PTU300 Combined Pressure, Humidity and Temperature Transmitter for Demanding Applications

Similar documents
Vaisala Weather Transmitter WXT510 The Most Essential of Weather

How is Dew Point Measured Reliably?

WEATHER STATION FOR SOLAR FARM MONITORING

Duct Humidity Transmitter

The PACE5000 Modular Pressure Controller/Indicator

Electronic Control Devices The European Product Catalogue 2007

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Temperature & Humidity SMS Alert Controller

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

RPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control Solutions. Features:

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Integrating Digiquartz MET3 and MET3A Broadband Meteorological Systems with Leica GX1200 Series GPS Receivers

PIEZOMETER AIRFLOW MEASURING RING

USER S GUIDE. EE210 - Humidity and Temperature Transmitter for demanding Climate Control Applications GENERAL CAUTION CONNECTION DIAGRAM

USER'S GUIDE. Vaisala HUMICAP Humidity Transmitter Series HMP140A U175EN15

Test equipment for temperature and its reduction

Temperature Alert. LAN-based Temperature and Humidity Data Logger

Wireless Data Logger Monitoring Systems

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Hand-held thermometer Model CTH7000

KNX Panasonic Air Conditioners

How To Use A Gizmo 2.5 (Gizmo) With A Power Supply (Power Supply) And Power Supply For A Long Time (Power Source) (Power Cell) (Gigabone) (Microphone) (

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

TP32MTT.03 TP32MTT [ GB ] Probes for soil thermal profile measurement

PACE1001 Barometer Precision Barometric Indicator and Recorder

/ Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards.

Precision Pressure Indicator Model CPG2500

IntesisBox Modbus Server Fidelio IP

Typical Aluminum GFM Mass Flow Meter

Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]

How To Use A Ds340 (Dsp)

T0118 T2118 T3118. Instruction Manual

IntesisBox Modbus Server SAMSUNG Air Conditioners

Product overview mm. 100 mm

Electronic Control Devices The European Product Catalogue 2007

Material test chamber with mechanical convection

Rosemount 333 HART Tri-Loop

Rosemount 333 HART Tri-Loop

MLC TM Maximum Productivity and Versatility for Control without Compromise!

4-Channel Thermometer / Datalogger

Outages Happen 24/7 So Should Monitoring / SAFEGUARD YOUR HIGH VOLTAGE ASSETS WITH VAISALA ONLINE MONITORING

Temperature, hygrometry, CO and CO 2. probes for class 310 transmitters

Technical Note A007 Modbus Gateway Vantage Pro2 25/09/2009 Rev. A 1 de 7

Incubator with mechanical convection

Product Specifications

GeoMax GNSS Zenith10 & Zenith20 Series

Power Commander Power Distribution Units from Wiremold/Legrand offer

Relative Humidity Sensors, Transmitters and Calibration Products Relative Humidity Measurement and Calibration

SNMP Web Management. User s Manual For SNMP Web Card/Box

Long Distance Industrial Wireless Transmitters and Receivers

Recommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail. Qwik Install

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Energy Communication Unit (ECU)

Microcor Wireless Transmitter (MWT)

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected

Indoor / Outdoor Antenna

PACE1000 Precision Pressure Indicator

EE210. Humidity and Temperature Transmitter for Demanding Climate Control. Applications. Features. 4 v2.2 / Modification rights reserved EE210

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:

NETWORK ENABLED EQUIPMENT MONITOR

Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem

O C M III. Open Channel Flow Monitor

2.24. Pump Controller 704. Data Sheet

Repeaters and Mimics Data Sheet

IntesisBox KNX Modbus TCP master

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Contents Chapter 1: Introduction... 3 Chapter 2: Ethernet (LAN)... 5 Chapter 3: ZigBee Wireless Connection Options... 7

USB-500/600 Series Low-Cost Data Loggers and Accessories

Energy Communication Unit (ECU)

TrueAlarm Fire Alarm Systems

Carbon Monoxide (CO) Gas Detection and Control System

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

connecdim Gateway G1 Ethernet TCP/IP to DALI

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Pressure transmitter For general industrial applications Model A-10

Instruction Manual. T3111 T3111L T3111P T3111Ex

Frequency selective monitoring and logging of environmental electromagnetic fields

T Substation Maintenance and Commissioning Test Equipment

Buckeye Detection Systems Fixed Detection Systems Application Survey

In-Sight Hardware specifications

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

PACE Modular Pressure Controller

Room Controllers. SER8300 Line Voltage Fan Coil Room Controller with SC3000 Relay Pack

86 C Freezer Accessories. More Choices. Choose from a Wide Selection of Racks, Monitoring Systems and Other New Brunswick Freezer Accessories

UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard.

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Digital inductive conductivity transmitter

1701/22 FieldMonitor Management Interface Module

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Transcription:

www.vaisala.com PTU300 Combined Pressure, Humidity and Temperature Transmitter for Demanding Applications over four years of measured history, and zoom in on any desired time or time frame. The battery backup of the real-time clock guarantees a reliable logging of measured data. The display alarm allows tracking of any measured parameter, with a freely configurable low and high limit. The Vaisala PTU300 Combined Pressure, Humidity and Temperature Transmitter is a versatile, multi-purpose instrument. One Transmitter, Three Measurements The Vaisala Combined Pressure, Humidity and Temperature Features/Benefits Barometric pressure, humidity and temperature measurement in one transmitter Available with two barometric pressure sensors added reliability RS-232C serial interface with NMEA protocol for GPS use Optional display, RS-485, analog output, and relay Optional power supply module NIST traceable calibration HMT330MIK Installation kit for outdoor use Applications include environmental monitoring in calibration laboratories, GPS meteorology: estimating precipitable water vapor in the atmosphere; weather stations Modbus protocol support (RTU/TCP) Transmitter PTU300 measures barometric pressure in two accuracy classes, humidity, and temperature. You can choose which probe best suits your needs: PTU301 for laboratories, PTU303 for outdoor use, the warmed PTU307 probe for demanding meteorology, and PTU30T for pressure and temperature only. Vaisala Proven Sensor Technology The PTU300 transmitter uses sensors known for their high accuracy and excellent long-term stability: the Vaisala BAROCAP is used for pressure measurement and the Vaisala HUMICAP for humidity measurement. The temperature sensor is a platinum RTD sensor. Graphical Trend Display The PTU300 series features a large numerical and graphical display, allowing users to easily monitor operational data, measurement trends and 1-year measurement history. The optional data logger with real-time clock makes it possible to generate Data Collection and (Wireless) Transfer to PC The recorded measurement data can be viewed on the display or transferred to a PC with Microsoft Windows software. The transmitter can also be connected to a network with an optional (W)LAN interface, which enables a (wireless) Ethernet connection. A USB-RJ45 cable makes it easy to connect the service port of the PTU300 to a PC. PTU300 is also capable in applying the MODBUS communication protocol and together with an appropriate connection option provides either MODBUS RTU (RS485) or MODBUS TCP/IP (Ethernet) communication. Flexible Calibration A quick, one-point field calibration for humidity can easily be done using the Vaisala Hand-Held Humidity Meter HM70. Serial Communication The PTU300 comes with a standard RS-232 serial interface. The output format is compatible with major GPS receivers and NMEA coded messages. RS-485 is available as an option. Outdoor Installation Kit The optional HMT330MIK Installation Kit is available for outdoor installation. It provides reliable measurements for meteorological purposes.

PTU300 Models 120 (4.72) PTU301 for wall mounting 12 (0.47) 183 (7.20) PTU301 short cable probe 106 (4.17) Ø 12 (0.47) M9x1 116 (4.57) 42 (1.65) 37.5 (1.48) PTU303 for outdoor use 78.5 (3.09) 98.5 (3.88)

PTU300 Models Ø 12 (0.47) M9x1 37.5 (1.48) PTU307 warmed probe for demanding meteorological installations 79.5 (3.13) 99.5 (3.92) Ø 6 (0.24) Ø 3.2 (0.13) 130 (5.12) Ø 6 (0.24) Ø 3.2 (0.13) 130 (5.12) PTU30T for pressure and temperature only measurement

Technical Data Performance Barometric pressure Pressure range 500... 1100 hpa, 50... 1100 hpa Accuracy 500... 1100 hpa 500... 1100 hpa 50... 1100 hpa Class A Class B Linearity ±0.05 hpa ±0.10 hpa ±0.20 hpa Hysteresis* ±0.03 hpa ±0.03 hpa ±0.08 hpa Repeatability* ±0.03 hpa ±0.03 hpa ±0.08 hpa Calibration ±0.07 hpa ±0.15 hpa ±0.20 hpa uncertainty** Accuracy at +20 C*** ±0.10 hpa ±0.20 hpa ±0.30 hpa Temperature ±0.1 hpa ±0.1 hpa ±0.3 hpa dependence**** Total accuracy ±0.15 hpa ±0.25 hpa ±0.45 hpa (-40... +60 C/ -40... +140 F) Long-term stability/year ±0.1 hpa ±0.1 hpa ±0.2 hpa Response time (100 % response) one sensor 2 s 1 s 1 s Pressure units hpa, mbar, kpa, Pa, inhg, mmh20, mmhg, torr, psia * Defined as ±2 standard deviation limits of endpoint non-linearity, hysteresis error or repeatability error and calibration. ** Defined as ±2 standard deviation limits of accuracy of the working standard including traceability to NIST. *** Defined as the root sum of the squares (RSS) of endpoint non-linearity, hysteresis error, repeatability error and calibration uncertainty at room temperature. **** Defined as ±2 standard deviation limits of temperature dependence over the operating temperature range. Relative humidity Measurement range 0... 100 % RH Accuracy (including non-linearity, hysteresis, and repeatability at +15... +25 C ±1 %RH (0... 90 % RH) ±1.7 %RH (90... 100 %RH) at -20... +40 C ±(1.0 + 0.008 x reading) %RH at -40... +60 C ±(1.5 + 0.015 x reading) %RH Factory calibration uncertainty (+20 C ) (Defined as ±2 standard deviation ± 0.6 % RH (0... 40 %RH) limits. Small variations possible, ± 1.0 % RH (40... 97 %RH) see also calibration certificate.) Sensor for typical applications Vaisala HUMICAP 180 or 180R* for applications with chemical purge/warmed probe Vaisala HUMICAP 180C or 180RC* Response time (90 %) at +20 C (+68 F) in still air with grid filter 8 s / 17 s* with grid + steel netting filter 20 s / 50 s* with sintered filter 40 s / 60 s* * with HUMICAP 180R or 180RC sensor Temperature Measurement range, all probes -40... +60 C (-40... +140 F) Accuracy at +20 C (+68 F) ± 0.2 C (± 0.4 F) Temperature units C, F The display also shows the WMO pressure trend P 3h and tendency of 0... 9. Accuracy over temperature range Δ C 0.5 0.4 0.3 0.2 0.1 0 C -0.1-0.2-0.3-0.4-0.5-40 -20 0 20 40 60 Temperature sensor Pt100 RTD Class F0.1 IEC 60751 Operating Environment Operating temperature -40... +60 C (-40... +140 F) with display 0... +60 C (+32... +140 F) Humidity range non-condensing Electromagnetic compatibility EN61326-1:1997 + Am1:1998 +Am2:2001; Industrial Environment Inputs and Outputs Operating voltage 10... 35 VDC, 24 VAC with optional power supply module 100... 240 VAC, 50/60 Hz Power consumption at +20 C (U in 24 VDC) RS-232 max. 28 ma U out 3 x 0... 1 V/0... 5 V/0... 10 V max. 33 ma I out 3 x 0... 20 ma max. 63 ma display and backlight +20 ma during chemical purge max. +110 ma during probe heating +120 ma Settling time at power-up (one sensor) class A 4 s class B 3 s External loads current outputs R L < 500 ohm 0... 1 V output R L > 2 kohm 0... 5 V and 0... 10 V outputs R L > 10 kohm

Ø 7 (0.28) Recommended wire size 0.5 mm 2 (AWG 20) stranded wires Digital outputs RS-232, RS-485 (optional) ASCII commands, MODBUS RTU Service connection RS-232, USB Relay outputs (optional) 0.5 A, 250 VAC Ethernet interface (optional) Supported standards 10BASE-T, 100BASE-TX Connector 8P8C (RJ45) IPv4 address assignment DHCP (automatic), static Telnet, MODBUS TCP/IP WLAN interface (optional) Supported standards 802.11b Antenna connector type RP-SMA IPv4 address assignment DHCP (automatic), static Telnet, MODBUS TCP/IP Security WEP 64/128,WPA2 Authentication / Encryption (WLAN) Open / no encryption Open / WEP WPA Pre shared key / TKIP WPA Pre shared key / CCMP (a.k.a. WPA2) Optional data logger with real-time clock Logged parameters max. four with trend/min/max values Logging interval 10 sec (fixed) Max. logging period 4 years 5 months Logged points 13.7 million points per parameter Battery lifetime min. 5 years Display LCD with backlight, graphic trend display of any parameter Menu languages English, Finnish, French, German, Japanese, Chinese, Spanish, Swedish, Russian Analog outputs (optional) current output 0... 20 ma, 4... 20 ma voltage output 0... 1 V, 0... 5 V, 0... 10 V Humidity and temperature accuracy at +20 C ±0.05% full scale temperature dependence ±0.005%/ C full scale Pressure 500... 1100 hpa 50... 1100 hpa accuracy at +20 C ±0.30 hpa ±0.40 hpa accuracy at -40... +60 C ±0.60 hpa ±0.75 hpa Mechanics Cable bushing M20 x 1.5 for cable diameter 8... 11 mm/0.31... 0.43" Conduit fitting 1/2" NPT User cable connector (optional) M12 series 8-pin (male) option 1 female plug with 5 m (16.4 ft) black cable option 2 female plug with screw terminals Probe cable diameter PTU303 6.0 mm other probes 5.5 mm Housing material G-AlSi 10 Mg (DIN 1725) Housing classification IP 65 (NEMA 4) Weight depending on selected probe 1.5... 2.0 Kg Accessories PC software and cable 215005 USB-RJ45 Serial Connection Cable 219685 Connection cable for HM70 211339 Wall mounting plate (plastic) 214829 Pole installation kit 215108 Rain shield 215109 DIN rail installation set 211477 Duct installation kit, PTU303/307 210697 Cable gland and AGRO, PTU303/307 HMP247CG Solar radiation shield, PTU303/307/30T DTR502B Meteorological installation kit HMT330MIK Duct installation kit (T probe) 215003 116 (4.57) 183 (7.20) 169 (6.65) 71 (2.80) 77 (3.03) 96 (3.78) BAROCAP and HUMICAP are registered trademarks of Vaisala. TYPE APPROVED PRODUCT CERTIFICATE NO.: A-11440 www.vaisala.com Please contact us at www.vaisala.com/requestinfo Scan the code for more information Ref. B210954EN-D Vaisala 2012 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications technical included are subject to change without notice.