HEALTH LEVEL SEVEN SAMPLE CERTIFICATION TEST HL7 2.6 STANDARD CHAPTER 2, 2A, 2B CONTROL

Similar documents
ImagePilot. HL7 Conformance Statement. Manufacturer: 1 Sakura-machi, Hino-shi Tokyo , Japan

How To Get A Medical Record On A Medical Device

ELR Clarification Document for EHR Technology Certification V1.1

9. Medical Records/Information Management

HL7 Interface Specification. HL7 Interface 1.2

UHIN STANDARDS COMMITTEE Version 2.0 Radiology Report Standard

ELR Clarification Document for EHR Technology Certification

HL7 Customization Guide

Additional Information Message Implementation Guide

HL7 Interface Specifications

JiveX Enterprise PACS Solutions. JiveX HL7 Gateway Conformance Statement - HL7. Version: As of

HL7 Conformance Statement

HL7 EHR to PowerSoftMD Visit Import Specifications

IHE Radiology Technical Framework Volume 3 (IHE RAD TF-3)

EHR-Laboratory Interoperability and Connectivity Specification (ELINCS) Version 0.2 DRAFT

HL7 Conformance Statement RadCentre. Release

HL7 Fundamentals. Presented by: Dana McDonough, Carolina Velasquez, & Bing Chen. August 2014

IHE Radiology (RAD) Technical Framework. Volume 2 IHE RAD TF-2 Transactions

HL7 Interface Specification Merge LabAccess v. 3.6

Quickly and easily connect your Imaging System with Practice Fusion s Electronic Health Record (EHR) System. HL7 Results Specification

Welch Allyn Connectivity Server

HL7 Conformance Statement

Notes Interface Specification HL7 format

HL7 Interface Specification Merge Eye Station v. 11.3

Connecticut Department of Public Health Electronic Laboratory Reporting HL7 v2.5.1 Message Validation Tool User Guide

PARCA Certified PACS Interface Analyst (CPIA) Requirements

Eligible Hospital (EH) Onboarding Approach for the Meaningful Use (MU) Incentive Program

GE PACS Conformance Statement for DICOM v3.0

How To Write A Health Care Exchange Transaction

Message Specifications Guide

A Development of HL7 Middleware for Medical Device Communication

DIAGNOSTIC TEXT AND OTHER TRANSCRIBED REPORTS MESSAGE SPECIFICATION

Philips Innovation Campus Bangalore India. Issued by:

Copyright Swearingen Software, Inc. All rights reserved.

IHE IT Infrastructure Technical Framework. Volume 2b (ITI TF-2b) Transactions Part B Sections

7. Observation Reporting

Patient Demographics Query (PDQ)

Generic EHR HL7 Interface Specification Abraxas v. 4

NEW SOUTH WALES DEPARTMENT OF TRANSPORT. Transport Services Division. Driver Authority Information Service Format Specification

USING MYWEBSQL FIGURE 1: FIRST AUTHENTICATION LAYER (ENTER YOUR REGULAR SIMMONS USERNAME AND PASSWORD)

Syndromic Surveillance Event Detection of Nebraska (SSEDON) HL7 Implementation Guide Inpatient Syndromic Surveillance

Implementation Guide for Transmission of. Microbiology Result Messages. as Public Health Information using. Version of the

Arkansas Blue Cross Blue Shield EDI Report User Guide. May 15, 2013

AIDA compact NEO HL7 Interface Description

EDIFACT Standards Overview Tutorial Learn About Key E-commerce Trends and Technologies at Your Own Pace

ANSI X12 version Advance Ship Notice

Technical Publication. DICOM Conformance Statement. DICOM Proxy 2.0. Document Revision 3. October 20, Copyright Brainlab AG

Generic Interface System

D* SEE SAP DIR DIGITAL SIGNATURE LOG FOR APPROVER NAME AND DATE OF APPROVAL

Smart Card Authentication. Administrator's Guide

S.2.2 CHARACTER SETS AND SERVICE STRING ADVICE: THE UNA SEGMENT

The information in this document will be common for all X12N implementation guides.

R.2 STRUCTURE OF AN EDIFACT TRANSMISSION

DICOM Conformance Statement

DICOM Conformance Statement FORUM

Interfacing Boot Camp

Cognos Event Studio. Deliver By : Amit Sharma Presented By : Amit Sharma

KANSAS CITY SOUTHERN EDI On-Boarding Guide

20/20 Integration Guide

Kiwi SyslogGen. A Freeware Syslog message generator for Windows. by SolarWinds, Inc.

997 Functional Acknowledgment

E-payment. Service description

Merchant Interface Online Help Files

Qlik REST Connector Installation and User Guide

Electronic Mail

837 I Health Care Claim HIPAA 5010A2 Institutional

Receiving Advice/Acceptance Certificate - SERVICE PARTS ONLY

1 DNS Packet Structure

Overview. LATITUDE Patient Management. EMR Integration Testing Scenarios

ODBC Client Driver Help Kepware, Inc.

LabVIEW Internet Toolkit User Guide

StreamServe Persuasion SP4 StreamServe Connect for SAP - Business Processes

Informatics for Integrating Biology and the Bedside. i2b2 User Guide. Import Data View. Document Version: I2b2 Software Release: 1.

HEALTH INFORMATION STANDARDS COMMITTEE FOR ALBERTA

User s Guide. Security Operations Ver. 1.02

Electronic Data Interchange (EDI) Standards 810 Invoice Version 4010

Oracle SOA Suite 11g Oracle SOA Suite 11g HL7 Inbound Example Functional ACK Addendum

Florida Blue Health Plan

Core Components Data Type Catalogue Version October 2011

Protocol Data Units and Encapsulation

HL7 & KMEHR. A comparison. Medical informatics AJ 2013/2014. Authors: Tessa Borloo Nele Pien

Basic processes in IEEE networks

How To Write A File System On A Microsoft Office (Windows) (Windows 2.3) (For Windows 2) (Minorode) (Orchestra) (Powerpoint) (Xls) (

Portal Connector Fields and Widgets Technical Documentation

DoD Transportation Electronic Data Interchange (EDI) Convention

EDI Guide - Appendix T 861 Receiving Advice/Acceptance Certificate (From Navy ERP/ILSMIS to irapt)

837 I Health Care Claim Institutional

Database Programming with PL/SQL: Learning Objectives

X12 Implementation Guidelines For Outbound Receiving Advice v (861O)

PART-A Questions. 2. How does an enumerated statement differ from a typedef statement?

837P Health Care Claim Professional

Design of Internet Protocols:

How To Use Optimum Control EDI Import. EDI Invoice Import. EDI Supplier Setup General Set up

DIGICLIENT 8.0 Remote Agent Software

RamSoft PACS 3.0 HL7 Conformance Statement

Now, suppliers can also select EDI as a method for receiving Change and Cancel Orders.

PayPal Integration Guide

837 Professional Health Care Claim

ANSI X12 version Planning Schedule with Release Capability

Documentation to use the Elia Infeed web services

Transcription:

HEALTH LEVEL SEVEN SAMPLE CERTIFICATION TEST HL7 2.6 STANDARD CHAPTER 2, 2A, 2B CONTROL

HL7 2.6 Chapter 2: Control Date: Sample Test Name: ID: Instructions Put the following version number on your answer sheet: Sample Test. 1. The original mode acknowledgment protocol is equivalent to the enhanced acknowledgment protocol with which of the following field values? A. Just the MSH-15-accept acknowledgment type equal to "AL", the MSH-16-application acknowledgment type doesn't matter. B. Just the MSH-16-application acknowledgment type equal to "AL", the MSH-15-accept acknowledgment type doesn't matter. C. The MSH-15-accept acknowledgment type equal to "NE" and the MSH-16-application acknowledgment type equal to "AL". D. The MSH-15-accept acknowledgment type equal to "AL" and the MSH-16-application a acknowledgment type equal to "NE". E. The MSH-15-accept acknowledgment type equal to "NE", the MSH-16-application acknowledgment type doesn't matter. 2. If the component definition calls for a component to be broken into subcomponents, which of the following rules are used? I. If more than one subcomponent is included, they are separated by the subcomponent separator. II. Subcomponents that are not present are represented by the characters "". III. A subcomponent that is present but null is represented by including no characters in the subcomponent. IV. Subcomponents that are present but null at the end of a component need not be represented by subcomponent separators. A. I., II., III., and IV. B. I., II., and III. only C. I. and IV. only D. I. only E. II., III., and IV. only 3. Which of the following is NOT a possible designation of optionality for a field within a segment in the segment attribute tables of the HL7 2.6 standard? A. R - Required B. O - Optional C. C - Conditional on the trigger event or on some other field(s) D. Z - User defined E. B - Left in for Backward compatibility with previous versions of HL7 4. If the field definition calls for a field to be broken into components, which of the following rules are used: I. If more than one component is included, they are separated by the component separator. II. Components that are present but null are represented by the characters "". Page 2

III. IV. A component that is not present is indicated by including no characters in the component. Components that are not present at the end of a field must be represented by component separators. A. I., II., III., and IV B. I., II., and III. only C. I., II., and IV. only D. I., III., and IV. only E. II., III., and IV. Only 5. Given the following abstract message definition: MSH Message Header MSA Message Acknowledgment [ { WDN Widget Description { WPN Widget Portion } [ WPD Widget Portion Detail ] } ] Which of the following ordered segments in a message would be ILLEGAL? A. MSH MSA B. MSH MSA WDN WPN WPN WPD WDN C. MSH MSA WDN WPN WPN D. MSH MSA WDN WPN WDN WPN WDN WPN E. MSH MSA WDN WPN WPN WPD WDN WPN WPN WPD 6. The segment FHS contains which of the following fields? A. Batch Creation Date/Time B. Batch Control ID C. File Batch Count D. File Encoding Characters E. File Trailer Comment 7. A DSC continuation pointer segment could be used to continue which of the following messages? I. QRY/DSR - original mode display query - immediate response (event Q01) II. QRY/QCK - deferred query (event Q02) III. DSR/ACK - deferred response to a query (event Q03) IV. ADT/ACK - register a patient (event A04) V. UDM/ACK - unsolicited display update message (event Q05) A. I., II., III., IV., and V. B. I. II., III., and V. only C. I., II., and III., only D. I. and II. only E. V. only 8. Which of the following characters is the suggested HL7 2.x Field Separator? A. B. ^ Page 3

C. & D. ~ E. \ 9. What data type is the following field? \.in+4\\.ti-4\ 1. The cardiomediastinal silhouette is now within normal limits.^\.sp\\.ti-4\ 2. Lung fields show minimal ground glass appearance.^\.sp\\.ti-4\ 3. A loop of colon visible in the left upper quadrant is distinctly abnormal with the appearance of mucosal effacement suggesting colitis.\.in-4\ A. HT - Hypertext Markup Language B. FT - Formatted text C. RT - Rich Text D. TX - Text Data E. XM - Extended Markup Language 10. Which of the following are allowed in future 2.x versions of HL7: I. New messages. II. New segments. III. New fields. IV. New components. A. I., II., III., and IV. B. I., II. and III. only C. I., II., and IV. only D. I., III., and IV. only E. II., III., and IV. only 11. Which of the following is NOT an example of an HL7 2.6 trigger event? A. Delete Person Information. B. Application Acknowledgment. C. Query sent for deferred response. D. Swap Patients. E. Unsolicited transmission of an observation message. 12. Given the following abstract message definition: MSH Message Header MSA Message Acknowledgment [ { PID Patient Identification [ { WDN Widget Description { WPN Widget Portion } [ WPD Widget Portion Detail ] } ] } ] Which of the following ordered segments in a message would be ILLEGAL? A. MSH MSA PID B. MSH MSA PID WDN WPN WPD PID PID PID C. MSH MSA PID WDN WPN WDN WPN WPN WPD Page 4

D. MSH MSA PID WDN WPN WDN WPN WPD E. MSH MSA PID WDN WPN WPD WPD WDN WPN 13. If the default encoding characters are being used, and a text field is being encoded whose content is the string "John & Mary", which of the following statements are true? I. The "&" must be encoded with an escape sequence.!i. The "&" must be stripped from the string before encoding. III. The "&" must be encoded with Base64 encoding. IV. The "&" must be encoded with "\T\" if the suggested encoding characters are being used. V. The "&" must be encoded with "\A\" if the suggested encoding characters are being used. A. I. and III. only B. I. and IV. only C. I. and V. only D. II. only E. III. only 14. Which of the following statements about message construction using standard HL7 encoding rules are true? I. Segments must be constructed in the order defined for the message. II. The first three characters of each Segment must be the segment ID code. III. The final segment does not need to end with the Segment Terminator. IV. The MSH can redefine the Segment Terminator. A. I., II., and III. only B. I., II., and IV. only C. I. and II. only D. I. and IV. only E. II., III., and IV. only 15. Which of the following statements is NOT true regarding the HL7 ID number in segment attribute tables? A. It is a user defined field. B. It uniquely identifies the data field within the segment. C. It is also known as Item #. D. It can be used in the RCD (Row Column Definition) Segment of HL7 queries to identify the data element. E. It is a small integer (nnnnn). Page 5

16. Which of the following statements are true regarding the HL7 2.x data type Hierarchic Designator (HD)? I. The HD enables the transmission of information for any site to act as an assigning authority (on a local or user-defined basis), even if it technically does not have the right to issue new IDs within an identification scheme. II. HDs which have defined third components (defined UID types) must contain a value in the second component that is unique within the series of ID s defined by the third component. III. Data type HD is interchangeable with data type CWE (Coded With Exceptions). A. I., II., and III. B. I. and II. only C. I. and III. only D. II. and III. only E. I. only 17. Which of the following statements are true? I. The suggested HL7 2.x Repetition Separator character is "~" II. The suggested HL7 2.x Component Separator character is " " III. The Escape Character cannot be redefined by the Message Header Segment. A. I., II., and III. B. I. and II. only C. I. and III. only D. II. and III. only E. I. only 18. What is the specified maximum field length for a field of data type IS? A. 20 B. 64 C. 199 D. 65536 (64K) E. The maximum length may vary depending on the longest code in the code set. 19. Which of the following rules apply to receiving HL7 messages and converting their contents to data values? I. Ignore segments, fields, components, subcomponents, and extra repetitions of a field that are present but were not expected. II. Treat segments that were expected but are not present as consisting entirely of fields that are present but null. III. Treat fields and components that are expected but were not included in a segment as not present. A. I., II., and III. B. I. and II. Only C. I. and III. only D. II. and III. only E. I. only Page 6

20. Which of the following rules apply to receiving HL7 messages and converting their contents to data values: I. The receiving system must return an error acknowledgment for segments, fields, components, subcomponents, and extra repetitions of a field that are present but were not expected. II. The receiving system must treat segments that were expected but are not present as consisting entirely of fields that are not present. III. IV. The receiving system must treat fields valued with two double quotes "" as not present. The receiving system must treat fields and components that are expected but were not included in a segment as present but null. A. I., II., and III. only B. I., II., and IV. only C. I. and II. only D. I. only E. II. only 21. Which of the following is not a component of the HD data type? A. Name of Coding System. B. Namespace ID. C. Universal ID. D. Universal ID type. E. None of the above. All of the above are components of the HD data type. 22. An EKG waveform image could be encoded in which of the following HL7 2.6 data types? A. CD - Channel definition B. CM - Composite C. ED - Encapsulated data D. EK - Electrocardiogram E. MA - Multiplexed array 23. Which of the following capabilities does the HL7 2.6 standard assume that the communications environment will provide? I. Ethernet network. II. III. IP addressing of the sending and receiving sites. Character conversion if the two machines exchanging data use different character sets. A. I., II., and III. B. I. and II. only C. II. and III. only D. III. only E. None. HL7 2.6 does not assume that the communications environment will provide any of these capabilities. 24. What acknowledgment code should a system return as an accept acknowledgment if the message cannot be accepted because of a sequence number error? Page 7

A. CA B. CR C. CE D. CX E. None of the above. 25. Which of the following statements are true? I. A DICOM image could be transmitted in an element of the ED (Encapsulated Data) data type. II. A value of type HD (Hierarchic Designator) could contain, as one of its components, a DICOM image. III. A DICOM image could be transmitted in an element of the CD (Channel Definition) data type. A. I., II., and III. B. I. and II. only C. I. and III. only D. II. and III. only E. I. only 26. What data type is the following field? ^100^-^200 A. CQ - Composite quantity with units B. NM - Numeric C. SI - Sequence ID D. SN - Structured numeric E. None of the above. 27. Which of the following statements about HL7 2.x message construction are true? A. Segments may repeat within a message. B. Fields may repeat within a segment. C. Components may repeat within a field. D. Both A and B are true. E. A, B, and C are all true. 28. How does HL7 provide for the transmission of user authentication credentials, such as a Kerberos service ticket or a SAML assertion? A. The information should be sent in the UAC segment. B. The information should be sent in the EVN segment. C. The information should be sent in the ORC segment. D. The information should be sent in field MSH-8-Security. E. HL7 does not specify any mechanism for transmitting user authentication credentials. Page 8

29. Which of the following values for Identifier type code (the fifth component of data type CX - Extended composite ID with check digit) is part of the HL7-defined table published in the standard? A. Base64 - Base64 encoding as defined by MIME (Multipurpose Internet Mail Extensions) standard RFC 1521 B. BID - twice a day at institution-specified times (e.g., 9AM-4PM) C. PI - Patient Identifier D. XML - extended Markup Language E. Z - Z Segment 30. Which of the following segments contains the field Encoding Characters? A. DSC B. ERR C. MSA D. MSH E. NTE 31. Which of the following escape sequences represents start highlighting? A. \E\ B. \F\ C. \H\ D. \S\ E. \B\ For Questions 32-35, please refer to the OBX Segment definition in Figure I below when deciding your answer. Figure I: OBX Segment Fields Seq Len DT Usage Cardinality TBL# Item # Element Name 1 4 SI R [1..1] 00569 Set ID OBX 2 2 ID R [1..1] 0125 00570 Value Type 3 250 CE R [1..1] 00571 Observation Identifier 5 65536 R [1..1] 00573 Observation Value 6 250 CE C [1..1] 00574 Units 11 1 ID R [1..1] 0085 00579 Observation Result Status Note: For any field not shown, assume that the Usage value is X and the Cardinality value is [0..0]. 32. If Field 4, Observation Sub-ID, is transmitted in a segment formatted according to the OBX segment definition in Figure I above, the receiver: A. May accept the field but is allowed to reject it B. Must accept the field (pending further processing of the field contents) C. Must reject the field D. Should truncate the field to a length of 250 characters E. May accept the field if and only if it is accompanied by at least one occurrence of Field 3, Observation Identifier Page 9

33. Which of the following fields may be omitted from a segment formatted according to the OBX segment definition in Figure I above? A. Field 1, Set ID - OBX B. Field 2, Value Type C. Field 3, Observation Identifier D. Field 5, Observation Value E. Field 6, Units 34. The OBX segment definition in Figure I above is referred to in HL7 as a: A. Vocabulary table B. Static definition field level C. Static definition message level D. Static definition segment level E. Segment attribute table 35. Assume that the HL7 default encoding and suggested delimiters are in use. Which of the following could never be a valid instance of an OBX segment formatted according to the OBX segment definition in Figure I above? A. OBX 1 ST 8601-7^ECG Impression^LN Sinus rhythm, rate 60 F B. OBX 2 NM 8625-6^PR INTERVAL^LN 109 F C. OBX 3 NM 8633-0^QRS DURATION^LN 90 F D. OBX 4 NM 8634-8^QT INTERVAL^LN 365 F E. OBX 5 NM 8636-3^QT INTERVAL CORRECTED^LN 365 *** END OF TEST *** Please check over your answers before turning in your test. Make sure that all your answers are accurately reflected on your answer sheet. A passing score is 70% or more correct. For this sample exam, a score of 25 or more correct is passing. There is no penalty for guessing and no penalty for wrong answers. Answer Key: 1. (C) The MSH-15-accept acknowledgment type equal to "NE" and the MSH-16-application acknowledgment type equal to "AL". 2. (D) I. only 3. (D) Z - User defined 4. (B) I., II., and III. only Page 10

5. (B) MSH MSA WDN WPN WPN WPD WDN 6. (D) File Encoding Characters 7. (A) I. II., III., IV., and V. 8. (A) 9. (B) FT - Formatted text 10. (A) I., II., III., and IV. 11. (B) Application Acknowledgment. 12. (E) MSH MSA PID WDN WPN WPD WPD WDN WPN 13. (B) I. and IV. only 14. (C) I. and II. only 15. (A) It is a user defined field. 16. (B) I. and II. only. 17. (E) I. only 18. (A) 20 19. (C) I. and III. only 20. (E) II. only 21. (A) Name of Coding System. 22. (C) ED Encapsulated data 23. (D) III. 24. (C) CE 25. (E) I. only 26. (D) SN - Structured numeric 27. (D) Both A and B are true. 28. (A) The information should be sent in the UAC segment. 29. (C) PI Patient Identifier. 30. (D) MSH 31. (C) \H\ 32. (A) May accept the field but is allowed to reject it. Page 11

33. (E) Field 6, Units 34. (D) Static definition segment level 35, (E) OBX 5 NM 8636-3^QT INTERVAL CORRECTED^LN 365 Page 12