contact. No effects are known. According to our present knowledge no adverse health effects are to be expected if handled properly and for the intended use only. 12 Ecological Information General information: Does not contain any heavy metals or PCB. 13 Disposal Considerations Recommendation: Accountability: Residues / void containers (recommendation): Dispose of in compliance with local/federal regulation. Consider the local regulations. Mix residues of resin with hardener in order to cure. Cured resin and empty containers may be added to domestic waste. 14 Transport Information Not classified as dangerous goods according to transport regulations (for land transport ADR / RID, inland waterway transport ADN/ADNR, sea transport IMDG, air transport IATA). 15 Regulatory Information Not classified according to Directive 1999/45/EC and CLP Regulation No. 1272/2008/EC. Water Hazard class: 2 (water hazard) 16 Other Information The information given in this Safety Data Sheet is correct to the best of our knowledge, experience and believe at the date of its publication. The information provided is designated only as guidance for safe handling, use, processing, storage, transportation, disposal and release and is not to be considered as warranty or quality specification. The information only relates to the specific material and use designated and may not be valid for combinations with any other materials or in any process, unless specified in the text.

GURONIC B1N0-0/ B3N0-0/ C300-0/ C350-0/ C400-0/ C500-0/ CH00-0S/ D0FR0 0.15/ B1S0-0 Component B -hardener Page 1 of 4 EC-Safety Data Sheet according to REACH VO(EC) 1907/2006 0 Data Sheet Information Edition: 16.07.2012 Supersedes Edition: 21.03.2011 1 Identification of the Substance / Mixture and of the Company Commercial Name: Designated Use: GURONIC B1N0-0/ B3N0-0/ C300-0/ C350-0/ C400-0/ C500-0/ CH00-0S/ D0FR0 0.15/ B1S0-0 Component B - hardener cold applied two-component potting and casting resin Company: Tyco Electronics Raychem GmbH Phone: +49 (0) 35 36 54 47 40-0 Fax: +49 (0) 35 36 54 47 40-40 Address: Factory Falkenberg Hellsternstrasse 1 04895 Schmerkendorf Germany E-Mail: guronic@te.com 24 h Emergency Phone Number: Giftnotruf Berlin Phone: +49 (0) 30-19240 2 Hazards Identification Not classified according to Directive 67/548/EEC and CLP Regulation No. 1272/2008/EC. Specific hazards according to Human and Environment: Material has no hazard under normal working conditions. 3 Composition / Information of Ingredients modified hydrocarbon resin. Hazardous Ingredients : Substance: CAS-No.: EG-No.: Weight %: Symbol: --- --- --- --- ---

GURONIC B1N0-0/ B3N0-0/ C300-0/ C350-0/ C400-0/ C500-0/ CH00-0S/ D0FR0 0.15/ B1S0-0 Component B -hardener Page 2 of 4 4 First-Aid Measures General Advice: Remove contaminated clothing immediately and wash thoroughly before reuse. Inhalation of Aerosols or Vapour in High Concentration: Apply fresh air; consult medical attention in case of discomfort. Skin Contact: First wipe off, then wash thoroughly with water and soap. Apply skin cream. Eye Contact: Rinse thoroughly with plenty of water for at least 15 minutes. Immediate medical attention required. Ingestion: Avoid vomiting, wash mouth thoroughly, drink plenty of water, consult medical attention. Advice for Physician: --- 5 Fire-Fighting Measures Suitable Extinguishing Media: Special Exposure Hazards: Protective Measures: Other Precautions: Dry powder, foam, CO2. Carbon monoxide, carbon dioxide and irritating vapours may be released in case of fire. Wear self contained breathing apparatus. Fire-fighters must wear fire resistant personnel protective equipment. Do not inhale combustion gas. Do not let contaminated fire fighting water enter drains. Possible pressure build-up and burst of containers in case of surrounding fire. Cool containers with water spray and remove them from danger zone if possible. 6 Accidental Release Measures Personal Precautions: No special measures necessary. Avoid eye and skin contact. Environmental Precautions: Prevent discharges into soils, waters, sewers or drains. Methods for Cleaning Up: Soak up with inert absorbent material (e.g. sand, sawdust, oil absorber). Collect and dispose of in accordance with local regulation (see section 13). Recommended cleaning agents: gasoline, petroleum, solvent 7 Handling and Storage Handling: Fire and Explosion Protection: Storage: Storage Temperature: -20 C to +40 C Recommended Storage Temperature: ~ +25 C General precautions for handling of chemicals have to be regarded. Keep away from heat and ignition sources. Store in closed container in dry, well-ventilated and cold area. Keep separated from food. Prevent contact with air/oxygen.

GURONIC B1N0-0/ B3N0-0/ C300-0/ C350-0/ C400-0/ C500-0/ CH00-0S/ D0FR0 0.15/ B1S0-0 Component B -hardener Page 3 of 4 8 Exposure Control and Personal Protection Exposure limits: Product does not contain relevant amounts of substances that are subject to working place monitoring. Technical Protection Measures: Use closed processing equipment if possible. Personal Protection: Respect the normal rules of industrial hygiene Respiratory Protection: Negligible Eye Protection: Tightly fitting safety goggles. Hand Protection: PE gloves for single use, resist penetration for more than 30 min. Damaged gloves should be replaced. Body Protection: Normally used protective clothing when handling with chemicals. General Protective Measures: Respect normal rules of industrial hygiene. Do not eat, drink or smoke during work. Keep food separated. Wash hands thoroughly before breaks and after work. Avoid contact with eyes, skin and clothing. Do not inhale vapours. 9 Physical and Chemical Properties Appearance: Colour: Odour: liquid transparent light yellow specific Aggregate State Modification: Melting Point: n.d. Boiling Point: n.d. Flash Point: ca. 300 C Ignition Temperature: ca. 360 C Lower Explosion Limit (Vol-%): n.a. Upper Explosion Limit (Vol-%): n.a. Vapour Pressure (20 C): < 0.01 hpa Density at 23 C (EN ISO 1183-1): 0.96 g/cm³ Viscosity at 20 C (DIN 53019): ca. 7 Pa s Solubility: insoluble in water n. d.: not determined n.a.: not applicable 10 Stability and Reactivity Conditions to Avoid: Excessive temperatures. Decomposition begins at ca. 300 C. Protect against damp and light. Materials to Avoid: Prevent contact with air/oxygen. Dangerous Reactions: Oxidized with air. Hazardous Decomposition Products: Carbon monoxide, carbon dioxide

GURONIC B1N0-0/ B3N0-0/ C300-0/ C350-0/ C400-0/ C500-0/ CH00-0S/ D0FR0 0.15/ B1S0-0 Component B -hardener Page 4 of 4 11 Toxicological Information Acute Toxicity: LD50 (oral, rat): Skin: Eyes: > 10000 mg/kg No irritating effects known. No irritating effects known. 12 Ecological Information General information: Does not contain any heavy metals or PCB. 13 Disposal Considerations Recommendation: Accountability: Residues / void containers (recommendation): Dispose of in compliance with local/federal regulation. Consider the local regulations. Mix residues of resin with hardener in order to cure. Cured resin and empty containers may be added to domestic waste. 14 Transport Information Not classified as dangerous goods according to transport regulations (for land transport ADR / RID, inland waterway transport ADN/ADNR, sea transport IMDG, air transport IATA). 15 Regulatory Information Not classified according to Directive 67/548/EEC and CLP Regulation No. 1272/2008/EC. Water Hazard class: 1 (weak water hazard) 16 Other Information The information given in this Safety Data Sheet is correct to the best of our knowledge, experience and believe at the date of its publication. The information provided is designated only as guidance for safe handling, use, processing, storage, transportation, disposal and release and is not to be considered as warranty or quality specification. The information only relates to the specific material and use designated and may not be valid for combinations with any other materials or in any process, unless specified in the text.