Single Phase Inverter with Selective Harmonics Elimination PWM Based on Secant Method

Similar documents
Modified Cascaded Five Level Multilevel Inverter Using Hybrid Pulse Width Modulation

SPEED CONTROL OF INDUCTION MACHINE WITH REDUCTION IN TORQUE RIPPLE USING ROBUST SPACE-VECTOR MODULATION DTC SCHEME

Simulation and Analysis of Parameter Identification Techniques for Induction Motor Drive

Control of a Three Phase Induction Motor using Single Phase Supply

Design and Simulation of Soft Switched Converter Fed DC Servo Drive

Design of Four Input Buck-Boost DC-DC Converter for Renewable Energy Application

Simulation and Analysis of PWM Inverter Fed Induction Motor Drive

Simulation of VSI-Fed Variable Speed Drive Using PI-Fuzzy based SVM-DTC Technique

MODELING AND SIMULATION OF A THREE-PHASE INVERTER WITH RECTIFIER-TYPE NONLINEAR LOADS

New Pulse Width Modulation Technique for Three Phase Induction Motor Drive Umesha K L, Sri Harsha J, Capt. L. Sanjeev Kumar

Design a Phase Interleaving PFC Buck Boost Converter to Improve the Power Factor

MODELLING AND SIMULATION OF SVPWM INVERTER FED PERMANENT MAGNET BRUSHLESS DC MOTOR DRIVE

Survey of Harmonics Measurements in Electrical Distribution Systems

Analysis of AC-DC Converter Based on Power Factor and THD

Modelling, Simulation and Performance Analysis of A Variable Frequency Drive in Speed Control Of Induction Motor

Real Time Selective Harmonic Minimization for Multilevel Inverters Connected to Solar Panels Using Artificial Neural Network Angle Generation

POWER SYSTEM HARMONICS. A Reference Guide to Causes, Effects and Corrective Measures AN ALLEN-BRADLEY SERIES OF ISSUES AND ANSWERS

Interfacing Renewable Energy Sources to the AC Grid by a CMLI with Voltage Regulation under Low THD

THE development of new methods and circuits for electrical energy conversion

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

Analysis and Control of Three Phase Multi level Inverters with Sinusoidal PWM Feeding Balanced Loads Using MATLAB

Chapter 4 AC to AC Converters ( AC Controllers and Frequency Converters )

THIS paper reports some results of a research, which aims to investigate the

Iowa State University Electrical and Computer Engineering. E E 452. Electric Machines and Power Electronic Drives. Laboratory #3 Figures of Merit

Parametric variation analysis of CUK converter for constant voltage applications

Analysis of Space Vector Pulse Width Modulation VSI Induction Motor on various conditions

AN ULTRA-CHEAP GRID CONNECTED INVERTER FOR SMALL SCALE GRID CONNECTION

Module Voltage Balancing Algorithm for Phase Shifted SPWM Controlled Cascaded Multilevel Inverter

Design and Development of Speed Control of Induction motor drive using Pulse-Width Modulation

How To Simulate A Multilevel Inverter

An Efficient AC/DC Converter with Power Factor Correction

Power Flow Control Using Bidirectional Dc/Dc Converter for Grid Connected Photovoltaic Power System

Modeling and Simulation of a Novel Switched Reluctance Motor Drive System with Power Factor Improvement

Pulse Width Modulated (PWM)

Modeling and Analysis of DC Link Bus Capacitor and Inductor Heating Effect on AC Drives (Part I)

A MULTILEVEL INVERTER FOR SYNCHRONIZING THE GRID WITH RENEWABLE ENERGY SOURCES BY IMPLEMENTING BATTERY CUM DC-DC CONERTER

Pulse Width Modulated (PWM) Drives. AC Drives Using PWM Techniques

Performance Enhancement of Wound Rotor Induction Motor by VSI with Dynamic Capacitor Controlled Rotor Circuit

Novel Loaded-Resonant Converter & Application of DC-to-DC Energy Conversions systems

MATRIX TECHNICAL NOTES

Power System review W I L L I A M V. T O R R E A P R I L 1 0,

SIMULATION OF CLOSED LOOP CONTROLLED BRIDGELESS PFC BOOST CONVERTER

Hybrid Power System with A Two-Input Power Converter

Bridgeless PFC Implementation Using One Cycle Control Technique

UNDERSTANDING POWER FACTOR AND INPUT CURRENT HARMONICS IN SWITCHED MODE POWER SUPPLIES

Variable Voltage Variable Frequency Speed Control of Induction Motor Using FPGA-Xilinx

DESIGN AND DEVELOPMENT OF UTILITY INTERFACE ADAPTIVE SOLAR POWER CONVERTER FOR WATER PUMPING SYSTEM IN INDIAN VILLAGES

Mathematical Modelling of PMSM Vector Control System Based on SVPWM with PI Controller Using MATLAB

NEURO-FUZZY BASED POWER QUALITY IMPROVEMENTS IN A THREE PHASE FOUR WIRE DISTRIBUTION SYSTEM USING DSTATCOM

High Intensify Interleaved Converter for Renewable Energy Resources

7-41 POWER FACTOR CORRECTION

Grid Interconnection of Renewable Energy Sources Using Modified One-Cycle Control Technique

Closed Loop PWM Control for Induction Motor Drive Using Dual Output Three Phase Inverter

2 Topology and Control Schemes

Multilevel DC-AC Converter Interface with Solar Panels

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

Student Pulse Academic Journal

APPLICATION NOTES: Dimming InGaN LED

Transient analysis of integrated solar/diesel hybrid power system using MATLAB Simulink

INDUCTION MOTOR PERFORMANCE TESTING WITH AN INVERTER POWER SUPPLY, PART 2

The D.C Power Supply

Fuzzy Adaptive PI Controller for Direct Torque Control Algorithm Based Permanent Magnet Synchronous Motor

K.Vijaya Bhaskar,Asst. Professor Dept. of Electrical & Electronics Engineering

An Isolated Multiport DC-DC Converter for Different Renewable Energy Sources

2Azerbaijan Shahid Madani University. This paper is extracted from the M.Sc. Thesis

Principles of Adjustable Frequency Drives

Power Electronics. Exercise: Pulse Width Modulation Methods

Survey of Harmonics Measurements in Electrical Distribution Systems

CURRICULUM VITAE. 9. Academic Qualifications : Degree University Specialization Year. Jawaharlal Nehru Technological University, Hyderabad

SIMULATION AND ASSESSMENT OF SINGLE PHASE SEMI-Z-SOURCE INVERTER (S-ZSI)

Pulse Width Modulation (PWM) LED Dimmer Circuit. Using a 555 Timer Chip

Survey of Harmonics Measurements in Electrical Distribution System of a Technical Institution

MULTI-INPUT DC-DC CONVERTER FOR RENEWABLE ENERGY SOURCES

Lab 1. The Fourier Transform

Adaptive Equalization of binary encoded signals Using LMS Algorithm

ANN Based Fault Classifier and Fault Locator for Double Circuit Transmission Line

This document is downloaded from DR-NTU, Nanyang Technological University Library, Singapore.

LOW COST MOTOR PROTECTION FILTERS FOR PWM DRIVE APPLICATIONS STOPS MOTOR DAMAGE

METHODOLOGICAL CONSIDERATIONS OF DRIVE SYSTEM SIMULATION, WHEN COUPLING FINITE ELEMENT MACHINE MODELS WITH THE CIRCUIT SIMULATOR MODELS OF CONVERTERS.

High Power Factor Boost Converter with Bridgeless Rectifier

AMZ-FX Guitar effects. (2007) Mosfet Body Diodes. Accessed 22/12/09.

Control Development and Modeling for Flexible DC Grids in Modelica

A COMPERATIVE PERFORMANCE ANALYSIS OF BRIDGELESS PFC BOOST CONVERTER WITH THE CONVENTIONAL CONVERTER

A Design of DC/DC Converter of Photovoltaic Generation System for Streetcars

ENHANCEMENT OF FUNDAMENTAL RMS OUTPUT VOLTAGE OF 5-LEVEL CASCADED H-BRIDGE MULTILEVEL INVERTER USING MODIFIED MULTI- CARRIER PWM TECHNIQUE

isim ACTIVE FILTER DESIGNER NEW, VERY CAPABLE, MULTI-STAGE ACTIVE FILTER DESIGN TOOL

Experiment # (4) AM Demodulator

Mathematical Modeling and Dynamic Simulation of a Class of Drive Systems with Permanent Magnet Synchronous Motors

CHAPTER 2 POWER AMPLIFIER

PERSONAL DETAILS. Name : Anshul Agarwal Address : agw.anshul@gmail.com, anshul@nitdelhi.ac.in EDUCATION. MNNIT, Allahabad.

Microcontroller based PWM Inverter for Speed Control of a Three Phase Induction Motor

Phase-Control Alternatives for Single-Phase AC Motors Offer Smart, Low-Cost, Solutions Abstract INTRODUCTION

Solar Powered Smart Irrigation System

Tamura Closed Loop Hall Effect Current Sensors

MULTI-LEVEL INVERTER WITH DC LINK SWITCHES FOR RENEWABLE ENERGY SOURCES

A bidirectional, sinusoidal, high-frequency inverter design

DC/DC BUCK Converter for Renewable Energy Applications Mr.C..Rajeshkumar M.E Power Electronic and Drives,

TORQUE RIPPLES MINIMIZATION ON DTC CONTROLLED INDUCTION MOTOR WITH ADAPTIVE BANDWIDTH APPROACH

Design of Solar Power Optimizer And Eliminating Leakage Current In Multi-Level Inverter For PV Systems

Performance of 3-Phase 4-Wire Solid State Transformer under Imbalanced Loads

Transcription:

International Journal of Engineering Inventions e-issn: 78-7461, p-issn: 319-6491 Volume 4, Issue 1 [August 15] PP: 38-44 Single Phase Inverter with Selective Harmonics Elimination PWM Based on Secant Method Essam Hendawi 1, 1 Department of Electrical Engineering, Faculty of Engineering, Taif University, Kingdom of Saudi Arabia Electronics Research Institute, Egypt Abstract: Selective harmonics can be eliminated by controlling the inverter switches at optimized switching angles in single phase dc-ac inverters. These switching angles are estimated by solving a set of nonlinear equations. This paper presents a novel technique for solving these equations based on secant method. The proposed algorithm simplifies the numerical solution of the nonlinear equations, solves them fast and achieves convergence of solution at different starting vector of angles. The proposed method is applied with different modulation index and different number of equations, i.e. different number of switching angles to achieve the elimination of certain harmonics. High performance of the inverter is validated through simulation results. Keywords:Selective harmonics elimination, Secant method, Switching angles. I. INTRODUCTION Single phase dc-ac inverters are widely used in many applications such as AC motor drives, power supplies and uninterruptible power supplies [1]. Half bridge and full bridge topologies can be found but full bridge topology are more common. The output voltage of the inverter is required to be as close as possible to sinusoidal shape. Conventional sinusoidal pulse width modulation SPWM can be applied but selective harmonics elimination pulse width modulation (SHEPWM) technique is more advantageous than SPWM as listed in the literature [1-5].In SHEPWM, number of low order harmonics is selected to be eliminated based on the requirements of application. Then a set of nonlinear equations called transcendental equations are solved numerically to get the switching angles. These switching angles are applied to generate the control signals of the inverter switches. Equal area algorithm, Newton-Raphson algorithm, pattern search method and genetic algorithm can be applied to solve these equations [, 3, 6]. The main challenges are the starting vector of solution and the convergence of the solution. This paper proposes a novel technique for solving the transcendental equations based on secant method. The proposed algorithm simplifies the numerical solution of the nonlinear equations, solves them fast and achieves convergence of solution at different starting vector of angles. The switching angles are estimated using the proposed method. The switching angles are thenutilized to generate the control signals which are applied to unipolar single phase full bridge inverter. High performance of the inverter is validated through simulation results. II. PRINCIPLE OF SHEPWM INVERTERS Schematic of full bridge single phase inverter is shown in Fig. 1.The states of the four switches and the corresponding load voltage are summarizedin Table 1.Two techniques for selective harmonics elimination Fig. 1 Single phase inverter www.ijeijournal.com Page 38

Load voltage (V) Table 1 States of the inverter switches Switches state T 1 and T are on - T 3 and T 4 are off T 3 and T 4 are on - T 1 and T are off T 1 and T 3 are on - T and T 4 are off T and T 4 are on - T 1 and T 3 are off PWM can be applied; bipolar PWM technique and unipolar PWM technique [1]. In the bipolar PWM technique, the first two states in Table 1 are only utilized. The four states are applied in unipolar PWM technique which is more effective than bipolar PWM technique when harmonics elimination is required. Therefore unipolar PWM technique is applied in this paper. The output voltage of the unipolar PWM inverter is shown in Fig. with N switching angles (ɵ 1, ɵ 1, ɵ 1 ɵ N ), (N-1) harmonics can be eliminated. The output voltage can be represented in Fourier series as a function of the switching angles as v ωt = 4V s ( sin kωt π k=1,3,5 k V o V dc -V dc [cos kθ 1 cos kθ + cos kθ 3.. ] ) (1) Only odd harmonics exist while even harmonics do not exist since the output voltage is even function in its nature. The conditions for fully elimination of certain number (N-1) of odd harmonics are: N i=1 N ( 1) i+1 cos θ i π 4 M a = ( 1) k+1 cos nθ i = (3) k=1 Where M a is the modulation index which is defined as M a = V 1 / V dc, n = 3, 5, 7,.., N 1 and θ 1 < θ < θ 3. <θ N < 9 o For instance if it is desired the 3 rd,5 th,7 th,9 th, 11 th and 13 th harmonics, equations () and (3) can be written as: 7 k=1 7 i=1 ( 1) i+1 cos θ i π 4 M a = ( 1) k+1 cos nθ i = (4) (5) Where 'n' takes the values 3, 5, 7, 9, 11, 13. These will lead to the following seven equations which should be solved simultaneously: cos θ 1 cos θ + cos θ 3 cos θ 4 +cos θ 5 - cos θ 6 + cos θ 7 π M = (6-a) 4 a cos 3θ 1 cos 3θ + cos 3θ 3 cos 3θ 4 + cos 3θ 5 - cos 3θ 6 + cos 3θ 7 = (6-b) cos 5θ 1 cos 5θ + cos 5θ 3 cos 5θ 4 + cos 5θ 5 - cos 5θ 6 + cos 5θ 7 = (6-c) cos 7θ 1 cos 7θ + cos 7θ 3 cos 7θ 4 + cos 7θ 5 - cos 7θ 6 + cos 7θ 7 = (6-d) cos 9θ 1 cos 9θ + cos 9θ 3 cos 9θ 4 + cos 9θ 5 - cos 9θ 6 + cos 9θ 7 = (6-e) cos 11θ 1 cos 11θ + cos 11θ 3 cos 11θ 4 + cos 11θ 5 - cos 11θ 6 + cos 11θ 7 = (6-e) cos 13θ 1 cos 13θ + cos 13θ 3 cos 13θ 4 + cos 13θ 5 - cos 13θ 6 + cos 13θ 7 = (6-f) These nonlinear transcendental equations are solved numerically using the proposed algorithm by applying secant method. 8 () 6 4 - -4-6 -8.6.6.64.66.68.7.7.74.76.78.8 Fig. Output voltage of single phase full bridge inverter with unipolar PWM www.ijeijournal.com Page 39

III. PROPOSED ALGORITHM USING SECANT METHOD As a brief description of Newton-Raphson method to solve systems of non-linear equations, it is required to determine a Jacobian matrix J which is defined for N equations as follows: J = θ 1 θ θ 3 f f f θ 1 θ θ 3 θ N f θ N f N f N f N θ 1 θ θ 3 f N θ N (7) This Jacobian matrix is very complex since it needs a large number of partial differentiations especially when several number of harmonics are desired to be eliminated i.e. high value of N. Therefore very complex calculations will be needed and divergence of solution may occur. With the proposed method, each partial differentiation is replaced by the following equation: f i θ k f i θ 1,θ,.θ k +,..,θ N f i θ 1,θ,.,θ k,..,θ N (8) i and k take the values 1,,., N f / θ 3 represents element J 3 in the Jacobean matrix f θ 3 f θ 1, θ,. θ 3 +,.., θ N f i θ 1, θ,., θ 3,.., θ N Where Δθ is a small increment. The unknowns θ 1, θ, θ N are assigned initial values as: θ = [θ 1 θ θ 3. θ N ] T Flow chart that summarizes the proposed algorithm is given in Fig. 3. Equation (8) is applied to determine each element of the Jacobian matrix, then the elements are combined together to estimate the Jacobian matrix J as mentioned in (7). An update of the vector θ is carried out using the relation: θ n+1 = θ + J 1. f θ n The algorithm utilizes θ 1 as an initial vector for the next cycle which will repeat until the stopping criteria is achieved. this criteria is max f k (θ) ε 1, k = 1,,, N, max (θ k ) n+1 (θ k ) n ε, k = 1,,, N, Or the maximum number of iterations is exceeded which means divergence of solution and another initial solution vector θ should be selected. www.ijeijournal.com Page 4

Set initial vector of solution θ o and constant data Determine the Jacobean matrix J using equation (8) Update the solution vector θ Select another initial vector of solution θ o Use the new solution vector θ as an initial vector Is the conversion met? Yes No Stop and use the final vector θ to generate the control signals Yes Is the No. of iteration exceeded? No Fig. 3 Flow chart of the proposed algorithm IV. SIMULATION RESULTS The proposed method estimates the switching angles θ 1 θ θ 3. θ N. These switching angles are then utilized in an m-file in Matlab software program to generate the control signals for the inverter switches. Two Matlab m-files are built to carry out the algorithm at different number of harmonics that are desired to be eliminated. The first file is for constant data including dc voltage, desired output frequency and initial vectors of solution. The second file is for the proposed described algorithm. The dc source is 6 V and the load is R-L where R = 1 Ω and L = 4 mh. The increment Δθ is chosen as.5 rad The control signals are adjusted so that the load frequency is 5 Hz. Different cases are included from N = 3 to N = 11. The switching angles are given in Table. Selected cases are studied; N=7, N=1 and N=11. Load voltage and current for N=7, N=1 and N=11 are shown in Figures 4-6 respectively. The modulation index M a is adjusted at.85 The associated spectrum analysis of load voltage is presented in Figures 7-9 respectively.it is obvious the harmonics of order 6, 9 and 1 are eliminated for N=7, N=1 and N=11 respectively. The load current is very close to sinusoidal shape as N increases. To expect the switching angles using the proposed method and reduce the www.ijeijournal.com Page 41

Load current (A) Load voltage (V) Load current (A) Load voltage (V) Load current (A) Load voltage (V) iteration cycles especially with large values of N, variation of switching angles with N is given in Fig. 1. Therefore the initial values of the switching angles can be selected properly 8 6 4 - -4-6 -8.6.7.8.9.1.11.1 6 4 - -4-6.6.7.8.9.1.11.1 time (sec) Fig. 4 Load voltage and current, N = 7, M a =.85 8 6 4 - -4-6 -8.6.7.8.9.1.11.1 6 4 - -4-6.6.7.8.9.1.11.1 time (sec) Fig. 5 Load voltage and current, N = 1, Ma =.85 8 6 4 - -4-6 -8.6.7.8.9.1.11.1 6 4 - -4-6.6.7.8.9.1.11.1 time (sec) Fig. 6 Load voltage and current, N = 11, Ma =.85 www.ijeijournal.com Page 4

Magnitude based on "Base Peak" - Parameter Magnitude based on "Base Peak" - Parameter Magnitude based on "Base Peak" - Parameter 5 45 4 35 3 5 15 1 5 1 3 4 5 6 7 8 9 1 Order of Harmonic Fig. 7 spectrum analysis of load voltage, N = 7, Ma =.85 5 4 3 1 1 3 4 5 6 7 8 9 1 Order of Harmonic Fig. 8 spectrum analysis of load voltage, N = 1, Ma =.85 5 45 4 35 3 5 15 1 5 1 3 4 5 6 7 8 9 1 Order of Harmonic Fig. 9 spectrum analysis of load voltage, N = 11, Ma =.85 www.ijeijournal.com Page 43

Switching angles 9 8 7 6 5 4 3 1 3 4 5 6 7 8 9 1 11 N Fig. 1 variation of switching angles versus N V. CONCLUSION Selective harmonics elimination is achieved by adjusting the switching angles of the inverter. The switching angles have been estimated using the proposed algorithm which is based on secant method. The switching angles are utilized to generate the control signals of the inverter switches. Simulation results verify the effectiveness of the proposed algorithm. Selective harmonics in the inverter output are eliminated and the load is very close to sinusoidal shape. The proposed algorithm can be applied for any number of harmonics. A guide of the initial vector of switching angles is proposed to minimize the iterations especially with large number of harmonics. REFERENCES [1] Muhammad H. Rashid, Power Electronics Handbook, nd Edition, 7,Elsevier. [] K. Keerthivasan, M. Narayanan, V. SharmilaDeve and J. Jerome, Estimation of Optimal Single phase Inverter s Switching angles Using Pattern Search Method, International Conference on Computer Communication and Informatics (ICCCI -1), Jan. 1 1, 1, Coimbatore, India. [3] Tamer H. Abdelhamid and Khaled El-Naggar, Optimum Estimation of Single Phase Inverter s Switching Angles Using Genetic Based Algorithm, Alexandria Engineering Journal, 5, Vol. 44, No.5, pp 751-759. [4] J. E. Denis and H. Wolkowicz, Least change secant methods, sizing, and shifting, SIAM J. Numer., 1993. Anal., vol. 3, pp. 191 1314 [5] Muhammad H. Rashid "Power Electronics (circuits, devices and applications)", 1988, 1 st Edition,Prentice-Hall. [6] J. W. Chen and T. J. Liang, A Novel Algorithm in Solving Nonlinear Equations for Programmed PWM Inverter to Eliminate Harmonics, 1997, 3 rd International Conference on Industrial Electronics, Control and Instrumentation conference IECON. www.ijeijournal.com Page 44