GENERAC QUIETSOURCE SERIES STANDBY GENERATORS

Similar documents
Standby Generators FEATURES. Standby Generators Liquid-Cooled Gas Engine. Standby Generators INCLUDES:

Diesel Engine Driven Generators Page 1 of 6

Spark-ignited generator set

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 80 kw 100 kva 60 Hz

20 kw. 20 kw ISO. Synergy Variable Speed Residential Standby Generator Air-Cooled Gas Engine FEATURES

8/11 kw. 8/11 kw. GUARDIAN SERIES Residential Standby Generators Air-Cooled Gas Engine FEATURES

16/20/22 kw CENTURION SERIES

16/20/22 kw. 16/20/22 kw. GUARDIAN SERIES Residential Standby Generators Air-Cooled Gas Engine

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

STANDBY 800 ekw 1000kVA 60 Hz 1800rpm 480Volts

DIESEL GENERATOR SETS

DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET

Diesel Generating Set

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

STANDBY 150 ekw 188 kva PRIME 135 ekw 169 kva

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 10 kw 12.

Magnum Mobile Generator MMG55 Specifications

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

DIESEL FEATURES GENERATOR SET. FUEL/EMISSIONS STRATEGY Low fuel consumption

SG035. Industrial Gaseous Generator Set. SG035 35kW. primary codes and standards. Standby Power Rating 44kVA 35kW 60Hz

How To Control A Power Command Powerplant

Frequently Asked Questions Generators

C18 ACERT Fire Pump Tier bkw/ rpm

residential & commercial Generators

New 27 hp 2 Cylinder Liquid-Cooled Engine

GEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer

How To Use A Cat Diesel Engine

Diesel Generator Set Model DGDK 60 Hz

Technical Specification. Generating Set with Waukesha engine burning natural gas

RENTAL XQ230 SOUND ATTENUATED. DUAL VOLTAGE 50/60 Hz FEATURES

1100 Series 1104C-44TAG2 Diesel Engine ElectropaK rpm

XQ20 RENTAL. 60 Hz. Voltage kw (kva) kw (kva) 208/120V 3 PH 20 (25) 18 (22.5) 480/277V 3 PH 20 (25) 18 (22.5) 240/120V 1 PH 17 (17) 16 (16)

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

Centro-Matic Automatic Lubrication Systems System Controls

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

Diesel Generator Set Model DFHC 60 Hz

Annex-A TECHNICAL SPECIFICATION

NATURAL GAS CONTINUOUS 725 ekw 906 kva 745 ekw 931 kva 770 ekw 963 kva 50 HZ 1500 RPM 400 VOLTS

AGP15 Perkins Series Gen Set Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

3516 Industrial Engine

DIESEL GENERATOR SET FEATURES. FUEL/EMISSIONS STRATEGY Low Fuel consumption

912. The engine for construction equipment.

Marine Generating Sets 3.7 to 50 kva

1 Air-to-Air AfterCooling. 2 Engine Only. Capacity will vary with radiator size and use. of cab heater.

STANDBY PERMANENT MOUNT SERIES GENERATOR

Diesel Generator Set Model DFMB 60 Hz

3304B. Marine Auxiliary Engine SPECIFICATIONS STANDARD EQUIPMENT ACCESSORY EQUIPMENT PERFORMANCE DATA. 56 bkw (75 bhp) rpm

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

STANDBY 3200 ekw 4000 kva 50 Hz 1500 rpm Volts

Auxiliary Power Unit (APU) for Military Vehicles

LOAD BANK TESTING PROCEDURE

Signature and ISX CM870 Electronics

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 480 Volts

It s storming outside. Neighbors have no power. For you, dinner s on in 15.

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

STANDBY 2500 ekw 3125 kva 60 Hz 1800 rpm 480 Volts

Cat Electronic Technician 2015A v1.0 Product Status Report 4/20/2016 2:49 PM

Basic Nameplate Information

Cat Electronic Technician 2015C v1.0 Product Status Report 2/16/2016 9:19 AM

C18 Diesel Oilfield Generator Set

STANDBY 1500 ekw 1875 kva 60 Hz 1800 rpm 480 Volts

POWER GENERATION.

GEP150 (3-Phase) 50 HZ 60 HZ. 150 kva / 120 kw FEATURES. Exclusively from your Caterpillar dealer

Cat Electronic Technician 2015A v1.0 Product Status Report 6/3/2015 4:41 PM

WHOLESALE DIRECT INC WEST 65TH STREET

IGSA POWER GENERATION SYSTEMS

NATURAL GAS CONTINUOUS 1000 ekw 1250 kva 50 HZ 1500 RPM 400 Volts

Phone: Fax: Web: info@clrwtr.com

The Yachtmans Choice...

CorePower Home Standby Generator

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

Owner s Manual. For Automatic Transfer Switch Amp, Service Entrance/Non-Service Entrance

MovinCool Office Pro Series. The Portable Spot Cooling Solution

Rental. C18-20 XQ600 MULTI-VOLTAGE SOUND ATTENUATED POWER MODULE 60 Hz FEATURES

GE Oil & Gas. Texsteam * Pumps: precise chemical injection pumping

PowerCommand 3201 digital generator set control

Explosion-Proof Electric Unit Heaters

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Power kva Power kw Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 1

APS100 Rental Generator Set Specification

Electric Coolant Pumps. Always at the Correct Temperature

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Propane-Fueled Microturbine: Case Study

32VFD Variable Frequency Drives for Centrifugal Chillers

Atlas Copco Generators

(ui. C) Listed by Underwriters' Laboratories of Canada. 6BTA5.9 F1 LISTED AGENCY RATINGS

300 Series PA Pump and Cooler Assemblies

PSR The compact range Description

PM734F - Technical Data Sheet Winding 28

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

PI144K - Winding 311 APPROVED DOCUMENT. Technical Data Sheet. Generator Solutions AS

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

Model #: SMART2200CRMXL

Transcription:

GENERAC QUIETSOURCE SERIES STANDBY GENERATORS 27 kw Includes: Generac Naturally Aspirated Gaseous Fueled 2.4L Engine Liquid-Cooled Engine Generator Sets Standby Power Rating Model (Gray) - 27 kw 60Hz Two Line LCD Tri-lingual Digital Nexus Controller Isochronous Electronic Governor Sound Attenuated Enclosure Closed Coolant Recovery System Smart Battery Charger UV/Ozone Resistant Hoses ±1% Voltage Regulation Natural Gas or LP Operation 2 Year Limited Warranty UL 2200 Listed Meets EPA Emission Regulations CA/MA emissions Compliant FEATURES INNOVATIVE DESIGN & PROTO TESTING are key components of GENERAC S success in IMPROVING POWER BY DESIGN. But it doesn t stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that these systems will provide superior performance. TEST CRITERIA: PROTO TESTED SYSTEM TORSIONAL TESTED NEMA MG1-22 EVALUATION MOTOR STARTING ABILITY SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge loads to the engine. An unequalled ±1% voltage regulation. SINGLE SOURCE SERVICE RESPONSE from Generac s extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. GENERAC TRANSFER SWITCHES. Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility.

Application & Engineering Data GENERATOR SPECIFICATIONS Synchronous ROTOR INSULATION Class H STATOR INSULATION Class H TELEPHONE INTERFERENCE FACTOR (TIF) <50 ALTERNATOR OUTPUT LEADS 3 PHASE 4 wire BEARINGS Sealed Ball COUPLING Flexible Disc LOAD CAPACITY (STANDBY RATING) 27 kw EXCITATION SYSTEM Direct VOLTAGE REGULATION Electronic SENSING Single Phase REGULATION ± 1% GENERATOR FEATURES Revolving field heavy duty generator Directly connected to the engine Operating temperature rise 120 C above a 40 C ambient Insulation is Class H rated at 150 C rise All models are fully prototyped tested ENCLOSURE FEATURES Aluminum weather protective enclosure Enclosed critical grade muffler Small, compact, attractive SAE Ensures protection against mother nature. Electrostatically applied textured epoxy paint for added durability. Quiet, critical grade muffler is mounted inside the unit to prevent injuries. Makes for an easy, eye appealing installation. Sound attenuated enclosure ensures quiet operation. ENGINE SPECIFICATIONS MAKE Generac MODEL Inline 4 CYLINDERS 4 DISPLACEMENT 2.4 Liter BORE 3.41 STROKE 3.94 COMPRESSION RATIO 9.5:1 INTAKE AIR SYSTEM Naturally Aspirated LIFTER Hydraulic GOVERNOR SPECIFICATIONS Electronic FREQUENCY REGULATION Isochronous STEADY STATE REGULATION ± 0.% ENGINE LUBRICATION SYSTEM OIL PUMP Gear OIL FILTER Full flow spin-on cartridge CRANKCASE CAPACITY 4 Quarts ENGINE COOLING SYSTEM Closed WATER PUMP Belt driven FAN SPEED 1980 FAN DIAMETER 18.1 inches FAN MODE Pusher FUEL SYSTEM FUEL Natural gas, propane vapor CARBURETOR Down Draft SECONDARY FUEL REGULATOR FUEL SHUT OFF SOLENOID OPERATING FUEL PRESSURE 5-14 H 2 O ELECTRICAL SYSTEM BATTERY CHARGE ALTERNATOR STATIC BATTERY CHARGER RECOMMENDED BATTERY SYSTEM VOLTAGE 12V 30 Amp 2 Amp Group 26, 5CCA 12 Volts Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, ISO3046 and DIN6271). (All ratings in accordance with BS5514, ISO3046, ISO8528, SAE J1349 and DIN6271).

Generac QuietSource Series Standby Generator - 27 kw OPERATING DATA KW RATING (LP/NG) 27/ ENGINE SIZE 2.4 Liter Inline 4 GENERATOR OUTPUT VOLTAGE/KW - 60Hz kw LPG AMP kw Nat. Gas AMP CB Size (Both) 120/240V, 1-phase, 1.0 pf 120/208V, 3-phase, 0.8 pf 120/240V, 3-phase, 0.8 pf ENGINE FUEL CONSUMPTION (Natural Gas) (Propane) Exercise cycle % of rated load 50% of rated load 75% of rated load 100% of rated load* For Btu content, multiply ft 3 /hr x 20 (LP) or ft 3 /hr x 1000 (NG) ENGINE COOLING 27 27 27 Natural Gas (ft 3 /hr.) 42 108 197 287 359 112 94 81 104 87 75 Propane (gal/hr.) cu ft/hr 0.44 16 1.2 44 2.1 78 3.1 114 3.9 143 1 100 90 Air flow (inlet air including alternator and combustion air) System coolant capacity Heat rejection to coolant Max. operating air temp. on radiator Max. ambient temperature COMBUSTION AIR REQUIREMENTS ft 3 /min. US gal. BTU/hr. C ( F) C ( F) 2,400 3 105,000 60 (150) 50 (140) Flow at rated power 60 Hz cfm 68 SOUND EMISSIONS IN DBA Exercising at 7 meters Normal operation at 7 meters EXHAUST Exhaust flow at rated output 60 Hz cfm Exhaust temp. at muffler outlet F ENGINE PARAMETERS 61 70 180 900 Rated synchronous RPM 60 Hz 1800 POWER ADJUSTMENT FOR AMBIENT CONDITIONS Temperature Deration Altitude Deration 3% for every 10 C above - C 1.65% for every 10 F above - F 1% for every 100 m above - m 3% for every 1000 ft. above - ft. 77 183 600 Refer to "Emissions Data Sheets" for maximum fuel flow for EPA and SCAQMD permitting purposes. RATING: All three phases units are rated at 0.8 power factor. All single phase units are rated at 1.0 power factor. STANDBY RATING: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-3046-1. Design and specifications are subject to change without notice. KW rating is based on LPG Fuel and may derate with natural gas.

0 GROUND 15B +12V TRANSFER AIR 1 AIR 2 PRIORITY 1 PRIORITY 2 PRIORITY 3 PRIORITY 4 NOTE WIRE ORIENTATION T1 NEUTRAL 1 2 3 4 0C4449A-T INTERCONNECTIONS QT SERIES ENGINE GENERATOR CONNECTION PANEL UTILITY SUPPLY FROM SERVICE DISCONNECT RTS TRANSFER SWITCH NOTE: MATCH WIRE NUMBERS TO TERMINAL NUMBERS T1/LINE NEU ON CUSTOMER SUPPLIED NEUTRAL WIRE LOAD SHED MODULE UTILITY (C1 & VR1) 183 178 T1 0 E1 NEUT E2 NEUTRAL BLOCK 0 CUSTOMER CONNECTIONS 0 DC COMMON +12VDC TRANSFER WARNING 48850-T T1 STANDBY (C2 & VR2) E1 T1 E2 T2 T1 E1 E2 T2 GROUND GROUND NEUTRAL BLOCK NOTE: POWER LEADS AND TRANSFER SWITCH LEADS TO BE RUN IN TWO DIFFERENT CONDUITS. LIQUID-COOLED INSTALLATION CUSTOMER LOAD (DISTRIBUTION PANEL) NEXUS CONTROL FEATURES 2-Line Plain Text LCD Display Simple user interface for ease of operation Mode Switch -Auto Automatic Start on Utility failure. 7 day exerciser -Off Stops unit. Power is removed. Control and charger still operate. -Manual/Test (start) Start with starter control, unit stays on. If utility fails, transfer to load takes place. Programmable start delay between 10-30 seconds Engine Start Sequence Cyclic cranking: 16 sec. on, 7 rest (90 sec. maximum duration) Engine Warm-up 5 seconds Engine Cool-Down 1 minute Starter Lock-out Starter cannot re-engage until 5 sec. after engine has stopped. Smart Battery Charger Automatic Voltage Regulation with Over and Under Voltage Protection Automatic Low Oil Pressure Shutdown Overspeed Shutdown, 72Hz High Temperature Shutdown Overcrank Protection Safety Fused Failure to Transfer Protection Low Battery Protection 50 Event Run Log Future Set Capable Exerciser Incorrect Wiring Protection Internal Fault Protection Common External Fault Capability Governor Failure Protection *Single and three phase connections may vary, refer to the owner s manual for specific connection information.

INSTALLATION LAYOUT

AVAILABLE ACCESSORIES Model # Product Description 5630 Cold Weather Kit If the temperature regularly falls below 32 F, install a cold weather kit to maintain optimal battery temperature. Kit consists of battery warmer with thermostat built into the wrap. 5621 Auxiliary Transfer Switch Contact Kit The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load you may not need. 5616 Extreme Cold Weather Kit Recommended where the temperature regularly falls below 32 F for extended periods of time. For liquid cooled units only. 5651 Base Plug Kit Add base plugs to the base of the generator to keep out debris. 5704 Paint Kit Medium Grey Kit 5656 Scheduled Maintenance Kit The Liquid-Cooled Scheduled Maintenance Kits offer all the hardware necessary to perform a complete maintenance on Generac liquidcooled generators. 5928 Nexus Wireless Remote Completely wireless and battery powered, Generac's Nexus wireless remote monitor provides you with instant status information without ever leaving the house. 5951 5937 Advanced Nexus Wireless Remote DLM Load Control Module (50 Amps) Remotely control generator functions with the advanced model's LCD display. In addition to remote testing of the generator, set the excercise cycle and maintenance interval reminders. DLM Modules are used in conjunction with the Nexus Smart Switch to increase its load management capabilities. It gives the Nexus Smart Switch additional load management flexibility not found in any other transfer switch. Generac Power Systems, Inc. S45 W29290 HWY. 59, Waukesha, WI 53189 generac.com 2012 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 0187720SBY-J / Printed in U.S.A. 06/27/12