OPERATORS MANUAL. Supera Table Top Anesthesia Machine. Models: M3000 (All shown with optional equipment)

Similar documents
Understanding Anesthetic Delivery Systems Dean Knoll, CVT, VTS (Anes.) Anesthesia Technician Supervisor University of Wisconsin Madison, WI May 2003

VANGUARD A OPERATOR S MANUAL PORTER. FM-952 Rev. E 7/07

Operating Instructions & Maintenance Guidelines for Precision Vaporizers

NSI DDR DIMMING RACK POWER DISTRIBUTION UNIT

Principles of the Anesthetic Machine

Veterinary Clinics and Hospitals

Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield, PA USA. REF Rev. L

Start Saving Today With The Pureline M6000 Anesthesia Machine With Oxygen Concentrator

How To Install A Power Supply (Uplast) With A Battery Pack

BroadBand PowerShield. User Manual

MODEL G300 BRAKE BLEEDER

123 Industrial Loop Road Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

Installation Operation Maintenance Troubleshooting

Benchtop Computer Monitor Generator

Installation Operation Maintenance Troubleshooting Version 2.1, Apr/09 DAYTONA

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

NITROUS TRANSFER PUMP INSTRUCTIONS

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

Ozone Generator Manual

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN A

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

MTX-D, Oil Temperature/Pressure Gauge

Table of Contents TO OPERATE THE 12.0 VOLT POWER PACK: THIS OPERATES ONLY OFF THE UNIT S RECHARGEABLE BATTERY, NOT OFF YOUR VEHICLE S BATTERY.

VK-250 WARRANTY REGISTRATION FORM

Perseus. Owner s Manual. Vacuum Tube Preamplifier. Rogue Audio, Inc. 3 Marian Lane Brodheadsville, PA Issue date: 02/01/06

Porter Instrument Division

MODEL # Introduction

INSTALLATION MANUAL MODEL RP-100

Triple Expansion Chassis

Ceiling Mount Air Handler Manual

B150 Series Commercial Brewer. Direct Plumb Kit

4 in 1 Air Compressor

24.2L M.A.N. V12 Engine Module

1 / 4 IN. FFL x 4 FT. 9 IN. 1 / 2 IN. ACME x 4 FT. 9 IN. Gauge Accuracy +/-2% Set includes Quick Disconnect Valves

ENGLISH USER S MANUAL. compact handheld 1D/2D code scanner

Tablet 30W Tablet 92W

FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL

SALTER AIRE Plus COMPRESSOR Model 8350 / 8352 / Instruction Manual. Page 1 of 9

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Your safety and the safety of others are very important.

Owner s Manual. Pelican Custom Premium WHWF 1865/2162

Installation Manual DIAPHRAGM WELL TANK

L /96. Haldex INSTALLATION INSTRUCTIONS HALDEX PURE AIR PLUS EXTENDED PURGE KIT (DQ6027) HEAVY DUTY CANISTER KIT (DQ6028)

Model SRMD Setra Remote Monitoring Display

Triple Threat 3-in-1 Game Table 3 IN 1 GAME TABLE

OWNER S MANUAL DRAINVAC ATOMIK PRINTED APRIL

INSTANT HOT WATER RECIRCULATING SYSTEM

Mini-led spotlight with magnetic base

DiscovR R134a Refrigerant Identifier

Take-2 by Nel-Tech Labs, Inc. Installation & User Manual

XTEND 900 MHZ WIRELESS MODEM For use with VEEDER-ROOT EMR³ DATALINK INSTALLATION INSTRUCTIONS Manual , Rev. B

Aespire View. User s Reference Manual. Software Revision 6.X

High Efficiency Vaporizing System and Highly Durable Heaters Ensure 25% Increased Output.

Ultraviolet Germicidal Lamps Owner s Manual MODELS 1910 & 1930

For over 40 years, the leader in. nitrous oxide. equipment technology.

MODEL VG08008 CONTENT PACKING LIST / TOOLS NEEDED PANEL DIMENSIONS FITTINGS / TECHNICAL DATA WALL/CORNER INSTALLATION CARE AND TROUBLE SHOOTING

Cylinder Leak- Down Tester

PAINT SPRAY GUN WASHER

Instructions. Complete RPS 2900 Pump Kit for RoadLazer RoadPak Line Striping System 3A1304A ENG. Pressure Relief Procedure.

User Guide. HDMI Active Cable Extender. DVI-7370c

Scope: Applies to the various anesthesia vaporizers used to deliver a known concentration of vaporized liquid. Sample. Type Interval Time Required

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

PAPER SHREDDER PRS-F-01 USER MANUAL

ATS Overhead Table Shelf System INSTRUCTION MANUAL

National- Spencer Inc.

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

MTX-D, Boost/Shift Gauge

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual


OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

BUB-110B. Portable Power Pack. Compact USB Battery Charger for up to 5 Smartphones and Mobile Devices. User Manual

USER MANUAL. Model U ForeFront Alarm Card SALES OFFICE (301) TECHNICAL SUPPORT (301) An ISO-9001 Certified Company

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

MF636 USB Modem. Quick Start User Guide

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

User manual. Your best protection against theft and loss. (Android) Made for

SURROUND MASTER. User Manual 1.0. English. Copyright 2012 Involve Audio


LST In-Dash Digital Sonar Gauge. Installation & Operation Instructions

How To Service A Paper Shredder

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Air vacuum pump with r134a & r12/22

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS

DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS

Chevy Bel-Era

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Installation and Operating Manual Model F1800C Model F1800PG Model F1802C Model F1802PG Model F1806C Model F1806PG

American Dish Service

User Manual. RK-2d / RK-2t. dedicated KVM switch and rackmount screen technology. Designed and manufactured by Austin Hughes

Hydraulic control unit series

Transcription:

OPERATORS MANUAL Supera Table Top Anesthesia Machine Models: M3000 (All shown with optional equipment) Supera Copyright 2012

Examination and Preparation for Use Thank you for ordering an Supera Anesthesia Innovations anesthesia machine! We are delighted to have you as a Supera Anesthesia Innovations customer and want you to be completely satisfied with your purchase. Please inspect the contents of your order to see if everything is as you expected. Should anything not be exactly right or if anything was damaged in shipping, please contact your sales representative right away for help. Our goal is to make your new anesthesia machine as easy to use and care for as possible. This device is meant to be operated under the normal surveillance and control of a veterinarian trained in its use. However, you need to know more about this device than just how to operate it. Please read this manual in its entirety before using the anesthesia machine. If you have any comments or questions, we welcome the opportunity to address them. Please contact us directly at 877 620 1500. Thank you! Brian Lawson President, Supera Anesthesia Innovations Proudly 100% American Made!

TABLE OF CONTENTS Chapter 1: Machine Features Oxygen supply Circuits Waste gas evacuation Chapter 2: Technical Information Diagram and Part Numbers Ordering information Warranty /Return Machine & Service notes

Chapter 1: Machine Features Shown with optional items: TEC 3 Vaporizer Induction Chamber Multi-Port Manifold TEC 3 Vaporizer - New VAP3000 - Isoflurane VAP3100 - Sevoflurane Oxygen Flow Meter Multi-Port Manifold RES535-2 port RES536-4 port Induction Chambers RES644 2.1 liter 8x8x3 mice RES645 3.3 liter 8x8x5 mice/rat RES646 7.4 liter 14x10x5 mice/rat Non rebreathing circuit RES500 Evacuation tubing EVC537

Common Machine Components Oxygen Flow Control located on the flowmeter, the flow control adjusts the precise amount of oxygen entering the anesthesia machine. Common Gas Outlet - a 15mm female connector located at the outlet of the vaporizer and is the port by which the mixture of anesthetic gases is delivered to the rest of the anesthesia system. Flowmeter measuring device indicating the precise amount of oxygen flowing into the anesthesia machine. Encased within the flowmeter is a glass tube that contains a small ball that rises as gas flows into the system. Non-rebreathing System or Circuit includes anesthetic gas supply tube, reservoir tube, reservoir bag and bag bleed valve. This system is recommended for patients under 10 lbs. Oxygen Flush Valve a small, push button valve located by the flowmeter that acts to flush oxygen through the system, bypassing the vaporizer. The oxygen flush contains a safety device that restricts flow. Vaporizer a device that vaporizes an anesthetic agent from a liquid to a gaseous state. The resulting gas is precisely delivered at a specified percentage concentration, independent of temperature and flow rate.

Oxygen Supply DISS Male Thread Green oxygen line connects here. Attach the green oxygen hose to the DISS male thread. NOTE: An optional quick disconnect fitting can be installed. Call for options. 877-620-1500 WARNING! NEVER USE PETROLEUM BASED PRODUCTS ON OR NEAR THE OXYGEN SUPPLY.

Circuits CIR518 - Non-Rebreathing Modified Jackson-Rees The Non rebreathing system connects to the common gas outlet of the anesthesia machine. 1. Disconnect the common gas outlet from the rebreathing head. (quick disconnect fittings) 2. Plug the 15mm male connector from the non rebreathing system into the common gas outlet of the anesthesia machine. 3. Connect the blue exhaust port on the bag of the non rebreathing system to the 19mm blue evacuation tubing connected to the waste gas interface device or to any other waste gas evacuation device (outside air, F air canister, etc.)

Circuits RES500 - Rat & Mouse non-rebreathing circuit with 19 or 22mm evac port 19mm/22mm waste gas port 15mm male fresh gas RES505 (optional item) waste gas interface 22mm evacuation tubing Connect the 15mm fitting to the common gas outlet of the machine (output of vaporizer) Connect the 19mm/22mm port to the evacuation system.

Waste Gas Evacuation Options RES505 - Waste gas interface for active suction EVC555 - F-AIR Charcoal Canister Kit EVC554 - Replacement canister RES505 (optional item) waste gas interface RES500 connected to the F-AIR canister F-AIR canister kit installed on M3000 attached to CIR518 circuit. The F-AIR canister will remove the waste gas from the anesthesia machine for approximately 8-12 hours. After that time, the canister is replaced. F Air Canister Bracket - Optional Attached to the back rail of the bracket with screw provided

Warranty / Return Policy Supera Anesthesia Innovations warrants that each product or part shall be free from defects in workmanship and materials, under normal use and with appropriate maintenance, for 10 (ten) years from the date of purchase. For plastic, rubber and disposable parts or items, Supera Anesthesia Innovation warrants only that each such part and item shall be free from defects in workmanship and materials at the time of delivery. This warranty shall be void for any product that has been altered, defaced or removed from the original Supera Anesthesia Innovation product. Supera Anesthesia Innovation shall not be liable for any damage, injury or loss arising out of the use of the product, whether as a result of a defect in the product or otherwise, if, prior to such damage, injury or loss, the product was (1) damaged,misused, or misapplied; (2) repaired, altered or modified by persons other than Supera Anesthesia Innovation; (3) not installed in strict compliance with the applicable codes and ordinances; (4) not installed by Supera Anesthesia Innovation or an authorized Supera Anesthesia Innovation dealer. UNDER NO CIRCUMSTANCES SHALL Supera Anesthesia Innovation BE LIA- BLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES AS THOSE TERMS ARE DEFINED IN THE UNIFORM COMMERCIAL CODE. All items returned for service or repair are the responsibility of the customer. Proper packing methods should be used in returning items to Supera Anesthesia Innovation.

DOCUMENTATION Date purchased: Purchased from: Machine serial number: Vaporizer serial number: Machine service information Service Date: Service information: Service Date: Service information: Service Date: Service information: