REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

Similar documents
BMG/TMG -27, 48, 52, 74, 80 LAE CONTROLLER Installation & Operations Manual

NO-FROST CUSTOMER SUPPORT INFORMATION INFORMATION ON THE NO-FROST TECHNOLOGY WHITE GOODS

INSTRUCTION MANUAL REFRIGERATOR BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

Troubleshooting Your Refrigerator

3.5 CU.FT. REFRIGERATOR INSTRUCTION MANUAL HMBR350BE HMBR350SE

DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL

4.5 CU.FT. REFRIGERATOR INSTRUCTION MANUAL

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

Wine Cooler with Thermo-Electric Cooling & Heating Technology

3.6 CU.FT. REFRIGERATOR INSTRUCTION MANUAL

WHYNTER 21 Bottle Dual Temperature Zone Freestanding Wine Cooler

4.4 CU.FT. REFRIGERATOR INSTRUCTION MANUAL HMBR445BE HMBR445SE

CARING FOR YOUR WATER HEATER

Vertical Display and Storage B SKOPE Gen2: Three Door Chiller

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

Table Z. Troubleshooting Chart for Air Conditioners. Cause

MODEL INSTALLATION INSTRUCTIONS

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

SAFETY PRECAUTIONS Read all of the instructions before using this appliance. When using this appliance, always exercise basic safely precautions,

REFRIGERATOR INSTRUCTION MANUAL. Model No.: MCBR170W/B/S

Convection Ovens. BX Classic. Models BX4 / FG 189C, BX / FG 158C, BX10 / FG 180C. Operator's Manual

PREVENTATIVE MAINTENANCE

BUILT-IN WINE & BEVERAGE COOLER WITH DUAL TEMPERATURE ZONES INSTRUCTION MANUAL. Model No.: MCWBC77DZC

Hot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100]

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

STAINLESS STEEL WINE / BEVERAGE COOLER INSTRUCTION MANUAL HVBC31ST

Operating Instructions Control Settings...5 Inside of Refrigerator...5 Care and Cleaning...6

SANDWICH/SALAD PREP & MEGA TOP UNDERCOUNTER REFRIGERATOR UNDERCOUNTER FREEZER

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N

General Purpose Laboratory Freezer with Alarms

WINDOW ROOM AIR CONDITIONER

Dehumidifier Users manual. For Models: DH45S DH65S

A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps

INSTRUCTION MANUAL. Pizza Prep Tables Megatop Sandwich/Salad Units Undercounter Refrigerators and Freezers Worktop Refrigerators and Freezers

REF Series Undercounter Refrigerator

5800 Temperature Sensor Cable Assembly

Portable Air Conditioner

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model #

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Compressor Service & Maintenance Manual

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

WHYNTER 20 Bottle Thermoelectric Wine Cooler MODEL # : WC-201TD

Use & Care Guide AIR CONDITIONERS ACM052 ACM062 ACM072

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Whynter 62 QT DUAL ZONE PORTABLE FRIDGE / FREEZER

2-DOOR REFRIGERATOR / FREEZER

OWNER S GUIDE OPERATION & INSTALLATION

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

Utility Distribution Systems


CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

Instruction manual for Wine Cabinet

Heat Pump Water Heater IOM Manual

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Low Profile Unit Cooler

Central Air Conditioner

Installation Instructions

AIR CONDITIONER & HEAT PUMP DIGITAL CONTROL FOR DUCTED SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS

Undercounter Refrigerators and Freezers

ICE AIR. Console Water Source Heat Pump (WSHP) OPERATING & MAINTENANCE MANUAL. Wo r l d C l a s s C o m f o r t.

INSTRUCTION MANUAL FOR RECREATIONAL REFRIGERATOR/FREEZER MODEL

T15 AIR CONDITIONER INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

Miami Heat Pump HP Series Installation Guide

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

SWIMMING POOL HEAT PUMP

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

ADDING AN ELECTRIC AUXILIARY FAN TO RADIATOR STACK ON 03 ALPINE COACH

PC1131 Electric Air Compressor

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

Operating Manual. Los Angeles Abrasion Machine HM-70A & HM-70AF

USER S MANUAL HSC-24A

HEAT RECOVERY VENTILATORS MODELS 90H-V ECM HRV, 90H-V+, 60H-V+ AND ENERGY RECOVERY VENTILATOR MODEL 90H-V ECM ERV

12V Portable Diaphragm Compressor Operating and Maintenance Instructions

Packaged Terminal Air Conditioner Wall Sleeve Installation

Use and Care Manual. Model CPA12KH AIR CONDITIONER

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Heat Pump USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW RESIDENTIAL HEAT PUMP

How to Maintain an Air Conditioner

AFE424 SERVICE PARTS

SIBIR MANUAL V110 KE. English page 5 RKE - 1D

Safety, Operation and Maintenance Manual with Parts List

Air Conditioner B B

MFU200 Integrated Under Counter Larder Fridge

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

Oil and Coolant Circulating Heating System. Model - OCSM

WALL MOUNTED SPLIT TYPE AIR CONDITIONER

First irst Co. Products

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:

PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

ESPD8-301R MODEL ESP-D FAN COIL UNIT TROUBLESHOOTING GUIDE

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

Transcription:

REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions INSPECTION When the equipment is received, all items should be carefully checked against the bill of lading to insure all crates and cartons have been received. All units should be inspected for concealed damage by uncrating the units immediately. If any damage is found, it should be reported to the carrier at once, and a claim should be filed with the carrier. This equipment has been inspected and tested in the manufacturing facility and has been crated in accordance with transportation rules and guidelines. Manufacturer is not responsible for freight loss or damage. GENERAL INSTALLATION After the unit crate and crate base have been removed, locate the casters or legs found inside the cabinet. (Not applicable for Roll-In models). Attach the casters or legs to the unit base by screwing them into the same threaded fittings that were used to secure the crate base to the cabinet. Insure that the legs or casters are screwed completely into the base. The cabinet should also be levelled when it is placed in its permanent location. For shipping purposes, the condensing unit compressor is secured on the extra low temperature models. Remove the spring clips and loosen the mounting bolts prior to operation. See the label attached to the condensing unit. If the doors are out of alignment on the cabinet, the doors can be adjusted. This can be accomplished by opening the door(s) and loosening the screws that hold both the top and bottom hinges to the cabinet. After adjusting the door so that it is aligned correctly, tighten the screws to securely hold the hinges in place. VAPORIZER INSTALLATION Some of the Refrigerators and all of the Extra Low Temperature Freezers require the installation of the condensate vaporizer which is shipped inside the unit compartment. The vaporizer should be mounted to the cabinet bottom. Reference View 1. In lieu of the vaporizer, these units can be plumbed to a floor drain following local plumbing codes. The Freezers, Pass-Thru and Roll-In Refrigerators use a hot gas vaporizer. Customer installation is not required. 1 12/15 Rev. C 127717

Note: Disconnect power prior to installation. 1. Connect the power cord to the vaporizer and place it in the vaporizer bracket. 2. Attach the vaporizer bracket to the back of the unit using the four screws as shown, making sure the plastic drain tube is in the vaporizer pan. LOCATION The refrigeration system located at the top of the cabinet requires free air access for proper operation. Allow a minimum four (4) inch clearance on the top, rear, and sides of the cabinet. The cabinet should also be levelled when it is placed in its permanent location. There are no provisions for easily levelling the Roll-In models except by the use of shims. Only minimal shimming is allowable. A cabinet that will sit directly on the floor without casters should be levelled when placed in its permanent location. If casters are not used, it is required by NSF that the cabinet be sealed to the floor with an approved sealant such as Dow Corning #732 silicone. ELECTRICAL Check the proposed outlet to be used to insure that the voltage, phase and current carrying capacity of the circuit from the electrical panel correspond to the requirements of the cabinet. NEVER use an extension cord to wire any unit. On permanently connected units, those not furnished with a plug-in service cord, all inter-wiring between the electrical panel and the unit must be done in accordance with the National Electric Code and all state and local codes. Refer to the serial tag for all pertinent electrical information. Observe all Warning Labels. Disconnect power supply to eliminate injury from electrical shock or moving parts when servicing equipment. GENERAL OPERATION The refrigerators and freezers employ a unit cooler evaporator located outside the cabinet as the heat removing source. Through the refrigeration process, heat is captured in the evaporator, transferred to the condensing unit on top of the cabinet, and expelled to the surrounding outside air. It is extremely important to allow a four (4) inch clearance on the top, rear, and sides of the unit for the refrigeration process to function properly. These refrigerators and freezers utilize a programmable controller to control the temperature and defrost settings. The controller, which is located on the facade of the unit, is factory set. Please see the default settings sheet and separate instructions that are included on the operation of this controller. 2 12/15 Rev. C 127717

REFRIGERATORS During the operation of a refrigerator unit, frost will periodically form on the coil surface. Each time the compressor cycles "off", the evaporator fans will continue to run, which will keep the internal temperature uniform and at the same time remove any frost build up on the coil. The water produced will collect in the unit cooler drain pan and travel down the drain tube to the condensate vaporizer. FREEZERS After shutting the door on freezer models, a short amount of time must be allowed before the door can be reopened. This is due to the tight seal maintained between the door and the cabinet. Waiting a few moments for the pressure to equalize permits the door to be opened easily. A positive defrost is required to remove frost from the coil in freezer models. This is accomplished by energizing heaters during the defrost cycle that are positioned on the coil surface. The programmable controller is factory set to allow four defrosts per day. As the preset defrost time is reached, the controller automatically terminates the refrigeration process by turning off the condensing unit and unit cooler fan motors, and energizes the defrost heaters. As the coil temperature increases, the frost begins to melt producing water which runs down the coil to the unit cooler drain pan and exits through the drain tube to the vaporizer. After all the frost has been removed and the coil temperature reaches approximately 50 F [10ºC], the defrost is terminated through the action of the defrost termination control located on the unit cooler, and the refrigeration process resumes. In order to insure that any excess water remaining on the coil is not sprayed into the cabinet interior, and all heat generated by the defrost is removed, the unit cooler fans will not operate until the coil temperature reaches approximately 25 F [-4ºC]. Note: Running a cold wall model freezer in an unconditioned environment may result in frost build-up inside the cabinet. PERIODIC CLEANING GENERAL MAINTENANCE Beginning with the initial installation, the interior surfaces of the cabinet should be periodically wiped down with a solution of warm water and baking soda. This solution will remove any odors from spillage that has occurred. The exterior of the cabinet should also be cleaned frequently with a commercial grade of glass cleaner. Monthly cleaning of the condenser will aid the heat transfer characteristics of the refrigeration system and increase its efficiency. To accomplish this, remove the cover panel from the cabinet and use a wire brush to loosen any dirt particles that are attached to the fins. Use a vacuum cleaner to remove the loosened particles. Failure to keep the condenser coil clean and clear of obstructions could result in temperature loss and damage to the compressor. The shelving and pilasters should be periodically cleaned. The shelving should be removed from the cabinet interior and washed with warm water and mild detergent using a soft bristle brush or may be washed in a dishwasher large enough to accommodate the shelving size. Pilasters may be removed from the cabinet interior by using a Philips screwdriver. Unscrew the Philips head screws securing the pilasters to the cabinet interior walls. Retain the screws in a 3 12/15 Rev. C 127717

secure place for re-installation. Wash the pilasters with warm water and a mild detergent in a suitable place suitable for this effort such as a deep sink. A soft bristle brush is recommended to reach the interior area of the pilasters. Re-install the pilasters and shelving when the cleaning procedure is complete. Drain connections to the evaporator pan and the evaporator pan should be periodically cleaned to prevent any build up of debris, fungi, etc. See the cleaning instructions on the following page (B13351). See the instructions below for cleaning the evaporator drain pan. All moving parts have been permanently lubricated and will generally require no maintenance. Door hinges should also be periodically cleaned. The door(s) must be removed to gain adequate access to the hinges. See the illustrations on next page for solid door and glass door removal. 4 12/15 Rev. C 127717

SOLID DOOR REMOVAL FOR HINGE CLEANING 1. Open door to stay position, locate top hinge of door. 2. Remove screws for hinge. After screws are removed, grasp top hinge firmly and allow the hinge bracket to close to the door.!!caution!! Hinge under high tension Pinch point hazard 3. Once tension has been removed lift door up to remove. Wipe area clean with mild soap, do not use abrasives. 4. Reverse steps to re-install. 5 12/15 Rev. C 127717

GLASS DOOR REMOVAL FOR HINGE CLEANING 1. Open door, locate door heater power cord (if applicable) and remove screw. 2. Remove black spacer clip. 3. Pry open hinge stay to clear stop pin. 4. Locate hinge tension tool (Taped on door upon delivery). Insert tool in spring notch on bottom of door, push toward cabinet and then release front trigger. Skip this step for doors with full length handles. 5. Once tension has been removed lift door up to remove. 6. Remove screws for hinge. 7. Wipe clean with mild soap. Note: reverse process to install door. 6 12/15 Rev. C 127717

MAINTENANCE SERVICE AND ANALYSIS GUIDE REFRIGERATION SYSTEMS - ALL MODELS MALFUNCTION POSSIBLE CAUSE SOLUTION Compressor will not start - 1. Service cord unplugged 1. Plug in service cord no hum 2. Fuse blown or removed 2. Replace fuse 3. Overload tripped 3. Determine reasons and correct 4. Control stuck open 4. Repair or replace 5. Wiring incorrect 5. Check wiring against the diagram Compressor will not start - 1. Improperly wired 1. Check wiring against the diagram hums but trips on overload 2. Low voltage to unit 2. Determine reason and correct protector 3. Starting capacitor defective 3. Determine reason and replace 4. Relay failing to close 4. Determine reason, correct or replace Compressor starts and runs, 1. Low voltage to unit 1. Determine reason and correct but short cycles on overload 2. Overload defective 2. Check current, replace overload protector protector 3. Excessive head pressure 3. Check ventilation or restriction in refrigeration system 4. Compressor hot-return gas hot 4. Check refrigerant charge, fix leak if necessary Compressor operates long 1. Short of refrigerant 1. Fix leak, add charge or continuously 2. Control contact stuck 2. Repair or replace 3. Evaporator coil iced 3. Determine cause, defrost manually 4. Restriction in refrigeration system 4. Determine location and remove restriction 5. Dirty condenser 5. Clean condenser Compressor runs fine, but 1. Overload protector 1. Check wiring diagram short cycles 2. Cold control 2. Differential too close - widen 3. Overcharge 3. Reduce charge 4. Air in system 4. Purge and recharge 5. Undercharge 5. Fix leak, add refrigerant Starting capacitor open, 1. Relay contacts stuck 1. Clean contacts or replace relay shorted or blown 2. Low voltage to unit 2. Determine reason and correct 3. Improper relay 3. Replace Relay defective or burned out 1. Incorrect relay 1. Check and replace 2. Voltage too high or too low 2. Determine reason and correct Refrigerated space too warm 1. Control setting too high 1. Reset control 2. Refrigerant overcharge 2. Purge refrigerant 3. Dirty condenser 3. Clean condenser 4. Evaporator coil iced 4. Determine reason and defrost 5. Not operating 5. Determine reason, replace if necessary Standard temperature system 1. Control setting is too low 1. Reset the control freezes the product 2. Control points stuck 2. Replace the control Objectionable noise 1. Fan blade hitting fan shroud 1. Reform or cut away small section of shroud 2. Tubing rattle 2. Locate and reform 3. Vibrating fan blade 3. Replace fan blade 4. Condenser fan motor rattles 4. Check motor bracket mounting, tighten 5. General vibration 5. Compressor suspension bolts not loosened on applicable models - loosen them 6. Worn fan motor bearings 6. Replace fan motor Pan Area 1. No cooling 1. Make sure switch is in the "on" position 2. Too cold 2. Adjust temperature control - see instructions under pan area 3. Too warm 3. Adjust temperature control - see instructions under pan area 7 12/15 Rev. C 127717

REMOTE REFRIGERATION DATA Model BTU @ 100 F Solid Dr & 86 F Glass Dr Refrig't Voltage Amps Exp valve ELEC VAPORIZER NR241SSS/0R 850 @ +28 F EVAP R404a 115/60/1 0.53 YES NO NR241SSG/0R 1260 @ +28 F EVAP R404a 115/60/1 0.53 YES NO NR242SSS/0R 850 @ +28 F EVAP R404a 115/60/1 0.53 YES NO NR242SSG/0R 1260 @ +28 F EVAP R404a 115/60/1 0.53 YES NO NR522SSS/0R 1580 @ +28 F EVAP R404a 115/60/1 0.9 YES NO NR522SSG/0R 2450 @ +28 F EVAP R404a 115/60/1 0.9 YES NO NR524SSS/0R 1580 @ +28 F EVAP R404a 115/60/1 0.9 YES NO NR524SSG/0R 2450 @ +28 F EVAP R404a 115/60/1 0.9 YES NO NR803SSS/0R 2250 @ +28 F EVAP R404a 115/60/1 1.1 YES NO NR803SSG/0R 3580 @ +28 F EVAP R404a 115/60/1 1.1 YES NO NR806SSS/0R 2255 @ +28 F EVAP R404a 115/60/1 1.1 YES NO NR806SSG/0R 3580 @ +28 F EVAP R404a 115/60/1 1.1 YES NO WR331SSS/0R 1370@ +28 F EVAP R404a 115/60/1 0.76 YES NO WR722SSS/0R 2635@ +28 F EVAP R404a 115/60/1 1.36 YES NO PWR332SSS/0R 1500@ +28 F EVAP R404a 115/60/1 1.0 YES NO PWR724SSS/0R 2875@ +28 F EVAP R404a 208-230/60/1 1.82 YES NO NF241SSS/0R 1820 @ -10 F EVAP R404a 115/60/1 4.7 YES NO NF242SSS/0R 1820 @ -10 F EVAP R404a 115/60/1 4.7 YES NO NF522SSS/0R 2855 @ -10 F EVAP R404a 115/60/1 6.9 YES NO NF524SSS/0R 2855 @ -10 F EVAP R404a 115/60/1 6.9 YES NO NF803SSS/0R 3505 @ -10 F EVAP R404a 115/60/1 7.4 YES NO NF806SSS/0R 3505 @ -10 F EVAP R404a 115/60/1 7.4 YES NO NOTES: 1) Cord and plug are not supplied with these units 2) Compressor size to be determined by a qualified refrigeration technician based on the delivered BTU rating at the unit and actual jobsite requirements. 3) BTU rating shown is the required BTU's at the evap coil. 4) Standard five year compressor warranty does not apply to these units. 5) Condensate removal is the responsibility of the customer. A short drain line exiting the unit cooler section on the top of the cabinet is provided for the purpose of extending. 6) Legs are standard on remote systems as they are generally hard piped to the condensing unit. 7) The solenoid valve mounted on the cabinet is factory wired to the control. No connections are required between the cabinet and the remote compressor. 8 12/15 Rev. C 127717