TRAUMATOLOGY. Vortex. Distalis Radius plate ±15

Similar documents
TRAUMATOLOGY. Vortex Catalogue.

NCB Distal Femur System. Surgical Technique

Zimmer Small Fragment Universal Locking System. Surgical Technique

PERIPROSTHETIC IMPLANTS

VariAx Distal Radius Locking Plate System. Anatomical & Universal Volar Plates Dorsal Plates Fragment Specific Plates

Aesculap Veterinary Orthopaedics. Targon VET Interlocking Nail

TwinFix Cannulated Compression Screw

How To Fix A Radial Head Plate

MINI FRAGMENT SYSTEM. Instruments and implants for 1.5 mm, 2.0 mm, and 2.4 mm plate fixation PRODUCT OVERVIEW

Technique Guide. 2.4 mm LCP Distal Radius System. A comprehensive plating system to address a variety of fracture patterns.

LCP Compact Foot/Compact Hand.

NCB Periprosthetic Femur Plate System. Surgical Technique

Zimmer Periarticular Elbow Locking Plate System

Zimmer Periarticular Proximal Tibial Locking Plate

Technique Guide. 3.5 mm and 4.5 mm Curved Locking Compression Plates (LCP). For minimally invasive osteosynthesis.

Technique Guide. Screw Removal Set. Instruments for removing Synthes screws.

V-TEK IVP System 2.7 System 4.0

The information contained in this document is intended for healthcare professionals only.

Surgical technique. End Cap for TEN. For axial stabilization and simultaneous protection of soft tissue.

MatrixNEURO CMF Matrix

NCB Proximal Humerus System. Surgical Technique

Orthopedic Foot Instruments. Dedicated instruments for reconstructive foot surgery.

ACTIV ANKLE DISTAL AND DIAPHYSEAL FIBULA INNOVATION MEANS MOTION

Technique Guide. Large Fragment LCP Instrument and Implant Set. Part of the Synthes locking compression plate (LCP) system.

Elbow System 2.0, 2.8

LCP Superior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle.

Achilles Tendon Repair, Operative Technique

Technique Guide. Orthopaedic Cable System. Cerclage solutions for general surgery.

DARCO MRS. Locked Plating System for Reconstructive Rearfoot Surgery

TriLock 1.5 Implants for the Phalanges

TABLE OF CONTENTS. Surgical Technique 2. Indications 4. Product Information Patient Positioning and Approach 2

Modular Sternal Cable System. Flexibility and strength in sternal closure and repair.

GENEL KATALOG GENERAL CATALOGUE KİLİTSİZ PLAKLAR NON LOCKING PLATES

Standard Internal Hex

Cable System. For Orthopaedic Trauma Surgery.

LCP Olecranon Plate. The anatomical fixation system with angular stability for olecranon and proximal ulnar fractures.

INTRODUCTION Cerclage Cable Vs. Monofilament Wire

TransFx External Fixation System Large and Intermediate Surgical Technique

Technique Guide. DHS/DCS Dynamic Hip and Condylar Screw System. Designed to provide stable internal fixation.

CLAW II. Polyaxial Compression Plating System SURGIC A L T ECHNIQUE

OptiLock Periarticular Plating System For Proximal Tibial Fractures. Pre-Launch Surgical Technique

Technique Guide. 4.5 mm LCP Proximal Femur Plates. Part of the Synthes Periarticular LCP Plating System.

Technique Guide. 2.7 mm/3.5 mm Variable Angle LCP Ankle Trauma System. Part of the Synthes variable angle locking compression plate (VA-LCP) system.

Titanium Wire with Barb and Needle. For canthal tendon procedures.

ICUC One-Page Paper. Mixing a lag screw with a splinting protection plate Alberto Fernández Dell Oca, Pietro Regazzoni, Stephan Perren May 2016

Zimmer Natural Nail System. Cephalomedullary Nail Surgical Technique STANDARD

Implant materials. Learning outcomes. Implant materials in trauma. How to use this handout? Functions of implants. Types of materials

Regular C/X Prosthetics. Prosthetics

ORTHODONTIC MINI IMPLANTS Clinical procedure for positioning. Orthodontics and Implantology

Adult Forearm Fractures

SALVATION. Fusion Bolts and Beams SURGICAL TECHNIQUE

LOMAS / MONDEFIT ORTHODONTICS. The most innovative anchorage method for tooth correction

How To Use A Phoenix Retrograde Femoral Nail

Technique Guide. Reamer/Irrigator/Aspirator (RIA). For intramedullary reaming and bone harvesting.

Knotilus TM. Anchor Instability Repair. Technique Guide

Expert LFN. Lateral Femoral Nail.

TABLE OF CONTENTS. Indications and Contraindications 3. Features and Benefits 4. Ease of connection 4 Stable fixation concept 5

Scaphoid Non-union. Dr. Mandel Dr. Gyomorey. May 3 rd 2006

NARROW DIAMETER implant

DRAFT. Triathlon TS Knee System. Surgical Protocol. Version 1

Expert ALFN. Adolescent Lateral Femoral Nail.

4052 Slimplicity Tech final_layout 1 6/29/15 3:29 PM Page 2 Surgical Technique

Wrist and Hand. Patient Information Guide to Bone Fracture, Bone Reconstruction and Bone Fusion: Fractures of the Wrist and Hand: Carpal bones

MatrixNEURO. The next generation cranial plating system.

Technique Guide. Titanium Trochanteric Fixation Nail System. For intramedullary fixation of proximal femur fractures.

Expert TN. Tibial Nail.

TRIMBLE TX5 3D LASER SCANNER QUICK START GUIDE

Double Bone Plug Meniscus Reconstruction Surgical Technique

DHS/DCS System. Including LCP DHS and DHS Blade.

Anatomic Percutaneous Ankle Reconstruction of Lateral Ligaments (A Percutaneous Anti ROLL)

Expert HAN. Expert Hindfoot Arthrodesis Nail.

DESS. Screws. Tijuana Ventas: (664) /95 For all major implant systems!!

Shoulder Restoration System

LISS PLT. The less invasive stabilization system for proximal tibia fractures.

CeSpace Titanium / PEEK

Foot and Ankle Technique Guide Proximal Inter-Phalangeal (PIP) Fusion

Versa-Fx II Femoral Fixation System Surgical Techniques

Rigid Internal Fixation of Displaced Distal Radius Fractures

Citation International Orthopaedics, 2011, v. 35 n. 3, p Creative Commons: Attribution 3.0 Hong Kong License

No Rainfall Data is Collected

MEDACTA UNCONSTRAINED SCREW TECHNOLOGY. Surgical Technique. Hip Knee Spine Navigation

Replacement of the upper left central incisor with a Straumann Bone Level Implant and a Straumann Customized Ceramic Abutment

Posterior Referencing. Surgical Technique

ACCORD Cable System. Surgical technique completed in conjunction with: Robert Barrack, MD St. Louis, Missouri. Paul Di Cesare, MD New York, New York

Anterior Lumbar Interbody Fusion (ALIF). Instrument set supports placement of ALIF spacers using anterior or anterolateral approach.

Guidance for implant removal. Straumann Dental Implant System

PATIENT SPECIFIC PLATES FOR MANDIBLE: CUSTOM MADE PLATES FOR TRAUMA AND RECONSTRUCTION

Re-board Accessories

INTRODUCTION INTERLOCK KIT K-8110

Universal Screw Removal System (USR)

the revo / mini-revo shoulder fixation system s u r g i c a l t e c h n i q u e

Go-kart for little race-drivers

Lentur Cable System. Surgical Technique

FEMTO-CATARACT INSTRUMENTS Speculum SPECULUM FOR DOCKING STATION

Distal Radius Fractures. Lee W Hash, MD Affinity Orthopedics and Sports Medicine

FRONT BUMPER INSTALLATION INSTRUCTIONS DODGE / MERCEDES SPRINTER

Minimally Invasive Hip Replacement through the Direct Lateral Approach

Abdominal Pedicle Flaps To The Hand And Forearm John C. Kelleher M.D., F.A.C.S.

Micro Precision Tools Your partner for precision applications

STEADYfast Stabilizer Installation Notes Fifth Wheel and Travel Trailers 11/23/13

Transcription:

Vortex TRAUMATOLOGY Distalis Radius plate ±5

References Content. Intrduction Dr. Béla Turchányi PhD. Head of Department, Associate Professor Kenézy Gyula Kórház és Rendelőintézet..2.3 The implant The instruments Indications Debrecen 2. Implant range 5 Dr. László Vámhidy PhD. Head of Department, Clinical Director MSI Department of Traumatology and Hand Surgery Pécs, Hungary Dr. Ferenc Tóth Chief Medical Director Főv. Önk. Péterfy Sándor úti Kórház Rendelőintézet és Baleseti Központ, Budapest, Hungary The following surgical description contains general outlines for radius plate fixation with the Vortex Distal Radius plate system. However, the operating surgeon shall adapt the content to the patient, fracture type and all other relevant factors that may have influence on the outcome of the surgery. Therefore, Sanatmetal Ltd. strongly recommends participation on workshops and trainings prior to the initial operation. 3. 3. 3.2 3.3 3. 3.5 3. 3.. 3..2 3.7 3.7....2.3. 5. 5. 5.2 Surgical description -9 Patient positioning Incision Selecting the plate size Insertion of the plate Fixing the oval hole 7-8 Fixing screws in the head of the plate 8 Drilling through polyaxial sleeve 9 Drilling through neutral sleeve 0 Angle stabilized locking on the tail 0 Drilling through neutral sleeve 0 Implant list -2 Vortex distal radius plate V Vortex distal radius plate V+ Vortex screw 2.7 mm 2 Cortical screw - TX Ø2.7 mm 2 Instrument list 3- Filled-up tray 3 Instruments

Introduction Implant range 2 The Vortex Distal Radius plate is the first member of the polyaxial angle stabilized plate family of Sanatmetal. It offers wide range of possibilities for the precise and secure fixation of distal radius fractures. The screws can be inserted in ±5 deg angulation from preset anatomical directions enabling the surgeon to perform the most modern treatment of the fracture.. The implant.2 The instruments 2. Vortex Distalis Radius plate - V Holes on head Holes on tail Type Large 5+ 3; 5; 8 left/right Medium +3 3; 5; 8 left/right Small 3+2 3; 5; 8 left/right Polyaxial angle stabilized system in step - free ±5 deg angulation of insertion Capable of drilling in preset and ±5 deg step - free directions Instruments and implants in one tray Optimized instruments Raw material Colour szürke Maximum 3 times of correction possibility when misidentifying the correct screw direction towards the fragment Ability to perform minimally invasive surgery Oval hole for plate fixation Rounded edges to protect nearby soft tissues Thinned head, the implant does not interfere with the wrist area tissues Holes for temporary Kirschner wires Self tapping but blunt ended screws to avoid tissue irritation 2 mm plate thickness Anodized Titanium raw material Torx headed screws Two different plate contours, the eared version is for fixing Styloid Processus fragments.3 Indications Distal radius fractures. 2.2 Vortex Distalis Radius plate - V+ Holes on head Holes on tail 2.3 Vortex screw Ø2,7 mm 2. Cortical screw - TX Ø2,7 mm Type Large 5+ 3; 5; 8 left/right Medium +3 3; 5; 8 left/right Small 3+2 3; 5; 8 left/right Raw material Colour Grey Length 8-3 Length 8-3 Raw material (in mm steps) Raw material (in 2 mm steps) Colour Colour Blue Grey 5

3 S urgical description 3. Patient positioning 3.5 Fixing the oval hole Patient is in supine position, the affected limb is straight and supported while the palm is upwards. The first screw is inserted into the oval hole of the plate. 3.2 Incision To do so place and sink the neutral sleeve of the double drill sleeve into the middle of the oval hole. Perform drilling with 2 mm spiral drill (). Make a longitudinal incision from flexor carpi radialis to slightly radial direction. Locate FCR, radial artery, separate pronator quadratus from the lateral part of radius and lift above the ulna. 3.3 Selecting the plate size Select the plate of that size where the head of the plate is equivalent to the distal radius width. Take also into consideration the positions of the fragments. Whenever needed modellate the plate to the shape of the bone surface with bending tools. To modellate the plate enter the tools threaded part into the holes of the plate and perform bending. To determine the length of necessary screws there are two possibilities. ) The laser marking on the drillbit functions as a length gauge. Push the stop to the surface of the sleeve. After the removal of drilling read the necessary screw length just below the stop (2). 3 3. Insertion of the plate The optimal position of the plate is reached when the arched head of the plate is in level with the distal radius. Fix the reposition with temporary Kirschner wires through the plate if needed. Pay close attention that the plate shall not interfere with the joint. 2 2) After the removal of the drill and the sleeve guide the length gauge through the bone, hit against the bone surface, place the hook on the farther edge of the hole. Read the screw length at the red mark (3). 7

3 S urgical description Drive in the screw with the Torx screwdriver (). The screw should be tightened only to such an extent that the position of the plate could be corrected in longitudinal direction. 3.. Drilling through polyaxial sleeve Place and sink the polyaxial sleeve into the hole of the plate. Perform drilling with 2 mm drillbit. Pay attention not to drill into the joint. If the position of the plate is optimal tighten the screw in the oval hole. As soon as the screw head touches the plate switch to torque limiting screwdriver to avoid excessive torque. (5) Pay attention that the plate shall not harm wrist joint. Remark Plates with bent ears provide fixation possibilities for fragments of Styloid processus. 5 Attention When pre-drilling for polyaxial screw only the traditional length measurement could be used. Guide the length gauge through the bone, hit against the bone surface, place the hook on the farther edge of the hole. Read the screw length at the red mark. 3. Fixing screws in the head of the plate After setting the optimal position of the plate first fix the screws of the head. It is possible to insert the screws into preset anatomical directions. To achieve this pre-drill with the neutral (straight) sleeve see point 3..2. To enter the screws within ±5 deg direction from the preset, use the polyaxial sleeve to obtain polyaxial angle stabilized connection between the plate and the screw. See 3... 8 Drive in the screw with Torx screwdriver. The insertion of the screws is possible in ±5 deg angular deviance from the anatomically preset directions while maintaining the angle stabilized locking. As soon as the screw head touches the plate switch to torque limiting screwdriver to avoid excessive torque. ±5 Perform the above in case of all screws considered necessary. 9

3 Surgical description 3..2 Drilling through neutral sleeve Place and sink the neutral (straight) sleeve of the double drill sleeve into the hole of the plate. Perform drilling with 2 mm drillbit. According to point 3.5 the screw length determination could be made in two ways. After length gauging fix the screw with Torx screwdriver. Screw insertion is possible in the preset directions while maintaining angle stabilized locking. As soon as the screw head touches the plate switch to torque limiting screwdriver to avoid excessive torque. Perform the above in case of all screws considered necessary. 3.7 Angle stabilized locking on the tail On the tail of the plate it is possible to apply polyaxial and cortical screws. The appropriate axial stability is reached in case of perpendicular screw insertion. For anatomical reasons the usage of Vortex angle stabilized screws is suggested. 3.7. Drilling through neutral sleeve Place and sink the neutral (straight) sleeve of the double drill sleeve into the hole of the plate. Perform drilling with 2 mm drillbit. According to 3.5 perform length gauging by any of the described method and fix the screw with Torx screwdriver. As soon as the screw head touches the plate switch to torque limiting screwdriver to avoid excessive torque. 0

Implant list Implant list. Vortex Distalis Radius plate - V.3 Vortex screw Ø2,7 mm. Cortical screw - TX Ø2,7 mm.2 Vortex Distalis Radius plate - V+ Type Holes (H+S) Length (mm) Large Left 9 + 3 5 280503 Large Left 9 + 5 70 280505 Large Left 9 + 8 9 280508 Large Right 9 + 3 5 2805203 Large Right 9 + 5 70 2805205 Large Right 9 + 3 9 2805208 Medium Left 7 + 3 52 2805303 Medium Left 7 + 5 8 2805305 Medium Left 7 + 8 92 2805308 Medium Right 7 + 3 52 280503 Medium Right 7 + 5 8 280505 Medium Right 7 + 3 92 280508 Small Left 5 + 3 50 2805503 Small Left 5 + 5 2805505 Small Left 5 + 8 90 2805508 Small Right 5 + 3 50 280503 Small Right 5 + 5 280505 Small Right 5 + 3 90 280508 Type Holes (H+S) Length (mm) Large Left 9 + 3 3 28003 Large Left 9 + 5 79 28005 Large Left 9 + 8 03 28008 Large Right 9 + 3 3 280203 Large Right 9 + 5 79 280205 Large Right 9 + 3 03 280208 Medium Left 7 + 3 59 280303 Medium Left 7 + 5 75 280305 Medium Left 7 + 8 99 280308 Medium Right 7 + 3 59 28003 Medium Right 7 + 5 75 28005 Medium Right 7 + 3 99 28008 Small Left 5 + 3 55 280503 Small Left 5 + 5 7 280505 Small Left 5 + 8 95 280508 Small Right 5 + 3 55 28003 Small Right 5 + 5 7 28005 Small Right 5 + 3 95 28008 8 2082708 9 2082709 0 208270 20827 2 208272 3 208273 20827 5 208275 20827 7 208277 8 208278 9 208279 20 2082720 2 208272 22 2082722 23 2082723 2 208272 25 2082725 2 208272 27 2082727 28 2082728 29 2082729 30 2082730 3 208273 32 2082732 33 2082733 3 208273 8 27527008 0 2752700 2 2752702 275270 275270 8 2752708 20 27527020 22 27527022 2 2752702 2 2752702 28 27527028 30 27527030 32 27527032 3 2752703 2 3

5 I nstrument list Instrument list 5 5. Filled-up tray 5.2 Instruments Surgical instruments Description Quantity Cat. no. Screwdriver T9 20720009 T9/ Nm 205003 Plate bender mm 2 28090 Length gauge 2,7-3,5 mm 280905 2 mm 280902 2x25 mm 280903 Kirschner wire.2x00 mm 0 9375200 Screw forceps mm 939999002 Drill stop 2 mm 2 2050222 Tray (empty) VDR 23380005 Filled-up tray (VDR) 2338000 Torque screwdriver Double drill sleeve - PAS Spiral drill with quickconnecting end Screwdriver Torx (T9) 20720009 Torque limiting screwdriver (T9/ Nm) 205003 Plate bender ( mm) 28090 Depth gauge (2,7-3,5 mm) 280905 Double drill sleeve - PAS (2 mm) 280902 Spiral drill with quick connecting end (2x25 mm) 280903 Kirschner wire (,2x00 mm) 9375200 Screw forceps ( mm) 939999002 Stop (2 mm) 2050222 5

Product family TRAUMATOLOGY.. Intramedullary nails.2. Plates.3. Screws.. Fixateur externe.5. Other ORTOPAEDICS DENTAL SPINE Contact address: 5, Faiskola st. 3300 Eger, Hungary e-mail: metal@sanatmetal.hu phone: +3 3 52 900 fax: +3 3 52 932 www.sanatmetal.com REV_B 3/2/202