When will you offer customers the functionality to manage their electricity consumption?

Similar documents
Everything you should know about smart meters

New Hampshire Electric Cooperative s Smart Grid Project Frequently Asked Questions (FAQ)

Smart Metering and RF Mesh Networks for Communities

Automated Meter Reading Frequently Asked Questions. What is AMR?

Network Communications System. Redefining Intelligent Utility Communications

Convergence of Advanced Information and Control Technology in Advanced Metering Infrastructure (AMI) Solution

FUNCTIONAL SPECIFICATION FOR AN ADVANCED METERING INFRASTRUCTURE VERSION 2

Smart Meter Deployment and Customer Opt-Out. Paul Gastineau Senior Director of Rates & Regulatory Research

Application Note AN-00125

Mobile use, radio signals and health

Frequently Asked Questions about AMI (Advanced Metering Infrastructure) Meters

What is DECT? DECT stands for Digital Enhanced Cordless Telecommunications.

COMMON REGULATORY OBJECTIVES FOR WIRELESS LOCAL AREA NETWORK (WLAN) EQUIPMENT PART 2 SPECIFIC ASPECTS OF WLAN EQUIPMENT

RF Safety Compliance and Duty Cycle for OpenWay CENTRON 4G-LTE Meters December 2015

Technologies Supporting Smart Meter Networks

AMI and DA Convergence: Benefits of Growing Your Smart Grid Infrastructure with a Multi Technology Approach

ZigBee Propagation for Smart Metering Networks

Wireless Network Standard and Guidelines

OpenWay Radio Frequency FAQ

How does a multi-purpose. network compare to load. management alternatives?

Wireless data communication in Control Systems

HomeReACT a Tool for Real-time Indoor Environmental Monitoring

How To Know If You Are Safe To Use An Antenna (Wired) Or Wireless (Wireless)

ICT Policy. Executive Summary. Date of ratification Executive Team Committee 22nd October Document Author(s) Collette McQueen

AMI security considerations

Background. Industry: Challenges: Solution: Benefits: APV SERIES CASE STUDY YJFX, Inc.

DMS - Breakthrough Technology for the Smart Grid

& benefits. Indian context

Cable TV Headend Solutions

Universal Wideband Edge QAM Solution. A New Way to Manage the Edge and Future-Proof Your Network

FIBRE TO THE BTS IMPROVING NETWORK FLEXIBILITY & ENERGY EFFICIENCY

Privacy Policy Version 1.0, 1 st of May 2016

ComEd Improves Reliability and Efficiency with a Single Network for Multiple Smart Grid Services

Product Safety and RF Exposure for Mobile Two-Way Radios Installed in Vehicles or as Fixed Site Control Stations

Preparing for the HIPAA Security Rule

Questions and answers (FAQ) Reliance Protectron Go! Control security system

AV1200 TL-PA8030P KIT. 3-Port Gigabit Passthrough Powerline Starter Kit. Highlights

Key Priorities for Sub-GHz Wireless Deployment

4-Port 10/100Mbps with PoE + 1-Port 100FX Industrial Ethernet Switch Wide Temperature

HIPAA Security Alert

Contingency Planning Guide

Rack mounted telephone- and leased line modem for industrial applications

Making a complaint about UK Government services

Legislative Council Panel. on Information Technology and Broadcasting. Implementation of a Government Cloud Platform

FOR EXISTING 254-FOOT COMMUNICATIONS TOWER Skyline Drive La Habra Heights California

Radio Frequency Strategy in an AMI Deployment. Larry Eggleston Director, Product Marketing. Michael Schleich Director, Research and Development

MOBILE PHONE JAMMERS ACA Report

Security in the smart grid

For Utility Operations

Introducing Graves IT Solutions Online Backup System

WI-FI VS. BLUETOOTH TWO OUTSTANDING RADIO TECHNOLOGIES FOR DEDICATED PAYMENT APPLICATION

Are apps available for Virtual Water Assistant? No. We use a mobile website.

Smart Metering Initiative ADWEA Program

RISE OF CONSUMER RESISTANCE

Questions You May Want to Ask Your Electric Power Company about Wireless Smart Meters

CenterPoint Energy Robert B. Frazier Director of Electric Technology

DC Traction Power Supply. Powerful, efficient and safe. siemens.com/mobility

IBX Business Network Platform Information Security Controls Document Classification [Public]

The Three Pillars for an Efficient AMI Operation

Treasure Valley Electric Plan - Community Advisory Committee

An Oracle White Paper May Smart Grid Basics. Turning Information into Power

Management of IT Risks

Autodesk PLM 360 Security Whitepaper

What is ? Why are standards important?

10 Hidden IT Risks That Might Threaten Your Law Firm

Approaches to Pilots: Smart Metering, Smart Grid Oliver Iltisberger Executive Vice-President, Asia Pacific, Landis+Gyr

Chapter 3 Safeguarding Your Network

Wireless Network Standard

<cloud> Secure Hosting Services

SPECTRUM SHARING OUTLINE FOR CSMAC

Applying Mesh Networking to Wireless Lighting Control

CloudDesk - Security in the Cloud INFORMATION

SHEET 1 COMMUNICATION NETWORKS COMPUTER AND TELEPHONE SYSTEMS

Telecom Italia and WSN

Philips remote monitoring and control systems

HIPAA Security COMPLIANCE Checklist For Employers

Wireless LANs vs. Wireless WANs

Demand Response Market Overview. Glossary of Demand Response Services

UNDERSTANDING RADIO FREQUENCY AND BC HYDRO S SMART METERS

Colocation. Introduction. Structure of the service. Service Description

Architecture and Technologies for HGW

itrack OTR Tyre Monitoring Making Mines Safer & More Productive

Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters

Empowering intelligent utility networks with visibility and control

1.1.1 Introduction to Cloud Computing

Using Industrial Ethernet Switches to Assure Maximum Uptime White Paper

Managed Internet Service Express

Corporate ICT Availability

EBSA Power Distribution Application Paper

Reduce the cost of communication with ComAp. Telecom tower solutions

Application Note AN-00126

Tyco Integrated Fire & Security Monitoring Services. Helping you secure your business 24 hours a day, 365 days a year. Safer. Smarter. Tyco.

Market Growth and New Regulations Demand Network Modernization

Regulation for wireless telecommunication equipment

Enterprise Network Virus Protection Research Yanjie Zhou 1, Li Ma 2 Min Wen3

ABB PSPS Erich Steinmann; Generator control-2013

SERVICES BROCHURE info@t-r-s.com.au PO BOX 680, Claremont, 6910, Western Australia

Top 11 Concerns When Buying a VoIP Business Phone System. What You Need to Know Before You Invest

OPERATIONS CAPITAL. The Operations Capital program for the test years is divided into two categories:

Transcription:

Can next-generation meters catch fire? No. In the few cases of fire reported elsewhere, experts have demonstrated that the customer s meter socket, or base, was defective in some way. If a socket breaks when a meter is being replaced, the installer calls in a master electrician. Next-generation meters are approved by Measurement Canada and they are safe. In November 2013, the Corporation des maîtres électriciens du Québec issued a reminder of the importance of inspecting the socket regularly (in French). https://www.cmeq.org/professionnels-de-lelectricite/actualites/fiche-dactualite/la-securite-electrique-il-faut-y-voir/ Could next-generation meters be adversely affected by winter temperatures? Hydro-Québec is bound to comply with Measurement Canada standards respecting the quality of electricity meters that operate throughout the year. As part of the certification processes, the next-generation meters had to pass a test involving sudden, extreme temperature changes. The new meters are designed to withstand Québec s harsh winters. When will you offer customers the functionality to manage their electricity consumption? In 2016, customers will be able to monitor their electricity consumption in their Customer Space on the Hydro-Québec Web site and use it wisely. As the advanced metering infrastructure is rolled out, we ll carry out separate projects to study the implementation of certain functions.

Do the meters measure their own energy consumption and are customers charged for it? No, the meters don t record the amount of electricity they use. The consumption of the meter itself (metering card, communications card, etc.) is not included in the customer s consumption and is not billed to the customer. Could Hydro-Québec experience computer and telecommunication network failures? Could my billing data be lost? The computer and telecommunications system hardware is robust and reliable. Nevertheless, Hydro-Québec has incorporated a number of contingency measures or systems into the advanced metering infrastructure in order to quickly correct any fault that might occur. The new meters have an automatic backup function enabling them to save electricity consumption data while any technical problems are being fixed. The data can then be submitted once the situation has been restored. Furthermore, with the dynamic architecture we have chosen, the mesh communications network will be reconfigured automatically as necessary. What is the certification process for meters and telecommunications equipment to be used in the advanced metering infrastructure? Certification testing for meters complies with the strictest international standards and falls into three categories: electromagnetic compatibility testing, climate testing and mechanical testing. All telecommunications hardware undergoes thorough climate testing. Hydro-Québec meters meet Measurement Canada certification standards. Instead of allowing people to opt out, why didn t Hydro-Québec select remote activation and deactivation technology involving the next-generation meter s telecommunications card?

Although the technology is being studied, it s not yet on the market. That s why none of the bidders proposed it in response to our requests for proposals. Opting out means having a noncommunicating electronic meter with no radiofrequency emissions installed. This meter, already being marketed, is accredited by Measurement Canada. Hydro-Québec s opting-out program is similar to most others, which take into account by the current state of the technology. What is the frequency band of the next-generation meters? The meters emit radiofrequencies in the 902-to-928 MHz band, the same one used by baby monitors. What is the average transmission power of the routers in Hydro-Québec s advanced metering infrastructure? The theoretical values for router emissions are well below the Health Canada guidelines. Typically, the value at 4 m is approximately 70,000 times lower than the exposure limits, and at 1 m, it is approximately 4,000 times lower. The routers are therefore perfectly safe. Keep in mind that the power density of emissions diminishes rapidly with distance. At 500 m, it is virtually impossible to measure a router s emission levels accurately, because they are more than one billion times lower than the standard in effect. At 100 m, the emission power is close to forty-three million times lower than the standard. Can the meter cause interference with my home electronics?

Any device that operates on the 902-to-928 MHz band and uses digital transmission technologies must meet Industry Canada standard CNR-210, so it must be designed to neither cause nor suffer from interference. Some older devices, however, use the older analogue technology, which is being phased out. Although they are compliant with the standard, they may, in rare circumstances, suffer from interference caused by other devices operating in the same frequency band. What do the routers and data collectors in the advanced metering infrastructure look like? Will you put one on my roof? No, the routers and data collectors used by the advanced metering infrastructure will not be installed on people s roofs without the owners prior agreement. Most of these small mobile communications devices will be installed on existing infrastructure (Hydro-Québec poles, telecommunications towers, etc.). An Evolvable Network An Evolvable Network Hydro-Québec is entering a new stage in the development of a smart grid, which, in the long term, will cut costs to customers. The company decided on an advanced metering infrastructure that requires the installation of 3.8 million next-generation meters. This new technological platform will allow billing based on actual consumption through remote reading. Customers will no longer have to fill in meter-reading cards when they move and service can be restored remotely. Watch the video to learn more. Length : 02 min. 53 sec. Close window Hydro-Québec is entering a new stage in the development of a smart grid, which, in the long term, will cut costs to customers. The company decided on an advanced metering infrastructure that requires the installation of 3.8 million next-generation meters. This new technological platform will allow billing based on actual consumption through remote reading. Customers will no longer have to fill in meter-reading cards when they move and service can be restored remotely. Watch the video to learn more. Will the selected technology eventually allowhydro-québec to offer a variety of new services? Yes. Next-generation meters installed by Hydro-Québec have a two-way communications card, so they can transmit and receive. They transmit electricity use data, but can also receive updates or be reprogrammed remotely when new functions are implemented. Before programming new functions, Hydro-Québec has to do an analysis to make sure that they will benefit customers or the company. This capability enables the selected technology to advance and to fully meet HQ s business needs as they evolve over time. In addition, any services must be approved by the Régie de l énergie [Québec energy board] in light of, for instance, the investment required and the rates affected.

What data does Hydro-Québec collect in its advanced metering infrastructure project? Why? What data does Hydro-Québec collect in its advanced metering infrastructure project? Why? Hydro-Québec only collects electricity use data for billing purposes. Customers personal information, such as name, address and telephone number, is not sent through the various components of the advanced metering infrastructure network. Hydro-Québec intends to use electricity use data from meters to improve service, especially with respect to outages. The limited data collected, combined with encryption during communication, reduces the risk that the data might be intercepted on its way between components of the AMI, that is, between the smart meters and the head-end data server. Of course, Hydro-Québec will continue to maintain all necessary security and privacy measures by following recognized industry guidelines and complying with the Act Respecting Access to Documents Held by Public Bodies and the Protection of Personal Information (CQLR, c. A-2.1). Furthermore, in February July 2013, after its inspection, the Commission d accès à l information [access to information commission] concluded that access to information [...] makes it possible to use the data collected, while at the same time protecting users personal information.