WHAT IS ELECTRICAL SAFETY?

Similar documents
Residual Current Circuit Breaker

MODULE 1 INTRODUCTION TO ELECTRICAL SAFETY

Are you aware. Outline

Unit 4: Electricity (Part 2)

3053 Electrical Safety Training Program Course Outline

Installation Instructions for Alarm Module Kit A043F059

Types of electrical injuries

Analyzing Electrical Hazards in the Workplace

Installation and safety instructions for AC/DC built-in devices

Electrical Safety Health Worker Safety Training Module 6

Occupational Health Program Safety Training Series. Lockout/Tagout Safety Awareness Training

Dielectric Withstand Testing in a Production Environment

What s up with Arc Flash?

Laboratory Safety Guideline Electrical Safety

Section B: Electricity

SAFE ELECTRICAL WORK PRACTICES & 2015 NFPA 70E

Electrocution Hazards

100% Rule Alternate Method Arc Blast Arc Flash Approved Approved Equipment Authority Having Jurisdiction (AHJ) Authorized Work Bare Hand Work

3088 Lockout-Tagout Training Program Course Outline

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE CONSTRUCTION SAFETY STANDARDS

Union County Public Schools. Facilities Department. Electrical. Safe Work Practices

The Other Hazard of Electricity. Larren Elliott Ph.D. Lindsay Polic, CSP, REHS

Best Methods for Safe Hipot Testing

Common Sense and Knowledge Approach to Electrical Safety

Roadmap to Compliance with NFPA 70E Arc Flash Requirements

October Safety Subject

Fire Protection Notice No. 9 ELECTRICAL SAFETY

Understanding Arc Flash

Electrical Resistance Resistance (R)

Electrical Safety Tips. Help us keep you safe

MV, HV AND EHV SWITCHGEAR TESTING & COMMISSIONING

INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE SAFETY BULLETIN #23

Electrical Grounding. Appendix C

ELECTRICAL SAFETY. The standard unit for measuring electrical current.

BRANDON AND CLARK INC. // SCOTT W. CLARK, P.E. ELECTRICAL CONTINUING EDUCATION ARC FLASH - NFPA 70E

6.0 Electrical Installations

ADM1TE 5/30A DIN rail single phase two wire energy meter

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

CAPACITOR BANK TESTING SWP

1 Introduction. 2 Hazards From Electricity

IMPORTANT SAFETY NOTICE

Electrical Safety Training for the Manufacturing Industry

Basic Safety Examination instructions

Electrical safety and you

Infrarot-Bewegungsmelder IP44

The Level of Awareness on Electrical Hazards and Safety Measures among Residential Electricity User s in Minna Metropolis of Niger State, Nigeria

Heading FACT SHEET. Overview.

MANCON Human Resources Workers Compensation or ext 312 or

LOCKOUT GUIDELINE. To ensure that a piece of equipment cannot be turned on, pressurized or switched on accidently while an employee is working on it.

Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

Unified requirements for systems with voltages above 1 kv up to 15 kv

Grounding and Bonding Against Static Electricity. Jon Koppari, CSP, MS Occupational Safety and Health Instructor OSHA Training Institute

Work in Substations - General

Model 1756 Test Lead Kit

Why Construction Workers are Getting Electrocuted

ELECTRIC HEATER COMPANY Operating and Maintenance Manual For Immersion Heating Elements

Guide to the Safety, Health and Welfare at Work (General Application) Regulations Part 3: Electricity

NFPA 70E 2012 Rolls Out New Electrical Safety Requirements Affecting Data Centers

Regulation IO-6.0: Electrical Safety Regulations

400 Amp Rechargeable Jump Start System RAC-HP082

Electrical Death. National Forensic Service Gwangju Institute. Forensic Medicine Division. Na, Joo Young

Operating Instructions Split System Air Conditioner

Introduction to Arc Flash

Metal welding safety. Guidance Note. Practical advice for employers on controlling hazards when welding. June Background. How to use the table

Choosing the Best Solution for Reducing Arc Energy

Complete Solar Photovoltaics Steven Magee. Health and Safety

NFPA 70E Updates Affect Your Most Valuable Assets

How to reduce exposure to arc flash hazards

Ducoterra Radiant Heating Panel Installation Manual

Fault location on power cables. Fault location on power cables

Electrical Safety in the Marine Environment

AIR-CONDITIONER SPLIT TYPE

INTRODUCTION ARC FLASH PROTECTION AND SAFETY MEASURES. September 2010

PROCEDURES PREVENTION OF ACCIDENTAL IGNITION

CHECKING AND TESTING ELECTRICAL INSTALLING WORK

Transmission Business Electrical Incident & Safety Performance Reporting Guide

SL280UHV SERIES GAS FURNACE WARNING

OSHA 29CFR1910 Subpart S

Master Workplace Inspection Checklist for General Shop Safety. MASTER WORKPLACE INSPECTION CHECKLIST General Shop Safety

TIG INVERTER INSTRUCTION MANUAL

PROTECTION AGAINST ELECTRIC SHOCK by John Ware

HOUSING QUALITY STANDARDS (HQS)

Common Electrical Hazards in the Workplace Including Arc Flash. Presented by Ken Cohen, PhD, PE & CIH (Ret.)

This Guidance Notes is prepared by the Occupational Safety and Health Branch, Labour Department. This edition July 2004

HAZARDS, INCLUDING SHOCK, ARC FLASH AND FIRE

Release: 2. UEENEEJ194A Solve problems in low voltage refrigeration circuits

Guide to the electrical parameter classifications of IEC and IEC safety standards

Electrical Wiring Methods, Components and Equipment for General Use. Approved for Public Release; Further Dissemination Unlimited

PowlVac Vacuum Integrity Tester

Determining the Cause of AFCI Tripping Branch/Feeder and Combination Arc Fault Circuit Interrupters Class 760

INTRODUCTION INTERLOCK KIT K-8110

Arc Flash Avoidance and its Application to Overhead Traveling Cranes

Controlling Static Electricity in Modern Buildings

employed to ensure the continuing reliability of critical systems.

Instruction manual for Firstline FCS12000CH

High Voltage (HV) Electricity System Safety Rules and Associated Safety Guidance

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

Transcription:

ELECTRICAL SAFETY 1

WHAT IS ELECTRICAL SAFETY? ELECTRICAL SAFETY CAN BE DEFINED AS RECOGNIZING HAZARDS ASSOCIATED WITH THE USE OF ELECTRICAL ENERGY AND TAKING PRECAUTIONS SO THAT HAZARDS DO NOT PRODUCE INJURY OR DEATH. ELECTRICAL HAZARDS INCLUDE A DANGEROUS CONDITION SUCH THAT CONTACT OR EQUIPMENT FAILURE CAN RESULT IN ELECTRIC SHOCK, ARC-FLASH BURN, THERMAL BURN OR BLAST. 2

WHY ELECTRICAL SAFETY IS REQUIRED? ELECTRICAL ENERGY IS THE MOST COMMONLY USED FORM OF ENERGY. ONE CAN NOT IMAGINE LIFE WITHOUT ELECTRICITY IN MODERN SOCIETY. USING ELECTRICITY IS VERY SIMPLE, BUT, LITTLE DOES ONE KNOW ABOUT HOW ELECTRICITY REALY WORKS. IT CAN CAUSE INSTANTANIOUS DEATH, LIFE LONG DISABILITY DUE TO SEVERE BURNS OR DEVASTATING FIRES TURNING CRORES OF RUPEES WORTH PROPERTY TO ASHES. 3

WHY ELECTRICAL SAFETY IS REQUIRED? IT IS THEREFORE ABSOLUTELY ESSENTIAL THAT ONE SHOULD KNOW SOME OF THE BASIC PRINCIPLES OF ELECTRICITY. WHAT ARE THE HAZARDS IN USING IT AND WHAT SHOULD BE DONE TO AVOID EXPOSURE TO THESE HAZARDS? 4

BASIC PRINCIPLES OF ELECTRICAL SAFETY AVOID INADVERTENT CONACT. IF ACCIDENTAL CONTACT ESTABLISHES, SEE THAT THE MAGNITUDE OF CURRENT IS MINIMUM, IT IS NOT THROUGH VITAL BODY ORGANS, OR THE TIME OF PASSAGE IS THE LEAST. DO NOT ALLOW HIGH TEMPERATURE SPOTS, SPARKS. 5

ELECTRICAL HAZARDS * IT CAN BE BROADLY CLASSIFIED IN TWO MAIN CATEGORIES. A) TO LIVING HUMAN BEINGS I. ELECTRIC SHOCK CAUSE BY STATIC CHARGE & ELECTRIC CHARGE II. BURNS III. FALLS CAUSED BY ELECTRIC SHOCK B) TO PROPERTY A) I. WHAT IS ELECTRIC SHOCK? ELECTRIC SHOCK IS THE NET EFFECT OF THE DIRECT PASSAGE OF THE CURRENT THROUGH A HUMAN BODY WHEN IT ACCIDENTLY BRIDGES THE GAP BETWEEN TWO POTENTIALLY DIFFERENT POINTS. SHOCK IS NOT A PHENOMENON BUT IS A GENERAL TERM FOR THE EXCITATION OR DISTURBANCE OF THE FUNCTION OF NERVES OR MUSCLES CAUSED BY THE PASSAGE OF AN ELECTRIC CURRENT. 6

HUMAN RESISTANCE TO ELECTRIC CURRENT BODY AREA RESISTANCE (OHMS) DRY SKIN 100000 600000 WET SKIN 1000 INTERNAL BODY 400 600 (HAND TO FOOT) EAR TO EAR 100 7

BODY RESISTANCE BODY RESISTANCE IS INVERSELY TO THE SQUARE OF THE APPLIED VOLTAGE. FOR WOMEN AND CHILDREN THE VALUE OF BODY RESISTANCE SHOULD BE TAKEN AS HALF WHAT IS GIVEN ABOVE. FOR DC THE VALUE OF RESISTANCE SHOULD BE TAKEN AS FOUR TIMES THAT OF AC FOR THE SAME VALUE OF VOLTAGE. OVER AND ABOVE THIS WE MUST ADD THE RESISTANCE OF OUR FOOT AND FOOTWEAR. SO IT IS NORMALLY NOT POSSIBLE FOR ANY ONE TO GET FATAL SHOCKS UNLESS HE IS SO CARELESS AS TO TOUCH A LIVE LINE WITH WET HANDS OR MOIST HANDS IN BARE FOOT. 8

STATIC CHARGE A STATIC ELECTRIC CHARGE IS CREATED WHENEVER TWO SURFACES CONTACT AND SEPARATE, AND AT LEAST ONE OF THE SURFACES HAS A HIGH RESISTANCE TO ELECTRICAL CURRENT (AND IS THEREFORE AN ELECTRICAL INSULATOR). PROPER GROUNDING AND BONDING IS USED TO ADDRESS THE DANGERS OF STATIC ELECTRICITY. IN ORDER FOR GROUNDING TO PROTECT, ALL SURFACES MUST BE BONDED TOGETHER AND GROUNDED TO EARTH. STATIC ELECTRICITY IS THEREBY RELEASED TO EARTH AS IT IS GENERATED, PREVENTING THE ACCUMULATION OF DANGEROUS CHARGES THAT MAY IGNITE FLAMMABLE / HAZARDOUS SUBSTANCES OR CAUSE SHOCKS. 9

RESIDUAL CHARGE A RESIDUAL ELECTRIC CHARGE IS PRESENT IN A ELECTRICAL SYSTEM EVEN WHEN IT IS ISOLATED BECAUSE OF INHERENT CAPACITANCE IN THE SYSTEM (CABLES, INSULATORS ETC) PROPER LOCAL GROUNDING IS DONE BEFORE STARTING ANY MAINTAINENCE WORK OM ELECTRICAL CIRCUIT TO RELEASED THIS RESIDUAL CHARGE TO EARTH AS IT MAY CAUSE SHOCK. 10

B) LOSS OF PROPERTY GENERATION OF HEAT IS PROPORTIONAL TO I2Rt. IF HEAT IS NOT DISIPATED PROPERLY OR ALLOWED UN CONTROLLABLY, CAN CAUSE THE ARC, HEATING OF THE MEDIUM, SURROUNDING AND THERE BY RESULT INTO FIRE. THE FIRE IS ALSO IMMINENT WHEN SPARKING TAKE PLACE DUE TO LOOSE CONTACT, PHASE TO PHASE, PHASE TO EARTH FAULTS, LIGHTING STROKE. STATIC ELECTRICITY, SUDDEN BREAKING OF LOADING CKT. CAUSING ARC. CHANCES OF FIRE ARE MORE IN HIGHLY INFLAMMABLE LOCATIONS LIKE GAS, OIL, EXPLOSIVE ETC. 11

EARTHING EARTHING MEANS TO CONNECT THE SYSTEM WITH MASS OF EARTH. THE FRAME OF EVERY METAL CASED ELECT. EQUIPMENT SHOULD BE EFFICIENTLY EARTHED, TO DRAIN AWAY LEAKAGE CURRENT/VOLTAGE DUE TO POOR / LOSS OF INSULATION, SO THAT IT MAY ALWAYS BE SAFE. R N SW. FUSE M EARTH FAULT Y B EARTH MASS OF EARTH FAULT CURRENT 12

EARTHING RESISTANCE INSTALLATION MAX. PER. VALUE LARGE POWER STATION MAJOR SUBSTATION SMALL SUBSTATION IN ALL OTHER CABLES EARTH CONT IN SIDE INSTALLATION 0.5 OHMS 1.0 OHMS 2.0 OHMS 8.0 OHMS 1.0 OHMS 13

EFFECTS * THE ELECTRIC CURRENT PASSING THROUGH BODY AFFECTS THE VITAL BODY SYSTEMS SUCH AS NERVOUS SYSTEM, RESPIRATORY SYSTEM,CARDIAC SYSTEM ETC. THE EFFECT OF PROGRESSIVELY INCREASING CURRENT VALUES ARE MAGNITUDE OF CURRENT EFFECT UP TO 10 m A TINGLING SENSATION 10 30 m A PAIN IS FELT IN THE MUSCLES. 30 80 m A PAIN INCREASES, MUSCULAR CONTRACTION OCCURS, 100 200 m A BREATHING BECOMES DIFFICULT. UNCONTROLLED SPASTIC SWITCHING OF HEART (VENTRICULAR FIBRILLATION). DISRUPTION OF BLOOD FLOW DEATH Above 200 m A INSTANT STOPPAGE OF HEART. 14

PRECAUTIONS NORMALLY WE ACHIEVE SAFETY FROM ELECTRICAL SHOCK BY FOLLOWING : 1. ISOLATION 2. INSULATION 3. CURRENT LIMITATION 4. EARTHING 15

PRECAUTIONS MAINTAIN ALL THE LIVE PARTS INACCESSIBLE BY USING SUITABLE BARRIER GUARDS, INTERLOCKS ETC. BEFORE STARTING WORK ON ANY INSTALLATION ENSURE THAT IT IS PROPERLY ISOLATED FROM MAINS, DISCHARGED AND EARTHED. DO NOT START WORK UNLESS YOU ARE FULLY KNOWLEDGEABLE ABOUT THE WORK, HAZARD INVOLVED AND CARE REQUIRED TO BE TAKEN WHILE WORKING.USE HANDGLOVES, RUBBER MATS, SAFETY SHOES WHILE WORKING.USE OF PROPER SIZE CABLES, FUSES, SWITCHES, PROTECTION ETC. SUITABLE FOR THE LOAD 16

PREVENTION 1. AS FAR AS POSSIBLE DON T TOUCH ANY ELECTRICAL THING BY LEFT HAND. 2. NEVER PLAY WITH ELECTRICITY AND DON T TAKE ANY CHANCE WITH APPLIANCES. 3. NEVER WORK BARE FOOTED. 4. MAKE IT A REGULAR PRACTICE TO CHECK YOUR EARTHING. 5. NEVER BE IN A HURRY WHILE WORKING ON HIGH VOLTAGE. 6. WHILE WORKING ON HIGH VOLTAGE SWITCH GEAR CHECK AND DOUBLE CHECK BEFORE CLOSING THE CIRCUIT BREAKER 17

ACCIDENT PREVENTION BY PLANNING SAFETY PLANNING BEFORE STARTING THE WORK DETERMINE LOCATION OF WORK DETERMINE VOLTAGE DETERMINE FIRE - EXPLOSION HAZARD 18

ACCIDENT PREVENTION EARTH MAT STUDY SAFETY ASPECTS OF EQUIPMENT SIGNS SYMBOLS TAGS BARRICADES ATTENDANTS 19

SIDE RULE S : SWITCH OFF I : ISOLATE D : DISCHARGE E : EARTH 20

SAFETY RULES MAINTENANCE WITH HT, EHT, OH FOLLOWING RULES AS FOLLOWS. SAFETY FIRST AND ALWAYS, IT PREVENTS ACCIDENT WHICH NORMALLY RESULT LOSS OF MAN HOURS AND EQUIPMENT. ALL LINES AND EQUIPMENT MUST BE CONSIDERED ENERGISED. ALL VOLTAGES MUST BE CONSIDERED DANGEROUS. ACCIDENT DON T JUST HAPPEN. ACCIDENTS ARE THE RESULT OF UNSAFE CONDITION OR UNSAFE ACTS OR COMBINATION OF BOTH. 21

CLERANCES Clearance above ground of the lowest conductor As per IE Rule 77 Over head Line Across Street Low and Medium Voltage 5.8 Meter High Voltage 6.1 Meter Over head Line Along Street (Parallel To Street) Low and Medium Voltage 5.5 Meter High Voltage 5.8 Meter Over head Line Without Across or Along Street Low/Medium /HT line up to 11KV If Bare Conductor Low/Medium /HT line up to 11KV If Insulated Conductor Above 11 KV Line Above 33KV Line 4.6 Meter 4.0 Meter 5.2 Meter 5.8 Meter + Add 0.3 meter for every additional 33KV 22

LOCK OUT/TAG OUT BREAKER LOCKED IN OFF POSITION TO ENSURE THE SAFETY OF REPAIR PERSONNEL, ELECTRICAL PANELS AND EQUIPMENT WITH ELECTRICAL PANELS MUST BE LOCKED OUT AND EQUIPMENT TAGGED OUT OF SERVICE BEFORE ANY REPAIRS ARE PERFORMED. THE LOCK MUST NEVER BE REMOVED FROM AN ELECTRICAL PANEL UNTIL REPAIRS HAVE BEEN COMPLETED, AND ONLY THEN BY AN INDIVIDUAL WITH THE APPROPRIATE AUTHORITY. REPAIRS MUST ONLY BE PERFORMED BY TRAINED PROFESSIONALS. 23

USE OF ELCB ELCB S GIVE PROTECTION BY AUTOMATIC DISCONNECTION OF SUPPLY AGAINST THE RISK OF DANGEROUS ELECTRIC SHOCK. CONTINUOUS HIGH EARTH LEAKAGE CURRENT CAN RESULT INTO FIRE WHICH CAN T BE INTERRUPTED BY MCB OR FUSE. ELCB PROVIDE HIGH DEGREE OF PROTECTION AGAINST ABOVE FAULT. AS PER I.E.RULE 61-A ELCB IS COMPULSORY FOR L.T. LOAD ABOVE 5KW. 24

THANK YOU 25