DMX512 Over Broadband Powerline Communication Transceiver Module. Homeplug based DMX512 Adaptor. User Manual. LinkSprite Technologies, Inc.

Similar documents
Using Xbee in Serial Communication

Step-by-Step Tutorial For Using LinkSprite UART- WIFI Module Model LS_UART_WIFI

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

A RF18 Remote control receiver MODULE

Follow these steps to prepare the module and evaluation board for testing.

PLI-3310 HomePlug Pro Power Bridge

USR-TCP232-T Hard Version: V2.0 Doc Version: V

(USR-TCP232-T, USR-TCP232-2) (USR-TCP232-S, USR-TCP232-D) (USR-TCP232-24, USR-TCP ) (USR-TCP , USR-TCP ) File version: V3.

Powerline Network. RPL-85 User Manual RPL-85. Powerline Ethernet Bridge V All rights reserved. Page 1

RN-XV-RD2 Evaluation Board

Quick Installation. A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding. Quick Installation

AV1200 TL-PA8030P KIT. 3-Port Gigabit Passthrough Powerline Starter Kit. Highlights

RC2200DK Demonstration Kit User Manual

XPort Universal Demo Board User Guide

Web Site: Forums: forums.parallax.com Sales: Technical:

ALL-USB-RS422/485. User Manual. USB to Serial Converter RS422/485. ALLNET GmbH Computersysteme Alle Rechte vorbehalten

Single channel data transceiver module WIZ2-434

NMEA 0183 INSTALLATION AND OPERATING GUIDELINES

Building a Basic Communication Network using XBee DigiMesh. Keywords: XBee, Networking, Zigbee, Digimesh, Mesh, Python, Smart Home

Software User Guide UG-461

Programming Flash Microcontrollers through the Controller Area Network (CAN) Interface

Wifi Web Server Module w TF Socket User s Guide

Modbus Communications for PanelView Terminals

1-Port R422/485 Serial PCIe Card

RN-WIFLY-EVAL-UM. WiFly Evaluation Kit Roving Networks. All rights reserved. RN-WIFLY-EVAL-UM Version 1.32r 10/9/2012 USER MANUAL

2015/02/07 05:41 1/23 WIZ550WEB Users' Guide

PCAN-MicroMod Universal I/O Module with CAN Interface. User Manual. Document version ( )

1 Serial RS232 to Ethernet Adapter Installation Guide

GETTING STARTED GUIDE

s!nus-elektrotechnikai bt. Industrial IT & Automation

MCB3101 (Class I) WiRobot Serial Bluetooth Wireless Module User Manual

EDI Distributor Control Interface Wiring and Setup Instructions

Setting Up the ZigBee Ethernet Gateway

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

Process Control and Automation using Modbus Protocol

TOSR0X-D. USB/Wireless Timer Relay Module. User Manual. Tinysine 2013 Version 1.0

Installation. Powerline 500 Model XAVB5221

Auxiliary equipment for communication with the EuroProt protective devices

NetProbe Lite. Web Based 8 Channel Sensor Collector. User Manual. Version 1.2

The GV-I/O Box 8 Ports provides 8 inputs and 8 relay outputs, and supports both DC and AC output voltages.

How To Use An Adh8012 Gsm Gprs Module With A Gsm (Gsm) Gpros (Gsp) Gpls (Geo) Gsp (Gpl) Gs

Bluetooth to Serial Adapter

Guangzhou HC Information Technology Co., Ltd. Product Data Sheet

Turbo 85 Mbps Powerline Ethernet Adapter Model # APL8512. User s Manual. Ver. 1A

Model 5511 Filler Controller User s Manual Version 1.1 October 2011

1.Eastron SDM220Modbus Smart Meter Modbus Protocol Implementation V1.0

TCP/IP Converter DDS EX-9132 Operation Manual for 8051 Series

Wireless Communication With Arduino

GV-Data Capture V3 Series User's Manual

Eliminate Risk of Contention and Data Corruption in RS-485 Communications

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

NetPlug200 Nano.

Voice Over Internet Protocol (VoIP) Configuration

The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages.

Powerline 1200 User Manual

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

Advanced Data Capture and Control Systems

User s Manual TCP/IP TO RS-232/422/485 CONVERTER. 1.1 Introduction. 1.2 Main features. Dynamic DNS

HAC-LM Series Low Power Data Radio Module

2012 uptimedevices.com

WICE-SPI Hardware Operation Manual

Bluetooth UART/RS232 Module

Communication Setup Application Note

DK40 Datasheet & Hardware manual Version 2

POS Integration. Prepared by: Binh Nguyen

M72. Quectel Cellular Engine. EVB User Guide M72_EVB_UGD_V1.0

KTA-223 Arduino Compatible Relay Controller

Technical description MX-1 VB Edge

Guangzhou HC Information Technology Co., Ltd. Product Data Sheet

Guangzhou HC Information Technology Co., Ltd. Product Data Sheet

3.1 RS-232/422/485 Pinout:PORT1-4(RJ-45) RJ-45 RS-232 RS-422 RS-485 PIN1 TXD PIN2 RXD PIN3 GND PIN4 PIN5 T PIN6 T PIN7 R+ PIN8 R-

Table of Contents. Hardware Installation...7 Push Button Security Using the Setup Wizard Configuration...11 Main Security...

HomePlug Turbo Powerline Ethernet Bridge. User Manual

F2103 GPRS DTU USER MANUAL

CAM-VGA100 User Manual

INTRODUCTION FEATURES OF THE ICM

MBP_MSTR: Modbus Plus Master 12

TPM Product Type 107-D162-NNT 48-channel digital input and 16-channel digital output module with pluggable terminal

RN-131-PICTAIL & RN-171-PICTAIL Web-Server Demo Application

ALL0237R. Wireless N 300Mbit Access Point/Repeater. User s Manual

Ethernet Adapter Owner's Manual

ETHERNET WEATHER STATION CONNECTIONS Application Note 33

A DIY Hardware Packet Sniffer

Quectel Cellular Engine

Quick Installation Guide Network Management Card

CONCEPT1 RS232 COMMUNICATION

T3 Mux M13 Multiplexer

DECT Module UM-9802 Datasheet

Serial Communications / Protocol in AirTest Products

HARDWARE MANUAL. BrightSign HD120, HD220, HD1020. BrightSign, LLC Lark Ave., Suite 200 Los Gatos, CA

AC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134

DSA-1000 / PRT-1000 Device Server / Thermal Printer

SMS based remote control system

FBs-CM25/CM55/CBE. Ethernet Module. User s Manual

EZ-View Network Communications Guide

XBee-PRO 868 RF Modules

CENTRONICS interface and Parallel Printer Port LPT

FSW-0505TX/0805TX 5/8 Port SOHO 10/100Mbps NWay Switch FSW-0505TX FSW-0805TX. 5/8 Port SOHO 10/100Mbps NWay Switch. User s Manual. (Revision 1.

2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide

Using installed Fieldbus Wiring to carry Ethernet Communications

Transcription:

DMX512 Over Broadband Powerline Communication Transceiver Module Homeplug based DMX512 Adaptor User Manual LinkSprite Technologies, Inc June 2011 www.linksprite.com

1. Introduction LinkSprite's broadband powerline communication module has 5Mbps throughput on the powerline. The DMX512 PLC adaptor replaces the DMX512 cable by the powerline (DC or main AC power). AT command are used to configure the domains of different nodes so that DMX512 stream can be configured to different domains. Hardware included: Boardband powerline communication module RS485 DIP card RS485 to DMX512 cable 2 Features A LinkSprite DMX512 to PLC-Transceiver AC and DC powerline Communications Fully transparent mode, plug and play coming out of the box without the need to do any programming. Homeplug 1.0 5Mbps throughput on the power line Built-in error correction codes. AT commands used for advanced configuration. RoHS LinkSpriteTechnologies, Inc. 2 www.linksprite.com

3 Specifications Product name High Speed DMX512 to PLC Transceiver Module (Homgplug DMX512 adapter) Interface Communication Voltage Supply Voltages Modulation Error Correction Line DMX512 230VAC/50Hz 110VAC/60Hz 0-400V DC 5V, 3A DC OFDM (Homeplug 1.0 Compatible) FEC(Forward Error Correction) Data rate on Powerline Transmission distance 5Mbps (throughput) 300 feets(no repeater) Support nodes number 65535 LED Power Line Activity LED system LED serial port LED LinkSpriteTechnologies, Inc. 3 www.linksprite.com

4 Applications DMX512 lighting control to replace DMX512 cable. 5 Connectors Description The AC or DC powerline line can be connected to the L/N connector denoted on the above picture. The 5V/3A DC power supply is connected to the white/black connector, or the DC barrel connector on the new board. LinkSpriteTechnologies, Inc. 4 www.linksprite.com

6 LED LED1 LED2 LED3 LD1 LD2 LD3 LD4 LD5 LD6 Powerline Collision Powerline Activity Powerline Link Ethernet Link Ethernet Full/Duplex LED Ethernet Link UART receiving activity UART sending activity When used with LinkSprite Zigbee module, ON means not zigbee network not formed or joined, OFF means formed zigbee network or joined network LD7 When used with LinkSprite Zigbee module, ON means not binding, OFF means binding LinkSpriteTechnologies, Inc. 5 www.linksprite.com

7 Definition of DIP Pins DMX512 Over Wide Band Powerline Communication Transceiver Module LinkSpriteTechnologies, Inc. 6 www.linksprite.com

8 Interface Card Socket Definition and Layout The pin layout of interface cards is compatible with Xbee module from Digi (www.digi.com). The socket on the PLC-UART motherboard can be used to receive any interface card with the pin out shown below: Pin assignment of the interface card socket: Pin # Name Direction Description 1 VCC - 3.3V Power supply 2 DOUT Output UART Data Out 3 DIN Input UART Data In 4 EX4 Depending on model of daughter card Route daughtercard final interface signal back to mother board, and to the DIP pins to user s board 5 RESET Input Module Reset 6 EX3 Depending on model of daughter card Route daughtercard final interface signal back to mother board, and to the DIP pins to user s board 7 EX2 Depending on model of daughter card Route daughtercard final interface signal back to mother board, and to the DIP pins to user s board 8 EX1 Depending on model of daughter Route daughtercard final interface signal LinkSpriteTechnologies, Inc. 7 www.linksprite.com

card back to mother board, and to the DIP pins to user s board 9 SLEEP Input Pin Sleep Control Line 10 GND - Ground 11 Unused - - 12 Unused - - 13 Unused - - 14 Unused - - 15 Associate Output Associated Indicator 16 Unused - - 17 Unused - - 18 Unused - - 19 Unused - - 20 Unused - - 9. Command Mode Description of AT mode Enter into AT mode After power on, PLC DMX512 adapter will enter into AT mode, and will stay in AT mode until DMX512 signal is detected. If there are no character A (or a) in 8 seconds, the module will reboot. If there is, but no complete command in 20 seconds, the module will reply with a timeout message and clear the previous command. LinkSpriteTechnologies, Inc. 8 www.linksprite.com

Description of AT commands DMX512 Over Wide Band Powerline Communication Transceiver Module Command Description ATDA Set domain address or check domain address (if no argument is followed). Default value: 0x8888 ATNA Set node address or check node address (if no argument is followed). Default value: 0x8888. ATBD Check or set baud rate of AT mode. The supported baud rates: 1200,2400, 4800, 9600, 19200, 38400, 57600, and 115200. The default is 9600. ATDB Check or set data bits of AT mode. 5-8 data bits. Default is 8. ATPA Check or set parity bit of AT mode. The options are e, o, n. Default is n. ATHA Check the MAC of the device or set the destination MAC address (default: FF-FF-FF-FF-FF-FF (broadcasting mode) ATSN Check or set Serial number ATDN Set or check destination serial number ATRS System Reset If no argument is followed after command, it will report the current setting. There must be at least one spacing between command and argument. The spacing within argument doesn t make difference. Addressing 1. The ATHA command can be used to check the MAC address of device itself. When argument is used, it is used to set the destination MAC address. (FF-FF-FF-FF-FF-FF means broadcasting). The total length if 17 includes the delimiter -. 2. Description of serial number: the serial number used in ATSN command consists of 32 bits. The upper 16 bits are domain address, while the lower 16 bits are node address. The definition of DN is same LinkSpriteTechnologies, Inc. 9 www.linksprite.com

as that of SN, but DN has only domain address portion. If the MAC address of source device is a broadcast address and the DA portion of the source DN matches DA portion of destination SN, they can communicate. MSb 16bit domain(0000-ffff) 16bit node(0000-ffff) LSb (SN/DN diagram) Examples Broadcast mode: To put the device into broadcast mode, MAC addresses of all the devices must be set to broadcast mode (FF-FF-FF-FF-FF-FF). If DN of all devices also set to (0xFFFFFFFFFFFF), all devices are in broadcasting mode. Otherwise, it only broadcasts within the same domain where the DN of the source is same with the DN of the destination s SN. LinkSpriteTechnologies, Inc. 10 www.linksprite.com

LinkSprite Technologies, Inc. 1067 S Hover St, Unit E-186 Longmont, CO 80503 (Voice) 720-204-8599 (Email) sales@linksprite.com http://www.linksprite.com LinkSpriteTechnologies, Inc. 11 www.linksprite.com