General Injec3on Presenta3on

Similar documents
Guide to working on Public Sewers

MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS

The AQUAFIN Approach to Concrete Repair

If stepping is required, step at 180mm as seen in this picture.

SECTION REMOVAL OR ABANDONMENT OF EXISTING UTILITIES AND UNDERGROUND STRUCTURES. 1. Trench excavation, backfill, and compaction; Section

FY08 SEWER POINT REPAIRS BID TABULATION

SECTION STORM DRAINAGE SYSTEM

ELECTRIC PERISTALTIC MORTAR POINTING PUMP

PmB Expansion Joints World leaders in expansion joint technology

INCREASE OF DURABILITY AND LIFETIME OF EXISTING BRIDGES. PIARC TC 4.4 EXPERIENCE.

Emergency repair of Bridge B421

CCU Engineering Specifications. Section PRECAST CONCRETE PRODUCTS

How to build a Pizza Oven in 4 days

Concrete Waterproofing Systems. Integral Protection.

PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta

What Causes Foundation Leaking?

UNIVERSITY OF CHICAGO ELEVATOR PIT LEAK REPAIR

WATERPROOFING SikaFuko INJECTION HOSE SYSTEMS UNIQUE WATERPROOFING SOLUTIONS FOR CONSTRUCTION JOINTS

Chapter. Restoration of Damaged Structures

Basement & Foundation Damage

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

How To Repair A House

Project Portfolio. Tunnels & Shafts

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

TECHNICAL NOTE Culvert Sliplining and Lining of Casings with HPPipe

REHABILITATION OF THE FIGUEIRA DA FOZ BRIDGE

Safe & Sound Bridge Terminology

FY11 Sanitary Sewer Main Rehab and Point Repair Bid Tabulation

Current opportunities of sprayed waterproofing membrane. Frank Clement Technical Manager Sprayable Membranes MEYCO Global Underground Construction

FUTURE SLAB. PENETRATIONS and. DEMOLITION of POST-TENSIONED FLOORS

symptoms of a faulty foundation

BEST MANAGEMENT STANDARDS FOR FOUNDATION REPAIR MARCH 2003 REVISED JUNE 13, 2012

SECTION STORM DRAINAGE STRUCTURES. 1. Trench excavation, backfill, and compaction; Section

Product Systems AQUAFIN-IC CEMENTITIOUS CRYSTALLINE PENETRATING WATERPROOFING. Waterproofing Specification

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

The unit costs are based on the trend line of the 3 low bids for the average quantity.

SPR PE Steel Reinforced Liner

SECTION STORM DRAIN SYSTEM

The Guide To Waterproofing An Existing Basement

San Antonio Water System Standard Specifications for Construction ITEM NO SLIP-LINING SANITARY SEWERS

BEST MANAGEMENT STANDARDS FOR FOUNDATION REPAIR

THORO. Waterproofing Systems

Improving the flood resistance of your home. Advice sheet 4: Flood-resilient walls.

Resurfacing Concrete. Page 1 of 5

ASHULIA APPARELS LTD. Client Summary Report

Energy Company Obligation (ECO): Technical Monitoring Questions

WATERPROOFING SikaProof -A TECHNOLOGY

TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE

MAPEI s Resfoam polyurethane products

LAYING BLOCK AND BRICK

Site Inspection Report

Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing

Section EXTERIOR STONE VENEER Full Mortar

Section SEWER PIPE INSTALLATION AND TESTING

SikaProof A Technology

PUBLIC WORKS DESIGN, SPECIFICATIONS & PROCEDURES MANUAL LINEAR INFRASTRUCTURE

Internal Basement Waterproofing Newton System 500

School Construction Authority Architecture & Engineering

BILL OF QUANTITY FOR THE WORK OF "REPAIRING OF CIVIL & PLUMBING WORKS INSIDE AND OUTSIDE OF THE WORKSHOP"

Basement Moisture Problems

0331 Brick and block construction

Membrane for tunnels and underground construction

How To Retaining Wall Guide

Technical Data Sheet Art. No Kiesol. applications. Shelf-life. rate depending on application. Characteristic data of the product

Geotechnical Building Works (GBW) Submission Requirements

World Tunnel Congress Underground Facilities for Better Environment and Safety - India

MHD BRIDGE SECTION WEIGHTED AVERAGE UNIT PRICES GUIDELINES FOR THE USE OF THE WEIGHTED AVERAGE UNIT PRICE TABULATION SHEETS

Rehabilitation of an Aging Concrete Reservoir Adit Tower

STRUCTURAL ASSESSMENT. Full Metal Jacket Building 0 Prince Street, Alexandria, VA

~iffiui ~ Bridge Condition Survey. Inspection Date: 21 May 2003 District: San Angelo County: Tom Green Highway:

June 2007 CHAPTER 7 - CULVERTS 7.0 CHAPTER 7 - CULVERTS 7.1 GENERAL

STANDARD SPECIFICATIONS FOR PRIVATE BUILDING SEWER LINES IN PUBLIC RIGHT-OF-WAY

Foundation Water Problems. An Overview and Discussion of some Causes and Cures for Water Infiltration into Basements and Foundation Structures

Value of Instrumentation Systems and Real-Time Monitoring: An Owner s Perspective

Shower Walls and Tub Surrounds

COPYRIGHT. Dincel Construction System Pty Ltd

Concrete Waterproofing Systems

Ground movement claims. Your claim - what happens next?

Meeting the Challenge of Pipeline Emergency Repair

Slab Track Austria. System ÖBB-PORR elastically supported slab

REVIEW OF TRENCHLESS TECHNIQUES FOR THE REHABILITATION OF SEWERS. Gerhard (Gerry) P. Muenchmeyer, P.E. Muenchmeyer Associates, LLC

Metropolitan Builders Association Masonry & Concrete Standard

Wastewater Capital Projects Management Standard Construction Specification

Integrated Manhole Ladder System

Technical Notes 3B - Brick Masonry Section Properties May 1993

Proposed Minimum Subterranean Termite Treatment Standards

The URETEK Deep Injection Process (UDI) For Roadways and Building Structures

Virginia Approach Spans

TBM CROSSING OF STATIONS

Non Destructive Waterproofing Remedial Treatment

APPLICATION PROCEDURES FOR PLACEMENT OF UNDERGROUND TELECOMMUNICATION CABLES IN THE VICINITY OF TRANSPORTATION FACILITIES

DIY GUIDE 10 EASY STEPS FOR TREATMENT OF RISING DAMP

STANDARD SPECIFICATIONS SECTION INSTALLATION OF GRAVITY SEWER PIPELINES. 1. Trenching, Backfilling and Compacting: 02223

1.3.2 Method of construction and restoration of existing water service connections. This shall include:

ARCHITECTURAL TECHNOLGY 4 ADVANCED CONSTRUCTION TECHNOLOGY BASEMENT CONSTRUCTION YEAR 3 SEMESTER 1 AIDAN WALSH R Lecturer: Jim Cahill

BEST PRACTICE GUIDELINES FOR CULVERT LINER SELECTION

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

Sources A recent survey of leaking basements showed water comes from a variety of sources, but walls are the usual culprit: Occurrence of moisture

WATERPROOFING OF WET ROOMS

Structural Retrofitting Process and Techniques

Transcription:

Tom Phillips General Injec3on Presenta3on

Company Profile Tempo-PCE working with Uk Councils & large contractors since 2002. ShaDs, tunnels, bridges, new or refurbishment. Works over or on watercourses to the sea, canal or river. Specialising injec3on : Strengthening, waterproofing, ground injec3on. Poor access, watercourse or confined space & emergency structural works.

Company Profile Emergency call outs Complex brick, concrete & founda3on repairs. Specialist repairs par3cularly suited for listed structures. Members of Construc3on Line, CHAS, Safe Contractor & Acclaim.

Waterproofing Injection! High pressure crack injec3on! Slow leak or damp sealing in concrete or brick structures

Waterproofing Injection! General slow water sealing using flexible polyurethane! Can be used in brick with careful control of injec3on pressure

Waterproofing Injection! Using PU s or Acrylic for injec3on tubes or 3ght cracks! Water is pushed out as material expands

Waterproofing Injection! Potable water safe materials! Over or in watercourses, reservoirs with E.A & Waterboard approvals! 8 to 10mm holes to retain appearance of structure! Heritage structures can be waterproofed

Waterproofing Injection! Acrylic resin injected between steel soffit and concrete backfill! An3 corrosive proper3es

Waterproofing Injection! Drilled & injected from the underside no affect to traffic! Not possible for the u3lity companies to damage unless they really try

Waterproofing Injection! The injec3on equipment is small enough to fit down manholes! The same process can be used to bond concrete to steel using PU s

Waterproofing Injection! Acrylic water proofing can be used in service trays to surround services mixing in with the exis3ng back fill.! Material is like a jelly so will break up if the u3li3es require access! Injec3on from above or below

Waterproofing Injection! This typical expansion joint has a clay dam either side and the material is then poured in between. Water is able to drain across using the white pipe.

Fast leak Injection! Fast leaks! Small heading in flowing sands! Use of PUs to hold ground

Fast leak Injection! Fast leaks & flowing sands through the use of Acrylic or polyurethane injec3on

Stabilisation Injection! Ground stabilisa3on using PUs or Acrylic! Underpinning of founda3ons or subsidence! Tunnel or large void filling! Temporary support during a dig out of a heading, trench or cross passage.

Stabilisation Injection! Flowing sands: Using a method of injec3on of a structural polyurethane a safe working method is achieved

Structural Injection! Hard to access areas, generally without restric3ng live traffic! Thickening of arch barrel, using back fill to link to exis3ng masonry with the use of PUs! Removal of ring separa3on! Bonding to exis3ng saddle! Supported by independent assessment methods

Structural Injection Post injec3on & core crushing: This sample has been injected with a high flexible latex/ cemen3tous grout, material strength is 25N.! Fills voids! Retains flexibility of the structure! Retains appearance of structure! Bonds to exis3ng concrete saddle! Replaces missing mortar! Low pressure injec3on 0.5 to 40 bar site specific pressures! Marketed by Normet Uk as TamCrete 25FG! No jacking

Typical Injec3on Cost Example cos3ng for strengthening and waterproofing (not including prelims or site restric3ons): Cost per square metre, 180 to 245 m 2 Cost per linear metre, 990 to 1350 /m Example cos3ng for waterproofing only (not including prelims or site restric3ons): Cost per square metre, 110 to 150 m 2 Cost per linear metre, 630 to 830 /m

Structural Injection! Heritage approved blended hydraulic Lime grout injec3on can achieve a maximum strength of 12 Newtons! Lime injec3on similar to structural injec3on, can only be injected at low pressure, typically 1 to 3 bar.! Different types of lime grout for filling large voids and different strengths.

Structural Injec3on I GAP System from Normet! Unrestricted live traffic! Bonding brick rings together! Filling of voids! Waterproofing! Three Network Rail structures completed

On Site Monitoring A typical grout injec3on method is, start at base working working upwards, row by row.

On Site Monitoring

On Site Monitoring Different materials can be indicated on the injec3on grids Injec3on maps reflect shape of structure to facilitate later iden3fica3on Exis3ng drawings can be introduced, illustra3ng individual areas and allowing addi3onal detail e.g. set 3mes Various injec3on phases can be shown South Service Tray, See rows 21- Abutment Abutment between between Vault Vault E1 E1 & E2, E2 See rows, See rows 4-18 4-18 Vault Vault has has angled Abutement angled wall Abutement to east. Next wall Span to east. East Next is Span over West river is Rail Span North Service Tray, See rows 1-3 Eastern Vault 1: Section Columns A B C D E F G H I Row 21 1.1 32 32 32 32 4 1.1 20 1.1 32 32 32 32 4 1.1 19 1.1 32 32 32 32 4 1.1 18 1.1 1.1 17 1.1 2 6 1.1 16 1.1 1.1 15 1.1 2 1 1.1 14 1.1 1.1 13 1.1 2 1.1 12 1.1 1.1 11 1.1 16 4 2 1.1 10 1.1 1.1 9 1.1 1 1 1.1 8 1.1 32 32 1.1 7 6 5 4 3 2 1 South Service Tray Abutment between Vaults E1 & E2 North Service Tray Eastern Vault 1: Plan Key Area Non-existent to inject Uninjected areas vault Abutment & Bearing plates Injected TAMPur 100 : Set 5 minutes Injected TAMAcryl 2000 : Set time 5 Minutes Injected TAMAcryl 2000 : Set 15 to 20 minutes Injected TAMAcryl 2000 : Set 2 hours to 2 days Injected TAMAcryl 2000 :With in 1 week Eastern Vault 1: Injection Map Total injection to service trays: 448.0 Total injection to bearing/abut: 30.8 Total injection to soffit: 37 Total of TAMAcryl 2000 to Vaults 515.8 Total of TAMPur 100 to Vaults 12 all quantities in kg columns represent vertical grid, approx. 750mm strips Title Injection Locations & Quantities, Total Location Ladywell Bridge, Eastern Vault 1 Client London Borough of Lewisham Issued By G Van Lierop Page No. 5 Drawing Number E1-T-110630 9 Artesian Close, London NW10 8RW

Brick & Concrete Repairs! Bespoke repair solu3ons including confined spaces.

Brick & Concrete Repairs! In house temporary works design

Brick & Concrete Repairs! Confined space emergency repairs! All types of brick & concrete repairs! Over water courses using rads! Inverted brick & concrete repairs! Sand blas3ng & general steel repairs

Thank you