- SMART TUNE- PID CONTROL STEP PROGRAMMER, UP TO 90 PROGRAMS, 5 PID GROUPS - TRACKING AND GUARANTEED SOAK FUNCTIONS - REAL TIME CLOCK AND

Similar documents
Process controller Setpoint programmer 1/16 DIN - 48 x 48 mm gammadue series M5 line

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

Auto-tune PID. Temperature Controller BRAINCHILD FEATURES

Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

MLC TM Maximum Productivity and Versatility for Control without Compromise!

Controller Automation, Model II+

HONEYWELL DC 1010 / / 1040 DIGITAL CONTROLLER PRODUCT MANUAL /02

THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit , March 2012

+ A B V B NO NC V COM PV PV

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

Temperature Controller CD401/CD901/CD701/CD501/CD100/CD101 Instruction Manual

CPA PC-Programmable Current/Voltage and RTD/Thermocouple Limit Alarm Trips

PID Microprocessor temperature controllers CTD43 - CTD46 - CTH46

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Electronic Control Devices The European Product Catalogue 2007

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Model: DC-A2IO Advanced HVAC Controller

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

DC1000 Series General Purpose UNIVERSAL DIGITAL CONTROLLERS

Digital Pressure Measuring Instrument MDR480

Wahl C50 Calibrator FEATURES

Safety technique. Emergency stop module BO 5988 safemaster

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Electronic Control Devices The European Product Catalogue 2007

HERZ-Thermal Actuators

DC DC DC DC1040

NOW A PRODUCT! 1 /4 DIN PROCESS CONTROLLER. Single Loop Profile Controller (optional) NEMA 4X Front Panel PowerTune. The Interface Solution Experts

Power Meter Series 700

Process controller with PROFIBUS DP and Modbus Master/Slave 1/8 DIN - 48 x 96 mm gammadue series X5 line

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Duct Humidity Transmitter

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

SYL-2372 PID TEMPERATURE CONTROLLER INSTRUCTION MANUAL Version 1.4 (May 2016)

J TB/TW Temperature limiter, temperature monitor

PRODUCT PROFILE FEATURES

NC-12 Modbus Application

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Dyeing Programmer DP - 01

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Process controller with PROFIBUS DP and Modbus Master/Slave 1/4 DIN - 96 x 96 mm gammadue series Q5 line

Multifunction devices

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Thyristor-controlled power supplies and battery chargers

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Heat-Cool temperature controller 1/8 DIN - 48 x 96 mm gammadue series X1 line

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

M2M The measure of efficiency

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

HFE1600 Series 1600W 1U Hot Swap Front End Power Supplies

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

650W Single Output Power Supply

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

PIEZOMETER AIRFLOW MEASURING RING

1.44 kw Programmable DC Power Supplies XLN Series

Contents. Document information

MasterINTERFACE 39 Series - Relay interface modules

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Controls for fan coil units and cassettes

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Nokeval. User's Manual Models 301 / 302 / 305

UDC2500 Universal Digital Controller. Specification. Overview. Features. Analog Inputs /04 Page 1 of 13

Preliminary. Dual-line FLOW rate/totalizers. Pr ovu Model PD6200 Analog Input. Pr ovu Model PD6300 Pulse Input. Analog Inputs.

#1381-3, Juan-dong, Nam-gu, Incheon, Korea TEL:(82-32) FAX:(82-32)

Temperature & Humidity SMS Alert Controller

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

MC Series Drives. Flexible, simple, rugged, robust! Phone: Fax: Web: info@actechdrives.

Durant PGM. For Sales and Support, Contact Walker EMD Toll-free: (800) Tel: (203) Fax: (203)

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

MasterINTERFACE 39 Series - Relay interface modules

JUMPFLEX 857 Series ma V ma. Transducers / Relay and Optocoupler Modules

Bulletin 150 SMC Flex Smart Motor Controller Specifications

The E5CN provides communications or event input functionality when mounted with one of the following Option Boards.

Speed Control Relays SX2

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

For a complete explanation of all the functions and configurations available please refer to the SC6006: Manual of operation.

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

DCS Series 1 kw, 1.2 kw, & 3 kw

DC Electronic Loads 8500 series

Manual Ranging MultiMeter

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

IntesisBox KNX LG Air Conditioning

Energy Management Energy Meter Type EM23 DIN

Online Infrared Flue Gas Analyzer Gasboard 3000

Temperature Transmitters ZTT series

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Transcription:

ADVANCED PROGRAMMER - CONTROLLERS - SMART TUNE- PID CONTROL - 200 STEP PROGRAMMER, UP TO 90 PROGRAMS, 5 PID GROUPS - TRACKING AND GUARANTEED SOAK FUNCTIONS - REAL TIME CLOCK AND CALENDAR - UNIVERSAL, 3 WIRE- TC, RTD AND INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION (ma) OUTPUTS - 4x EVENT OR ALARM OUTPUTS (10 OPTIONAL MKP) - 3x LOGIC INPUTS (8 OPTIONAL MKP) - OUTPUT ISATION - 24V DC TRANSMITTER POWER SUPPLY - RS 485 MODBUS SERIAL COMMS OPTION - OPC BASED GRAPHICAL CONFIGURATION SOFTWARE

OVERVIEW The MKP/ PKP is a versatile high performance ramp/soak programmer. A wide range of hardware combinations and special software functions make these instruments highly flexible and suitable for a wide range of advanced control and profiling applications. Designed to offer outstanding control performance and provide a comprehensive solution for a wide variety of applications such as furnace and and atmosphere control, environmental and growth chambers and time activated flow and level control. Requiring precision heat/cool control and process protection alarms. The programmer facility has storage capacity of 200 segments in up to 90 programs. Each program may be linked for maximum pattern storage flexibility. The custom display provides a complete view of the process. Universal- thermocouple, RTD or process linear coupled with a responsive, SMART auto-tuning PID control algorithm that is equipped with special functions including, soft start and non-linear cooling. A complete set of process protection alarm functions, high and low limit, band and deviation are included. Optional features include: CT input- HBD OFD, Servo valve positioner, (ma) linear control or retransmission outputs, ModBus communication interface option,up to 10 event inputs and 8 event outputs. CONFIGURATION PROGRAM The configuration software simplifies the instrument configuration, parameter adjustment and program editing. A complete instrument configuration may be saved from, and downloaded to the instrument providing a quick and reliable method to maintain instrument settings. THE MKP AND PKP PROGRAMMER Program format Up to 90 simple programs are available, each program may contain: - up to 99 segments - up to 14 timed events Program segments options Up to 200 segments are available, for each segment it is possible to: - set duration in hours and minutes (up to 99hours and 59minutes) or in minutes and seconds (up to 99minutes and 59 seconds) - apply up to 5 different PID sets - apply a wait band (10 available) - apply one or more break events Linked programs - Up to 9 programs may be linked Break events With this function it is possible to associate to each segment the state ON or OFF of one or more outputs selected as break event (ex. OUT 10). LINKED PROGRAMS set point Program 7 BRAK EVENTS AND TIMER EVENTS Process Variable 1 Soak 1 2 Soak 2 3 Time Program 20 1 OUT 19 OUT 10 Program Step 1 Step 2 Step 3 Step 4 Step 5 ON OFF ON OFF ON ON OFF OFF ON OFF Time set point 1 Soak 1 2 Soak 2 3 1 4 Soak 1 Soak 3 5 2 Soak 2 Soak 5 1 6 Time Soak 1 Soak 5 2 7 Program 5 Time Linked program L1 Time

Guaranteed Soak Guaranteed Soak assures the product receives the desired process time at all program segments. MKP.PKP CLOCK CALENDAR The inbuilt, lithium (10 year life) battery backed real time clock facility enables the program to be started or stopped on a pre-set time or day of the week. WAIT AND GUARANTEED SOAK FUNCTIONS Up to 10 program wait bands may be set. If the process variable is outside the programmed wait band, the ramp in progress will be stopped. The program will restart when the process variable is returned inside the wait band. During a program soak segment the material is maintained at the temperature set for the entire programmed time. If the process variable is outside the programmed wait band, the soak time will be stopped. The soak time will restart when the process variable is returned inside the wait band. Each segment may have different wait bands. Tracking If the process is interrupted during a ramp, the controller will continue the ramp after the process stablizes at the target set point valve. Set point Set point Suspension of soak time Temp Temp SPLIT RANGE OF THE OUTPUT Allows two different physical outputs, (two different actuators) to be driven from the same control output. Bias and gain settings for each output may be independently set to achieve optimal control precision. This feature may be used to improve flow control and reduce energy consumption when using two control valves or variable speed pumps of different size, as illustrated in the diagram. Power output Power output 100% 100% Measure Output calculated by PID algorithm Output A Output B 100% Out A Out B Measure Output calculated by PID algorithm Output A Output B Real Output (it is the sum of the two outputs) Measure SQUARE ROOT EXTRACTION ON THE MEASURED VALUE A square root extraction function is available to calculate flow with a standard DP transmitter without additional signal conditioning hardware.

PREPROGRAMMED OUTPUT CHARACTERISTICS Maximum flow percentage 100% 80% 60% 40% Quick opening Linear 20% Equal Percentage 0% 20% 40% 60% 80% Rated travel percentage 100% Quick opening and equal percentage valve flow characteristic are automatically compensated by the output linearisation facility. This function linearises the ratio between flow rate and valve travel in order to obtain a better control of the process. ALARM ON THE OUTPUT VALUES Power output 100% AL2 AL1 Output 5 Measure AL2 AL1 AL2 OP5 3 2 1 FANS The control output percentage is monitored by a configurable process alarm. Using this method it is possible to simplify the control of the process. In the example shown, the instrument is controlling a process by driving an airflow valve. The airflow generator uses 3 fans; the first one is always ON while the second and third are turned ON when the power output reaches the programmed value [33 % (AL 1) and 66% (AL 2)]. This solution reduces power consumption and improves process control. LOGIC INPUTS 3 logic inputs are supplied as standard. These may be configured as: - auto/ manual selection - output limiter activation - manual reset of alarm (acknowledgement) - reverse/ direct control action - run/ hold program selection (level or transition programmable) - program selection, program abort Up to 8 additional logic inputs are available (MKP option). Input type: Active contact: contact closure (voltage free) close or open configurable ADDITIONAL OUTPUTS Up to 10 additional digital outputs are available (MKP). These may be configured as program events. Type: Relay type SPDT Contact rating: 0.5A @ 250V AC (resistive)

PRODUCT SPECIFICATIONS Case: polycarbonate Self extinguishing degree: according to UL 746 C. Front protection: designed and tested for IP 65 and NEMA 4X for indoor locations (when panel gasket is installed). test perfomed in accordance with IEC 529, CEI 70-1 and NEMA 250-1991 STD. Rear terminal board: 32 screw terminals for PKP 54 screw terminals for MKP. Dimensions (according to DIN 43700): Weight: Power supply (switching type): Power consumption: Insulation: Common mode rejection ratio: Normal mode rejection ratio: EMC/Safety: Sampling time: Accuracy: Operating temperature: Storage temperature: Humidity: 48 x 96mm for PKP 96 x 96mm for MKP. Depth 128mm. 500g for PKP. 700g for MKP. from 100 to 240V AC 50/60Hz (from 10% to -15% of the nominal value) or 24V DC/AC (10% of the nominal value). 16VA max. for PKP 20VA max. for MKP. a double or reinforced insulation is guaranteed between the power supply and all the instrument inputs and outputs. > 120dB @ 50/60Hz. > 60dB @ 50/60Hz. This instrument is marked CE. It conforms to council directives 89/336/EEC (reference harmonized standard EN 50081-2 and EN 50082-2), 73/23/EEC and 93/68/EEC (reference harmonized standard EN 61010-1). 125 msec for linear inputs 250 msec for TC or RTD. ± 0.2% f.s.v., @ 25 C and nominal power supply. from 0 to 50 C. from -20 to 70 C. from 20% to 85% RH not condensing. MEASURING INPUTS All inputs are factory calibrated and selectable by front keyboard. It is possible to apply a first order digital filter on the displayed value. The time constant of the filter may be programmed within 0 and 8 seconds. RTD input Type: Pt 100 3 wires connection. Calibration: according to DIN 43760. Line resistance: max. 20Ω/wire with no measurable error. Sensor braek: Standard range table RTD type C F Pt 100-200/850-330/1560 Pt 100-199.9/850.0-199.9/999.9 detection of the sensor open circuit and of one or more wires open circuit. The instrument shows the short circuit indication when the sensor resistance is lower than 12Ω.

Thermocouples Line resistance compensation error: max. ± 0.1% of input span with input impedance <100Ω. Sensor break: detection of the open input circuit (wire or sensor) with underrange or overrange selectable indication. automatic compensation for an ambient temperature Cold junction: between 0 and 50 C. Cold junction compensation error: 0.1 C/ C. Input impedance: > 1MΩ. Calibration: according to IEC 584-1. Linear inputs (ma and V) Auxiliary input (optional) Function: Input linearization: programmable square root extraction. Readout: keyboard programmable from -1999 to 9999. Decimal figure: programmable in any position. Type: Scaling: Sampling time: Accuracy: Temperature drift: this input can be used as trim function, or as remote set point input. not isolated. programmable from -1999 to 9999, the decimal figure is automatically positioned as for main input. 500ms. ± 0.2% f.s.v. ± 1digit @ 25 C and nominal power supply voltage. 300 ppm/ C. Standard range table TC type C F B 0/1820 32/3300 C 0/2300 0/4170 D 0/2300 0/4170 E -100/800-150/1470 G 0/2300 0/4170 L -100/900-150/1650 J -100/1000-150/1830 K -100/1370-150/2500 N -100/1400-150/2550 Ni/niMo 0/1100 0/2000 R -50/1760-60/3200 S -50/1760-60/3200 T -200/400-330/750 U -200/600-330/1100 Standard range table Input Impedance 0-20 ma 5 Ω 4-20 ma 5 Ω 0-60 mv >1MΩ 12-60 mv >1MΩ 0-5 V >200 kω 1-5 V >200 kω 0-10 V >400 kω 2-10 V >400 kω Standard range table Input Impedance 0-20 ma 5 Ω 4-20 ma 5 Ω 0-5 V >200 kω 1-5 V >200 kω 0-10 V >400 kω 2-10 V >400 kω OUTPUTS These products may be supplied with up to 4 digital outputs (relay, SSR, TRIAC or servomotor drive) and up to 2 linear outputs (ma). Digital outputs (Out 1 and 2) Function: Type: singularly programmed as: - control output - alarm output - event output. relay, SSR or TRIAC. Out 1 and 2 - Relay Relay type: Contact rating: SPDT 3A @ 250V AC on resistive load Out 1 and 2 - SSR Type: Out 1 and 2 - TRIAC Switching mode: Triac rating: not isolated voltage outputs. - Logic level 1: 14V @ 20mA max. 24V @ 1 ma. - Logic level 0: < 0.5V isolated zero crossing type. from 50mA to 1A from 24V rms to 250V rms.

Out 3 and 4 Function: Type: Contact rating: MKP.PKP singularly programmed as: - control output - alarm output - event output. - Servomotor drive (OUT 3 open, OUT 4 close). relay SPST. 3A @ 250V AC on resistive load. The OUT 3 and 4 commons are connected together with the same rear terminal. Servomotor output Type: two relays interlocked (OUT 3 and 4). Servomotor output type: - Close loop - Open loop with valve position indication only. - Open loop without valve position indication. Feedback potentiometer input: from 100 W to 10 KW. Servomotor travel time: from 12 seconds to 3 minutes. Servomotor dead band: from 1% to 50% of the feedback span or of the valve travel time. Analog outputs (Out 5 and 6) Function: programmable as - Control output - Analog retransmission of the measured value - Analog retransmission of the operative set point. Output type: Isolated output programmable as: 0-20mA 4-20mA. Scaling: programmable from -1999 to 9999. Maximum load: 600Ω. Accuracy: 0.1% when it is used as control output. 0.05% when it is used as analog retransmission. Filter: it is possible to apply a first order digital filter on the retransmitted value. The time constant of the filter may be programmed within 0 and 8 seconds. CONTROL ACTION Types: Digital output types: Digital output control action: Analog output types: Servomotor output: Proportional band: - one control output (digital or analog output) - one control output split on two outputs (split range). - two control outputs. The outputs can be freely selected among analog, digital or servo. relay, SSR or TRIAC. proportional time linear (20mA). two relays interlocked. programmable from 0.5% to 999.0% of the input span. Setting a PB equal to 0 the control action becomes ON/OFF.

Hysteresis (for ON/OFF control action): Integral time: Derivative time: Integral preload: Main output cycle time: Secondary output cycle time: Relative secondary output gain: Overlap/dead band: Output limiters: AUTO/MANUAL mode: programmable from 0.1% to 10.0% of the input span. programmable from 1 second to 20 minutes or excluded. programmable from 1 second to 10 minutes or excluded. programmable - for one control output, from 0 to 100% of the outpu range. - for two control outputs, from -100% to 100% of the heating/cooling output range. from 1 second to 200 seconds. from 1 second to 200 seconds. programmable from 0.20 to 2.00 referred to proportional band. programmable from -20% (dead band) to 50% (overlap) of the proportional band. for main and/or secondary control outputs it is possible to set: - output high limits - output low limits - output max. rate of rise. selectable by front pushbutton or logic input. ALARMS Process alarm Band alarm Deviation alarm Alarm action: Alarm functions Alarm reset: Alarm masking: Operative mode: Threshold: Hysteresis: Operative mode: Threshold: Hysteresis: Operative mode: Threshold: Hysteresis: direct or reverse function programmable. each alarm can be configured as process alarm, band alarm, deviation alarm or process alarm on the output value. automatic or manual reset programmable for each alarm. each alarm can be configured as masked alarm or standard alarm. This function allows to delete not desired alarm indications at instrument start up and after a set point changement. minimum or maximum programmable. programmable in engineering units within input range. programmable in engineering units from 1 to 200 digits. inside or outside programmable. two thresholds are programmable: low - from 0 to -1000 digits. high - from 0 to 1000 digits. programmable in engineering units from 1 to 200 digits. high or low programmable. programmable from -1000 to 1000 digits. programmable in engineering units from 1 to 200 digits. Alarm on the main output values It is possible to obtain an alarm condition when the main control output is lower or higher than a programmed value.

Operative mode: Threshold: Hysteresis: minimum or maximum programmable. programmable from 0.1 to 100.0% of the output. programmable in engineering units from 0.1 to 20.0% of the output. Alarm on the secondary output values Operative mode: Threshold: Hysteresis: Output failure detection (OFD) minimum or maximum programmable. programmable from 0.1 to 100.0% of the output. programmable in engineering units from 0.1 to 20.0% of the output. the instruments equipped with this feature are capable of measuring, by means of a CT, the running current of one control output. Minimum active period to perform the measurement: Input range: 50mA AC. Scaling: programmable from 10A to 100 A. Resolution: - for full scale up to 20A : 0,1A - for full scale from 21A to 100A: 1A Active period: - for relay output: NO or NC programmable. - for SSR output: logic level 1 or 0. 120 msec. this function is applicable only to a control output programmed as proportional time output (relay or SSR). SERIAL INTERFACE (optional) Type: RS 485 isolated. Protocol type: MODBUS, JBUS. Baud rate: programmable from 600 to 19200 BAUD. Byte format: 8 bit. Parity: even, odd or none programmable. Stop bit: one. Address: from 1 to 255. Output voltage levels: according to EIA standard. AUXILIARY POWER SUPPLY (optional) An un-isolated auxiliary power supply option enables direct connection of a 2, 3 or 4-wire transmitters and eliminates the need for an additional, separate power supply unit. Type: 24V DC ± 20% not isolated. Max. current: 25mA.

DIMENSIONS AND PANEL CUT - OUT MKP 15 max 1.5 125 ERO ELECTRONIC 92 0 0.8 125 92 0 0.8 96 108.4 RESET FUNC RESET FUNC MKP 96 128 16 DIMENSIONS AND PANEL CUT - OUT PKP 15 max 1.5 60 ERO ELECTRONIC 125 108.4 96 92 0 0.8 45 0 0.6 RESET FUNC RESET FUNC PKP 48 128 16

REAR TERMINAL BLOCK MKP REAR TERMINAL BLOCK PKP IN COMMON IN1 IN2 IN3 IN4 56 45 57 46 58 47 59 48 60 49 IN COMMON IN5 IN6 IN7 IN8 OUT1 TRIAC OUT2 TRIAC LINE LOAD OUT1 SSR LINE LOAD OUT2 SSR OUT1 RELAY OUT2 RELAY NC 23 12 C 24 13 NO 25 14 NO 26 15 IN-CT C 27 16 OUT10 61 50 OUT15 NO 28 17 FEEDBACK OUT5 1 3 4 5 6 T/C RTD AUX IN OUT1 TRIAC LINE LOAD OUT1 SSR OUT2 TRIAC LINE LOAD OUT2 SSR OUT1 RELAY OUT2 RELAY NC 23 12 C 24 13 NO 25 14 NO 26 15 IN-CT C 27 16 NO 28 17 FEEDBACK OUT5 1 T/C 3 4 5 6 RTD AUX IN OUT11 OUT12 OUT13 OUT14 OUT COMMON 62 51 OUT16 63 52 OUT17 64 53 OUT18 65 54 OUT19 66 55 OUT COMMON MOTOR AC OUT3 RELAY OUT4 RELAY PWR LINE NO 29 18 C 30 19 OUT6 C/C NO 31 20 B/B N 32 21 A/A L 33 22 RS485 7 8 9 10 11 DIG3 DIG2 DIG1 24V 25mA AUX PWS MOTOR AC OUT3 RELAY OUT4 RELAY PWR LINE NO 29 18 C 30 19 OUT6 C/C NO 31 20 B/B N 32 21 A/A L 33 22 RS485 7 8 9 10 DIG3 11 DIG2 DIG1 24V 25mA AUX PWS HOW TO ORDER Current transformer (for instrument with OFD option only) DIMENSIONS MODEL CTR current transformer PRIMARY CURRENT 1 10A 2 25A 3 50A 4 100A CTR

HOW TO ORDER MODEL INPUT OUT 1 and OUT 2 OUT 3 and OUT 4 OUT 5 and OUT 6 OPTIONS POWER SUPPLY MKP 1/4 DIN 1 main Aux-in. logic inputs 11 two relay outputs 1 two Relay outputs 0 not provided 0 not provided 3 100/240V AC PKP 1/8 DIN 6 Main Aux-in Logic inputs OFD (or Feedback) 44 two TRIAC outputs 61 one SSR one relay output 2 two relay outputs interlockable by jumper 5 two ma outputs 7 One ma output (Out 5) 1 aux.pws 2 RS485 Aux. PWS 5 24V AC/DC 66 two SSR outputs 4 Clock calendar RS485 Aux. PWS 5 Clock calendar Aux.PWS 6* RS485 Aux.PWS 4 logic inputs 5 Digital outputs 7* RS485Aux.PWS 8 logic inputs 10 Digital outputs 8* Clock calendar RS485 Aux.PWS 4 Logic inputs 5 Digital outputs 9* Clock calendar RS485 Aux.PWS 8 Logic inputs 10 Digital outputs * only for MKP ERO ELECTRONIC VIA XXIV MAGGIO 22070 GUANZATE (CO) ITALY TEL. 39 031 975 111 FAX. 39 031 977 512 SALES@EROELECTRONIC.COM - WWW.EROELECTRONIC.COM ERO ELECTRONIC a division of EUROTHERM S.r.l. A170.CAT.MKP.00E