ELECTRONIC MANUAL VOLTAGE CONTROL Model: MVC 300. Part Number:

Similar documents
SX460. Generator Automatic Voltage Regulator Operation Manual

Single Phase Soft Starter

Automatic Voltage Regulator User s Manual

Advantium 2 Plus Alarm

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Operation Manual. 150 Watt Halogen Light Source for Endoscopy Model # s ESS-150, ESS-150A ESS-220, ESS-220A

Digi-Motor Installation Guide

OPL BASIC. Dosing System for Professional Laundry machines. Contents

CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

Operator: Save these instructions for future use!

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

Instruction Manual. This manual covers models: 8-125E 60-18E 20-50E 80-13E 33-33E 150-7E 40-25E E 50-20E E

Service Information CALIBRATION PROCEDURE AND TROUBLESHOOTING FOR LINEAR GOVERNOR CONTROLLERS NOTE

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Welcome to Linear Controls Quarterly Training

MS4000/MS4000U Mini-Siren

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Model SRMD Setra Remote Monitoring Display

REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN (574) FAX (574) ELKHART BRASS MFG. CO., INC.

JAD SERIES OWNER S MANUAL. JAD Channel Full Range Class D Amplifier

Bubble King. User Manual

JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator

AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER

RIGOL. Quick Guide. DS1000CA Series Oscilloscope. Aug RIGOL Technologies, Inc.

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

VLT Series 300 Watt True Sine Wave Inverter

INSTALLATION & SERVICE MANUAL. Display Panel

Single-Phase AC Synchronous Generator

Pow-R-Con Multi Function Control

VK-250 WARRANTY REGISTRATION FORM

Technical Instructions Document No P25 ET September 28, ET 141 High Limit Control Thermostat. Description.

Servo Info and Centering

PT100 Portable TAP. User Guide. Revision 1.0

ALTERNATOR & REGULATOR - HITACHI

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

RC NETWORKS SALES GUIDE

Applied Electronics. Commercial Dimming System UPDATE NOTICE

PANCAKE CAPACITOR GENERATOR Installation, Operation and Maintenance Manual

OWNER'S MANUAL. AtlasSound.com PA601 COMMERCIAL AMPLIFIER. PA601 Commercial Amplifier. Power. Master

Multi-Pitch Pitching Machine USER MANUAL

Replacing the vacuum tube

Norcold Repair Guide Models 442, 443, 452, 453, 462, 463, 482, 483

TROUBLESHOOTING GUIDE

Industrial Ringdown/Autodialer Telephone SCR Series

TOA 900 SERIES II MIXER POWER AMPLIFIER

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Dehumidifier Users manual. For Models: DH45S DH65S

3.0 CHARACTERISTICS. AR Auxiliary Relay High Speed, High Threshold C

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

Rutland 913 Windcharger Fault Finding Guide

HP UPS R1500 Generation 3

Pro Logic Version Diagnostics Manual

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

ST Series POWER SUPPLIES USER INSTRUCTIONS

INSTRUCTIONS FOR THE INSTALLATION AND OPERATION OF ACTIVATOR II

ABB ! CAUTION. Type COQ Negative Sequence Generator Relay. (50/60 Hertz) J. Instruction Leaflet

Installation and Operation Guide for PD4100 Series Power Control Centers

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

VARI-DRIVE NEMA1 / IP20 SCR Variable Speed DC Motor Controls

BATTERY CHARGER RLD USER'S MANUAL

Oil and Coolant Circulating Heating System. Model - OCSM

DLP-PU/E Instruction Manual

KBIC Solid State SCR DC Motor Speed Controls See table 2 page 4 for KBIC models covered by this manual

SIMPLE ELECTRONIC IGNITION WIRE DIAGRAM THERMOSTAT (3) PV PILOT BURNER/IGNITOR - SENSOR Q345A (9) SPARK (4) GND (BURNER) CHASSIS GND

LED MOTION ACTIVATED FLOOD LIGHT

Installation and Operation Guide for PD4000 Series Power Control Center

Electronically Controlled Air Suspension (ECAS) for Trucks

Power Supplies 3. SDN-P DIN Rail Series

DC LOAD TESTING Gian Trento June 18 th, 2004

Telefon (+45) Telefax (+45) Installation and operating manual

Type SA-1 Generator Differential Relay

HM-W536 Install Guide

1000-LB. TRAILER JACK OWNER S MANUAL

Model 2300DR Installation Guide

Installation and Operating Manual

INFRARED QUARTZ WALL HEATER

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

LiteAide OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS

CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page Phase Simplex Page 8-13

TIG INVERTER INSTRUCTION MANUAL

R448 & R448 V50 A.V.R.

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

ST Style Generator. Owners/Operators Manual

ELECTRONICS G H I J K L M

5-Slot Housing and FrameSaver 9000 Series Access Carrier AC Power Supply Installation Instructions

Water Leak Detection System

OWNER'S MANUAL. Model CUL AC Power Inverter/Charger System OM/A96283 REV. A

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

WOO AUDIO WA3. Stereo Headphone Amplifier. Single-Ended OTL, Class A Vacuum Tube Headphone & Pre Amplifier. Owner s Manual

POWER TRIM 5 F AUTO TRIM AND AUTO TRIM

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

3000W Power Inverter

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

SERVICE BULLETIN No.1103

Transcription:

ELECTRONIC MANUAL VOLTAGE CONTROL Model: MVC 300 Part Number: 9 1210 00 106 Publication Number: 9 1210 00 993 Date: July, 1993 Revision F: July, 1996

WARNING To prevent personal injury or equipment damage, only qualified technicians/operators should install, operate, or service this device. CAUTION Meggers and high potential test equipment should be used with extreme care. Incorrect use of such equipment could damage components contained in the device. CONFIDENTIAL INFORMATION of Basler Electric Company, Highland, IL. It is loaned for confidential use. Subject to return on request and with the mutual understanding that it will not be used in any manner detrimental to the interests of Basler Electric Company. It is not the intention of this manual to cover all details and variations in equipment, nor does it provide data for every possible contingency regarding installation or operation. The availability and design of all features and options are subject to change without notice. Should further information be required, call Basler Electric Company, Highland, IL. Rev ECA E 15588 F 15760

SECTION 1 GENERAL INFORMATION 1-1. PURPOSE The Electronic Manual Voltage Control (MVC-300) is used as a back-up control device to provide manual voltage control in case of voltage regulator failure. The unit can be mounted on a control panel in ground vehicles, stationary equipment or shipboard locations. 1-2. OVERALL DESCRIPTION The MVC-300 is a solid-state device enclosed in a metallic dark grey chassis and designed to be 'through-the-panel' mounted with controls accessible to an operator from the front of the panel. A terminal strip located on the rear of the device facilitates installation and operation. A MANUAL VOLTAGE ADJUST control and an AUTO-OFF-MANUAL voltage control mode switch are provided on the front panel. 1-3. SPECIFICATIONS Table 1-1 provides the electrical and physical specifications of the MVC 300. Input Power: Output Adjustment Range: 120 Vac Input: 240 Vac Input: Watts Dissipated: Minimum Residual Voltage for Buildup: Ambient Operating Temperature: Ambient Storage Temperature: Shock Vibration: Weight: Table 1-1. Specifications. 120 Vac, + 10%Single-Phase, 50-320 Hz. 240 Vac, + 10%Single-Phase, 50-320 Hz. 1 to 32 Vdc or 1 to 63 Vdc. 1 to 63 Vdc or 1 to 125 Vdc. 30 W maximum. 6 Vac. -40 F (-40 C) to +158 F (+70 C) -85 F (-65 C) to +212 F (+100 C) Withstands up to 15 G's in each of three mutually perpendicular axes. Withstands the following: 5-27 Hz @ 1.3 G's, 27-52 Hz @ 0.036" double amplitude, 52-500 Hz @ 5 G's. 3.0 lbs. (1.36 kg) net, 5 lbs. (2.26 kg) shipping. 1-1

SECTION 2 PRINCIPLES OF OPERATION 2-1. GENERAL a. The Electronic Manual Voltage Control (MVC-300) is a phase-controlled, silicon-controlled, rectifier (SCR) bridge. By adjusting the front panel MANUAL VOLTAGE ADJUST control, the firing angle of the SCR change providing an adjustable voltage level to the exciter field. b. During start-up, the build-up circuit holds the SCRs power bridge at maximum output. When the voltage has built-up to approximately 30 Vac, the internal build-up circuit relinquishes control to the MANUAL VOLTAGE ADJUST control on the front panel. c. The AUTO-OFF-MAN voltage control mode switch allows transfer from the voltage regulator to the Manual Voltage Control or from Manual Voltage Control to voltage regulator. A free wheeling diode remains connected to the field to allow safe switching without arcing. d. The MVC-300 is designed to operate from 120 or 240 Volt nominal sources without any electrical changes such as tap selection or terminal connections. Taps are provided to select 32, 63, or 125 volt maximum outputs. 2-1

SECTION 3 INSTALLATION AND OPERATION 3-1. INSTALLATION a. The MVC-300 is designed for 'through-the-panel' mounting. Refer to the drilling template of Figure 3-1 and to the outline drawing Figure 3-2. The front panel of the MVC-300 is detachable by removal of the knob and locking nut from the MANUAL VOLTAGE ADJUST control and the four corner screws. The MVC-300 can be installed in any position without affecting its operating characteristics, however, it is preferable that the device be mounted vertically to improve ventilation. The MANUAL VOLTAGE ADJUST control can be removed and installed remotely by using terminals 14, 15 and 16 or a Basler motor operated control (MOC 2) with a 10 k ohm control element can be connected to terminal 14, 15, and 16. See Figure 3-3 Interconnection Diagram. It is imperative that the MVC-300 be connected to provide an output which corresponds to the voltage regulator ratings in order to prevent damage to the MVC-300 or the regulator. When the MVC-300 and voltage regulator are properly matched, the MVC-300 provides smooth control of the generator output voltage in the manual mode. b. The chart (Table 3-1) is used to determine the appropriate input voltage and to select the output voltage. Based on voltage regulator model, from column 1, the proper voltage input rating from column 3 is selected and connections are made between the generator and terminals 23 and 24 which will supply the specified voltage. The MVC-300 has a wire jumper connected from the printed circuit board of the MVC-300 to the barrier strip. Column 4 indicates the correct terminal for this jumper connection. 3-1

Figure 3-1. Panel Drilling Template 3-2

Figure 3-2. MVC 300 Outline Drawing. 3-3

Figure 3-3. MVC 300 Interconnection Diagram, Typical. 3-4

Voltage Regulator Model Table 3-1. Voltage Selection Chart. Voltage Regulator Rating MVC Input Voltage Voltage Selection Terminal KR7F,KR7FF, SR8A,SR8F 125 V @ 7 A or less 240 Vac 125 SR4A,SR4F, 63 V @ 7 A or less 120 Vac 63 KR4F,KR4FF XR2001,XR2004 63 V @ 7 A or less 240 Vac 63 KR2F,KR2FF 32 V @ 7 A or less 120 Vac 32 APR63-5 63 V @ 7 A or less 240 Vac 63 APR125-5 125 V @ 7 A or less 240 Vac 125 3-2. OPERATION a. With the AUTO-OFF-MANUAL voltage control mode switch placed in MANUAL, the automatic voltage regulator is removed from the line and generator output voltage is controlled manually by the MANUAL VOLTAGE ADJUST control. When placed in the AUTOMATIC position, the generator output voltage is controlled by the automatic voltage regulator. Complete excitation shutdown occurs when the voltage control mode switch is placed in the OFF position. CAUTION With the voltage control mode switch in either MANUAL or OFF position, some terminals of the regulator are connected to the generator and present a potential shock hazard. No attempt should be made to remove or troubleshoot the regulator while the generator is running. b. Start the prime mover following the manufacturer's procedure, set the MANUAL VOLTAGE ADJUST control to minimum (counter-clockwise), and place the AUTOMATIC-OFF-MANUAL voltage control mode switch in MANUAL position. Note that the voltage may be unstable (hunting) if the MANUAL VOLTAGE ADJUST control is set below 30 Vac. c. Allow the generator to build-up and slowly increase the generator output voltage with the MANU- AL VOLTAGE ADJUST control until the generator output voltage reaches the desired level. 3-3. OPERATIONAL TEST To verify that the MVC-300 is operating properly, use the following procedure and the connections of Figure 3-4 for a bench test. Notice that the voltage regulator is not necessary for this test. (1) With no power applied to the MVC-300 and all connections to the voltage regulator removed, place the AUTO-OFF-MANUAL voltage control mode switch to the MANUAL position. (2) Connect a 120 Vac 100 Watt light bulb to terminals F+ and F- of the MVC-300, and connect the jumper to Terminal 63. 3-5

Figure 3-4. Operational Test Set-Up Diagram. (3) With the MANUAL VOLTAGE ADJUST control fully counter-clockwise (CCW) apply a source of 120 Vac to Terminals 23 and 24 of the MVC-300. Slowly rotate the MANUAL VOLTAGE ADJUST control clockwise (CW) and observe that the brightness of the light bulb increases proportionally until it reaches full brightness. (4) Rotate the MANUAL VOLTAGE ADJUST control fully counter-clockwise (CCW). Remove the 120 Vac source from Terminals 23 and 24 and select 32 volt operation by moving the jumper to Terminal 32. Apply the 120 Vac source to Terminals 23 and 24 of the MVC and observe that the brightness of the light bulb increases as the MANUAL VOLTAGE ADJUST control is moved clockwise (CW). Notice that the brightness of the bulb is approximately half of its previous brightness with the jumper connected to this terminal. 3-6

SECTION 4 MAINTENANCE AND TROUBLESHOOTING 4-1. PREVENTIVE MAINTENAN CE A periodic inspection should be made of the unit to insure it is clean and free from accumulations of dust and moisture. Verify that all terminal connections of the MVC-300 and the voltage regulator are tight. 4-2. TROUBLESHOOTING In the event of failure/defective operation of the unit, Table 4-2 provides information to determine the probable cause of the malfunction and the solution. Refer to Paragraph 3-3 and to Figure 3-4 for the bench test procedure. 4-3. RECOMMENDED SPARE PARTS Due to a protective coating, repair/replacement of individual components on the printed circuit board assembly should not be attempted and the complete replacement of the board is recommended. When ordering replacement parts from Basler Electric always specify the part number, the quantity and the description of the item. Reference Designator Table 4-1. Replacement Parts List. Part Number Quantity Description ---------------- 9 1210 01 103 1 Printed Circuit Board Assembly F1,F2 04592 2 Fuse, 10 A, 250 V 4-1

Table 4-2. Troubleshooting. MALFUNCTION TEST OR INSPECTION CORRECTIVE ACTION MVC 300 APPEARS TO BE DEFECTIVE. Step 1. Verify that wiring is correct and proper in accordance with Figure 3-3. If wiring is defective or incorrect, repair as needed. If wiring is not defective or incorrect, proceed to Step 2. Step 2. Check that the AUTO-OFF-MAN front panel switch turns off the excitation. If the excitation does not turn off, replace the MVC 300. If the excitation shuts down, proceed to Step 3. Step 3. With the AUTO-OFF-MAN front panel switch in MANUAL, verify that the generator output voltage builds up. If the generator output voltage builds up, proceed to Step 6. If the generator output voltage does not build up, proceed to Step 4. Step 4. Verify that internal fuses F1 and F2 are good. If either fuse is defective or blown, replace fuse and proceed to Step 5. If both fuses are not defective or blown, replace the MVC 300. Step 5. Verify that the generator output voltage builds-up. If the generator output voltage does not build-up, replace the MVC 300. If the generator output voltage builds-up, proceed to Step 6. Step 6. Verify that the generator output can be controlled by the MVC 300 front panel potentiometer. If the generator output voltage cannot be controlled by the MVC 300, replace the MVC 300. If the generator output voltage can be controlled by the MVC 300, proceed to Step 7. Step 7. Verify that the generator works in the front panel switch AUTO position. If the generator fails to operate with the front panel switch in the AUTO position, troubleshoot the voltage regulator. 4-2