SITE-LOG LPV-1/LPVB-1

Similar documents
USB-500 Series Low-Cost Data Loggers and Accessories

USB-500/600 Series Low-Cost Data Loggers and Accessories

USB-500 Series Stand-Alone, Low-Cost Data Loggers

Temperature & Humidity SMS Alert Controller

USB-500/600 Series Low-Cost Data Loggers and Accessories

Temperature Datalogger Users Manual

Data Loggers for Real Time Temperature Monitoring - WiFi

DataView DVTH Data Logger for Temperature and Humidity


EL-USB-2-LCD FEATURES WINDOWS CONTROL SOFTWARE DISPLAY FUNCTIONS. Page 1 of 5

SMS GSM Alarm Messenger

EVAL-UFDC-1/UFDC-1M-16

EL-USB mA Current Loop USB Data Logger

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

NETWORK ENABLED EQUIPMENT MONITOR

EL-USB-1-LCD Temperature Data Logger with LCD

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

Current Monitoring Kit QUICK START GUIDE

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

Current Monitoring Kit

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

KACO-monitoring. onlinecomponents.com. Integrated monitoring available. Monitor up to 32 inverters per prolog. Reliable and accurate data

MSITel provides real time telemetry up to 4.8 kbps (2xIridium modem) for balloons/experiments

Nardalert S3 Non-Ionizing Radiation Monitor

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Simplify Data Acquisition with a Built-in LXI Web Server

NEW. EVEN MORE data acquisition and test stand automation

A-307. Mobile Data Terminal. Android OS Platform Datasheet

Online Monitoring User Guide

Engineering and service software For KNX and LPB plants

Fingerprint Based Biometric Attendance System

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

The Universal DAQ Device. Connect and measure immediately!

Long Distance Industrial Wireless Transmitters and Receivers

User Guide. Temperature and Humidity Datalogger. Model 42280

Premium Server Client Software

This datalogger is ideal for the Food Industry where process profiling is crucial to production efficiency and energy use optimisation.

Versions. Q.station Q.station T. Q.station D. Q.station DT x x

Impedance 50 (75 connectors via adapters)

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Wireless Data Logger Monitoring Systems

FT-1000/GPS-N. System of remote monitoring and control of physical

PMS. Energy management and monitoring software. Installation and operation instructions

PMS. Energy management and monitoring software. Installation and operation instructions. BMR trading Horní lán Olomouc Czech Republic

Disturbance Recoder SPCR 8C27. Product Guide

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

NortechCommander Software Operating Manual MAN R6

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

EL-USB-TC-LCD Thermocouple Data Logger with LCD and USB Interface

IO-DIM6 6-Channel, Digital to Analogue Converters

securityprobe5es -X20

I2C PRESSURE MONITORING THROUGH USB PROTOCOL.

DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:

Instruction Manual Service Program ULTRA-PROG-IR

Transmitter Interface Program

Hand-held thermometer Model CTH7000

ALL-USB-RS422/485. User Manual. USB to Serial Converter RS422/485. ALLNET GmbH Computersysteme Alle Rechte vorbehalten

Repeaters and Mimics Data Sheet

How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers.

Omega ICD Intelligent Colour Display

User s Manual of BTGP-38KM Bluetooth GPS Data Logger V1.0

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Data Logging Solutions from Lascar Electronics

Frequency selective monitoring and logging of environmental electromagnetic fields

IR-PRO IR-PRO. Operation Guide. Professional Infrared Code Capture System

Fiber Optic Distributed Temperature Sensor (B-DTS)

imc BUSDAQ autonomous intelligent synchronized Field bus data acquisition - from stationary to mobile imc productive testing

SupcoLog Logger Interface Software

Temperature Alert. LAN-based Temperature and Humidity Data Logger

Product Data. Thermal Comfort Data Logger Type Including Application Software Type 7301

USER MANUAL V5.0 ST100

DS1104 R&D Controller Board

SNMP Web Management. User s Manual For SNMP Web Card/Box

Product Specification instalert Rapid Messenger Variable Message Sign

Automated Time & Attendance System BIG EFFICIENCY FOR BUSINESS

PLC GPRS NET Data Logger

1 Technical Description Lokal-200PC

4-Channel Thermometer / Datalogger

USB Edition TM-STD30 User Guide

1. SAFETY INFORMATION

TAC I/NETTM. Process Control Unit

FLYPORT Wi-Fi G

SNC-VL10P Video Network Camera

In-Sight Hardware specifications

Remote Monitoring Unit SC8100. Monitoring Unit SC8100

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Sensor Monitoring and Remote Technologies 9 Voyager St, Linbro Park, Johannesburg Tel: ;

RN-XV-RD2 Evaluation Board

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

WD-AMX Water Detection Controllers

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

AXIS 262+ Network Video Recorder

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000

HOBO Single Channel Thermocouple Data Logger (UX M) Manual

Features. Introduction. Applications. VPD-130/VPD-130N with DIN-Rail Mounting. VPD-130/VPD-130N Panel Mounting. Excellent C/P ratio (cost/performance)

10 Thomas, Irvine, CA USA Tel: (949) Fax: (949) Toll Free: (800) 23 FUTEK

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

Transcription:

SITE-LOG LPV-1/LPVB-1 Product Specifications OVERVIEW The SITE-LOG LPV-1/LPVB-1 is an 8- channel, battery powered, stand-alone voltage data logger, with storage up to 4 MB of data in non-volatile flash memory. Input voltage signals can be from sensors, transducers, transmitters or any other common voltage sources. Its aluminum enclosure makes it excellent in the harshest industrial environment. Plug & Play USB port and versatile custom equation simplify communications and engineering unit conversion. 16-bit ADC makes it well suited for science and laboratory applications where precise and accurate measurements are critical. Simply plug the logger to computer's USB port, and the software automatically recognizes it and handles the configuration, downloading, graph viewing and more FEATURES High Data Resolution: The 16-bit analog-to-digital converter meets most high-resolution Large Memory Size: The 4-Mega-Byte Memory stores years of measurements. Programmable Input Ranges: One on-board thermistor channel monitors ambient temperature. Seven rangeprogrammable voltage external input channels cover wide measurement Multiple Communication Interfaces: The SITE-LOG data loggers can be accessed via USB, MODEM, or Ethernet connections with auto baud rate of up to 115 kbps. Its on-board TTL serial port and USB interfaces meet most communication 1

USB Port TTL Serial Port Alarm & Excitation Control 10-Year Battery Life: The internal lithium battery provides over 10 years of instantaneous logging operation when sampling at an interval of one minute. Fast Sampling Mode: The SITE-LOG data loggers can log data with the sampling interval as fast as 20 milliseconds, replacing data acquisition devices. Alarm and Excitation Outputs: The SITE-LOG data logger notifies the alarm condition over alarm terminal strips or communication lines. (USB, Serial Port, MODEM) Rugged Physical Design: The rugged aluminum enclosure and coated PCB makes the Site-Log data loggers perfect in the harshest industrial environment. Aluminum Case Excitation control turns on the power of external transmitter/transducer only when the logger is sampling. SITEVIEW SOFTWARE FEATURES SiteView is a PC based application works with Site-Log Series data loggers for downloading, configuration and data analyzing and plotting. Its user-friendly graphic interface plus powerful functionalities fit both novice and advanced users. The versatility of custom equation and custom-line equation handle complicated measurement Features: Support USB, Serial port and Ethernet connections for easy local and remote access Fast communication speed up to 115200 bps makes downloading fast 2

Real-time view and chart recording replaces chart recording device Custom equation and custom-line equation solves scientific and laboratory algorithm difficulties Zoom in/zoom out, annotation/label of graph functions provide detailed view of data Multiple file loading allows easy data comparison Dynamic statistics provides detailed information of current zoomed view Export to CSV, TXT, BMP, JPG, TIF, PNG, GIF file formats. 3

SPECIFICATIONS Product Identification Product Name Model SITE-LOG LPV-1/LPVB-1 Inputs Connections Pluggable terminal block for seven external channels, excitation controls and alarm outputs. Channels One on-board thermistor temperature (-40 C ~ 70 C, -40 F ~ 158 F). Seven external Voltage DC. Software programmable input range selections for each channel: 0 ~ 20 V, 0 ~ 10 V, 0 ~ 5 V, 0 ~ 2 V Resolution 0.0018% Accuracy Thermistor channel: +/- 0.2 C(0 C ~ 70 C, 32 F ~ 158 F) For LPV-1: ± 0.15% @ 25 C from 0.1V and up ± 0.5% @ 25 C from 0 0.1V For LPVB-1: ± 0.05% FSR @ 25 C for 20V, 10V, 5V channels, ± 0.1% FSR @ 25 C for 2V channel Input Impedance: > 1 MOhms Over-voltage protection +/- 40 VDC Alarms Channel Alarms Two editable alarm thresholds per channel. Alarm Outputs ALARM1 & A2/EXT terminal strips can be configured as alarm outputs. Alarm-On: MOSFET(N-Channel) switch on. Alarm-Off: MOSFET(N-Channel) switch off. Max Power: 200mA @ 24VDC. With purchase of SiteView software, the Site-Log can report alarm status to host PC via USB, Modem or Ethernet Device Server. Alarm-On Delay: Programmable 0-10 minutes delay with 1-minute increments. Alarm Indicator On-board LED lights in red when in alarm condition. On-board Memory 4 Mega bytes (2 Mega measurements). Data Retention Over 20 years. Sampling and Logging Sampling Interval 20 milliseconds [1] to 12 hours user selectable. Logging Mode Stop recording or FIFO when memory is full. Logging Activation Programmable instant, start delay or field push-button activation. Communications Interface USB(USB cable included). AUX(RJ11) for direct TTL level communications. With purchase of DeviceServer Kit, the Site-Log logger can be connected to Ethernet for remote access. Baud Rate Auto-detect baud rate from 2400 to 115200 bps on both USB and AUX ports. Battery Power Built-in 3.6V Lithium Battery. Life Cycle 10 years based on 1 minute sampling interval. Software SiteView [2] Configuration, downloading, plotting, real-time view, custom calibration and custom equation. Software Requirements Computer with 1.0 GHz or faster processor 4

256 MB Memory or higher 1.0 GB of available hard-drive space or higher Windows XP with SP2 or later, Vista, Window 7 At least one USB port or one COM port Physical Material Aluminum enclosure. PCB Treatment Conformal coating. Dimension 88 X 64.2 X 24 mm (3.46 X 2.53 X 0.95 inches) Weight 200g. Mounting Probe/Wall-mount holes for hanging/mounting. Others LED Indicator Tri-Color LED: (can be disabled for power saving) Normal Sampling: green when sampling Alarm: red when sampling Low Battery: amber when sampling. Excitation Control A2/EXT terminal strip can be configured as excitation control output for driving the power of connected devices. Warm-up delay Interval settings: 10 to 240 seconds with 10-second increments. Operating Environment -40 ~ +70 C (-40 F ~ 158 F), 0~95%RH non-condensing. Clock Accuracy ± 1 minute per month. Approvals CE, FCC [1]: Maximum enabled channel: 1 for 20ms interval, 2 for 30ms, 8 for 40ms or bigger interval. [2]: Sold separately. LOGGING CAPACITY TABLE Sampling Interval Enabled Channel Logging Sampling Interval Enabled Channel Logging 1 minute 1 3.98 years 1 second 1 24 days 1 minute 2 727 days 1 second 2 12 days 1 minute 8 181 days 1 second 8 3 days 10 seconds 1 242 days 100 ms 1 58 hours 10 seconds 2 121 days 100 ms 2 29 hours 10 seconds 8 30 days 100 ms 8 7.2 hours 5