MEGAFLO SHRU Installation Instructions Shower Heat Recovery Unit

Similar documents
Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

E-gas Instant Gas Water Heaters

SF15K SF05KSS, SF10KSS

Chill 4 Hole Bath Shower Mixer

Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.

Artisan Thermostatic basin mixer. Fitting Instructions & Contents List

Home comfort: water heating

Itho Products for Hot and Boiling water. product-

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

Assembly and instructions

Artisan Thermostatic bath shower mixer. Fitting Instructions & Contents List

Coolflo Safe Touch Shower Mixing Valve ST20015CP

Morco House Riverview Road Beverley HU17 0LD

OWNER & INSTALLER MANUAL AND WARRANTY INFORMATION.

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

INSTALLATION INSTRUCTIONS MK-8704

Operators manual Basic water heater

User's Instructions. Alpha HE CB25/33 and HE SY25

Design Utility Lever Thermostatic Bath Shower Mixer

Providing Temperature. Regulated Warm Water. to your Sanicare. Hand Spray Bidet

Visage. Digital. Exposed with adjustable height head. Visage Digital exposed installation instuctions page 1

INFRARED QUARTZ WALL HEATER

Please also see 10 golden rules for correct Saniflo installation on

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

Elson Coral E. Open Vented Thermal Store providing mains pressure hot water heated by electricity. Installation, Servicing and User's Instructions

REGISTRATION EXAMINATION, JUNE 2009 PLUMBING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

INSTALLATION INSTRUCTIONS BL-8704

Electronically Controlled Instantaneous Water Heaters Models: DEX & DBX

Hot water supply, distribution and use

I N S T ALLATION INSTRUCTIONS & HOME OWNERS MANUAL IMPORTANT SAFETY INFORMATION

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Troubleshoot resources for homeowner

Electric Instantaneous. Water Heaters. Service manual

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

HEAVY DUTY STORAGE GAS

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

your water pressure explained

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Baxi Combi Instant 80e & 105e. User s Operating Instructions. Gas Fired Wall Mounted Combination Boiler

Artisan Thermostatic Bath Shower Mixer

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Getting the best from your urn

Guidance Notes For Provision Of Water Expansion For 10 & 15 Litre Unvented Hot Water Heaters

USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book

Thermostatic bar showers. Troubleshooting and maintenance

Your safety and the safety of others are very important.

STABITHERM INSTALLATION & SERVICE BOOKLET

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION

Almond Kitchen Sink Tap

Liquorice Kitchen Sink Tap

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Almond Kitchen Sink Tap

Cadet Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference

Oil and Coolant Circulating Heating System. Model - OCSM

Colonial Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

Zenith Solar thermal 4.5m pump station Installation manual

INSTALLATION INSTRUCTIONS & OWNERS GUIDE

AIRE Thermostatic bath shower mixer Installation and operating instructions

1. Geo Vertical 2. Geo Horizontal

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

Owner s Guide and Installation Instructions Electric Water Heater

2010 Residential Water Heater Replacement Check List

Maxi Pressurisation Units (Maxi, Maxi Plus & HP)

For installation guide see reverse of book

Installation Instructions S

Apricot Kitchen Sink Tap

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

1. Description. 2. List of Accessories included A B C F G H

Range Tribune HE Solar Unvented Direct and Indirect Cylinders

Owners Guide and Installation Instructions.

Installation and User Instructions Aquaheat Unvented Water Heaters Models: AH7/2.2, AH10/2.2, AH15/2.2

Baxi Combi 130 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Combination Boiler

SELECTION, APPLICATION AND MAINTENANCE

Session 2: Hot Water Supply

ELECTRIC CENTRAL HEATING FLOW BOILER

SERVICE MANUAL Order No.WH0911S001V0

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

WC flushing cistern single or dual flush to fill in 2 minutes WC trough cistern 0.15 per WC Wash basin tap size 1 2

Apricot Kitchen Sink Tap

Unvented water heater

Operating instructions

Water Efficiency Self-Assessment Guide from

Portable Air Conditioner

Owner s Manual. Installation Details Owner s Information. 80L to 400L Electric Storage Water Heaters

IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.

Baxi Platinum Combi HE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler

Builder Specifications for Solar Ready Homes

TRANSMITTER RECEIVER THESE INSTRUCTIONS APPLY IN THE UK ONLY THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE APPLIANCE. Digistat Optimiser

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

Elson 10/15L Unvented Water Heater

Baxi Combi 80e & 105e

Energy Saving Fact Sheet Boilers

REGISTRATION EXAMINATION, NOVEMBER 2013 CERTIFYING PLUMBER ANSWER SCHEDULE

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

OWNER S MANUAL & INSTALLATION GUIDE. Installation Details Owner s Information Warranty. 80L - 400L Electric Storage Water Heaters

Transcription:

MEGAFLO SHRU Installation Instructions Shower Heat Recovery Unit Energy saving performance recognised by SAP Leave these instructions with the user for the homes user pack

Contents Page 2. Introduction 3. Technical Data 6. Installation Preparation 9. Installation 13. Routine Inspection and Maintenance 14. Trouble Shooting 14. User Advice 15. Warranty 1. Introduction The MEGAFLO SHRU (Shower Heat Recovery Unit) is a waste water heat recovery system (WWHRS) that recovers heat from the warm waste water when taking a shower. It relies on the waste water from the shower flowing through a heat exchanger that pre-warms the mains cold water feed to a shower mixing valve and combination boiler or hot water storage cylinder. The MEGAFLO SHRU system consists of a copper heat exchanger, check valve, connection fittings for mains water and 40mm waste water, T-piece with cap insert, and three wall brackets with screws for mounting on a vertical wall. The MEGAFLO SHRU has been developed for dwellings with the bathroom on the second or higher floor, so that when taking a shower the waste water flows under natural conditions through the heat exchanger installed on the floor below the bathroom. Important: The MEGAFLO SHRU has been tested and approved to the UK water regulations and the installation must be carried out in accordance with: UK Water Regulations/Water Byelaws (Scotland)/Water supply regulations (Northern Ireland) All current Building Regulations Health & Safety at Work Act 1974, Approved Code of Practice and Guidance L8 (not applicable to private homes, some landlord owned properties) Energy Saving Performance Recognised by SAP - The successful operation of the MEGAFLO SHRU which is a Waste Water Heat Recovery System (WWHRS) Instantaneous Shower Heat Recovery Device, depends entirely upon the adherence to these instructions. Additionally, for new-build dwellings within the UK, recognition of the system s energy saving performance within the National Calculation Methodology (NCM) for the energy rating of dwellings, known as the Standard Assessment Procedure (SAP) requires that these instructions are complied with in conjunction with a system design checklist and an installation checklist and certificate of installation, supplied with this document and available at: www.ncm-pcdb.org.uk/sap. The system should be installed by a suitably qualified plumber, with system design consideration being equally important to a correct installation. For recognition of the MEGAFLO SHRU within SAP, a system design checklist and an installation checklist and certificate of installation should be completed and signed, with copies kept for the home user pack (home owner), the installer, and sent to Megaflo at the e-mail address shown on the back page (p.16). Building Control Officers may also request a copy. For the purpose of system identification of product data without SAP, the product will have an NCM (SAP) Identifier label permanently fixed to the SHRU 60 unit, whereby the model qualifier states refer to installation certificate, if unknown assume System B. A second NCM (SAP) Identifier label is also supplied and must be affixed to a nearby boiler or service cupboard (the label must be visible for inspection without disassembly of nearby products or systems) and the model qualifier states System A, System B or System C delete as appropriate. Note: 1. The unit must be installed vertically and must self drain to the trap downstream. 2. Failure to install this unit correctly to system A, System B or System C configuration diagrams will invalidate the guarantee and may have an adverse effect on its efficiency. 3. Not sending back the completed and signed system design checklist, the installation checklist and certificate of installation to Megaflo will invalidate the guarantee. 4. Manufacturer s instructions must NOT be taken in anyway as over-riding statutory obligations. 2

2. Technical data 2.1 MEGAFLO SHRU - General Data Description Unit Value Overall length without fittings mm 2060 Overall length including compression fittings and T-piece with cap insert mm 2375 Outside diameter of external tube mm 42 Material internal tube - copper Material external tube - copper Recommended shower flow rate range L/m 5.8 to 12.5 Max. mains water inlet pressure bar 10 Min. mains water pressure bar 0.1 Max. water working temperature 90 Mains water connections mm 15 Waste water connections (compression fitting) mm 43 Weight kg 5 Water content secondary Litres 0.5 2.2 MEGAFLO SHRU Connections Description: 1) 1½" BSP-ISO adaptor 2) 1½" straight connector multifit x BSP coupling 3) Shower waste water "in" 43mm solvent weld connection 4) Shower waste water "out" multifit compression fitting 5) Domestic mains water "out" 15mm comp x ½" BSP fitting (pre-heated) 6) Domestic mains water "in" 15mm comp x ½" BSP fitting 7) Check-valve assembly 15mm compression connections = 3 2 5 1 7 1 6 2 4 Data: Type: MEGAFLO SHRU Article no : 95 060 005 Diagram 1 Connections 3

2.3 MEGAFLO SHRU - Performance Shower flow rate: 5,5 l/m T1; cold domestic water in 2.4 MEGAFLO SHRU Efficiency 10 T2; pre-heated domestic water out 29 28,2 27,4 25,2 T3; shower water 40 40 40 40 C T4; shower water entry on SHRU 1 40 40 40 40 T5; shower waste water to waste 21 * 22 * 23 * 24 water line Shower energy consumption 2 kw 11,5 15,7 21,9 31,6 Recovered energy 3 kw 7,3 9,45 12,7 16,9 Pressure drop domestic water kpa 9,6 21 35,1 79 Efficiency of recovery unit % 63 62,4 60 59,3 58 55,2 53 * KIWA-Gastec declaration according to NEN 5128 A1:2009, published 1 May 2009 5,8 l/m 7,5 l/m 10 9,2 l/m 10,5 l/m 10 12,5 l/m 15,1 l/m 10 efficiency % flow 1. Standard test conditions 2. Energy consumption in kw = kg/s * 4,2 * (T3 T1) 3. Energy recovered kw = shower flow rate kg/s * 4,2 * (T2 T1) 4

2.5 MEGAFLO SHRU Pressure drop Mains Water Circuit Note: 100 kpa = 1 bar 5

3 Installation preparation 3.1 System principle The Megaflo Shower Heat Recovery Unit (SHRU) is a waste water heat recovery system (WWHRS) that recovers heat from the warm waste water when taking a shower. It relies on the waste water from the shower flowing through a heat exchanger that pre-warms the mains cold water feed to a shower mixing valve and instantaneous boiler or hot water storage cylinder. It is recommended that the pre-heated mains water from the unit is connected to both the cold water supply of the shower mixing valve and the combination boiler or hot water cylinder, as shown below (recommended System A configuration). System A configuration will provide a balanced water flow and is the most efficient way to recover the maximum amount of energy. In case of an unbalanced water flow if, for example, only the cold water supply to the shower mixer valve is pre-heated (System B configuration) or the pre-heated mains water from the unit is only connected to the combination boiler or hot water cylinder (System C configuration), the efficiency of the SHRU will decrease by at least 15%. Installation Configurations System A System B - WWHRS outlet connects to water heater inlet AND shower cold inlet - WWHRS outlet connects to shower cold inlet ONLY System C - WWHRS oulet connects to water heater ONLY Note: It is essential that a trap is installed downstream of the SHRU and that NO trap is installed directly underneath the shower tray 6

3.2 Location and clearances The MEGAFLO SHRU has been developed for dwellings with the bathroom on the second or higher floor, so that when taking a shower the wastewater flows under natural conditions through the heat exchanger installed on the floor below the bathroom. Therefore, the unit must be mounted vertically securely onto a flat wall with the brackets supplied. It is recommended that the SHRU is installed in a location where all parts of the unit are accessible and routine maintenance such as cleaning can be carried out with reasonable ease. Prevent the MEGAFLO SHRU from being heated above 25 C by an external source. Also, the MEGAFLO SHRU must not be located where ambient temperatures may be above 25 C. The preheated water supply inline of the MEGAFLO SHRU must be insulated in accordance with the requirements of the Building Services Compliance Guide. Note: Do not insulate the MEGAFLO SHRU itself. It is required that the distance from the shower tray to the MEGAFLO SHRU is kept to within 3 meters to reduce any heat losses and ensure good efficiency is maintained. Minimum clearances of 80mm around the main body should be maintained and adequate clearances must be maintained at the top and bottom to ensure all components are accessible and can be cleaned or replaced, if necessary. Note: It is recommended the SHRU is fitted with a cleaning tee and blanking cap at the top of the unit to enable the waste water section of the unit to be cleaned. 3.3 Design Flow Chart - Checklist With reference to the information written above in this chapter, take into account the items in the checklist underneath are required before the MEGAFLO SHRU is installed to ensure it is suitable for installation in the dwelling. Item Description Decision (tick as appropriate) 1 Has consideration been given to DHW delivery performance (water pressure and flow rate)? 2 Is the dwelling hot water system (DHW) a mains pressure system? 3 Does the water heater accept a preheated water inlet (Max 30 C) (N/A if installed in System B configuration)? 4 The length of drain pipe between shower and MEGAFLO SHRU is less than 3 meter? 5 Is a trap / s-bend installed? 6 Is sufficient space for service and cleaning available? 7 Has a System A, B or C configuration been selected? 8 Is the plumbing design configured in order to prevent connection of hot water takeoff points, such as taps, from the MEGAFLO SHRU preheated water outlet? 9 Is an installation location specified for the MEGAFLO SHRU that does not normally exceed 25 C? 10 Can the MEGAFLO SHRU be installed within a tolerance of ±20mm of vertical? 11 If shut-off valves are specified for MEGAFLO SHRU inlet and/or outlet, are they full flow (non-restricting) shut-off valves? (Tick if N/A) 7

3.4 Installation Recommendations a) When showering with the SHRU installed, the cold water inlet temperature will increase slowly because it will be warmed from the heat transferred from the waste water, via the SHRU heat exchanger. If a non-thermostatically controlled showerhead is fitted, continued adjustment of the valve will be required to avoid hotter water temperatures from the shower. Therefore, it is required that a thermostatically controlled showerhead is always fitted. b) Ensure full flow shut off valves are fitted at both connections of the unit to allow for any replacement of parts (refer to diagram 3) c) The cold / preheated feed pipe work to the shower from the SHRU must be installed as shown in Diagram 2 ie. the pipe must be plumbed up to the T connection at the thermostatic mixing valve of the shower, and then from this T connection to the cold inlet of the combination boiler or hot water store. This will ensure static water is not held in the line for long periods without being flushed, providing other hot water taps are being used. d) After installation all domestic water pipe work should be flushed and cleaned. This also applies if a system has been substantially altered. However, this would be required even if a shower heat recovery unit had not been fitted. (Refer Approved COP L8 for guidance) e) Pipework between the WWHRS preheated water outlet and the water heater and /or shower cold water inlet(s) (depending on installation configuration) must be labelled to indicate that no other services can be interconnected. f) The hot water store or combination boiler must be set to provide and distribute hot water at a temperature of at least 60 C. 8

4. Installation 4.1 Packing The MEGAFLO SHRU is supplied in one box and the contents is as follows: Pos. Qty Description Drawing 1 1 MEGAFLO SHRU body 2 2 ½ BSP x 15 mm compression fitting & washer 3 2 1½ BSP ISO Adaptor and washer 4 2 1½ Straight Connector Multifit x BSP Coupling 5 1 T- fitting Ø 43 mm solvent weld (for 43 mm waste pipe) + 43mm Cap and connection tube 6 3 Wall mounting brackets, screws and 10mm wall plugs 7 1 15mm Check valve assembly (cold domestic mains water inlet) + 50mm length Ø15mm copper tube 8 1 Installation Instructions 9

Pos. Qty Description Drawing 9 1 NCM (SAP) Identifier label (to be affixed to a nearby boiler or service cupboard) 10 1 Design checklist 11 1 Installation checklist In addition to the above it is recommended two full flow 15mm shut off valves are obtained for the installation to enable isolation of the mains water circuit if any replacement is required. 4.2 Location and clearance required Refer to section 3.2 p.7 before locating the MEGAFLO SHRU. 4.3 Installation of the MEGAFLO SHRU The unit must be installed vertically (tolerance of +/-20mm) on a flat wall that is capable of supporting its weight (refer to section 3.2 p.7). If the unit is not mounted absolutely vertical it could reduce the efficiency performance. Mount the unit on the wall as follows: a) Mark and drill in a straight vertical line the three holes, equally divided over a length of 160 cm, for the 10mm wall plugs supplied with the wall brackets (refer Diagram 3) b) Fit the wall plugs into the holes and install the three mounting brackets (pos 6, 4.1) supplied by screwing into the plugs. c) Remove one half of the bracket and mount the unit (pos. 1, 4.1) into the brackets securing it with the half bracket removed. Note: Check that the unit is vertical and the bottom end of the unit is at the lowest position d) Connect the 1 ½ BSP-ISO adaptors (pos 3, 4.1), using the washers supplied, to both ends of the unit. (Refer 1, diagram 1) 10

e) Connect the 1 ½ multifit-bsp couplings (pos 4, 4.1) to the adaptors (pos 3, 4.1) at both ends of the unit. (Refer 2, diagram 1) f) Connect the T-fitting and cap (pos. 5, 4.1) to the 1 ½ multifit connector (pos 4, 4.1) at the top end of the unit, using the 43 mm connection tube supplied. Connect the T-piece, connection tube and cap using suitable solvent cement. (Refer 8, diagram 1 & picture below). Shower waste water "in" from shower tray to T-piece side inlet Connection Tube Solvent weld connections = g) Connect the waste water pipe from the shower to the inlet of the T-piece at the top of the SHRU (Refer picture above) using a 43mm solvent weld pipe connection. h) Connect the SHRU shower wastewater outlet to the sewer via an s-bend/trap (Refer 4, Diagram 1 & Diagram 2). It is recommended to use compression fittings to establish the connection between the SHRU wastewater out 1 ½ multifit connector and the s-bend/trap. i) Connect the ½ to 15mm fittings (pos 2, 4.1) to the domestic mains water in and out of the SHRU connections using the washers supplied (Refer 5 & 6, diagram 1). j) Connect the 50mm long Ø15mm pipe (pos 7, 4.1) to the domestic mains water in 15mm compression fitting at the lower end of the unit. Then, connect the check valve assembly (pos 7, 4.1) to the 15mm pipe as in Diagram 1, no 7. Note: Ensure the check valve assembly is fitted with the arrow pointing in the direction of flow. k) Connect 15mm pipe between the top of the SHRU unit out connection (Diagram 1, no 5) and shower unit/ water heater as detailed in Diagram 2 and section 3.4.C. Then, complete the installation by connecting the mains water supply to the domestic mains water in connection at the lower end of the unit (Refer Diagram 1, no7). Note: Ensure full flow shut off valves are fitted before both domestic mains water connections of the unit to allow for any replacement of parts or removal of the complete unit (Refer Diagram 3). 11

Position wall brackets 800 mm apart and in line vertically as shown 800 mm T- connection and cap. It is recommended full flow shut off valves are fitted at both domestic mains water connections of the unit, as shown below (Not supplied) Note: If the MEGAFLO SHRU has not been installed 100% vertically, it could reduce the efficiency = performance. Maximum offset A = +/-20 mm Diagram 3 Recommended position of wall brackets and mains water shut off valves. ±^ = 12

5. Routine inspection and maintenance To avoid a lower efficiency in the longer term, it is recommended to clean the MEGAFLO SHRU. Over a period of time it is likely that the MEGAFLO SHRU will start to gather residue, to avoid this it is advised that it is flushed with a household drain cleaner. Periodically, it is recommended to check the installation for leaks etc. 13

6. Trouble shooting The efficiency seems to be lower than before: The inner surface of the SHRU wastewater surface might be dirty/contaminated. Therefore, clean the device as described in section 5. 7. User Advice a) If the hot water system is left to stand for 7 days or more without being used then the system should be flushed to drain for some 3 minutes by turning on a hot water tap slowly so as not to create splashing. This would be advised even if a shower heat recovery unit had not been fitted. b) Any non-domestic users are advised that any showerheads and hoses should be cleaned on a quarterly basis. 14

Warranty The MEGAFLO SHRU warranty is valid for 2 years after installation date. The production date is indicated on the type plate. The warranty does not apply to: Disassembly and assembly costs. Faults which are, in our opinion, caused by incorrect treatment, negligence or an accident. Faults that have been caused by repairs or intended repairs by third parties without our authorisation. Faults caused by irregular and / or incompetent maintenance. Modification to the appliance. Incorrect installation of the appliance. Should the unit become damaged or malfunction, switch it off, isolating it from the mains supply, and contact Megaflo immediately. 15

Customer service Telephone: 01603 420100 E-mail: itho@heatraesadia.com 2013 16 36006178_issue_04