PS100 and CH100 Power Supply and Charging Regulators, A100 Null Modem Adapter, and A105 Additional 12 V Terminals Adapter Revision: 4/09

Similar documents
CM300 Series Mounting Poles 1/08

INSTRUCTION MANUAL. MCR1 Memory Card Reader 5/93. Copyright (c) 1993 Campbell Scientific, Inc.

LLAC4 Four-Channel, Low-Level AC Conversion Module Revision: 3/12

CM375 Portable 10-Meter Mast Revision: 8/10

CURS Ohm Current Shunt Terminal Input Module Revision: 5/07

App. Note Code: 2RA-K APPLICATION NOTE. CM225, CM255, CM255LS Pyranometer Mounting Brackets 4/15. Copyright 2015 Campbell Scientific, Inc.

RTMC WebServer Revision: 8/10

CURS Ohm Current Shunt Terminal Input Module Revision: 7/13

CSI Software Development Kit Beginner s Guide Revision: 8/06

INSTRUCTION MANUAL. SVP100 Surge Voltage Protector 9/15. Copyright 2015 Campbell Scientific, Inc.

Model 109SS Temperature Probe Revision: 12/10

PakBus Networking Guide Revision: 10/08

INSTRUCTION MANUAL. COM210 Telephone Modem. Revision: 10/05. Copyright (c) Campbell Scientific, Inc.

INSTRUCTION MANUAL. LoggerNet for Linux Installation Guide Revision: 4/15. Copyright Campbell Scientific, Inc.

LoggerLink Mobile App for Android Revision: 3/14

CSI Web Server for Linux Installation Guide 8/13

INSTRUCTION MANUAL. NL120 Ethernet Module Revision: 3/14. Copyright Campbell Scientific, Inc.

INSTRUCTION MANUAL. CSI Web Server for Linux Installation Guide Revision: 2/15. Copyright Campbell Scientific, Inc.

INSTRUCTION MANUAL. Campbell Scientific Software Development Kit Beginner s Guide Revision: 9/15. Copyright Campbell Scientific, Inc.

APPLICATION NOTE. EKO MS-710 and MS-712 Broadband Infrared Spectroradiometers (WISER Series) with CR3000 Datalogger 4/14. App.

CS100 Barometric Pressure Sensor Revision: 8/12

BroadBand PowerShield. User Manual

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

SBP270 BAROMETRIC PRESSURE SENSOR INSTRUCTION MANUAL

INSTRUCTION MANUAL. DCP-NextG Digital Cell Phone Kit Maxon ModMax MM-6280IND Revision: Dec 2012


Installation and Operation Guide for PD4100 Series Power Control Centers

Global Water Instrumentation, Inc.

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

Installation and Operation Guide for PD5100 Automatic Transfer Switch

INSTRUCTION MANUAL. NL120 Ethernet Module Revision: 4/15. Copyright Campbell Scientific, Inc.

Installation and Operation Guide PD4600 Series Converter Replacement

INSTALLATION. Omega 8000 Series Controller For Use With Omega 90 Siren/P.A. Amplifier

LoggerLink Mobile App for ios

USER MANUAL. Model U ForeFront Alarm Card SALES OFFICE (301) TECHNICAL SUPPORT (301) An ISO-9001 Certified Company

Manual. Solar Fountain Mobile Phone Charger

3 WATT LED SPOTLIGHT Model No. SLM

User Manual (English)

Powerware Relay-Serial Card User s Guide

READ FIRST! Universal Car/Air Adapter User Manual

WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL

DCX300 - DCX400 - DCX600

XC120 XC180. Owner's Guide Conforms to / Conforme à UL std. 458, Toll Free

PagePac PAGEPAL V

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

PowerStar Mini Triple Play TM

Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI

User Manual. English. APC Smart-UPS SC. 1000/1500 VA 110/120/230 Vac. 2U Tower/Rack-Mount Uninterruptible Power Supply

User Manual for CH-PFC76810

BACnet Automation Interface Module (Network Version)

UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

Triple Expansion Chassis

Single Station Remote Alarm

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

LESTRONIC DV AUTOMATIC 12 OR 24 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL TYPE 12/24EL40-10ET

Installation and Operation Guide for PD4000 Series Power Control Center

Amplified High Speed Fiber Photodetectors

Geocontrol PRO INSTALLATION AND OPERATION MANUAL. Rev. 1 03/18/04 Part #

Installation Guide Smart-UPS X External Battery Pack SMX120BP

MS900AC-B-LS User Information

AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER

Instructions & Safety Information Models A220-20D and A220-20L Version 2

User Manual. English. APC Smart-UPS 500 VA 100 VAC 750 VA 100/120/230 VAC. Tower Uninterruptible Power Supply

Leak Detection System

WristPC. WristPC Wearable Keyboard QWERTZ Special (Version 2.0L and above) Copyright L3 Systems, Inc. Redmond, WA

Zebra RW 420 Mobile Battery Eliminator Kits

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN A

TTL to RS232 Adapter User Guide

How To Install A Power Supply (Uplast) With A Battery Pack

Model SPDT Relays

How To Use A Cdm250 Digital Multimeter

i410/i1010 AC/DC Current Clamp

Alarm Clock USER GUIDE

Solar Controller / Battery Charger User s Manual

Mini Power Bank and Charger

Installation Instructions

Signal Manager Installation and Operation Manual

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

Dolphin 9900 Mobile Computers

Advantium 2 Plus Alarm

MACTek Corporation. USB HART Interface. Users Manual

16/32 Channel 1U Rack Mount CCTV Power Supply

Dual-Cool Notebook Cooler Pad. User s Manual

Mini-HDMI Series MINIATURE MULTIMODE FIBER OPTIC HDMI TRANSMISSION SYSTEM

USER MANUAL. CS106 Barometric Pressure Sensor. Issued:

Model HPX10 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Optical Wireless Mouse. User s Manual

PEDAL POWER. User s Manual

INSTRUCTION MANUAL T1 TO RS422 INTERFACE

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

USB Port Hub with USB Power Cable. User s Manual

Installation/Operator Manual For use with WFCO ULTRA III Power Center Model WF-8712P and WF-8725P

XTEND 900 MHZ WIRELESS MODEM For use with VEEDER-ROOT EMR³ DATALINK INSTALLATION INSTRUCTIONS Manual , Rev. B

13 Watt PORTABLE SOLAR POWER KIT

User Manual. English. APC Smart-UPS 1000/1500 VA 100/120/230 VAC 750/1000XL VA 120/230 VAC. Tower Uninterruptible Power Supply

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Transcription:

PS100 and CH100 Power Supply and Charging Regulators, A100 Null Modem Adapter, and A105 Additional 12 V Terminals Adapter Revision: 4/09 Copyright 2000-2009 Campbell Scientific, Inc.

Warranty and Assistance The PS100 AND CH100 POWER SUPPLY AND CHARGING REGULATORS, A100 NULL MODEM ADAPTER, AND A105 ADDITIONAL 12 V TERMINALS ADAPTER are warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in materials and workmanship under normal use and service for twelve (12) months from date of shipment unless specified otherwise. Batteries have no warranty. CAMPBELL SCIENTIFIC, INC.'s obligation under this warranty is limited to repairing or replacing (at CAMPBELL SCIENTIFIC, INC.'s option) defective products. The customer shall assume all costs of removing, reinstalling, and shipping defective products to CAMPBELL SCIENTIFIC, INC. CAMPBELL SCIENTIFIC, INC. will return such products by surface carrier prepaid. This warranty shall not apply to any CAMPBELL SCIENTIFIC, INC. products which have been subjected to modification, misuse, neglect, accidents of nature, or shipping damage. This warranty is in lieu of all other warranties, expressed or implied, including warranties of merchantability or fitness for a particular purpose. CAMPBELL SCIENTIFIC, INC. is not liable for special, indirect, incidental, or consequential damages. Products may not be returned without prior authorization. The following contact information is for US and International customers residing in countries served by Campbell Scientific, Inc. directly. Affiliate companies handle repairs for customers within their territories. Please visit www.campbellsci.com to determine which Campbell Scientific company serves your country. To obtain a Returned Materials Authorization (RMA), contact CAMPBELL SCIENTIFIC, INC., phone (435) 753-2342. After an applications engineer determines the nature of the problem, an RMA number will be issued. Please write this number clearly on the outside of the shipping container. CAMPBELL SCIENTIFIC's shipping address is: CAMPBELL SCIENTIFIC, INC. RMA# 815 West 1800 North Logan, Utah 84321-1784 For all returns, the customer must fill out a Declaration of Hazardous Material and Decontamination form and comply with the requirements specified in it. The form is available from our website at www.campbellsci.com/repair. A completed form must be either emailed to shanna@campbellsci.com or faxed to 435-750-9579. Campbell Scientific will not process any returns until we receive this form. If the form is not received within three days of product receipt or is incomplete, the product will be returned to the customer at the customer s expense. Campbell Scientific reserves the right to refuse service on products that were exposed to contaminants that may cause health or safety concerns for our employees. CAMPBELL SCIENTIFIC, INC. does not accept collect calls.

PS100 Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat bookmarks tab for links to specific sections. 1. General Description...1 2. Specifications...1 3. Wiring...2 4. A100 Null Modem Adapter...4 5. A105 12V Terminal Expansion Adapter...5 Figures 1. Wiring to Charger...3 2. Simplified Charging Circuit Schematic...4 3. Null Modem Connections...5 4. A105 Adapter...5 i

PS100 and CH100 Power Supply and Charging Regulators, A100 Null Modem Adapter, and A105 Additional 12 V Terminals Adapter 1. General Description The PS100 is a 12-volt power supply that includes a charging regulator and a 7 amp hour battery. The CH100 is a charging regulator that is used with a Campbell Scientific battery pack such as the BP12 or BP24 or with a usersupplied battery. Charging power is typically supplied by an AC transformer or an unregulated solar panel. The PS100 and CH100 each have one adapter connector that will allow connecting one of the following adapters. The A100 Null Modem Adapter has two 9-pin connectors that provide a null modem for use in a site, without a datalogger. The A100 connects and powers two Campbell Scientific peripherals that would normally be connected to a datalogger. These peripherals are typically modems linking different communications technologies; e.g., telephone to radio. The A105 Additional 12 V Terminals Adapter may be used to provide additional 12 V and ground terminals where the power supply is used to power several devices. NOTE To prevent people from getting burned, an ABS plastic cover [CSI #18688] sits on the heatsink of a PS100 or CH100. The cover is fastened to the heatsink via a #4-40 x.250 Pan Phillips screw [#395]. The cover must be removed to attach an A100 or A105 adapter. Some early models of the PS100 and CH100 did not include the cover and do not have a place to attach it. 2. Specifications Input Voltage (CHG terminals) Battery Connections Charging Output Voltage: Temperature Compensation Range: Charging Current Limit: 15 to 28 VDC or 18 VAC RMS Temperature compensated float charge for 12 V Battery -40 to +60ºC 1.2 Amps typical 1

PS100 and CH100 Power Supply and Charging Regulators Power Out (+12 terminals) Voltage: Unregulated 12 V from Battery Current Limited w / 3 A Thermal Fuse: > 3 A @ < 20 C 3 A @ 20 C 2.1A @ 50 C 1.8 A @ 60 C Battery Packs Operating Temperature Range: -40 to +60ºC Capacity: PS100 7 Amp hours BP12 12 Amp hours BP24 24 Amp hours WARNING These batteries are designed to be float charged. Permanent damage occurs and battery life is shortened if the battery is allowed to discharge below 10.5 volts. AC Transformer: CSI Model No. 9591 Input Voltage: 120 VAC Output Voltage: 18 VAC RMS Output Current (max): 1.2 Amps RMS Protection (automatic reset): 85 C thermal reset breaker UL Approval: UL-1950 AC Transformer: CSI Model No. 14014 Input Voltage: 90-264 VAC; 47-63 Hz Output Voltage: 18 VDC Output Current (max): 1.3 Amps UL Approved, File No.: E137895 Physical Specifications: PS100 10.5 cm tall, 19 cm long, 7 cm wide 3. Wiring An internal or external battery is connected to the charger by means of the INT (Internal) or EXT (External) connectors, as shown in Figure 1. An external battery cable is available for the charger. This cable connects another battery with the charger to provide power if the main battery is removed. The red lead connects to the positive battery terminal and the black lead connects to the negative terminal. WARNING Reversal of polarity of external battery will damage the PS100 or CH100. 2

PS100 and CH100 Power Supply and Charging Regulators It is possible to leave two batteries connected. The battery connections are diode isolated (Figure 2); however, if one of the batteries fail, it could draw all the charging current and the other battery will be discharged. CAUTION A battery must be attached for the charger to function correctly as a power supply. The leads from the transformer or solar panel are connected to the CHG terminals. Polarity does not matter; either lead can be connected to either terminal. The wires that connect power to the datalogger and/or peripherals are connected to the +12 and ground ( ) terminals. To Battery From Transformer or Solar Panel To Datalogger or Peripherals FIGURE 1. Wiring to Charger 3

PS100 and CH100 Power Supply and Charging Regulators INT BATT EXT These look identical when unplugged Charging Regulator OUT IN 3 A Thermal Fuse CHG OFF ON CHG CHG +12 +12 FIGURE 2. Simplified Charging Circuit Schematic 4. A100 Null Modem Adapter The A100 has two 9-pin CS I/O ports with a null modem between them. The ports are used to connect two 9-pin devices that would normally be connected to the CS I/O port on a Campbell datalogger. The charger supplies 12 volts and 5 volts to the appropriate pins on the connector for powering the connected devices. CAUTION This cannot be used as a null modem between two RS- 232 devices. 4

PS100 and CH100 Power Supply and Charging Regulators +5 V +12 V 1 1 6 2 2 7 7 3 3 8 8 4 4 9 9 5 5 +5 V GND HS Ring +12 V RX TX ME 1.85 A Thermal Fuse Ring RX TX ME FIGURE 3. Null Modem Connections 5. A105 12V Terminal Expansion Adapter The A105 adapter adds four 12-V terminals and four ground terminals to a CH100 or PS100 (see Figure 4). The extra terminals make it easier to wire multiple continuously powered 12-Vdc devices to the power supply. FIGURE 4. A105 Adapter 5

PS100 and CH100 Power Supply and Charging Regulators 6

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com info@campbellsci.com Campbell Scientific Africa Pty. Ltd. (CSAf) PO Box 2450 Somerset West 7129 SOUTH AFRICA www.csafrica.co.za cleroux@csafrica.co.za Campbell Scientific Australia Pty. Ltd. (CSA) PO Box 444 Thuringowa Central QLD 4812 AUSTRALIA www.campbellsci.com.au info@campbellsci.com.au Campbell Scientific do Brazil Ltda. (CSB) Rua Luisa Crapsi Orsi, 15 Butantã CEP: 005543-000 São Paulo SP BRAZIL www.campbellsci.com.br suporte@campbellsci.com.br Campbell Scientific Canada Corp. (CSC) 11564-149th Street NW Edmonton, Alberta T5M 1W7 CANADA www.campbellsci.ca dataloggers@campbellsci.ca Campbell Scientific Centro Caribe S.A. (CSCC) 300 N Cementerio, Edificio Breller Santo Domingo, Heredia 40305 COSTA RICA www.campbellsci.cc info@campbellsci.cc Campbell Scientific Ltd. (CSL) Campbell Park 80 Hathern Road Shepshed, Loughborough LE12 9GX UNITED KINGDOM www.campbellsci.co.uk sales@campbellsci.co.uk Campbell Scientific Ltd. (France) Miniparc du Verger - Bat. H 1, rue de Terre Neuve - Les Ulis 91967 COURTABOEUF CEDEX FRANCE www.campbellsci.fr info@campbellsci.fr Campbell Scientific Spain, S. L. Psg. Font 14, local 8 08013 Barcelona SPAIN www.campbellsci.es info@campbellsci.es Please visit www.campbellsci.com to obtain contact information for your local US or International representative.