Supplemental sheet for special device SERIES AZ17E-600. Battery powered system with 868 MHz radio module

Similar documents
1 Technical Description Lokal-200PC

Bluetooth HC-06 with serial port module Easy guide

Bluetooth to Serial Adapter

HAC-LM Series Low Power Data Radio Module

Single channel data transceiver module WIZ2-434

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

GV- RK1352 Card Reader

USB Plus+ RFID Reader Setup Guide

[USING THE NM150 WITH ADULTICIDING] July 13, 2015

Bidirectional wireless communication using EmbedRF

1. SAFETY INFORMATION

Communication with BushingGard using computer USB port

Alpha 10 SERVICE MANUAL. Downloaded from MAX 10 Meter Amateur Transceiver AM/FM/CW/SSB 6 BAND PROGRAMMABLE MODEL AM-1000.

HAC-UM Series SHENZHEN HAC TECHNOLOGY CO., LTD. HAC-UM Series. Version 2.3C SHENZHEN HAC TELECOM TECHNOLOGY CO., LTD

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

USER MANUAL. VS-81H 8x1 HDMI Switcher MODEL: P/N: Rev 4

AutoWAVE. Programming Instructions P/N Part of Thermo Fisher Scientific. Revision D

Guangzhou HC Information Technology Co., Ltd. Product Data Sheet

iloq P10S.10/20 Programming device User's Guide

Operating instructions TSE Wireless Software Home

Rev GSM base station. Installation instructions

F2103 GPRS DTU USER MANUAL

MANUAL FOR RX700 LR and NR

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

STIM202 Evaluation Kit

Customer Pole Display SERIES 8035

CHD603BM-U USB Mifare Card Reader User Manual

s!nus-elektrotechnikai bt. Industrial IT & Automation

Using Xbee in Serial Communication

Signal-400 HDMI COFDM (DVB-T) Encoder & Modulator. --- Home Use

WPR400 Wireless Portable Reader

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

1-Port R422/485 Serial PCIe Card

s!nus-elektrotechnikai bt. Industrial IT & Automation

A RF18 Remote control receiver MODULE

Monitores Equipos Móviles Especificaciones de Producto

PM1122 INT DIGITAL INTERFACE REMOTE

Six-servo Robot Arm. DAGU Hi-Tech Electronic Co., LTD Six-servo Robot Arm

RN-WIFLY-EVAL-UM. WiFly Evaluation Kit Roving Networks. All rights reserved. RN-WIFLY-EVAL-UM Version 1.32r 10/9/2012 USER MANUAL

User Manual. AS-Interface Programmer

FOR MORE INFORMATION or from a non-telstra phone and say pre-paid telstra.com/ppmbb visit a telstra store or partner

WIRELESS INSTRUMENTATION TECHNOLOGY

USB Smart Power Sensor

Quick Start Guide. MRB-KW01 Development Platform Radio Utility Application Demo MODULAR REFERENCE BOARD

SDN INSTRUCTIONS 07/10, Ver 1.2. Somfy Digital Network (SDN) Installation and Programming

Serial Communications

PMAfob Home Automation Demo

User's Guide. Integrating Sound Level Datalogger. Model Introduction

IDD-213T User Manual. (Rev. 1.0) China Aerospace Telecommunications Limited

TP32MTT.03 TP32MTT [ GB ] Probes for soil thermal profile measurement

DAB1001. Wireless Digital Radio Interface. Installation & User Guide

Orbit PCI Mk 2 Network Card. User Manual. Part No Issue 4

Mobile Satellite Solutions. A WiWorld Partner SATELLITE TV ANTENNA CONTROLLER RFM-1000/1100 TECHNICAL MANUAL STOW SEARCH

User manual BETSO WTCS. 16 channel wireless digital TC slate. 1 Copyright BETSO ELECTRONICS Ltd.

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Software User Guide UG-461

Master-Touch and ValuMass. Modbus Communications. INSTRUCTION MANUAL (Rev. 2.1)

Manual Serial PCI Cards

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Guangzhou HC Information Technology Co., Ltd. Product Data Sheet

Guangzhou HC Information Technology Co., Ltd. Product Data Sheet

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

User Manual Revision English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD HD M HD HD M)

HTT 101. HDMI/YPbPr/S-Video/AV to DVB-T. HDMI/YPbPr/S Encoder Modulator

How to setup a serial Bluetooth adapter Master Guide

Wideband USB Synthesized Signal Generator. Dynamic range 70 db, output power from -60dBm to +10dBm in 0.25dB steps

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Secure My-d TM and Mifare TM RFID reader system by using a security access module Erich Englbrecht (info@eonline.de) V0.1draft

GETTING TO KNOW YOUR TELSTRA PRE-PAID 3G WI-FI

USER MANUAL V5.0 ST100

GETTING TO KNOW YOUR TELSTRA PRE-PAID 3G USB + WI-FI

PenMount 1302 PCI Control Board

RC-1SP4T-A18. Key Features. Mini-Circuits P.O. Box 35166, Brooklyn, NY (718)

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

IN-OUT Thermometer with Cable Free Sensor and Clock

2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide

Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

CMC-DN01 DeviceNet Slave Communication Card Operation Manual

Operating Manual UMB Analogue/Digital Converter ANACON Order Number: 8160.UANA

LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH - SECOND EDITION

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

User Guide Reflow Toaster Oven Controller

GETTING TO KNOW YOUR 4G USB

RS232 Programming and Troubleshooting Guide for Turbo Controls

Cable Connection Procedures for Cisco 1900 Series Routers

e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL

Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI

TS1 Ultra Sonic Tank Sender Training. 27 November 2007

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

BW-500 BED WEIGHER USER MANUAL

Targus Wireless Remote Presenter USER S GUIDE. Making Your Mobile Life Easier. Making Your Mobile Life Easier.

Barcode Reader Series BCL 31, BCL 32, BCL 34

Measuring electric and magnetic fields

Targus Wireless RF Mouse USER S GUIDE. Making Your Mobile Life Easier.

Wireless Link. Introduction. Setup, Configuration and Connection ENGLISH

USB I/O CONTROL BOX 8 relays, 8 digital I/O lines and 8 HV inputs

Transcription:

Supplemental sheet for special device SERIES AZ17E-600 Battery powered system with 868 MHz radio module

1. General... 3 2. Technical data... 4 3. Pin assignment... 5 3.1 indicator AZ17E-600 [Slave]... 5 3.2 RF-module 868 MHz RS232 [Master]... 5 4. Radio transmission... 6 4.1 Necessary settings... 6 4.2 Manual radio transmission... 6 4.3 Automatic radio transmission (P01 = 0xxxxx)... 6 4.4 Radio transmission protocol... 7 4.5 Addressing... 8 5. Parameter list... 9 6. Installation of Driver for RF module 868 MHz USB... 10 7. RS232 Terminal... 11 8. Mounting... 12 9. Order Designation... 12-2 -

1. General The battery powered measuring system AZ17E-600 [SLAVE] with external sensor AZS is equipped with an 868MHz radio module (ISM band) for the transfer of the actual value. As an accessory an 868MHz transceiver [MASTER] with RS232 or as a USB stick is available. The two-way radio link serves as a cable replacement between MASTER and SLAVE: ELGO shipment PC/SPS/etc Virtual comport USB RF-module USB stick 868 MHz Transceiver 868 MHz Air interface temporary active link AZ17E with integr. 868 MHz radio module AZ17E-6xx ELGO shipment RF-module RS 232 868 MHz Air interface AZ17E with integr. 868 MHz radio module PC/SPS/etc RS232 868 MHz Transceiver temporary active link AZ17E-6xx - 3 -

2. Technical data AZ17E-600 ELGO-measuring system Input supply voltage 1,5 V DC battery RF module 868 MHz RS232 [Master] Input supply voltage Housing dimensions Interface +10 30 VDC with inverse-polarity protection W x H x D = 55 x 51 x 28 (without mounting clips) RS232 9600 Baud / 8 data bits / 1 Stop bit / no parity RF module 868 MHz USB [Master] Connector communication Interface Driver USB 2.0 (Full-Speed) virtual COM-Port USB 9600 Baud / 8 data bits / 1 Stop bit / no parity USB Driver for WIN-2000 / -XP / -VISTA 868 MHz specification operating distance up to 200 m ( at intervisibility ) HF- data rate 38 kbps output rating typ. 2 dbm e.i.r.p. ( 10 dbm at 50 Ω ) input sensitivity up to -102 dbm ( -110 dbm at 50 Ω ) frequency range channel raster kind of modulation aerial topology transmission addressing 868-868,6 MHz 50 khz 2 - FSK, MSK integrated ceramic aerial point to point bidirectional / half-duplex / with receipt / with CRC check sum / 5 times repetition of non receipted radiograms 2 byte address range, max 64000 different addresses conformity ( Europe ) EN 300220-1, EN 301489-1/-3, EN 60950-1, EN 50371-4 -

3. Pin assignment 3.1 indicator AZ17E-600 [Slave] colour black red function 0V / GND + 1,5 VDC (Battery compartments optional) 3.2 RF-module 868 MHz RS232 [Master] colour function black 0V / GND brown + 10..30 VDC red RS232 RF-RX orange RS232 RF-TX blank shielding/earth (Open wired / 1 Meter cable length standard) - 5 -

4. Radio transmission 4.1 Necessary settings Parameter P 01 / Bit 5 P23 P24 P25 Function Here you can set if the transfer is to be made by pressing a key or automatically every 250 ms. Setting the destination network address of the Master Setting the destination address of the Masters Setting the transmission protocol type Manual radio transmission Press the button once Pressing this button the current actual position (display value) is transmitted per radio with the protocol which is set in parameter P90. This works only if the device is not in sleep mode. Reception Control: A successful transfer will be signalled in the LCD with symbol. about 3 seconds after the last successful transfer. The icon disappears automatically Automatic radio transmission (P01 = 0xxxxx) At this setting the current actual position (display value) is transmitted per radio with the protocol which is set in parameter P90 every 250 ms. This works only if the device is not in sleep mode. Reception Control: A successful transfer will be signalled in the LCD with symbol. about 3 seconds after the last successful transfer. The icon disappears automatically - 6 -

Radio transmission protocol Parameter P90 = 0: => RF transmission deactivated Parameter P90 = 1: Parameter P90 = 2: - 7 -

Addressing Both participants in the point-to-point connection must be clearly addressed to each other according to the following chart: Example addressing RF-module RS232 /USB 868 MHz Transceiver Particular network address: 25 (from factory fixed) Particular network address: 123 (from factory fixed) Destination network address: 150 Destination network address: 30 (Adjustable) 868 MHz Air interface temporary active link AZ17E with integr. 868 MHz radio module AZ17E-6xx Particular network address: 150 (from factory fixed) Particular network address: 30 (from factory fixed) Destination network address: 25 (Adjustable) Destination network address: 123-8 -

5. Parameter list Parameter: Description: Default: P01: ABCDEF system configuration: A = 0: RF-transmission every 250 ms A = 1: RF-transmission pressing SET B = 0: LCD in SLEEP mode deactivated B = 1: LCD in SLEEP mode activated C = 0: reserved, without function C = 1: reserved, without function D = 0: mm / Inch symbol deactivated D = 1: mm / Inch symbol activated E = 0: mm mode ( resolution 0,1 mm ) E = 1: Inch mode ( resolution 0,001 Inch ) F = 0: counting direction positive F = 1: counting direction negative P03: decimal point ( 0 3) 1 111100 P04: Auto-Power-Off-Time ( 1 99 seconds ) 10 s P05: ABC P08: P09: P10: P11: P12: P20: * P21: P22: P23:* P24:* key lock A: button Set ( 1 = active / 0 = not active ) B: button Incr/Abs ( 1 = active / 0 = not active ) C: button * ( 1 = active / 0 = not active ) multiplication factor ( 0,001 9,999 ) reference value ( -999999,9 + 999999,9 ) tool offset 1 ( -999999,9 + 999999,9 ) tool offset 2 ( -999999,9 + 999999,9 ) tool offset 3 ( -999999,9 + 999999,9 ) radio channel in preparation display: own RF network address (fixed) display: own RF address (fixed) destination RF network address ( 0 255) destination RF address ( 0 255) P90: type of protocol (0..2) 0: RF-transmission deactivated P99: display: firmware version 111 1,000 0,0 10,0 20,0 30,0 0 xxx xxx 0 0 2 x.xx * CAUTION: After a change in the parameters P20, P23 and P24 the device AZ17E-600-3-xx.x-1 has to be disconnected from the supply voltage for 1 minute, so that the parameters will be saved! - 9 -

6. Installation of Driver for RF module 868 MHz USB File: TREIBER_RF MODUL USB_W2K_XP_S2K3_VISTA Install: Run the file "AMBDriverInstaller.exe" and follow the instructions until the installation has been completed successfully. Connection USB sticks: The USB stick is used to connect to the PC to an available USB port. Windows will automatically recognize the new connected device. The Windows routine assignment for the driver will start automatically: 1. Highlight in the first window "No, not this time" and click "Next". 2. Highlight in the following window "software from a List or specific location" and click on "Next ". 3. Highlight in the following window "not search but search the driver to install itself and click "Next". 4. In the next window is a list of potential drivers. Select "AMB2560/AMB8460 RF module USB Flash" and click on "next". 5. Continue the following warning with click "Continue". 6. Click "Finish" in the last window At the initial installation a second time the Windows routine will be opened and steps 1. through 6. need to be progressed again. Serial Interface: The driver creates now a virtual serial port. The interface parameters are at shipment 9600 baud, 8 data bits, no parity and 1 stop bit. For use with the terminal program, the corresponding COM port in the device manager needs to be determined. - 10 -

7. RS232 Terminal For the commissioning of the system for the PC a small Terminal program is available: Over the button "CONFIG" the appropriate COM port can be set. The button "Start" or "STOP" opens or closes the set COM port. File: PC terminal RS232_Windows_V1-1 Install: Run the "setup.exe" and follow the instructions until the Installation is completed successfully. - 11 -

8. Mounting The AZ17E-600 should not be installed in a closed metal housing (the control cabinet, etc.) due to the integrated aerial/antenna. The device should be mounted 10cm away to metal parts and at least 1m distance to potential sources of interferences. The RF-MODULE 868MHz RS232/USB should be based on an elevated position and should not be hid by metal parts. A minimum distance of 1m from possible sources of interference has to be kept. Through the installation of MASTER and SLAVE resulting range has to be checked and may be optimized possibly by repositioning. 9. Order Designation Absolute Measuring system with radio module (SLAVE): AZ17E-600-3-xx.x-1 External sensor (xx.x = cable length in meter): AZS-000-1-xx.x-1 868MHz- Transceiver (MASTER) RS232: RF-MODULE 868MHz RS232 868MHz- Transceiver (MASTER) USB: RF-MODULE 868MHz USB Dok.-Nr. 799000357 AZ17E-600-E_36-08 Subject to change - 2008 ELGO Electronic GmbH & Co. KG - 12 -