Get Your Employees READY FLAME RESISTANT CLOTHING

Similar documents
FLAME RESISTANT (FR) NFPA 70E NESC OSHA ASTM F1506. CSA Z462 (Canada) Secondary Protection from Electric Flash fire hazards

FLAME-RESISTANT APPAREL ELECTRIC UTILITY GENERAL INDUSTRIES ARC FLASH PROTECTION OIL & GAS

ARC FLASH CLOTHING - Spentex NG2 by Encon

2012 NFPA 70E. Ten Most Important Changes. John A. DeDad

Myths and Facts on Complying with NFPA 70E's Clothing Requirements By Hugh Hoagland

Arc Flash Avoidance and its Application to Overhead Traveling Cranes

Industrial Flash Fire and Burn Injury Fundamentals with an Instrumented Manikin Demonstration of Protective Clothing Performance

IMPLEMENTING THE NEW ELECTRICAL SAFETY REQUIREMENTS

GEORGIA INSTITUTE OF TECHNOLOGY ENVIRONMENTAL HEALTH AND SAFETY PERSONAL PROTECTIVE EQUIPMENT

FLAME RETARDANT CLOTHING (FRC)

The Other Hazard of Electricity. Larren Elliott Ph.D. Lindsay Polic, CSP, REHS

PERSONAL PROTECTIVE EQUIPMENT (PPE)

Health, Safety, Environment and Community. Management System. Personal Protective Equipment PETROLEUM CSG HSEC MANAGEMENT SYSTEM PROCEDURE

Introduction to Arc Flash

Personal Protective Equipment Policy & Procedure Date: August, 2001 Approved by:

Additional information: -OSHA Instruction CPL 2.103, Field Inspection Reference Manual, Chapter IV, Section A -29 CFR 1910, Subpart I, Appendix B

WEEKLY SAFETY MEETING All Euramax Subsidiaries WELDING SAFETY / HOT WORK SAFETY. Safety Meeting Contents. Meeting Notice.

Rubber Insulating Products, Safety Equipment & Dielectric Testing Services

Lab PPE Guide Examples of Personal Protective Equipment

NFPA 70E Updates Affect Your Most Valuable Assets

PERSONAL PROTECTIVE EQUIPMENT FOR CALIFORNIA STATE UNIVERSITY, LOS ANGELES

BRANDON AND CLARK INC. // SCOTT W. CLARK, P.E. ELECTRICAL CONTINUING EDUCATION ARC FLASH - NFPA 70E

Analyzing Electrical Hazards in the Workplace

Understanding Arc Flash

AN UNCOMPROMISING COMMITMENT TO SAFETY

Safety and Health Policy and Procedure Manual. PERSONAL PROTECTIVE EQUIPMENT Section Table of Contents

SAFE ELECTRICAL WORK PRACTICES & 2015 NFPA 70E

INTRODUCTION ARC FLASH PROTECTION AND SAFETY MEASURES. September 2010

Written Program ELECTRICAL SAFETY. Based on OSHA Subpart S and NFPA 70E Standards

Wenaas Offshore. A new and innovative collection redefining the standard for flame retardant workwear

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

Automotive and Diesel Lab Safety Guidelines

What s up with Arc Flash?

Personal Protective Equipment Guidelines

Electrical Safety Program

MAXIMUM USE VOLTAGE AC/DC 500 / 750 1,000 / 1,500 7,500 / 11,250 17,000 / 25,500 26,500 / 39,750 36,000 / 54,000

University of Tennessee Safety Guidelines

SALISBURY ASSESSMENT SOLUTIONS

Hampshire College. Lockout/Tagout and Electrical Safety Program and Procedures

Ambulance/HART/SORT. Emergency Services. Jacket Radio and torch fittings Adjustable cuff tabs Zipped front with catch flap over

PROCEDURES FOR SAFE WORKING AND TESTING OF ENERGIZED ELECTRICAL EQUIPMENT

PAY TO PLAY: OSHA ISSUES NEW GUIDANCE ON EMPLOYEE PERSONAL PROTECTIVE EQUIPMENT (PPE) AND EMPLOYER DUTY TO PAY

Safe Operating Procedure

Presented by: Rich Perry Marsh Risk Consulting

Safety Training Topic PERSONAL PROTECTIVE EQUIPMENT

1Conduct Both a Shock

6. ASSESSING THE NEED FOR PERSONAL PROTECTIVE EQUIPMENT (PPE) IN THE LABORATORY

UL Validated Testing of Arc-Resistant Motor Control Centers

Respiratory Safety and PPE Module 7. Special Warehouse Worker Hazards in Structural Steel Fabricating and Supply Companies

PERSONAL PROTECTIVE EQUIPMENT POLICY & GUIDANCE

PERSONAL PROTECTIVE EQUIPMENT HAZARD ASSESSMENT, EQUIPMENT SELECTION AND TRAINING DOCUMENTATION

PERSONAL PROTECTIVE EQUIPMENT (PPE) a short guide for wildland firefighters

Amplitude Cotton/Nylon Protective Apparel Fabrics for NFPA 70E and NFPA 2112 Compliance

ELECTRICAL SAFETY / ARC FLASH PROGRAM

ARC FLASH CALCULATIONS & LABELING REQUIREMENTS

Installation Instructions for Alarm Module Kit A043F059

PROJECT HAZARD ASSESSMENT FORM CHEMICAL HAZARDS

Job Hazard/Safety Analysis For the Lab Worker

FIRE DEPARTMENT UNIFORMS

2008 Eaton Corporation. All rights reserved.

SUMMARY OF NFPA 1994 PROTECTIVE ENSEMBLES FOR FIRST RESPONDERS TO CBRN TERRORISM INCIDENTS, 2007 EDITION

ARC Flash Boundary & NFPA-70E Requirements PPE Program

Compressed Gas Cylinder Program

COMBUSTIBLE DUST in the WOOD PRODUCTS INDUSTRY

Arc Flash Hazards. Electrical Hazards. Dan Neeser Field Application Engineer Electrical Hazards 2/18/2015. Shock.

PERSONAL PROTECTIVE EQUIPMENT PROGRAM

Safe Operating Procedure

Texas Department of Insurance. Provided by. Personal Protective Equipment. Division of Workers' Compensation HS96-101C (10-06)

Trade Name of this Product Isopropyl Rubbing Alcohol 91% USP. Corporate Compliance Team 1666 East Touhy Avenue

Metal welding safety. Guidance Note. Practical advice for employers on controlling hazards when welding. June Background. How to use the table

Electrical Safety Program

Grounding and Bonding Against Static Electricity. Jon Koppari, CSP, MS Occupational Safety and Health Instructor OSHA Training Institute

Notes. Material 1. Personal Protective Equipment 2.

Process Safety Management of Highly Hazardous & Explosive Chemicals. Safe Work Practices

Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection. OSHA Office of Training and Education 1

Combustible Dust - Things that go Boom. W. Jon Wallace, CSP, MBA Workplace Group, LLC O: E: jwallace@workplacegroup.

Arc Flash Overview. Arc-Flash Hazard. Who is Eaton. Engineering Studies ABSTRACT. Eaton PSE s

UNIVERSITY OF CENTRAL FLORIDA ELECTRICAL SAFETY PROGRAM

FACILITY SAFETY SIGNAGE GUIDE: 10 SIGNS TO SPOT DURING A PLANT WALKTHROUGH

Standard Operating Procedure: Flammable Liquids

Safe Operating Procedure

PPE hazard assessment

HIGH VISIBILITY CLOTHING FOR HEAVY & HIGHWAY CONSTRUCTION

Guidelines for the Use of. Personal Protective Equipment

How many work-related eye injuries are there each day?

Explosion Prevention

1.0 Purpose Definitions Hot Work Operations. 5

TAMPA ELECTRIC COMPANY ENERGY SUPPLY ELECTRICAL SAFETY PROGRAM

GUIDE FOR SELECTION AND USE OF PERSONAL PROTECTIVE EQUIPMENT AND SPECIAL CLOTHING FOR FOUNDRY OPERATIONS

OSHA & ARC FLASH HAZARD ANALYSIS

EUROPEAN STANDARDS PERSONAL PROTECTIVE CLOTHING FOR FLAME RESISTANT. Alexander Gstettner, Lenzing AG Austria

OSHA Published First-Ever Arc Flash Protection Requirements for the Electric Power Industry Significant changes and unprecedented compliance

Transcription:

Get Your Employees READY FLAME RESISTANT CLOTHING

Electric Arc Flash Flash Fire Molten Metal Splash BE READY is the largest provider of managed flame resistant clothing (FRC) programs. Over half a million wearers get Ready for the Workday with FRC from - making the most trusted source to equip companies with FRC apparel in North America. With our professional commitment and diverse options, offers FRC products from manufacturers who engineer them to be more durable, more comfortable and lighter than any other garments of their type.

HAZARDS ASSESSMENT OSHA regulations require employers to provide their employees with personal protective equipment (PPE) in certain work environments to reduce employee exposure to hazards. For example, do your employees or contracted workers work on or near electricity or energized parts? work with flammable liquids or gases? weld or come into contact with molten metals? If you answered Yes to any of these questions, you should consult with a safety professional to determine whether a protective apparel program may be required. As an employer, it is your responsibility to comply with industry standards and OSHA regulations to protect your employees from hazards they may encounter. Failure to comply can leave your business liable and you may face the risk of litigation and government fines. After you have consulted with a safety professional and determined your employees PPE needs, can provide that PPE and design a laundry service program to fit your company s needs.

ELECTRIC ARC FLASH 6,000 Nearly 6,000 fatal electrical injuries occurred between 1992 and 2013* 5-10 Between 5 and 10 electric arc flash explosions occur every day in the US* 35,000 F Electric Arc Flashes produce temperatures up to 35,000 F* According to the Fire Protection Research Foundation, electrical injuries represent a serious workplace health and safety issue. Failure to use appropriate PPE for electrical safety work practices, including FRC, contributes to many electrical injuries. OSHA s Workplace Safety Awareness Council defines an arc flash as a phenomenon where a flashover of electric current leaves its intended path and travels through the air from one conductor to another, or to the ground. The results are often violent and when a human is in close proximity to the arc flash, serious injury or even death can occur. NFPA 70E is an industry standard which outlines how to properly protect your employees and create a safe working environment, as well as help your company comply with government regulations. NFPA 70E applies to all personnel working on energized equipment greater than 50 volts or equipment that could produce an arc flash which means virtually every industry has employees at risk. *Bureau of Labor Statistics, as published by the Fire Protection Research Foundation in Occupational Injuries from Electrical Shock and Arc Flash Events report.

SIMPLIFIED TWO-CATEGORY FLAME RESISTANT CLOTHING SYSTEM CATEGORY 2 REQUIRED PPE Also fulfills NFPA 70E requirement of Level 1 CATEGORY 4 REQUIRED PPE Also fulfills NFPA 70E requirement of Level 3 Safety glasses or goggles Hearing protection (inserts) Insulated rubber gloves with leather protectors EH heavy-duty leather footwear Arc rated long sleeve shirt/coverall (8.0 ATPV or higher) Arc rated long pants/coverall (8.0 ATPV or higher) Hard hat with Arc rated face shield and balaclava Arc rated coveralls Arc rated (40 cal) Arc Flash suit jacket Arc rated (40 cal) Arc Flash suit pants Arc rated (40 cal) Arc Flash suit hood

FLASH FIRE 16% Fire and explosions are responsible for 16% of fatalities in oilfields* 1,000-1,900 F Hydrocarbon (oil and gas) flash fires generate temperatures of 1,000 to 1,900 degrees Fahrenheit.* According to OSHA, a flash fire is a fire that spreads rapidly through a diffuse fuel, such as dust, gas, or the vapors of an ignitable liquid, without the production of damaging pressure. Combustible dust is a concentration of airborne particles in a closed area which can be ignited by a spark or even static electricity, potentially causing a flash fire. OSHA enforces policy 29 CFR 1910.132(a), the general industry standard for Personal Protective Equipment (PPE). This policy explains OSHA s position on providing and using Flame Resistant Clothing (FRC) in oil and gas well drilling, servicing and productionrelated operations. NFPA 2112 is the Standard on Flame-Resistant Garments For Protection of Industrial Personnel Against Flash Fire. This standard provides minimum requirements for the design, construction, evaluation and certification of flame-resistant garments. The NFPA 2113 standard specifies the minimum selection, care, use and maintenance requirements for FR garments. *OSHA

MOLTEN METAL SPLASH Molten metal splash commonly occurs when moisture or wet materials are introduced causing the metal to explode violently and throw dangerous molten metal into the air. 3,000 F Molten metal can reach temperatures up to 3,000 F, causing severe injury or death Failure to provide personal protective equipment designed for molten metal splash hazard is a serious infraction of OSHA standard 29 CRF 1910.132, the Occupational Safety and Health Act of 1970, and other regulations which can lead to convictions and fines.

MANAGING YOUR FRC PROGRAM Partnering with for your flame resistant clothing options delivers you three key benefits: comfort, convenience and care. COMFORT We offer a full line of retail inspired protective apparel from the best brands and fabrics. We individually fit uniforms for each employee to ensure the right look and fit. CONVENIENCE We save you time with weekly route services to collect soiled garments and return them after being professionally laundered according to industry best practices. CARE We follow industry standards regarding the laundering, repair and replacement of flame resistant clothing. Advantages of a managed industrial laundry program: Proper Laundering: Using appropriate water temperatures, water softness and chemical formulas. Weekly Inspection and Repair: Searching garments for holes, missing buttons and broken zippers and repairing with FR materials. Proactive Replacement: Retiring garments from service.

A TAILORED PROGRAM TO MEET YOUR NEEDS Once you have identified the appropriate PPE for your employees, you can choose a rental, lease or purchase program based on the needs of your workforce. RESPONSIBILITIES RENT LEASE PURCHASE Weekly Laundering Employee Employee Weekly Inspections Company Company Repairs Company Delivery Size Changes Company New Orders/Replacements Company Management of Program Initial Fitting We can add logos and names to your garments for a custom look. If the size of your workforce increases, we keep you Ready with additional uniforms for your employees. Contact us today to learn more about how can help you with your Personal Protective Equipment Program. 800.CINTAS1.com/ProtectiveApparel

CARHARTT FR RENTAL WORKWEAR Light Blue (80) Navy (20) 294 Carhartt 88/12 Long Sleeve Shirt 6.5 oz Khaki (62), Light blue (80), ATPV 9.5, ARC 2 ASTM 1506, 371 Carhartt 88/12 Pant 9 oz ATPV 12, ARC 2 ASTM 1506, 290 Carhartt Carpenter Jean 11.75 oz, 100% FR cotton Denim (83) ATPV 15.2, ARC 2 280 Carhartt Jean 14.75 oz, 100% FR cotton Denim (83) ATPV 23.8, ARC 2 391 Carhartt 88/12 Coverall 7 oz ATPV 8.6, ARC 2 ASTM 1506,

EXCLUSIVELY FROM CINTAS 297 Carhartt Long Sleeve T-Shirt 6.7 oz Heather Gray (31) ATPV 8.2, ARC 2, 63680 Carhartt FR Enhanced Visibility Shirt 6.5 oz ATPV 9.5, ARC 2 ASTM 1506, 63685 Carhartt FR Enhanced Visibility Pant 9 oz ATPV 12, ARC 2 ASTM 1506, 63686 Carhartt FR Enhanced Visibility Coverall 7 oz ATPV 8.6, ARC 2 ASTM 1506,

FLAME RESISTANT CLOTHING Light Blue (80) Light Blue (80) Navy (20) 7733 Tecasafe Plus Shirt 8.5 oz, Khaki (62), Light Blue (80) ATPV 9, ARC 2, 8803 Tecasafe Plus Pant 8.5 oz, ATPV 10.2, ARC 2, 8066 Tecasafe Knit Polo 6.7 oz, ATPV 8.2, ARC 2, UL 2112 Certified 656 Nomex IIIA Shirt 4.5 oz, Light Blue (80) Khaki (60), Navy (2) ATPV 4.5, ARC 1 60698 Nomex /Rayon Shirt 4.5 oz, Denim (83) ATPV 4.5, ARC 1 746 Nomex IIIA Pants 7.5 oz, ATPV 7.0, ARC 1 8803

Are your students protected? 80309 Nomex IIIA Vest/Jacket Liner ATPV 37, ARC 3 (Can be worn with 61356 or 9585) 64356 EXCEL FR Jacket Liner ATPV 43.3, ARC 4 61356 EXCEL FR Bomber Jacket ATPV 30.4, ARC 3 8723 Tecasafe Plus Coverall 7 oz, ATPV 10.2, ARC 2 (not shown) 737 Nomex IIIA Coveralls 6 oz,, Liberty Blue (26) ATPV 5.6, ARC 1 (not shown) 9632 FR Lab Coat 4.5 oz, Royal (26) ATPV 4.4, ARC 1 High-closing collar Extra large and passthrough pockets Easy open snap closure FR knit cuffs 746 8723

ENHANCED VISIBILITY 61286 60079 64302 64308 9585 61286 Orange E-Vis 88/12 Workshirt 7 oz, Orange ATPV 8.6, ARC 2, 60079 Orange E-Vis 88/12 Jacket 9 oz, Orange ATPV 12.2, ARC 2 64302 88/12 Shirt with Reflective Trim 7 oz, Light Blue (80) ATPV 8.7, ARC 2, 64308 Tecasafe Plus Shirt with Reflective Trim 8.5 oz, Khaki (62) ATPV 9.0, ARC 2, ENHANCED VISIBILITY OUTERWEAR: 9585 E-Vis EXCEL FR Bomber Jacket ATPV 30.4, ARC 3, 60078 Jacket Liner 15.5 oz, Grey Arc Rating N/A when worn alone. When worn with 60079, ATPV 61.3 (not shown) 64307 Tecasafe Plus Coverall with Reflective Trim 7 oz, ATPV 10.1, ARC 2, 64307

PERSONAL PROTECTIVE EQUIPMENT Additional PPE products available upon request. Arc Flash Suit 63545 Insulated Hand Tools 86935 Rubber Insulated Gloves Covers Classes 00, 0, 1, 2 86938 Leather Glove Protectors 10 and 12 82337 Indura UltraSoft Balaclava 89512 Arc Flash Protective Face Shield

800.CINTAS1 CINTAS.COM/PROTECTIVEAPPAREL UNIFORMS FACILITY SERVICES FIRST AID & SAFETY FIRE PROTECTION Pursuant to OSHA regulations, 29 CFR 1910.132 (Subpart I), an employer bears sole responsibility for selecting the type(s) of personal protective equipment to be used by its employees. All purchasers of FRC garments and/or laundering services from bear full responsibility for selecting the PPE appropriate for use by their employees. makes no representation, warranty, or covenant with respect to the flame-resistant qualities of the garments or with respect to the fitness or suitability of the garments for any particular use or purpose. The purchase of any goods or services from is subject to s Standard Terms and Conditions and/or any other applicable written contract executed between the purchaser and relating to such purchase. FRC 774 R0316