In addition to Chart 1 (Life to First Maintenance) the following aspects of the serviceability of galvanized coatings should be taken into account:

Similar documents
FIRETEX FX Range. Intumescent protection for steel framed car parks

infosteel Guide to protection of steel against corrosion Indoor and outdoor structures 1st edition: May 2012 Value 10 EUR

stainless steel for coastal and salt corrosion DESIGNER HANDBOOK TABLE OF CONTENTS: INTRODUCTION CASE STUDY ONE: STREET LEVEL APPLICATIONS

Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method F (100 C) calculated VOC-US/Hong Kong. US EPA method 24 (tested)

White rust on galvanized and galvanized pre-painted steel. Technical Information

Durability of aluminium

Which Stainless Steel Should Be Specified for Exterior Applications?

Dissimilar Metal Corrosion

American Galvanizers Association

Chapter 2 Basis of design and materials

Protecting Galvanized Steel Sheet Products from Storage Stain Rev 2.1 Aug-03

ZINCROLYTE VS DUPLEX 700

Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 34 C IED (2010/75/EU) (calculated)

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

What Causes Climate? Use Target Reading Skills

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 27 C calculated IED (2010/75/EU) (calculated)

TITLE 1. DESIGN BASES CHAPTER II. GENERAL PRINCIPLES AND LIMIT STATE DESIGN

INDUSTRIAL ROOFING CASE STUDY: The Advantages of Aluminized Stainless Steel. Roof Installed:

THE USE OF STEEL BUILDING PANELS FOR ANIMAL CONFINEMENT

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 28 C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

Metal Rescue Rust Remover Technical Data

PAINTING OVER HOT DIP GALVANIZED STEEL

Evaluating Protective Coatings for Ballast Tanks

Climate Change and Infrastructure Planning Ahead

North American Stainless

Adhesive Recommendation for Altro Flooring. Porous (absorbent) subfloors (most wood subfloors and some concrete)

Why Steel? Performance Study of Steel Doors and Frames Compared to Other Materials. September Sponsored by SDI, HMMA, CSDMA

Cable Trays Technical Instructions & Specifications

Aluminized Steel Type 1 STAINLESS 409 and 439

Clean air solutions for turbo machinery

CATHODIC PROTECTION SYSTEM DESIGN

Advice to consumer Reference 50.1 May Condensation. Some causes, some advice.

Self Assessment Exercise

A corrosion protection guide For steel bearing piles in temperate climates

Are these noise cancelling devices needed to make your chiller quiet??

SURFACE PREPARATION STANDARDS

Asphalt Shingle Application Requirements

September 3, Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901

Approved. Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method 1 30 C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

The built environment : a policy framework for climate adaptation

STANDARDS FOR THE MATERIALS

MARTIN TESTING LABORATORIES (MTL) PAINTS AND COATINGS TESTING CAPABILITIES

Low VOC Performance Protection Systems

Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

expectation as hot dip galvanizing?

EXPERIMENT #9 CORROSION OF METALS

The Owners Coated Coil, Cleaning and Maintenance Service Manual.

CATHODIC PROTECTION OF REINFORCED CONCRETE STRUCTURES

Data Bulletin. Mounting Variable Frequency Drives in Electrical Enclosures Thermal Concerns OVERVIEW WHY VARIABLE FREQUENCY DRIVES THERMAL MANAGEMENT?

Understanding Coating Weight Designations for Zinc-Based Coatings on Steel Sheet Rev 2.2 Jan-04

Spandrel Glass Types and Recommendations

Division 9. SignaFlor Pad and Pour Flooring System

By: Jaap Hoogland SPX Cooling Technologies GmbH. CW /Jaap Hoogland/ Seawater Cooling Tower Circuits 1

CLIMATE, WATER & LIVING PATTERNS THINGS

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

Fire Event Electronic and Mechanical System Damage Mechanisms Is Acid Gas for Real?

Air Quality: Public Health Impacts and Local Actions

WATERPROOFING SYSTEMS IN BUILDING CONSTRUCTION

CONTENTS. 1 cooling technology white paper

DISTRIBUTION PIPING MATERIALS: BUILDING HYDRONIC SYSTEM MANAGEMENT. Jim Riley, Texas A&M University February 10, 2015

SIGMACOVER 300. PRODUCT DATA SHEET December 12, 2014 (Revision of November 1, 2013) DESCRIPTION

North American Stainless

Points of Construction

Process Control For Phosphate Coating A new military specification for phosphate coatings...

SALT SPRAY AND IMMERSION CORROSION TESTING OF PM STAINLESS STEEL MATERIALS. W. Brian James Hoeganaes Corporation. Cinnaminson, NJ 08077

Handling Corrosive or Abrasive Liquids

Molds and mildew are fungi that grow

CONDENSATION IN REFRIDGERATED BUILDINGS

Water Cycle. DELTA SCIENCE READER Overview Before Reading Guide the Reading After Reading

Application Guide Selection of Type Enclosures

Opening the Bonnet. Prof Darren Woolf WYSINWYG 1

Answers to Your Questions from the Webinar

Comparison of steel bridge coatings

THE ECOSYSTEM - Biomes

The IPCC Special Report on Managing the Risks of Extreme Events and Disasters to Advance Climate Change Adaptation

All Weather Hall. Efficient, multipurpose & quick to build

Water Damage & Repair

Special coating Corrotect. Anti-corrosion protection for rolling bearings and precision components

Metal Spray Supplies Australia P.O. Box 954 A.B.N Unit 8/37 Veronica Street Queensland 4157

ApplicatorTrainingBulletin. The Galvanized Surface. Surface Preparation of New Galvanizing

CORROSION PROTECTION METHODS OF STRUCTURAL STEEL AGAINST ATMOSPHERIC CORROSION

DIRECT PRINTING NYLON JACKETS. The Basics

North American Stainless

RPV - RP - RA air handling units

Fire Resistant Systems

A discussion of condensate removal systems for clarifier and thickener drives for water and wastewater facilities.

Durability of Galvanized Steel Framing in Residential Buildings

STEEL BUILDINGS IN EUROPE. Single-Storey Steel Buildings Part 8: Building Envelope

Cold trichloroethylene degreasing Film Thickness 70± 10 µm 10 minutes at 170 C (PZ 770 alone) 5 minutes 30 sec. at 220 C (maximum curing conditions)

A SHORT INTRODUCTION TO CORROSION AND ITS CONTROL

CGC1D1: Interactions in the Physical Environment Factors that Affect Climate

PREPARING HOT-DIP GALVANIZED STEEL SURFACES FOR PAINTING OR POWDER COATING: A PRIMER

Flocking of textiles. Flocked shirt 13. flocking drying cleaning. adhesive. application. creation

British standards (BS) & codes related to steel construction

Removable Insulation Blankets from A to Z

WEATHERING, EROSION, AND DEPOSITION PRACTICE TEST. Which graph best shows the relative stream velocities across the stream from A to B?

Ruukki Finnera. The most intelligent roof ever seen.

Plants, like all other living organisms have basic needs: a source of nutrition (food),

SPECIAL COMPOUND FOR RHEOPLASTIC AND ANTI-CORROSION SUPERCONCRETE WITH VERY HIGH DURABILITY

Chromadek for Roofing Applications Pre-painted hot-dip galvanised steel sheet

Transcription:

Advisory Note GEN 12/2 Atmospheric Corrosion Resistance of Hot Dip Galvanized Coatings April 2012 Scope This note is intended to provide guidance on the Life to First Maintenance (LFM) of hot dip galvanized steel articles manufactured to AS/NZS 4680 i in a range of atmosphere exposure conditions. LFM estimates are taken from ISO 9223 ii and ISO 14713 iii corrosion rates. Corrosion resistance of galvanized steel in contact with other metals (bimetallic corrosion), chemicals, soil, fresh water or salt water requires special consideration and you are advised to contact the GAA or other experts for advice on these subjects. General No commercial coating for protecting steel has proven to be more serviceable and of such predictable performance in the Australian atmosphere than hot dip galvanizing. Its good performance is due to its inherent corrosion control, high resistance to mechanical damage and its inertness to the high to extreme UV levels prevailing over most of the Australian continent. Unprotected steel will normally corrode 10 to 40 times faster than hot dip galvanized articles; the higher ratios usually being in high-chloride environments. Hot dip galvanized articles provide significant advantages to the specifier by reducing life-cycle costs, the environmental burden and increasing amenity. Zinc is a naturally occurring element, is essential for life and is 100% recyclable. The LFM of any particular hot dip galvanized article is the time interval that elapses after the steel is initially coated and before the galvanizing deteriorates to the point when maintenance is necessary to restore protection of the steel base. LFM is a function of both the thickness of the zinc alloy coating and the nature of the environment. This is shown in Chart 1. LFM for any environment is directly proportional to the thickness of the galvanized coating, which is normally a function of the thickness of the steel. In addition, the corrosivity of particular environments have been widely researched and the corrosion rates of both steel and zinc are classified in International and Australian standards as a function of the time the surface is wet, the amount of airborne salinity and the amount of airborne pollution present. These are divided into six general categories or zones by ISO 9223, AS 4312 iv and AS/NZS 2312 v, as shown in Table 1 and Table 2 (see also Corrosivity Zones on page 4). In addition to Chart 1 (Life to First Maintenance) the following aspects of the serviceability of galvanized coatings should be taken into account: Page 1 of 9

Predictability of Service Life of Hot Dip Galvanizing Extensive studies vi have established that, over the long term, the service life of any hot dip galvanized structure is essentially proportional to the thickness of the hot dip galvanizing coating for any particular atmospheric environment. The corrosivity of that environment can be assessed from short-term durability data, typically taken over 1-2 year periods. Table 2 shows the comparative corrosivity rate of various environments of carbon steel and zinc for the first year of service. Time of Wetness (temperature-humidity complex) Time of wetness is the length of time during which the metal surface is covered by a film of water which renders atmospheric corrosion possible. It is influenced by factors such as the article mass, orientation of the article and the amount of pollution in the atmosphere. ISO 9223 defines this period as the number of hours per year that the relative humidity is above 80% for temperatures above 0 C. Temperature by itself influences corrosion rate but can have contradictory effects; increasing temperature accelerates the rate of the corrosion reactions, but, on the other hand, leads to more rapid evaporation, thus shortening the time of wetness and decreasing the corrosion rate. Airborne Salinity Airborne salinity is a powerful stimulant for atmospheric corrosion and the deposition rate of salt in nonsheltered situations is directly proportional to the concentration of salt in the atmosphere. Airborne salt has a major influence on corrosion rates. The airborne salinity is strongly dependent on the variables influencing the transport inland of sea-salt, such as wind direction, wind velocity, local topography, distance of the exposure site from the sea, etc. Rainfall also influences corrosion rates and has the effect of either stimulating or reducing corrosion, depending on the environment. In coastal atmospheres, the washing effect of rain reduces corrosion, while at those locations well away from the ocean the situation is reversed and the corrosive action of rain is more significant. Impact of Industrial Pollution The influence of industrial pollution in Australia (commonly measured as the amount of SO 2 emissions) on the service life of galvanizing is very low vii. This is due in part to the environmental pollution constraints introduced from the early 1970's, notably regarding the reduction of SO 2 emissions. In all cities around Australia, the macro-environment for industrial pollution is now not considered an important influence on corrosion rates. Micro-environments Corrosion rates may increase significantly above the values shown in Chart 1 due to quite localised microenvironments (the conditions prevailing around the structure), such as severe coastal locations where the surface is exposed to high levels of airborne salinity, but not subjected to the cleansing influence of rainwater and has a lack of good ventilation and drying. Every effort should be made to identify the prevailing conditions around the location of the article to be galvanized prior to finalising the design. This will strongly influence the decision on the type of protection required. For example, the underside of a bridge, which is stretched over a body of water, will have a microenvironment that is likely to differ from the general environment of the bridge. Page 2 of 9

Inside buildings with a normal dry environment, there is likely to be little or no need for corrosion protection (except where aesthetics are concerned), especially if the relative humidity is less than 60%. On the perimeter of buildings the design will often influence the need for corrosion protection; if the steel work is in direct contact with the outer wall or façade then corrosion protection will most likely be required. Where the steelwork is partially sheltered (such as inside sheds with large openings and under the eaves of domestic buildings), it is recommended the specifier assume these are considered as part of the external environment. Another example of this is in the design of lintels for domestic buildings using masonry construction, where hot dip galvanized sections are specified by the Building Code viii. In some instances, where the micro-environment is significantly more severe than for the rest of the structure, the area may best be provided with a Duplex ix coat to provide additional protection in the areas subject to the micro-environment. Buildings containing industrial processes, chemical environments, wet or contaminated environments should be given special consideration and will require expert advice for the structure to obtain the design life. In some cases, alternative materials should be considered. Slunder & Boyd and Porter x also provide general guidance on particular chemical pollutants. Other Environments Affecting the Durability of Hot Dip Galvanized Coatings This Advisory Note provides general advice on the protection of steel provided by galvanizing in most macroscopic and microscopic environmental conditions. There are a number of other environments experienced by galvanized articles and Appendix H of AS/NZS 4680 provides advice on some of the other environments which need to be considered in the design and specification process. Other environments include articles buried or in long term contact with soils, immersed in or splashed by fresh or salt water, abrasion, exposure to specific chemicals, contact with concrete or wood and bimetallic corrosion. Advice on these exposures is available from the GAA or specialized corrosion consultants. Determining the Environment In general the specifier should answer the following questions from AS 4312: a) What is the nature of the general or macro environment? b) Are there local environments or micro-environments which will operate? c) Is the environment likely to change? d) Should only the worst environment be considered or should the project be divided up into different environmental zones? AS 4312 provides good advice on determining the likely corrosivity of a particular environment and in addition provides maps of areas of Australia to assist in general determinations. Page 3 of 9

Corrosivity Zones At the time of writing, ISO 9223:2011 and ISO 14713:2009 had been revised to include a new zone CX (Extreme). This has been introduced to cover specific industrial and industrial marine locations not previously included in the Standards. The updated standards also allow for the effects of tropical zones not previously covered, although AS 4312 and AS/NZS 2312 recognised these zones through the addition of the tropical zone to allow for the decreased life of standard paints in high UV areas. Hot dip galvanizing is not affected by the UV of the tropics and has, for a long period, been successfully used in these areas. For some guidance on classifying the climate and the corrosivity zone the hot dip galvanized steel will be exposed to, please refer to the map below (obtained from www.bom.com.au) as well as Table 1. AS/NZS 2312 and AS 4312 are still usable without this new zone included in their text, although specifiers will need to follow the advice of ISO 9223 and ISO 14713 when they encounter design situations with extreme corrosivity. For this reason, the GAA has included the ISO standards in our data showing performance of hot dip galvanizing in all situations. Page 4 of 9

Maintenance Galvanizing protects the base steel until the zinc has largely corroded away, so the article may be left unmaintained if the corrosion rate of the coating is insufficient to affect the performance of the article in its designed period of use. If a longer life span is required, maintenance of the coating should be carried out by stripping and regalvanizing (part of) the structure or by painting while some original coating remains. AS/NZS 2312 recommends that maintenance painting can be deferred until about 2% of the article exhibits "red rusting". In contrast, for conventionally painted steel, maintenance painting should not be deferred beyond an area of 0.2-0.5% "red rusting", as corrosion of the steel can progress unobserved under a paint film. Costs of ultimate maintenance painting to extend galvanizing life are normally lower than for reinstating painted steel, because the residual galvanizing is strongly adherent and readily abrasively blasted back to a sound substrate. Page 5 of 9

Table 1: Corrosion Categories and Typical Environments Corrosivity category Corrosivity Typical environments Examples from ISO 9223 Indoor Outdoor C1 Very low Heated spaces with low relative humidity and insignificant pollution, e.g. offices, schools, museums C2 Low Unheated spaces with varying temperature and relative humidity. Low frequency of condensation and low pollution, e.g. storage, sport halls C3 Medium Spaces with moderate frequency of condensation and moderate pollution from production process, e.g. food-processing plants, laundries, breweries, dairies C4 High Spaces with high frequency of condensation and high pollution from production process, e.g. industrial processing plants, swimming pools C5 Very high Spaces with very high frequency of condensation and/or with high pollution from production process, e.g. mines, caverns for industrial purposes, unventilated sheds in subtropical and tropical zones Dry or cold zone, atmospheric environment with very low pollution and time of wetness, e.g. certain deserts, Central Arctic/Antarctica Temperate zone, atmospheric environment with low pollution (SO 2 < 5 μg/m 3 ), e.g. rural areas, small towns Dry or cold zone, atmospheric environment with short time of wetness, e.g. deserts, subarctic areas Temperate zone, atmospheric environment with medium pollution (SO 2: 5 μg/m 3 to 30 μg/m 3 ) or some effect of chlorides, e.g. urban areas, coastal areas with low deposition of chlorides Subtropical and tropical zone, atmosphere with low pollution Temperate zone, atmospheric environment with high pollution (SO 2: 30 μg/m 3 to 90 μg/m 3 ) or substantial effect of chlorides, e.g. polluted urban areas, industrial areas, coastal areas without spray of salt water or, exposure to strong effect of de-icing salts Subtropical and tropical zone, atmosphere with medium pollution Temperate and subtropical zone, atmospheric environment with very high pollution (SO 2: 90 μg/m 3 to 250 μg/m 3 ) and/or significant effect of chlorides, e.g. industrial areas, coastal areas, sheltered positions on coastline CX Extreme Spaces with almost permanent condensation or extensive periods of exposure to extreme humidity effects and/or with high pollution from production process, e.g. unventilated sheds in humid tropical zones with penetration of outdoor pollution including airborne chlorides and corrosion-stimulating particulate matter Subtropical and tropical zone (very high time of wetness), atmospheric environment with very high SO 2 pollution (higher than 250 μg/m 3 ) including accompanying and production factors and/or strong effect of chlorides, e.g. extreme industrial areas, coastal and offshore areas, occasional contact with salt spray Deposition of chlorides in coastal areas is strongly dependent on the variables influencing the transport inland of sea salt, such as wind direction, wind velocity, local topography, wind sheltering islands outside the coast, distance of the site from the sea, etc. Extreme effect by chlorides, which is typical of marine splash or heavy salt spray, is outside of the scope of this Chart. Corrosivity classification of specific service atmospheres, e.g. in chemical industries, is outside of the scope of this Chart. Surfaces that are not sheltered or rainwashed in marine atmospheric environments where chlorides are deposited can experience a higher corrosivity category due to the presence of hygroscopic salts. In environments with expected CX category, it is recommended that the atmospheric corrosivity classification from one-year corrosion losses be determined. One-year exposure tests should start in the spring or autumn. In climates with marked seasonal differences, a starting time in the most aggressive period is recommended. The concentration of sulfur dioxide (SO 2) should be determined during at least one year and is expressed as the annual average. However, in Australia, SO 2 is so low in most environments that it is generally considered that It can be ignored, other than for specific industrial applications or extreme traffic examples. Coastal areas are normally defined as between 50 metres to 1 Km inland from sheltered seas and between 1 Km and 10-50 Km from surf beaches depending upon prevailing winds and topography. More details and examples are available in AS 4312. The Australian Bureau of Meteorology provides weather charts for Australia at http://www.bom.gov.au/climate/. These show average and recent conditions, including rainfall, temperature, humidity, evaporation, wind and UV. Page 6 of 9

Table 2: Corrosion rates for steel and zinc for the first year of exposure for the different corrosivity categories This table has been developed from Table 2 of ISO 9223. Corrosivity category Comparative corrosion rates for steel and zinc from ISO 9223 r corr Unit Carbon steel Zinc C1 g/(m 2 a) r corr 10 r corr 0.7 µm/a r corr 1.3 r corr 0.1 C2 g/(m 2 a) 10 < r corr 200 0.7 < r corr 5 µm/a 1.3 < r corr 25 0.1 < r corr 0.7 C3 g/(m 2 a) 200 < r corr 400 5 < r corr 15 µm/a 25 < r corr 50 0.7 < r corr 2.1 C4 g/(m 2 a) 400 < r corr 650 15 < r corr 30 µm/a 50 < r corr 80 2.1 < r corr 4.2 C5 g/(m 2 a) 650 < r corr 1,500 30 < r corr 60 µm/a 80 < r corr 200 4.2 < r corr 8.4 CX g/(m 2 a) 1,500 < r corr 5,500 60 < r corr 180 µm/a 200 < r corr 700 8.4 < r corr 25 The classification criterion is based on the methods of determination of corrosion rates of standard specimens for the evaluation of corrosivity (see ISO 9226 xi ). The corrosion rates, expressed in grams per square metre per year [g/(m 2 a)], are recalculated in micrometres per year (μm/a) and rounded. Corrosion rates in category CX are considered extreme. Corrosivity category CX refers to specific marine and marine/industrial environments. Specific calculation models, guiding corrosion values and additional information on longterm corrosion behaviour, are given in ISO 9224 xii. Page 7 of 9

Chart 1: Life to First Maintenance of Hot Dip Galvanized Steel The LFM range for a particular hot dip galvanizing coating thickness and each corrosivity zone can be read from the chart. For example, the LFM range for a hot dip galvanized article with an 85 µm thickness and located in the C4 (High) corrosivity zone is 20 to 40 years. This chart is supported by case history evidence in Australia, where service life records of 50 years are common and up to 110 years are recorded. The Life to First Maintenance chart is available as a standalone document directly from the Galvanizers Association of Australia. Page 8 of 9

Summary The atmospheric corrosion rate of hot dip galvanized articles is predictable and offers considerable benefits to the specifier over uncoated steels. In many cases, it is essential to provide corrosion protection for the steel in order to meet the design life of a structure and in most cases hot dip galvanizing provides an economical and attractive solution. A designer must take into account the location of the finished article, which requires a consideration of the general or macro-environment, the specific or micro-environments around the location as well as an understanding as to whether the environment will change over time. Hot dip galvanized articles have performed successfully in the Australian environment for many years and their durability is well understood. Numerous articles have performed for over 50 years, with documented cases of products lasting over 100 years. i AS/NZS 4680:2006, Hot-dip galvanized (zinc) coatings on fabricated ferrous articles ii ISO 9223 Corrosion of metals and alloys -- Corrosivity of atmospheres -- Classification, determination and estimation (ISO 9223:2011) iii ISO 14713-1, Zinc coatings Guidelines and recommendations for the protection against corrosion of iron and steel in structures Part 1: General principles of design and corrosion resistance (ISO 14713-1:2009) iv AS 4312-2008 Atmospheric corrosivity zones in Australia v AS/NZS 2312:2002 Guide to the protection of structural steel against atmospheric corrosion by the use of protective coatings vi CJ Slunder and WK Boyd, Zinc: Its Corrosion Resistance Int. Lead Zinc Res. Org. In. Aug. 1983 vii Department of Sustainability, Environment, Water, Population and Communities, State of the Air in Australia 1999 2008, Commonwealth of Australia, 2010 viii National Construction Code, Volume 2, Building Code of Australia 2011 Class One and Class Ten Buildings, Section 3.3.3.5 Corrosion Protection, Australian Building Codes Board, 2011 ix Galvanizers Association of Australia Guide to Adopting Paint Systems for Galvanized Steel, 2007 x Porter F. Zinc Handbook, Properties, Processing and Use in Design, Marcel Dekker Inc. Y 1991 xi ISO 9226 Corrosion of metals and alloys Corrosivity of atmospheres Determination of corrosion rate of standard specimens for the evaluation of corrosivity (ISO 9226:2011) xii ISO 9224 Corrosion of metals and alloys Corrosivity of atmospheres Guiding values for the corrosivity categories (ISO 9224:2011) Page 9 of 9