Programmable digital indicator

Similar documents
J TB/TW Temperature limiter, temperature monitor

Portable digital microprocessor thermometers with interchangeable probes

JIMAGO 500 Multi-channel Process and Program Controller

Entry-level Paperless Recorder with CompactFlash card and life-cycle data management

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Quick Connect. quick - simple - efficient.

Digital inductive conductivity transmitter

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Digital Pressure Measuring Instrument MDR480

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Auto-tune PID. Temperature Controller BRAINCHILD FEATURES

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

MINI MCR-SL-R-UI(-SP)

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

DS 600. A contact free flux gate based current measurement sensor 600A rms

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

TX OPEN RS232/485 module

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Digital input modules

Vario-Series Accessories

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Pressure transmitter For general industrial applications Model A-10

Digital display DA 48

Wahl C50 Calibrator FEATURES

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

APPLICATION NOTES OF SIGNAL ISOLATORS

Contents. Document information

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Three-phase monitoring relay CM-PFE

Preset Counter signo 721

Duct Humidity Transmitter

Measuring temperature with Resistance Temperature Detectors (RTD) (e.g., Pt100) and thermocouples

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

RM4TG20 three-phase network control relay RM4-T - range V

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

HFE1600 Series 1600W 1U Hot Swap Front End Power Supplies

Analog signal converters CC-E I/I Current / current isolators

How To Use A Flowmeter

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

SINEAX U553 Transducer for AC Voltage

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Temperature Transmitters ZTT series

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

EBS852 (Contrac) Power Electronic Unit

Electric Rotary Actuator - On/Off or programmable control actuator

CPA PC-Programmable Current/Voltage and RTD/Thermocouple Limit Alarm Trips

RRV934. Multi-controller. Synco living

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

NX safety stand-alone

HERZ-Thermal Actuators

TMS TANK MANAGEMENT SYSTEM

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Safety technique. Emergency stop module BO 5988 safemaster

Problem / Solution. The problem:

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

MLC TM Maximum Productivity and Versatility for Control without Compromise!

Power Supplies 3. SDN-P DIN Rail Series

Operating Manual UMB Analogue/Digital Converter ANACON Order Number: 8160.UANA

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

R&S SMZ Frequency Multiplier Specifications

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Instruction Manual Differential Pressure Transmitter

PHOENIX CONTACT Features

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

Differential Charge Amplifier

EGSTON Standard E2xFxWx 12W

VIBROCONTROL Sensitive Machine Monitoring

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

ERMA-Electronic GmbH - Max-Eyth-Str Immendingen - Tel: +49(0)7462/ Fax: +49(0)7462/ Technische Ă„nderungen vorbehalten

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Electronic Pressure Switch EDS 300

THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit , March 2012

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Transcription:

JUMO GmbH & Co. KG Delivery address:mackenrodtstraße, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow, Essex CM 20 2TT, UK Phone: +44 1279 635533 Fax: +44 1279 635262 e-mail: sales@jumo.co.uk Internet: www.jumo.co.uk JUMO PROCESS CONTROL INC. 885 Fox Chase, Suite 103 Coatesville PA 19320, USA Phone: 610-380-8002 1-800-554-JUMO Fax: 610-380-8009 e-mail: info@jumousa.com Internet: www.jumousa.com Data Sheet 70.1520 (95.1520) Page 1/6 Programmable digital indicator Case for flush-panel mounting to DIN 43 700 Bezel size 96mm x 48mm Brief description The 701520 indicator is an instrument which is universally applicable, thanks to the programmable input and display. The configurable analogue input permits the direct connection of resistance thermometers, thermocouples, potentiometers, resistance transmitters or transducers with voltage outputs from 10V to +10V and current outputs from 100 to +100mA. The internal 24V supply supports external 2-wire transmitters. The instrument is configured from a PC through the setup program. The measured value is indicated on a mm high, 4-digit LED display. The sampling rate is three measurements per second. The operating voltage is provided by a primary-switched switchmode power supply, operating off a mains voltage of either 20 53V DC/AC, 0/48 63Hz or 110 240V AC, 48 63Hz. Faston tab connectors, size 6.3mm x 0.8 mm or 2x 2.8mm x 0.8mm, are used to make connections to DIN 46 244/A. Type designation Technical data Type 701520/ Basic type 1. 2. 701520 /... -.. (1) Input Code Universal measurement input, programmable 888 Customized 999 (2) Supply voltage Code 110 240V +10/-15% AC, 48 63Hz 23 20 53V ±0% DC/AC, 0/48 63Hz 22 Ordering example 701520/999-23 Measurement range: 4 20mA, Display: 2.0 12.0pH Standard accessories 1 Installation Instructions B 70.1520.4 2 fixing elements Accessories Setup program on 3.5" diskette PC interface with TTL/RS232 converter Thermocouple input Measurement range Linearisation accuracy (1) Fe-Con L 100 + 900 C ± 0.15% Fe-Con J IEC 50 + 120 C ± 0.15% Cu-Con U 200 + 600 C ± 0.5% Cu-Con T IEC 50 + 400 C ± 0.5% NiCr-Ni K IEC 50 +72 C ± 0.2% NiCr-Con E IEC 50 +1000 C ± 0.2% NiCr-Si-NiSi N IEC 50 +00 C ± 0.2% Pt10Rh-Pt S IEC 50 +1768 C ± 0.25% PtRh-Pt R IEC 50 +1768 C ± 0.2% Pt30Rh-Pt6Rh B IEC 500 +1820 C ± 0.25% MoRe5-MoRe41 0 +1700 C ± 0.2% W3Re-W25Re D 0 +2495 C ± 0.5% W5Re-W26Re C 0 +2320 C ± 0.5% Shortest span Types L, J, U, T, K, E, N: Types S, R, B, MoRe5-MoRe41, D, C: 100 C 500 C Cold junction internal Pt 100 or constant external thermostat Cold junction accuracy ± 1 C can also be programmed in F, 1. The linearisation accuracy refers to the maximum measurement span. The linearisation accuracy is reduced for shorter spans.

JUMO GmbH & Co. KG 36035 Fulda, Germany Data Sheet 70.1520 Page 2/6 Resistance thermometer input Measurement range Linearisation accuracy (1) Pt100 DIN ISO 200 +850 C ± 0.2% Pt100 DIN JIS 200 +649 C ± 0.2% Pt500 200 +850 C ± 0.2% Pt1000 200 +850 C ± 0.2% Ni100 60 +180 C ± 0.2% Ni1000 60 +150 C ± 0.2% Type of connection Shortest measurement span Sensor lead resistance 2-, 3- or 4-wire circuit 15 C max. 30Ω per lead can also be programmed in F, 1. The linearisation accuracy refers to the maximum measurement span. The linearisation accuracy is reduced for shorter spans. Features k configuration from PC through setup program k electrically isolated measurement input (setup is not isolated from the measurement input) k many different inputs possible: - resistance thermometer in 2-/3-/4-wire circuit - thermocouple - resistance transmitter - standard signals - potentiometer in 2-/3-/4-wire circuit k internal cold junction k customized linearisation k offset correction k input filter for interference suppression k 24 V supply for 2-wire transmitter DC voltage input, DC current input Basic measurement span Measurement range Accuracy (1) 1V 1 to +1V ± 0.15% 10V 10 to +10V ± 0.15% Shortest span Potentiometer or resistance transmitter input 10mV 10mA 10 to +10mA ± 0.15% 20mA 200mA Shortest span 0 20mA 100 to +100mA / 0 200mA 0.1mA ± 0.15% ± 0.15% linearisation of non-linear transducers for resistance thermometers and thermocouples; 1. The accuracy refers to the maximum display range (12000digit) Basic measurement span Measurement range Accuracy (1) 20 4000Ω 20 4000Ω ± 0.15% Type of connection Minimum resistance Maximum resistance Sensor lead resistance 2-, 3-, or 4-wire circuit 20Ω 4000Ω max. 30Ω per lead 1. The accuracy refers to the maximum display range (12000digit)

JUMO GmbH & Co. KG 36035 Fulda, Germany Data Sheet 70.1520 Page 3/6 Out-of-range and transducer short-circuit / open-circuit Resistance thermometer/ Thermocouple/ Voltage Current resistance transmitter potentiometer Out-of-range (below range) (1) recognised recognised recognised recognised Out-of-range (above range) (1) recognised recognised recognised recognised Transducer short-circuit (1) recognised not recognised not recognised 0 20mA not recognised; 4 20mA recognised Transducer open-circuit (1) recognised (2) recognised recognised 0 20mA up to ±1V not recognised; 4 20mA recognised 1. Indicated by flashing LED 2. Lead break in a 4-wire circuit is only recognised on terminals and Display Type Height Display range Transfer characteristic (configurable) Decimal places (configurable) 2nd order digital filter Customized linearisation Supply voltage Supply voltage Electrical safety 1. DC/AC also known as UC Case LED; 7-segment; 4 digit mm 1999 to +9999digit resistance thermometer, linear with temperature, thermocouple linearised to customer specification voltage, current linear, linearised for resistance thermometer, linearised for thermocouple, linearised to customer specification resistance transmitter linear, linearised to customer specification potentiometer linear, linearised to customer specification thermocouple none or one resistance thermometer none, one or two voltage, current, none, one, two or three resistance transmitter, potentiometer 0 100s configurable max. 61 calibration points, linear, quadratic, or cubic interpolation 110 240V +10/-15% AC, 48 63Hz or 20 53V DC/AC, 0/48 63Hz, (1) 5.5VA power consumption to EN 61 010; pollution degree 2; overvoltage category II Environmental influences Operating temp. range 0 to 50 C Storage temp. range 20 to +70 C Temperature error resistance thermometer 0.02% / 10 C (1) thermocouple 0.05% / 10 C (1) in addition to the cold junction error voltage, current, 0.001% / 10 C (2) resistance transmitter, potentiometer Climatic conditions rel. humidity 75%, no condensation; pollution degree 2 EMC EN 61 326 - Interference emission Class B - Immunity to interference industrial requirements IP protection front IP54 back IP20 1. Refers to the maximum measurement span. 2. The accuracy refers to the maximum display range (12000digit). Material Front bezel size Mounting depth Mounting position Electrical connection (to DIN 46 244/A) Weight Polycarbonate 96mm x 48mm 107mm any faston tabs 6.3mm x 0.8mm, faston tabs 2.8mm x 0.8mm 250g

JUMO GmbH & Co. KG 36035 Fulda, Germany Data Sheet 70.1520 Page 4/6 Setup program The program is used to carry out the configuration of the instrument and to transfer the setup data to and from the instrument. The setup data can be output to a printer in the form of a list and saved to or loaded from any available data storage media. The connection between the PC and the instrument, via the PC interface cable, is only required for the transfer of setup data. It is not necessary to make a connection to the instrument while processing the data (loading from or saving to data media, editing). The setup interface in the instrument can be accessed after levering off the front panel. The program can be operated through the 5 items in the menu bar, or through the symbol bar which is arranged beneath it. File To open or save the configuration data, and for printing them out. In addition, selections can be made for the display (menu or symbol bar), for the interface transmission, and for the language used by the operator. Edit For the input of the application-specific parameters: measurement input, mains supply frequency, TAG-number (measuring station/instrument number), linearisation table, information text. Display of a temperature, measured by a NiCr-Ni thermocouple and a non-linearised 2- wire transmitter, 4 20mA, 0 900 C linear with thermocouple voltage NiCr-Ni. Setup data transfer To transfer the parameters from the PC to the instrument, or to read them out from the instrument. Windows To arrange the windows when several configuration files are open at the same time. Each one of these files defines an instrument. Individual parameters can be copied from one open file to another. Help Provides information on operating the program and the parameters which can be set. Customized linearisation for the filling level of a flat tank (using a pressure sensor).

JUMO GmbH & Co. KG 36035 Fulda, Germany Data Sheet 70.1520 Page 5/6 Dimensions

JUMO GmbH & Co. KG 36035 Fulda, Germany Data Sheet 70.1520 Page 6/6 Connection diagram Connection for Terminals Symbol Supply voltage as on label L1 Line L+ N Neutral L- TE Technical earth Output Voltage supply 1+ 24V/45mA 2- Supply for 2-wire transmitter Measurement input Voltage + 1V 17+ 10V Current 18+ 10mA 15+ 200mA Thermocouple + Resistance thermometer 2-wire circuit: Lead resistance R L 30Ω R L is entered in the setup program 3-wire circuit: 4-wire circuit: 15 Resistance sensor A = start S = slider E = end Potentiometer 2-wire circuit: Lead resistance R L 30Ω R L is entered in the setup program 3-wire circuit: 4-wire circuit: 15